HomeMy WebLinkAboutMFP23001384.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP23001384
IVR Number: 23001384
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:03/15/2023Application Date:7227801405Parcel Number: 975 NE 12TH ST
Permit Type:06/15/2023Issue Date:Franchise
Permit Work Class:06/14/2024Expiration Date:Major Utility
Job Number: 101141447Franchise Type:Electric
Description: Puget Sound Energy Electric OH wreckout of poles & wires P01 P02 P03 P04, Replace pole P01 w/ new pole.
customer to trench in ROW during construction, roads will be closed. Joint trench to be under new roads, sidewalk
and plantar strips. 575 jbox vaults J03 and J02 to be placed in ROW. At IP2, dig pit to intercept and reroute 2 6" feeder
runs south 90' to private property. Pothole all existing utilities. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031ApplicantX
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
SOLERA MANAGER LLC 10900 NE 8TH ST STE 1200
BELLEVUE , WA 98004
Owner
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
PLEASE SEE ATTACHED
POTELCO, INC
6905 S 228TH ST KENT, WA 98032
101141447
2828 SUNSET LN NE
LUCAS KNAUSS 253-313-8029
MFP23001384
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 6/15/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
CORRIE RYDBERG
111110
10
N
E
1
0
T
H
S
T
12
12
NE
1
0
TH
S
T SUNSET LN NEVault
14 14
J01HARRINGTON AVE NEW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1STOP
FLAGGER
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC
000
0000
000 NO PARKINGNO-PA
RK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKUSE MAXIMUM AVAILABLE
SPACE FOR SIGNS
STOP
FLAGGER
STOP
FLAGGER
W20-7A
W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1 J02E02
W20-7AW20-4ONE LANEROADAHEAD10
0
'
10
0
'ROADWORKAHEADW20-1100
'
RO
A
D
W
O
R
K
AH
E
A
D
W20-1100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
1 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
VAULTVault
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001384
111110
10
NE
1
0
TH
S
T
12
12
N
E
1
0
T
H
S
T SUNSET LN NEVault
14 14
J01HARRINGTON AVE NEPLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE
LLC
000
000000
0 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
J02E02
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-410
0
'
10
0
'
10
0
'W20-7ARO
A
D
WO
R
K
AH
E
A
D
W20-1BEPR
E
P
A
R
E
D
TO
ST
O
P W3-4100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
2 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
VAULTVault
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001384
111110
10
NE
1
0
TH
S
T
12
12
N
E
1
0
T
H
S
T SUNSET LN NEVault
14 14
J01HARRINGTON AVE NEPLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999
INFRASOURCE LLC
000
00000
00 NO PARKINGNO-P
A
RK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
J02E02
STOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-410
0
'
10
0
'
10
0
'W20-7ARO
A
D
WO
R
K
AH
E
A
D
W20-1BEPR
E
P
A
R
E
D
TO
ST
O
P W3-4100'100'100'W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4
100'100'100'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'W20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
3 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
VAULTVault
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001384
2828 NE Sunset Blvd Renton WA 9805612
12
SUNSET LN NE10 10 10 1010 10 10 10NE 12TH ST JEFFERSON AVE NEHARRINGTON PL NE18
18
SUNSET
LN
NE1717NE 12TH ST
J02Vault
J03
Vault
Vault
J05
P01
P02W20-7AW20-4ONE LANEROADAHEAD100'100'ROADWORKAHEADW20-1
100'S/WCLOSEDR9-9CROSS HERESIDEWALK CLOSEDAHEADRESIDENT(S)/BUSINESS(ES) WILL
BE INFORMED OF POSSIBLE
TEMPORARY DRIVEWAY CLOSURE
S/
WCL
O
S
E
DR9-9CR
O
S
S
H
E
R
E
SID
E
W
A
L
K
C
L
O
S
E
D
AH
E
A
D
W20-7ARO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AH
E
A
D100'100'100'STOP
FLAGGER
STOP
FLAGGER ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1100'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE
LLC
0
00
0000000NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKP03
AREA UNDER
CONSTRUCTION
AREA UNDER
CONSTRUCTION
17 17
IP2 IP3
SW1 SW2J06J07
Vault J04
P04
E01
TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
4 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001384
2828 NE Sunset Blvd Renton WA 9805612
12
SUNSET LN NE10 10 10 1010 10 10 10NE 12TH ST JEFFERSON AVE NEHARRINGTON PL NE18
18
SUNSE
T
LN
NE1717NE 12TH ST
J02Vault
J03
Vault
Vault
J05
P01
P02
RESIDENT(S)/BUSINESS(ES) WILL
BE INFORMED OF POSSIBLE
TEMPORARY DRIVEWAY CLOSURE
W20-7ARO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AHE
A
D100'100'100'PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE
LLC
000
000000
0 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
P03
AREA UNDER
CONSTRUCTION
AREA UNDER
CONSTRUCTION
17 17
IP2 IP3
SW1 SW2J06J07
Vault J04
P04
E01
STOP
FLAGGER
STOP
FLAGGERW20-7AW20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
5 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TRENCH
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP23001384
12
12
SUNSET LN NE10 10 10 1010 10 10 10NE 12TH ST JEFFERSON AVE NEHARRINGTON PL NE18
18
SU
NS
E
T
LN
N
E17
17100'
NE 12TH ST
Vault
J05
P01
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1
100'S/WCLOSEDR9-9CROSS HERESIDEWALK CLOSEDAHEADRESIDENT(S)/BUSINESS(ES) WILL
BE INFORMED OF POSSIBLE
TEMPORARY DRIVEWAY CLOSURE
W20-7ARO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AH
E
A
D100'100'10
0
'PLACE SIGNSBOTH SIDES OFWORK AREAFROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARKFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
AREA UNDER
CONSTRUCTION
J03
Vault
P02
FLAGGERS SHALL STOP TRAFFIC
IN ALL DIRECTIONS (SHORT DURATION:
APPROX 10 MINUTES) FOR LINE DROP.
