HomeMy WebLinkAboutMFP23001708.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23001708
IVR Number: 23001708
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:04/03/2023Application Date:2146000010Parcel Number: 710 THOMAS AVE SW
Permit Type:05/24/2023Issue Date:Franchise
Permit Work Class:05/23/2024Expiration Date:Minor Utility
Job Number: 101131329Franchise Type:Electric
Description: Puget Sound Energy Electric INSTALLING CONDUIT AND UG 3PHASE CABLES BY BORING AND TRENCHING
APPROX 680'. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031ApplicantX
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
C/O PROGOGIS - RE TAX 1800 WAZEE ST
DENVER , CO 80202
Owner
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
PLEASE SEE ATTACHED
POTELCO, INC
6905 S 228TH ST KENT, WA 98032
101131329
710 THOMAS AVE SW
CARLOS CHAVEZ 253-691-2840
MFP23001708
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 5/24/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
CORRIE RYDBERG
710 Thomas Ave SW
Renton
WA 98057
USA
710 Thomas Ave SW
Renton
WA 98057
USA
J01
THOMAS AVE SWTHOMAS AVE SW2020
2020
JW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1STOP
FLAGGER
STOP
FLAGGER
W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROAD
WORK
AHEAD W20-18_X_10-PLATE
8_X_10-PLATE
8_X_10-PLATE
8_X_10-PLATE
PV01
BUSINESS(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
PLACE SIGNS ALONG
WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
TEMPORARY TRAFFIC CONTROL PLAN
N
11111111STOP
FLAGGER
STOP
FLAGGER
FLAGGER FOR
DRIVEWAY CONTROL
STOP
FLAGGER
FLAGGERS TO BE PLACED AT EACH
DRIVEWAY WITHIN THE WORK AREA
WORK AREA
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Ina Ustemchuk
425-398-6063
ina.ustemchuk@pse.com
1 OF 3710 Thomas Ave SW, Renton, WA
1
11707483
02/27/2023
Puget Sound EnergyTraffic Control Supervisor:
Ina Ustemchuk
Card No. 012928
Card Exp.07/31/2025
ina.ustemchuk@pse.com
(425)398-6063
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001708
2020
THOMAS AVE SWJ01
THOMAS AVE SW2020
JW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1STOP
FLAGGER
W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEAD W20-1PV01
8_X_10-PLATE
8_X_10-PLATE
8_X_10-PLATE
8_X_10-PLATE
STOP
FLAGGER
BUSINESS(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
PLACE SIGNS ALONG
WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Ina Ustemchuk
425-398-6063
ina.ustemchuk@pse.com
2 OF 3710 Thomas Ave SW, Renton, WA
1
11707483
02/27/2023
Puget Sound EnergyTraffic Control Supervisor:
Ina Ustemchuk
Card No. 012928
Card Exp.07/31/2025
ina.ustemchuk@pse.com
(425)398-6063
TEMPORARY TRAFFIC CONTROL PLAN
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY11111111STOP
FLAGGER
STOP
FLAGGER
FLAGGER FOR
DRIVEWAY CONTROL
STOP
FLAGGER
FLAGGERS TO BE PLACED AT EACH
DRIVEWAY WITHIN THE WORK AREA
WORK AREA
MFP23001708
10 10 10
1010
10
10
10
SW 10TH S
T THOMAS AVE SW2020
2020
STOP
FLAGGER
STOP
FLAGGER
W20-7AROADWORKAHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'BUSINESS(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
PLACE SIGNS ALONG
WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
PV01
J02
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Ina Ustemchuk
425-398-6063
ina.ustemchuk@pse.com
3 OF 3710 Thomas Ave SW, Renton, WA
1
11707483
02/27/2023
Puget Sound EnergyTraffic Control Supervisor:
Ina Ustemchuk
Card No. 012928
Card Exp.07/31/2025
ina.ustemchuk@pse.com
(425)398-6063
TEMPORARY TRAFFIC CONTROL PLAN
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY11111111STOP
FLAGGER
STOP
FLAGGER
FLAGGER FOR
DRIVEWAY CONTROL
STOP
FLAGGER
FLAGGERS TO BE PLACED AT EACH
DRIVEWAY WITHIN THE WORK AREA
WORK AREA
MFP23001708
BP-1
BP-2BORE ~ 235'BORE ~ 235'BP-3
OPEN TRENCH ~ 5'
OPEN TRENCH ~ 5'
AØ10130
BØ10131
CØ10132 619 lbs 619 lbs236 lbs 228 lbs
EIX433 - AØ
EIX434 - BØ
EIX435 - CØ
1-4" - L______'101131329R1UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
C. CHAVEZ 253-691-2840 03/08/23
L. NEELY 253-569-2523 03/08/23
N/A N/A N/A
C. CHAVEZ 253-691-2840 03/08/23
N/A CITY OF RENTON
EAR - 16 CREW2 O#612959 710 THOMA
REPLACE 3-PHASE UG CABLES
710 THOMAS AVE SW, RENTON, WA 98057
O#612959 N/A
N/A 101131329
AS NOTED 1 OF 2
KING N/A N/A QCSOKE
T23N, R04E, 24-NE N/A N/A
2304E093 2305E076 2304E093 EAR-16
4/25/23 C. CHAVEZ ADDED CIVIL SITE PLAN
N/A N/A N/A
N/A N/A N/A
Potelco, Inc.DESIGNED BY
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL
Notify Customers and Service Area
48 HRS Prior To Planned Outages
ORDER#NOTIF#PROJECT PHASE
MAINTENENCE
O & M
SUPERIOR
FAILED SILICONE
REMOVAL
EXPENSE
11707483 101131329
N/A
108122743
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
SITE PLAN
SCALE: 1:50
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
Carlos Chavez
For contacts below dial 1-888-CALL PSE (225-5773)
EXISTING UNDERGROUND MAP
(BEFORE): # .
