HomeMy WebLinkAbout16-0718 Kinkade Crossing Utility III Plan CommentsSTOP SIGN IS SHOWN ON PRIVATE
PROPERTY. SHOW SIGN IN PUBLIC RIGHT
OF WAY. THERE IS AN EXISTING SPEED
LIMIT SIGN IN THE SAME LOCATION.
ADDRESS HOW YOU PLAN TO INSTALL
THE STOP SIGN WITH THE EXISTING
SPEED LIMIT SIGN.
ROTATE SIGN
TO FACE WEST
ADD NPDES PERMIT
NUMBER TO PLAN
Lot Area
65%
Impervious
Allowed for
R-8 Zoned
Lots
Proposed
55%
Impervious
Impervious
Area Credit
(SF)(SF)(SF)(SF)
1 5,434 3,532 2,989 543
2 5,137 3,339 2,825 514
3 6,095 3,962 3,352 609
4 6,075 3,949 3,341 608
5 5,116 3,325 2,814 512
6 5,127 3,333 2,820 513
7 5,127 3,333 2,820 513
8 5,128 3,333 2,820 513
9 5,128 3,333 2,820 513
10 5,868 3,814 3,228 587
11 5,743 3,733 3,159 574
12 5,001 3,251 2,751 500
13 5,544 3,604 3,049 554
14 5,220 3,393 2,871 522
15 5,136 3,338 2,825 514
16 5,116 3,326 2,814 512
17 5,048 3,281 2,776 505
TOTAL 91,044 59,179 50,074 9,104
Required BMP Impervious Area Reduction (SF)
Lot Area X 10% =9,104
Provided BMP Impervious Area Reduction (SF)9,104
Lot
Number
REMOVE THESE
LINES (TYP)
MODIFY DRIVEWAY
WINGS TO BE
TRIANGULAR, PLANTER
SHALL BE LOCATED
BEHIND TRIANGULAR
PIECE. (TYP)
THIS NEEDS TO BE A
YARD DRAIN PER COR
STD. PLAN 225.10
YARD DRAIN (TYP)
YARD DRAIN (TYP)
YARD DRAIN (TYP)
YARD DRAIN (TYP)
YARD DRAIN (TYP)
REMOVE DETAIL FROM PLAN. A
NEW DETAIL IS IN DEVELOPMENT
AND WILL BE PROVIDED PRIOR TO
CONSTRUCTION.
PROVIDE DETAIL
SHOWING PIPE INLET
AND OUTLET
CONFIGURATION
SIMILAR TO DETAILS
SHOWN ON SHEET DT-04
THIS INLET IS
LOWER THAN THE
POND BOTTOM
4' X 6.5'
0.54%
THE ELEVATIONS
DO NOT MATCH THE
KCRTS MODEL.
DOES NOT
MATCH PROFILE
ON SHEET PN-02
SPECIFY THE CARTRIDGE SIZE AND STACK
CONFIGURATION THAT YOU ARE USING FOR
EACH PERK FILTER VAULT. ENSURE THAT
REQUIRED DROP IS PROVIDED IN PROFILE.
ADD COR STD. PLAN 204.10
- RECTANGULAR SOLID
METAL COVER
USE COR STD.
PLAN 104.1