17 17
IP2 IP3
SW1 SW2J06J07
2828 NE Sunset Blvd Renton WA 98056Vault J04
P04
E01
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
0'60'30'
PRINT ON
11X17" SHEETS ONLYN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
02/10/2022
101141447
1
2828 SUNSET LN NE, RENTON, WA 98056.
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
6 OF 7
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
MFP23001384
10 10 10 10NE 12TH STJEFFERSON AVE NE
HARRINGTON PL NE1818SUNSET LN NE1717
NE 12TH STVaultJ05P01ROADWORKAHEADW20-1100'P021717IP2IP3SW1SW2J06J07KIRKLAND AVE NEN
E
S
U
N
S
E
T
B
L
V
DALL-WAYSTOP101010101818181810101010KIRKLAND AVE NEROADWORKAHEADW20-1100'
RIGHT LANE
CLOSED
AHEAD W20-5RW4-2RROAD
WORK
AHEAD W20-1100'100'100'ROADWORKAHEADW20-1 100'100'ROADWORKAHEADW20-1 RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1100'100'100'M6-2M6-2X'X'PLACE W20-1 SIGNS ON ALLADJACENT STREETS WITHIN FEET OF WORK AREAROADWORKAHEADW20-1 ROADWORKAHEADW20-1AREA UNDERCONSTRUCTIONJ04P04TEMPORARY TRAFFIC CONTROL PLAN28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPVAULTVaultWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.0'60'30'PRINT ON11X17" SHEETS ONLYNProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REV02/10/2022 1011414471 2828 SUNSET LN NE, RENTON, WA 98056.Jason Bisenius425-424-7316jason.bisenius@pse.com7 OF 7Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425MFP23001384
N
Vicinity Map
N/A
101141447 1. GENERAL
Pre-construction Notify appropriate City or
County 48 to 72 hours or as required by
permitting agency before starting work on
any right-of-way involving a permit.
Follow all requirements as outlined by the
permitting agency.
Locate and mark all underground utilities
prior to start of construction. If there is a
conflict with the intended trench route as
shown on the site plan and existing
utilities or obstructions, trench route may
need to be moved to opposite side of
street. Cooperation with Quality Inspector,
Puget Sound Energy Contractor, City or
County authorities during Pre-construction
meeting will determine the final trench
route.
2. Existing Utilities
Hand excavate (pothole) all marked utility
crossings to verify exact location and
depth at point of crossing. Protect
underground utilities during excavation.
Use hand excavation methods if necessary
to avoid damage. Fabricate and install
adequate temporary structures to support
and protect underground utilities while
exposed during construction.
Maintain 12" minimum clearance at
crossings between existing utilities and
new duct installations. Transition trench
or tunnel profile gradually as required at
crossings. Maintain 24" minimum
separation between new trench or tunnel
and parallel existing utilities or as required
by the PERMIT AGENCY .
In the event of damage to an underground
utility, notify Puget Sound Energy at once.
Contractor agrees to make work force and
resources available at once to Puget
Sound Energy or municipal authorities to
repair damage at no cost.
3. Work Drawings
Maintain on site, in good condition, a
complete file of all work drawings. These
drawings shall be available at all times to
a Puget Sound Energy representative.
Corrections and changes made during the
job shall be recorded continuously on
these drawings. All underground
electrical facilities shall have a minimum
of 36 inches of cover. Any change must
be approved by the PSE engineer or
project manager. Furnish Puget Sound
Energy a complete set of as built prints
(foreman's copies) at the end of the job.
4. Safety
Provide signs, barricades, and traffic
control in conformance with local
jurisdictions and regulations. Provide
flagging and or other vehicle traffic control
as needed in conformance with local
regulations. (see SPM # 100.4000) Provide
adequate signage and protection to traffic
during non-working hours. Maintain
traffic flow as required by permitting
agency. Provide signs and barricades to
warn pedestrians, motorcycles and
bicycles.
Install warning barricades at least every 50
feet along the trench route from the time
the trench is opened until the trenching is
complete.
5. Existing Systems
Maintain existing electrical system in service
until new system is complete, tested, and
ready for service. Disable existing system
only to make cutovers and connections as
directed by Puget Sound Energy's
representative.
ELECTRICAL
1. Conduit
Conduit for installation in unpaved areas shall be 2", 3", 4", or 6" PVC SCHL 80 or 2", 3", 4", or 6"
SCHL 80 for direct burial. Maintain 36" minimum cover above top conduit at all times or as
required by the permitting agency.