SCALE: 1:100
2304E093
JOB SITE
VICINITY MAP
JOB SITE
CIVIL CREW NOTE: ALL 4" - 90° BENDS MIN 60" RADIUS SCH-80 PVC
ALL 4" - 45° BENDS SCH-80 PVC
- ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL
CABLE IS INSTALLED
PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE)
LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE
(gal.)REMARKS
FROM TO SIZE
(in)QTY
DESIGN
LENGTH
(ft)
ACTUAL
LENGTH
(ft)
TYPE BENDS PULL
(lbs)
PULL
REV
(lbs)
SIZE
DESIGN
LENGTH
(ft)
ACTUAL
LENGTH
(ft)
CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only
Check applicable box
DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS
BUILT
J01 PV01 4 1 500 619 619 1/0 AL JKT 520
EIX433 EIX434 EIX435
3.1
PV01 J02 --EXISTING 236 228 1/0 AL JKT 160 0
TOTAL 4"500'TOTAL 3Ø 680'TOTAL LUBE 3.1
VAULT & EQUIPMENT TABLE
SITE GRID
NUMBER VAULT SIZE & COVER TYPE & SIZE
EQUIPMENT IN VAULT
PRIMARY
BUSHINGS TRANSFORMER
ID NUMBERS
(COMPANY ID)
REMARKS
LB DC
PV01 317502
165529
EXISTING
PULL VAULT
EXISTING
PULL VAULT -- REPLACE SPLICE & CONDUCTORS
WIRE CREW TO INSTALL GRID NUMBERS
J01 317549
165530
EXISTING COMBO
VAULT
J-BOX BELOW GRADE
W/ 3-4 POS. J-BUS
25kVA TUT XFMR
120/240v EXISTING
3 - REPLACE ELBOWS & CONDUCTORS
WIRE CREW TO INSTALL GRID NUMBERS
J02 317492
165519
EXISTING
JUNCTION BOX
J-BOX BELOW GRADE
W/ 3-4 POS. J-BUS
EXISTING
3 - REPLACE ELBOWS & CONDUCTORS
WIRE CREW TO INSTALL GRID NUMBERS
TOTALS :6 -
ABANDONED / REMOVE / REPLACED CABLE SCHEDULE
CABLE
NO.
SAP
EQUIP
LOCATIONS CABLE
(LF) EST
EXISTING CABLE
MFG. NAME
EXISTING CABLE
MFG. DATE
ABANDONED
CABLE LEFT IN
PLACE
ABANDON
CIRCUITRYFROMTO
10130 UNK J01 J02 669 YES NO
10131 UNK J01 J02 669 YES NO
10132 10619581 J01 J02 669 YES NO
TOTAL CIRCUIT FEET 669'
VOLUME OF DISTURBANCE TABLE
TYPE DESCRIPTION PROPERTY
CLASSIFCATION
SIZE (FT)REM CU YD
(APPX)
GRAVEL FILL
CU YD (APPX)
COMMON SURFACE
TYPES
REMARKS
BP-1 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT
BP-2 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT
BP-3 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT
OPEN TRENCH TRENCH ROW 1 X 10 X 3 1.1 1.1 ASPHALT
TOTAL PVT PROP CU YDS (APPX)0.0 0.0
TOTAL ROW CU YDS (APPX)6.4 6.4
TOTAL CU YDS (APPX)6.4 6.4
POTELCO DESIGN AND
Signature _________________________________________
Print Name _________________________________________
This design complies with PSE
Any/all variations have been
Design/Engineering Standards.
QUALITY ASSURANCE
pre-approved/documented by the
appropriate PSE Representative.
