Loading...
HomeMy WebLinkAboutMFP23001708.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23001708 IVR Number: 23001708 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:04/03/2023Application Date:2146000010Parcel Number: 710 THOMAS AVE SW Permit Type:05/24/2023Issue Date:Franchise Permit Work Class:05/23/2024Expiration Date:Minor Utility Job Number: 101131329Franchise Type:Electric Description: Puget Sound Energy Electric INSTALLING CONDUIT AND UG 3PHASE CABLES BY BORING AND TRENCHING APPROX 680'. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact C/O PROGOGIS - RE TAX 1800 WAZEE ST DENVER , CO 80202 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering PLEASE SEE ATTACHED POTELCO, INC 6905 S 228TH ST KENT, WA 98032 101131329 710 THOMAS AVE SW CARLOS CHAVEZ 253-691-2840 MFP23001708 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 5/24/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG 710 Thomas Ave SW Renton WA 98057 USA 710 Thomas Ave SW Renton WA 98057 USA J01 THOMAS AVE SWTHOMAS AVE SW2020 2020 JW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1STOP FLAGGER STOP FLAGGER W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROAD WORK AHEAD W20-18_X_10-PLATE 8_X_10-PLATE 8_X_10-PLATE 8_X_10-PLATE PV01 BUSINESS(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA R K TEMPORARY TRAFFIC CONTROL PLAN N 11111111STOP FLAGGER STOP FLAGGER FLAGGER FOR DRIVEWAY CONTROL STOP FLAGGER FLAGGERS TO BE PLACED AT EACH DRIVEWAY WITHIN THE WORK AREA WORK AREA Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Ina Ustemchuk 425-398-6063 ina.ustemchuk@pse.com 1 OF 3710 Thomas Ave SW, Renton, WA 1 11707483 02/27/2023 Puget Sound EnergyTraffic Control Supervisor: Ina Ustemchuk Card No. 012928 Card Exp.07/31/2025 ina.ustemchuk@pse.com (425)398-6063 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 MFP23001708 2020 THOMAS AVE SWJ01 THOMAS AVE SW2020 JW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1STOP FLAGGER W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEAD W20-1PV01 8_X_10-PLATE 8_X_10-PLATE 8_X_10-PLATE 8_X_10-PLATE STOP FLAGGER BUSINESS(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Ina Ustemchuk 425-398-6063 ina.ustemchuk@pse.com 2 OF 3710 Thomas Ave SW, Renton, WA 1 11707483 02/27/2023 Puget Sound EnergyTraffic Control Supervisor: Ina Ustemchuk Card No. 012928 Card Exp.07/31/2025 ina.ustemchuk@pse.com (425)398-6063 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY11111111STOP FLAGGER STOP FLAGGER FLAGGER FOR DRIVEWAY CONTROL STOP FLAGGER FLAGGERS TO BE PLACED AT EACH DRIVEWAY WITHIN THE WORK AREA WORK AREA MFP23001708 10 10 10 1010 10 10 10 SW 10TH S T THOMAS AVE SW2020 2020 STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'BUSINESS(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK PV01 J02 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Ina Ustemchuk 425-398-6063 ina.ustemchuk@pse.com 3 OF 3710 Thomas Ave SW, Renton, WA 1 11707483 02/27/2023 Puget Sound EnergyTraffic Control Supervisor: Ina Ustemchuk Card No. 012928 Card Exp.07/31/2025 ina.ustemchuk@pse.com (425)398-6063 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. TRENCH 