Where conduit is routed from road edge to vault location, maintain 36" minimum cover above top
conduit at all times or as required by the permitting agency. Bends shall be made with as long a
radius as possible (48" minimum). Avoid making sharp bends or kinks in conduit during
installation. Obtain exact location of conduit entrance into vault from Puget Sound Energy before
penetrating vault. Penetrate the vault using existing knockout or use core drilled holes. Stub the
4" or 6" PVC 2"-3" into vault interior and grout between the conduit and vault wall. Leave a 10'
minimum of extra pull rope in each end of installed conduit where 4" or 6" PVC is installed and
cap conduit to prevent the entry of dirt and moisture.
Arrange work so conduit plays directly off reel into trench. Place the conduit in the trench as
straight as possible. Avoid vertical and horizontal "snaking" of the conduit. Multiple conduit runs
may be stacked vertically. Where conduit must be pulled through a trench to allow a crossing
under an existing utility, cap conduit end before pulling to avoid contamination. If a kink occurs,
cut the conduit ahead of kink and splice to new conduit to continue run.
2. Underground Primary Cable
Primary cable shall be 1/O Alum Sol Jacketed Cable rated for 15 KV service with a polyethylene
jacket. Primary cable shall be 61 strand 750 MCM aluminum conductor rated for 15 KV service
with a copper tape neutral conductor and polyethylene jacket. A 4/0 copper neutral shall be run
with each 3 phase circuit of 750 MCM.
Install cable into existing or new conduit systems using approved installation equipment.
Approved equipment includes either cable pullers and/or cable pushers. Pulling socks shall be
non-conductive or similar material. Steel pulling socks are prohibited. Bare steel cable shall not
be used to pull cable. Cable pulling equipment (winches, hoist, driven reels, etc.) shall be
equipped with instrumentation to continually monitor and record peak tension encountered during
a pull. Before installing cable, obtain rated pulling tension for cable from Puget Sound Energy.
Do not exceed rating at any time during installation. Notify Puget Sound Energy immediately if
pulling tension equals or exceeds rating (828/1657lbs for 1/0 or 5000lbs for 750 .) Do not exceed
minimum bend radius of cable or impose kinks or sharp bends on cable during pulling operations.
Install cable directly off reel without dragging it on the ground. Apply Puget Sound Energy
approved lubricant to cable continually during pulling to reduce pulling tension and to permit future
removal.
Install adequate amounts of 3/4 " plywood on existing sidewalk areas to support pulling equipment
and prevent un-necessary damage to sidewalks.
Train and coil cables in vaults as required to form a smooth transition from conduit to termination.
if terminations are to be performed by others, coil 15' of cable in vault and cap end.
3. Terminations and Splices
Install approved terminations on cables in accordance with Puget Sound Energy SPM 2247.5115-
5119. Unless otherwise directed, approved terminations will be load break elbows in vaults and
cold shrink pin terminals on pole risers per Puget Sound Energy SPM 2247.9317.
Splice cable with approved splice kits in vaults, hand holes or similar enclosures. Do not splice
cables in runs between vaults. See Puget Sound Energy SPM 2233.2075-2076.
4. Concrete Vaults
Excavate, install base material, and compact base material in accordance with Puget
Sound Energy SPM 6775.0040.
Install and seal precast sections in accordance with Puget Sound Energy SPM 6775.0040. Use
precast neck and shaft sections to bring manhole entrance to proper elevation. Install manholes
plumb. Set the top of each manhole to finished elevation or no higher than 6" above existing road
elevation. Install hillholders as required on sketch or by construction notes.
5. Grounding
Install ground rod per Puget Sound Energy SPM 6275.6100 at each vault in which primary cable
is terminated. Locate rod in trench excavation wherever possible to obtain maximum driven depth
in undisturbed soil. Connect each ground individually to ground loop inside vault with bare no. 2
copper jumper or to Concentric neutral at each splice vault location. Minimum grounding
requirement is 4 grounds per mile.
6. Existing Underground Primary Cable (if applicable)
Abandon existing primary cable in place. Cut off old cable ends inside vault flush with wall.
Before cutting, pigtail concentric neutral strands and connect to ground loop inside vault. Return
scrap cable and existing cable tags to Puget Sound Energy. Remove or fill existing vaults as
required by permitting agency.
7. Traffic Control
All traffic control to comply with current specifications in M.U.T.C.D.
Provide temporary wiring and connections
to maintain existing systems in service
during construction; if a scheduled outage
is not possible. When work must be
performed on energized equipment or
circuits, use qualified personnel for such
operations.
EARTHWORK
See Puget Sound Energy SPM 6800.4050
1. Back hoe, Hand Dug Excavations
Paved Surfaces
Cut the edges of the trench prior to
digging. Use the narrowest bucket
practical or plow off the edge of paved
surface far enough to minimize asphalt
disturbance. Repair any blow out areas
(where edge has been broken) by
sawing. The depth of the trench shall be
enough to allow 36" of cover . Backfill
material shall be Controlled Density Fill
(CDF) cover or select fill (5/8" minus) to
meet permit requirements.