Date _________________
SITE SPECIFIC NOTES
-RETURN SYSTEM BACK TO NORMAL
-CREW TO CALL SYSTEM OPS AND CLOSE O# 612959
EXISTING UNDERGROUND MAP
(AFTER): # .
SCALE: 1:100
2304E093
03/08/23
Carlos Chavez
L. NEELY 253-569-2523 03/08/23
MFP23001708
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
710THOMAS AVE SW (PAVED)813
BP-1
BP-2BORE ~ 235'BORE ~ 235'OPEN TRENCH ~ 5'
WATER MAIN TO
BORE PATH ~ 6'
WATER MAIN TO
BORE PATH ~ 6'
ROW = 60'
EOP = 40'
STORM DRAIN TO
BORE PATH ~ 17'
SEWER TO
BORE PATH ~ 27'
933
THOMAS AVE SW (PAVED)EXISTING CONDUIT
BP-3
OPEN TRENCH ~ 5'
WATER MAIN TO
BORE PATH ~ 6'
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
C. CHAVEZ 253-691-2840 03/08/23
L. NEELY 253-569-2523 03/08/23
N/A N/A N/A
C. CHAVEZ 253-691-2840 03/08/23
N/A CITY OF RENTON
EAR - 16 CREW2 O#612959 710 THOMA
REPLACE 3-PHASE UG CABLES
710 THOMAS AVE SW, RENTON, WA 98057
O#612959 N/A
N/A 101131329
AS NOTED 2 OF 2
KING N/A N/A QCSOKE
T23N, R04E, 24-NE N/A N/A
2304E093 2305E076 2304E093 EAR-16
4/25/23 C. CHAVEZ ADDED CIVIL SITE PLAN
N/A N/A N/A
N/A N/A N/A 101131329R1CIVIL SITE DETAILED PLAN
SCALE: 1:30
Electric Cable in HDPE Conduit
Final Grade
24" Typical
(6" Min)
36" Min
Cover
Backfill shall not damage the conduit.
Backfill hard surface w/
while directional drilling
36" Min
Depth
Final Grade
24" Typical
(6" Min)8' Longcrushed rock 5/8 minus
Backfill soft surface with
clean natural material
PLAN VIEWTYPICAL BORE COVER
Will maintain 36" Min. depth
BORE PIT DETAIL
NOT TO SCALE
BORE PIT
POT HOLE
*NOTE:BORE PITS, TRENCH HATCHING & POTHOLES ARE NOT
SHOWN TO SCALE FOR VISUAL PURPOSES. PLEASE SEE BORE
PIT DETAIL FOR TYP. BORE PIT & TRENCH DIMENSIONS.
4" Min Shading Clean Native
Soil, Sand or 5/8" Minus
2" Min Bedding Clean Native
Soil, Sand or 5/8" Minus
EXISTING WATER
EXISTING POWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING STORM DRAIN
EXISTING SEWER
LEGEND
EXISTING FIBER OPTIC
STREET CENTER LINECL
RIGHT OF WAY
CABLE TO REPLACE
BORE PIT
BORE PIT"BP"-
NEW J-BOX VAULT
PROPERTY LINE
EASEMENT
POT HOLE
POT HOLE"PH"-
Potelco, Inc.DESIGNED BY
CIVIL FOREMAN NOTE:
POTHOLING IS REQUIRED PRIOR TO DRILLING AND THE
BORE PROFILE SHALL BE PREPARED ON SITE AND PROVIDED
TO THE INSPECTOR FOR APPROVAL.
NEW CONDUIT SHALL BE AT 36" MINIMUM DEPTH TO THE
TOP AND MAINTAIN A MINIMUM 1-FOOT VERTICAL
CLEARANCE BETWEEN OUTER SURFACE OF EXISTING
STRUCTURE AND MINIMUM 5-FOOT HORIZONTAL
SEPARATION OF WATER MAIN, STORM DRAIN AND SEWER
STRUCTURE.
CALL (800) 424-5555 UTILITY NOTIFICATION CENTER 24/7 BEFORE
BEGINNING ANY EXCAVATION PREVENTS DAMAGE TO
UNDERGROUND FACILITIES, SERVICE INTERRUPTIONS & BODILY
INJURY.
INSTALL CATCH BASIN INSERT ON ALL CB WITH
CONSTRUCTION ZONE.
ALL SPOILS WILL BE HAULED OFF SITE.
5/8" MINUS CRUSHED ROCK WILL BE USED FOR BACKFILL
MATCHLINE "A"
SEE PAGE 2A A
SEE PAGE 2
MATCHLINE "A"A A
CIVIL SITE DETAILED PLAN (CONTINUED)
SCALE: 1:30
MFP23001708