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY11111111STOP FLAGGER STOP FLAGGER FLAGGER FOR DRIVEWAY CONTROL STOP FLAGGER FLAGGERS TO BE PLACED AT EACH DRIVEWAY WITHIN THE WORK AREA WORK AREA MFP23001708 BP-1 BP-2BORE ~ 235'BORE ~ 235'BP-3 OPEN TRENCH ~ 5' OPEN TRENCH ~ 5' AØ10130 BØ10131 CØ10132 619 lbs 619 lbs236 lbs 228 lbs EIX433 - AØ EIX434 - BØ EIX435 - CØ 1-4" - L______'101131329R1UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. CHAVEZ 253-691-2840 03/08/23 L. NEELY 253-569-2523 03/08/23 N/A N/A N/A C. CHAVEZ 253-691-2840 03/08/23 N/A CITY OF RENTON EAR - 16 CREW2 O#612959 710 THOMA REPLACE 3-PHASE UG CABLES 710 THOMAS AVE SW, RENTON, WA 98057 O#612959 N/A N/A 101131329 AS NOTED 1 OF 2 KING N/A N/A QCSOKE T23N, R04E, 24-NE N/A N/A 2304E093 2305E076 2304E093 EAR-16 4/25/23 C. CHAVEZ ADDED CIVIL SITE PLAN N/A N/A N/A N/A N/A N/A Potelco, Inc.DESIGNED BY No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENENCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 11707483 101131329 N/A 108122743 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE SITE PLAN SCALE: 1:50 FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Carlos Chavez For contacts below dial 1-888-CALL PSE (225-5773) EXISTING UNDERGROUND MAP (BEFORE): # . SCALE: 1:100 2304E093 JOB SITE VICINITY MAP JOB SITE CIVIL CREW NOTE: ALL 4" - 90° BENDS MIN 60" RADIUS SCH-80 PVC ALL 4" - 45° BENDS SCH-80 PVC - ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL CABLE IS INSTALLED PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)REMARKS FROM TO SIZE (in)QTY DESIGN LENGTH (ft) ACTUAL LENGTH (ft) TYPE BENDS PULL (lbs) PULL REV (lbs) SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only Check applicable box DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS BUILT J01 PV01 4 1 500 619 619 1/0 AL JKT 520 EIX433 EIX434 EIX435 3.1 PV01 J02 --EXISTING 236 228 1/0 AL JKT 160 0 TOTAL 4"500'TOTAL 3Ø 680'TOTAL LUBE 3.1 VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC PV01 317502 165529 EXISTING PULL VAULT EXISTING PULL VAULT -- REPLACE SPLICE & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS J01 317549 165530 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS. J-BUS 25kVA TUT XFMR 120/240v EXISTING 3 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS J02 317492 165519 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING 3 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS TOTALS :6 - ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRYFROMTO 10130 UNK J01 J02 669 YES NO 10131 UNK J01 J02 669 YES NO 10132 10619581 J01 J02 669 YES NO TOTAL CIRCUIT FEET 669' VOLUME OF DISTURBANCE TABLE TYPE DESCRIPTION PROPERTY CLASSIFCATION SIZE (FT)REM CU YD (APPX) GRAVEL FILL CU YD (APPX) COMMON SURFACE TYPES REMARKS BP-1 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-2 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-3 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT OPEN TRENCH TRENCH ROW 1 X 10 X 3 1.1 1.1 ASPHALT TOTAL PVT PROP CU YDS (APPX)0.0 0.0 TOTAL ROW CU YDS (APPX)6.4 6.4 TOTAL CU YDS (APPX)6.4 6.4 POTELCO DESIGN AND Signature _________________________________________ Print Name _________________________________________ This design complies with PSE Any/all variations have been Design/Engineering Standards. QUALITY ASSURANCE pre-approved/documented by the appropriate PSE Representative. Date _________________ SITE SPECIFIC NOTES -RETURN SYSTEM BACK TO NORMAL -CREW TO CALL SYSTEM OPS AND CLOSE O# 612959 EXISTING UNDERGROUND MAP (AFTER): # . SCALE: 1:100 2304E093 03/08/23 Carlos Chavez L. NEELY 253-569-2523 03/08/23 MFP23001708 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS 710THOMAS AVE SW (PAVED)813 BP-1 BP-2BORE ~ 235'BORE ~ 235'OPEN TRENCH ~ 5' WATER MAIN TO BORE PATH ~ 6' WATER MAIN TO BORE PATH ~ 6' ROW = 60' EOP = 40' STORM DRAIN TO BORE PATH ~ 17' SEWER TO BORE PATH ~ 27' 933 THOMAS AVE SW (PAVED)EXISTING CONDUIT BP-3 OPEN TRENCH ~ 5' WATER MAIN TO BORE PATH ~ 6' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. CHAVEZ 253-691-2840 03/08/23 L. NEELY 253-569-2523 03/08/23 N/A N/A N/A C. CHAVEZ 253-691-2840 03/08/23 N/A CITY OF RENTON EAR - 16 CREW2 O#612959 710 THOMA REPLACE 3-PHASE UG CABLES 710 THOMAS AVE SW, RENTON, WA 98057 O#612959 N/A N/A 101131329 AS NOTED 2 OF 2 KING N/A N/A QCSOKE T23N, R04E, 24-NE N/A N/A 2304E093 2305E076 2304E093 EAR-16 4/25/23 C. CHAVEZ ADDED CIVIL SITE PLAN N/A N/A N/A N/A N/A N/A 101131329R1CIVIL SITE DETAILED PLAN SCALE: 1:30 Electric Cable in HDPE Conduit Final Grade 24" Typical (6" Min) 36" Min Cover Backfill shall not damage the conduit. Backfill hard surface w/ while directional drilling 36" Min Depth Final Grade 24" Typical (6" Min)8' Longcrushed rock 5/8 minus Backfill soft surface with clean natural material PLAN VIEWTYPICAL BORE COVER Will maintain 36" Min. depth BORE PIT DETAIL NOT TO SCALE BORE PIT POT HOLE *NOTE:BORE PITS, TRENCH HATCHING & POTHOLES ARE NOT SHOWN TO SCALE FOR VISUAL PURPOSES. PLEASE SEE BORE PIT DETAIL FOR TYP. BORE PIT & TRENCH DIMENSIONS. 4" Min Shading Clean Native Soil, Sand or 5/8" Minus 2" Min Bedding Clean Native Soil, Sand or 5/8" Minus EXISTING WATER EXISTING POWER EXISTING TELEPHONE EXISTING GAS EXISTING STORM DRAIN EXISTING SEWER LEGEND EXISTING FIBER OPTIC STREET CENTER LINECL RIGHT OF WAY CABLE TO REPLACE BORE PIT BORE PIT"BP"- NEW J-BOX VAULT PROPERTY LINE EASEMENT POT HOLE POT HOLE"PH"- Potelco, Inc.DESIGNED BY CIVIL FOREMAN NOTE: POTHOLING IS REQUIRED PRIOR TO DRILLING AND THE BORE PROFILE SHALL BE PREPARED ON SITE AND PROVIDED TO THE INSPECTOR FOR APPROVAL. NEW CONDUIT SHALL BE AT 36" MINIMUM DEPTH TO THE TOP AND MAINTAIN A MINIMUM 1-FOOT VERTICAL CLEARANCE BETWEEN OUTER SURFACE OF EXISTING STRUCTURE AND MINIMUM 5-FOOT HORIZONTAL SEPARATION OF WATER MAIN, STORM DRAIN AND SEWER STRUCTURE. CALL (800) 424-5555 UTILITY NOTIFICATION CENTER 24/7 BEFORE BEGINNING ANY EXCAVATION PREVENTS DAMAGE TO UNDERGROUND FACILITIES, SERVICE INTERRUPTIONS & BODILY INJURY. INSTALL CATCH BASIN INSERT ON ALL CB WITH CONSTRUCTION ZONE. ALL SPOILS WILL BE HAULED OFF SITE. 5/8" MINUS CRUSHED ROCK WILL BE USED FOR BACKFILL MATCHLINE "A" SEE PAGE 2A A SEE PAGE 2 MATCHLINE "A"A A CIVIL SITE DETAILED PLAN (CONTINUED) SCALE: 1:30 MFP23001708