Unpaved Surfaces
Conduit/cable trenches are to be
excavated just off the existing road edge
or in the shoulder of the road behind the
existing ditch line. Contractor shall use
a back hoe with the narrowest width
bucket practical or plow. Trench shall
be deep enough to allow a minimum of
36" of cover over the top most cable. All
ditch crossings shall have a minimum of
36" cover from the lowest point within
the existing ditch line.
Culverts; when installing facilities under
a culvert, excavation must be filled with
packed crush rock. If any culvert is
damaged it will be repaired or replaced
in accordance with permitting agency
and contractors responsibility.
Spoils shall be removed quickly to
minimize blocking of traffic. All spoils
and wastes become the property of the
contractor immediately upon removal.
Remove spoils and wastes promptly to
an approved disposal site. Remove
spoils containing asphalt or concrete to
a disposal site specifically approved for
such materials. Provide Puget Sound
Energy with a disposal receipt for all
spoils.
2. Backfill
Unpaved Road Surfaces
Backfill for unpaved road crossings
shall consist of 1-1/2" to 2-1/2" material
compacted to 95% density. Backfill for
unpaved road sections shall consist of
native material compacted to 95%
density.
At the end of each workday, backfill or
plate all trench, remove all spoils and
clean roadway surface of large
hazardous debris.
3. Surface Restoration
Unpaved Surfaces
Restore ground surface to original
contour. Restore to original condition or
better.
4. Landscaping
Arrange and perform work to minimize
impact to existing landscaping. Restore
landscaping that has been disturbed
during the course of work, including
seeding of banks and fills. Vaults set in
bank areas may require re-sloping the
surrounding land to avoid sloughing.
Leave area in its original state or better
at the end of construction. Hand dig if
required to prevent damage to tree roots.
SOLERA PROJECT
SCHEDULE 73
OH TO UG DISTRIBUTION CONVERSION
NOTE:
DEVELOPER TO PROVIDE ALL CIVIL WORK: TO AND INCLUDING
EXCAVATION, BACKFILL, SHORING, TRENCH MAINTENANCE,
SANDING FOR DUCT, SELECT 5/8" CRUSH FOR UNDER VAULTS,
COMPACTION, ALL HARD SURFACE RESTORATION AND RELATED
LANDSCAPING RESTORATION. DEVELOPER TO PROVIDE
TEMPORARY EXCAVATION PLATING (IF REQUIRED).
ALL CROSSING TO BE DONE PARALLEL OR PERPENDICULAR TO
ROAD. STRAIGHT CROSSING ONLY.
POWER GENERAL NOTES - COMMERCIAL PROJECT
8.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
Inclement weather conditions may cause delays in construction times and dates.
1.
2.
3.
4.
5.
6.
7.
9.
11.
10.
CIRCUIT FEET ADDED: 1,920'
CIRCUIT FEET REMOVED: 340'
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
PRE-11
06/2020
224.00 231.00 260.00
0.00 0.00 0.00
224.00 231.00 260.00
JOB SITE
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
UNDERGROUND CIRCUIT MAP
SCALE: 1" = 75'
JOB SITE
JOB SITE
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 1/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Owner / Developer Contact Info
officeATTN:
SOLERA MANAGER, LLC
10900 NE 8TH ST. SUITE 1200
BELLEVUE, WA 98004
DALTON ARNDT 253-606-0715
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
101141447511313228
101144243
108132925
593241018
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:
Tin.Nguyen@pse.com
(253) 244-4303
Tin Nguyen
UG Misc
Pole Replacement
Removal
OH Misc
594147421
LUCAS KNAUSS 253-313-8029 1/25/22
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 1/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
Tin.Nguyen@pse.com
Fabian Gomez 3/17/2022
LUCAS KNAUSS 253-313-8029 1/25/22
MFP23001384
This permit is for Major construction work in the ROW and will be billed at an additional
$158/HR for inspections. After hours and weekend work will be billed at $175/HR
℄℄
℄
℄℄℄2825
975
RO
W
50'
PRE
11
#2ACSRCBAN
S
U
N
S
E
T
L
N
N
E
SUNSET LN NEHARRINGTON PL NEHARRINGTON PL NEEX. ROW40'PROPOSEDROW 60'PROPOSEDROW 60'
E
X
.
R
O
W
50
'
318620-166726
X787HIG13318622-166725
318607-166743
SLAH5037
#2ACSR
±8
0
'
318610-166752
1000 kVA 277/480V (ABC)
318619-166715
100 kVA 120/240V (A)
318610-166735
J
318616-166751
150 kVA 208V (ABC)
J
REMOVAL SITE PLAN
SCALE: 1" = 50'
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
SITE SPECIFIC NOTES
AT P01: 318610-166735
- EXISTING 1964 45' CL3 DISTRIBUTION POLE TO BE REMOVED
- REMOVE ALL PSE EQUIPMENT AND FRAMING
- SEE PAGE 4 FOR NEW POLE INSTALL
AT P02: 318610-166735
- EXISTING 1964 45' CL3 DISTRIBUTION POLE TO BE REMOVED
- REMOVE ALL PSE EQUIPMENT AND FRAMING
AT P03: 318616-166751
- EXISTING 1964 45' CL3 DISTRIBUTION POLE TO BE REMOVED
- REMOVE ALL PSE EQUIPMENT AND FRAMING
AT P04: 318607-166743
- EXISTING 1964 45' CL3 DISTRIBUTION POLE TO BE REMOVED
- REMOVE ALL PSE EQUIPMENT AND FRAMING
SPAN SPECIFIC NOTES
- REFER TO ONE LINE DIAGRAMS AND TABLES FOR INSTALL
101141447WIRE REMOVAL TABLE
Work
Location Wire Size & Type Quantity
Length
(per
conductor)
Remarks
From To
P01 P02 PRI #2 ACSR 3 100'
P02 P03 GUY SPAN 1 180'
P02 P04 LEGACY - #4
ACSR 3 80'
P04 P03 LEGACY - #4
ACSR 3 160'
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
318616-166751
50 kVA
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
Wk
Loc
Pole Data Pole
TEL TV FIBER TRAN RMVD ID NUMBER
Grid #Length Class Year TOPPED RMVD
P01 318620-166726 45 CL-3 1980
P02 318610-166735 45'UNK 1964
P04 318607-166743 45'UNK 1960
P03 318616-166751 45'UNK 1961
00 1"2"
00 50'100'
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
318616-166751
50 kVA
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
318616-166751
50 kVA
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 2/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
LUCAS KNAUSS 253-313-8029 1/25/22
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 2/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Fabian Gomez 3/17/2022
LUCAS KNAUSS 253-313-8029 1/25/22
MFP23001384
℄℄2908
1171
975
BREAKLINE
318650-166771
318649-166771
318649-166772
25 kVA (C)
318648-166782
318648-166756
318642-166758
318642-166756
U86913
318641-166756
U86912
318641-166758
318640-166757
318641-166757
LVE
LVE
J J J
J
J℄℄℄℄℄
℄
℄℄℄1170 1175
2825
1162
975
2806
2813
1140
1100
2806HARRINGTON AVE NEHARRINGTON AVE NER
O
W
50'
318611-166710
75 kVA 120/240V (A)
PRE
11
#2ACSRCBAN
S
U
N
S
E
T
L
N
N
E
SUNSET LN NEHARRINGTON PL NEHARRINGTON PL NE℄
N
E
1
0
T
H
S
T
318557-166687
318605-166743EX. ROW40'PROPOSEDROW 60'PROPOSEDROW 60'
E
X
.
R
O
W
50
'
P
R
O
P
O
S
E
D
R
O
W
6
0
'
318620-166726
X787
318608-166737HIG13318602-166683
100 kVA (B)
318621-166701
100 kVA (B)
318575-166698
300 kVA 208V (ABC)
318622-166725
SUNSET LN NE#2ACSR
318610-166752
1000 kVA 277/480V (ABC)
318619-166715
100 kVA 120/240V (A)
J
J
J
JBREAKLINE
318556-166708
318614-166738
25 kVA 120/240V (A)
318641-166758
JJ
J
J
JSITE PLAN
SCALE: 1" = 50'
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
SITE SPECIFIC NOTES
-AT P01 318620-166726
- REMOVE EXISTING 1980 45' 2 DISTRUBITION POLE
- INSTALL NEW 55 H1 DISTRIBUTION POLE W/ GROUNDS 6010.1000 (PD55H1)
- DEEP SET POLE +2' W/ POLE WRAP (9997789) 6450.6100
- INSTALL 3Ø DE #2ACSR PER STD 6033.1040 (DE2315)
AT J01: 318557-166687
- EXISTING HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS TO REMAIN
- REMOVE (3) 200A DUST CAPS
- INSTALL (3) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL CABLE TAG # EJA834, EJA835, EJA836
AT J02: 318610-166735
- INSTALL (1) NEW 575 JBOX 6055.1030 (JBOX3AS)
- INSTALL HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS (MID: 7663200)
- INSTALL. (3) 4-POS JBOX (MID: 7625900)
- INSTALL (6) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL (6) INSULATED CAPS (MID: 7630600)
- INSTALL CABLE TAG #
- INSTALL GRID #
AT J03: 318616-166751
- INSTALL (1) NEW 575 JBOX 6055.1030 (JBOX3AS)
- INSTALL HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS (MID: 7663200)
- INSTALL. (3) 4-POS JBOX (MID: 7625900)
- INSTALL (9) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL (3) INSULATED CAPS (MID: 7630600)
- INSTALL CABLE TAGS
- INSTALL GRID #
AT J04: 318607-166743
- INSTALL (1) NEW 575 JBOX 6055.1030 (JBOX15L)
- INSTALL HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS (MID: 7663200)
- INSTALL. (3) 4-POS JBOX (MID: 7625900)
- INSTALL (12) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL CABLE TAGS AØ-EJA416, BØ-EJA417, CØ-EJA418 IN NORMAL OPEN POSITION
- INSTALL CABLE TAGS
- INSTALL GRID #
AT J05: 318622-166725
- EXISTING HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS TO REMAIN 6055.1030 (JBOX15L)(MID: 7663200)
- CONNECT 3Ø UG PRIMARY LINE EXTNESION
- REMOVE (3) 200A DUST CAPS
- INSTALL (3) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL CABLE TAG #
AT J06: 318643-166758
- INSTALL (1) NEW 575 JBOX 6055.1030 (JBOX15L)
- INSTALL HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS (MID: 7663200)
- INSTALL. (3) 4-POS JBOX (MID: 7625900)
- INSTALL (12) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL CABLE TAGS
- INSTALL GRID #
AT J07: 318642-166760
- INSTALL (1) NEW 575 JBOX 6055.1030 (JBOX15L)
- INSTALL HH 4'8" X 7' X 5' W/ 2-3' SQ DOORS (MID: 7663200)
- INSTALL. (3) 4-POS JBOX (MID: 7625900)
- INSTALL (3) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL CABLE TAGS
- INSTALL GRID #
AT V01: 318610-166752
- EXISTING 1000 kVA PADMOUNT XFMR TO REMAIN
- CUT AND REMOVE (3) 1/0 LB ELBOWS CABLE EJA416, EJA417, & EJA418
- INSTALL (3) 12kV ELBOW KIT PER STD 6041.1000 (ELB10J)
- INSTALL GRID #
AT V02: 318614-166738
- INSTALL (1) 42" X 56"' TEMPORARY CONCRETE PAD (MID: 7807900)
- INSTALL (1) 25KVA PADMOUNT TRF (MID: 6247000)
- INSTALL (1) 12KV ELBOW KIT PER STD 6041.1000 (ELB10J)
- INSTALL (3) 6HOLE SECONDARY CONN. BARS (MID: 4842001)
- INSTALL GRID #
- CONNECT 3-RUNS OF CUSTOMER OWNED, INSTALLED, & MAINTAINED SVC CABLE
AT SW1: 318643-166757
- INSTALL NEW 422 SCADA VISTA SUBMERSIBLE SWITCH 6056.2010 (SSUBV22)
- INSTALL (3) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL (6) 750 ELBOWS (MID: 7802800)
- INSTALL CABLE TAGS
- INSTALL GRID #
- INSTALL SW # U86912
AT SW2: 318643-166761
- INSTALL NEW 422 SCADA VISTA SUBMERSIBLE SWITCH 6056.2010 (SSUBV22)
- INSTALL (3) LB ELBOWS 6041.1000 (ELB10J)
- INSTALL (6) 750 ELBOWS (MID: 7802800)
- INSTALL CABLE TAGS
- INSTALL GRID #
- INSTALL SW # U86913
AT SW3: 318650-166771
- EXISTING PADMOUNT SW# U1925 TO REMAIN
- DISCONNECT CABLES AØ13982, BØ13983, CØ13984 & REROUTE INTO SW1
- INSTALL NEW CABLES AØ-EJD321,BØ-EJD322,CØ-EJD323 FROM SW2
AT V03: 318641-166757
- INSTALL 48" X 48" X 38" HH MINIPAD W/ LVE ACCESS HOLE (MID: 9998668)
- INSTALL STEEL ACCESS COVER (MID: 7655300)
- INSTALL CABINET, GROUND RODS, & CABLES
- INSTALL GRID#
AT V04: 318640-166757
- INSTALL 48" X 48" X 38" HH MINIPAD W/ LVE ACCESS HOLE (MID: 9998668)
- INSTALL STEEL ACCESS COVER (MID: 7655300)
- INSTALL CABINET, GROUND RODS, & CABLES
- INSTALL GRID#
AT IP2
- CUSTOMER TO PROVIDE 5' X 10' WORK PITS TO EXPOSE PRIMARY CABLE IN CONDUIT
- BREAK AND INTERCEPT 6" CONDUIT, REROUTE NEW 6" CONDUITS TO SW1 & SW2
- PULL BACK CABLE FROM SW3, REROUTE INTO SW1
AT IP3
- CUSTOMER TO PROVIDE 5' X 10' WORK PITS TO EXPOSE PRIMARY CABLE IN CONDUIT
- BREAK AND INTERCEPT 6" CONDUIT, REROUTE NEW 6" CONDUITS TO SW1 & SW2
AT EM1 & EM2
- INSTALL 4" ELECTRONIC MARKER BALL (MID: 7668501)
SPAN SPECIFIC NOTES
- REFER TO ONE LINE DIAGRAMS AND TABLES FOR INSTALL
101141447Owner / Developer Contact Info
officeATTN:
SOLERA MANAGER, LLC
10900 NE 8TH ST. SUITE 1200
BELLEVUE, WA 98004
DALTON ARNDT 253-606-0715
00 1"2"
00 50'100'
CIRCUIT FEED ADDED: 135'
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
N/A
800AMPS
N/A
246.73 kW
543A
3.6% @ V01
2.5% @ V01
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 3/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
V02
318614-166738
25KVA 120/240V
6247000
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01 318620-166726 55 H1 PSE Equip #
LUCAS KNAUSS 253-313-8029 1/25/22
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 3/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Fabian Gomez 3/17/2022
LUCAS KNAUSS 253-313-8029 1/25/22
MFP23001384
J
J318557-166687
318622-166725
318605-166743
318614-166738
25 kVA 120/240 V
PSE INST. 1-RUN 3Ø PRI. 12KV1/0
UG JKT CABLE ±640'
(AØEJA837)
(BØEJA838)
(CØEJA839)
PSE INST. 1-RUN 3Ø PRI.
12KV1/0 UG JKT CABLE ±75'
(AØEJA843)
(BØEJA844)
(CØEJA845)
PSE INST. 1-RUN 1Ø PRI. 12KV1/0
UG JKT CABLE ±80'
(AØEJA846)
PSE INST. 1-RUN 3Ø PRI. 12KV1/0
UG JKT CABLE ±290'
(AØEJA416)
(BØEJA417)
(CØEJA418)
PSE INST. 1-RUN 3Ø PRI. 12KV1/0 UG JKT CABLE ±310'
(AØEJA834)
(BØEJA835)
(CØEJA836)
PSE INST. 1-RUN 3Ø PRI. 12KV1/0 UG JKT CABLE ±100'
(AØEJA840)
(BØEJA841)
(CØEJA842)
J
318608-166737
J318556-166708J 318650-166771
PSE INST. 1-RUN 3Ø PRI. 12KV1/0
UG JKT CABLE ±420'
(AØEJA837)
(BØEJA838)
(CØEJA839)
PSE INST. 1-RUN 3Ø PRI. 12KV
750KCMIL UG CABLE ±210'
(AØEJD321)
(BØEJD322)
(CØEJD323)
RE-USE EXISTING 3Ø PRI. 12KV
750KCMIL UG CABLE
(AØ13979)
(BØ13980)
(CØ13981)
PSE INST. 1-RUN 3Ø PRI. 12KV
750KCMIL UG CABLE ±40'
(AØEJD318)
(BØEJD319)
(CØEJD320)
PSE INST. 1-RUN 3Ø PRI. 12KV1/0
UG JKT CABLE ±60'
(AØEJD315)
(BØEJD316)
(CØEJD317)
PSE INST. 1-RUN 3Ø PRI. 12KV1/0
UG JKT CABLE ±70'
(AØEJD312)
(BØEJD313)
(CØEJD314)
318610-166752
1000 kVA 277/408V (ABC)
318641-166756
U86912
318642-166756
U86913
318642-166758
318641-166758
RE-USE EXISTING 3Ø PRI. 12KV
1/0 UG JKT CABLE ±40'
(AØEJD382)
(BØEJD383)
(CØEJD384)
J
J
318640-166757
318641-166757LVE
LVE
J
JJ
J318557-166687
318608-166737
318622-166725
318614-166738
25 kVA 120/240 V
318610-166752
1000 kVA 277/408V (ABC)
318605-166743
318556-166708
CUST. PROVIDED 4' X 4' - 6"
BEDDING OF CRUSH ROCK
CUST. PROVIDED
4' X 4' WORKPIT CUST. PROVIDED 11' X 9' WORKPIT W/
6" BEDDING OF CRUSH ROCK
CUST. PROVIDED 11' X 9'
WORKPIT W/ 6" BEDDING
OF CRUSH ROCK
CUST. PROVIDED 11' X 9' WORKPIT
W/ 6" BEDDING OF CRUSH ROCK
CUST. PROVIDED
4' X 4' WORKPIT
CUST. PROVIDED
4' X 4' WORKPIT
±1
9
0
'
±6
5
'±600'±60'±21
0
'
90°
R=48"
45°
R=48"
EXISTING 4" CONDUIT
PSE INST.1-4" DB120 DISCONTINUOUS PVC
CONDUIT ±670' IN CUST. PROVIDED TRENCH
PSE INST.1-4" DB120 DISCONTINUOUS PVC
CONDUIT ±190' IN CUST. PROVIDED TRENCH
PSE INST.1-4" DB120 DISCONTINUOUS PVC
CONDUIT ±65' IN CUST. PROVIDED TRENCH ±45'PSE INST.1-4" DB120 DISCONTINUOUS
PVC CONDUIT ±60' IN CUST. PROVIDED
TRENCH
J
J
318641-166756
U86912
318642-166756
U86913
318642-166758
318641-166758
CUST. PROVIDED
9' X 11' WORKPIT
CUST. PROVIDED
5' X 10' WORKPIT
J45°
R=48"
PSE INST.1-4" DB120 DISCONTINUOUS
PVC CONDUIT ±380' IN CUST.
PROVIDED TRENCH±360'±90'PSE INST.1-4" DB120 DISCONTINUOUS
PVC CONDUIT ±30' IN CUST. PROVIDED
TRENCH
CUST. PROVIDED
13' X 11' WORKPIT
PSE INST.1-6" DB120 DISCONTINUOUS PVC
CONDUIT ±50' IN CUST. PROVIDED TRENCH
PSE INST.1-4" DB120 DISCONTINUOUS PVC
CONDUIT ±270' IN CUST. PROVIDED TRENCH
FIELD
BEND ±70'EXISTING 6" CONDUIT
±70'±5
0
'
PSE INST.2-4" DB120 DISCONTINUOUS PVC
CONDUIT ±50' IN CUST. PROVIDED TRENCH
PSE INST.2-4" DB120 DISCONTINUOUS PVC
CONDUIT ±70' IN CUST. PROVIDED TRENCH
45°
R=48"
CUST. PROVIDED
9' X 11' WORKPIT
PSE INST.1-4" DB120 DISCONTINUOUS
PVC CONDUIT ±20' IN CUST. PROVIDED
TRENCH
PSE INST.1-6" DB120 DISCONTINUOUS
PVC CONDUIT ±5' IN CUST. PROVIDED
TRENCH
PSE INST.1-6" DB120 DISCONTINUOUS
PVC CONDUIT ±5' IN CUST. PROVIDED
TRENCH
±15'
318640-166757
318641-166757LVE
LVE
CUST. PROVIDED
7' X 7' WORKPIT
CUST. PROVIDED
7' X 7' WORKPIT
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
NEW CABLE DIAGRAM
NOT TO SCALE
101141447Vault & Equipment Table
Work
Location
Grid
Number
Vault Size
& Cover
Type & Size
Equipment
In Vault
Primary Bushings Transformer
ID Numbers
(Company ID)
ASBUILT INFORMATION
Foreman-CompleteLBDC
J02 318589-166731 JBOX15AS
(5'x7'x6')
(3) 4-POS J-BUS
(MID 7625900)6 6
J03 318605-166743 JBOX15AS
(5'x7'x6')
(3) 4-POS J-BUS
(MID 7625900)6 6
J04 318608-166737 JBOX15L (5'x7'x6')(3) 4-POS J-BUS
(MID 7625900)9 3
V02 318614-166738 9996109
(8'x8'x3.167')25KVA 120/240v 1 1
J06 318643-166758 JBOX15L (5'x7'x6')(3) 4-POS J-BUS
(MID 7625900)12
J07 318642-166760 JBOX15L (5'x7'x6')(3) 4-POS J-BUS
(MID 7625900)3 9
SW1 318643-166757 687 VAULT W/
SWITCH RACK
(2) 200A POS &
(2) 600A POS 9 3
SW1 318643-166757 687 VAULT W/
SWITCH RACK
(2) 200A POS &
(2) 600A POS 9 3
V03 318641-166757
42X48X38
Unistrut HH
Matid: 7663001
LOW VOLTAGE
ENCLOSURE
CABINET
--
V04 318640-166757
42X48X38
Unistrut HH
Matid: 7663001
LOW VOLTAGE
ENCLOSURE
CABINET
--
NEW CONDUIT DIAGRAM
NOT TO SCALE
Primary Cable & Conduit Table (Foreman to Complete)
LOCATION CONDUIT PRIMARY CABLE
QTY OF LUBE (gal.)AS BUILT INFORMATION
From To Size
(in)
Qty
Design
Length
(ft)
Actual
Length
(ft)
TYPE BENDS PULL
(lbs)
PULL
Rev
(lbs)
Cable
Size Design
Length (ft)
Actual
Length
(ft)
CABLE NUMBERS MANUFACTURING INFORMATION FOR FEEDER CABLE ONLY
Check applicable box
DB120 HDPE SCH 80 90°45°22°11°A B C Manufacturer Compound Year Tape CN #4/0 NEU Design As Built Actual Amount Installed
(Conduit & Cable)
J01 J02 4"1 270'X 1 1 674 517 1/0 310'EJA834 EJA835 EJA836
J02 J03 4"1 600'X 170 170 1/0 640'EJA837 EJA838 EJA839
J02 EM2 4"2 50'X SPARE
J03 J04 4"1 65'X 120 120 1/0 100'EJA840 EJA841 EJA842
J04 V01 2"1 55'X 2 111 110 1/0 90'EJA843
J04 V02 4"1 50'X 1 132 132 1/0 80'EJA846 EJA847 EJA848
J04 EM1 4"2 70'X SPARE
J04 IP1 4"1 35'X 2
281 232 1/0 290'EJA416 EJA417 EJA418
IP1 J05 4"1 EXIST
J03 J06 4"1 380'X 1 337 254 1/0 420'EJD309 EJD310 EJD311
J06 J07 4"1 30'X 37 37 1/0 40'EJD312 EJD313 EJD314
J06 SW2 4"1 20'X 84 84 1/0 40'EJD315 EJD316 EJD317
SW1 SW2 6"1 5'X 257 257 750 40'EJD318 EJD319 EJD320
SW1 J06 4"1 5'X 1 87 87 1/0 40'EJD382 EJD383 EJD384
SW1 IP2 6"1 90'X 1 --750 RE-USE
EXISTING 13979 13980 13981
SW2 IP3 6"1 70'X
550 490 750 210'EJD321 EJD322 EJD323
IP3 SW3 6"1 EXIST
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 4/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
3
4
4
3
2
2
WAY
1
1
SIDE
OPERATOR
SIDE
CONNECTION
CABLE
VISTA MODEL 4222-600 AMP
PADMOUNT 422 VISTA SCADA SWITCH CONNECTION
DIAGRAM, POST-CONSTRUCTION, SW01
SCALE: NONE
U86912
C - 13981
B - 13980
A - 13979
C - EJD314
B - EJD313
A - EJD312
MO
MO
LVE
INSTALL FAULT
INDICATORS
3
4
4
3
2
2
1
1
1 Ø TRIP
1 Ø TRIP
150E
150E
2-200 AMP
J06
C - EJD320
B - EJD319
A -EJD318
SW02
3
4
4
3
2
2
WAY
1
1
SIDE
OPERATOR
SIDE
CONNECTION
CABLE
VISTA MODEL 4222-600 AMP
PADMOUNT 422 VISTA SCADA SWITCH CONNECTION
DIAGRAM, POST-CONSTRUCTION, SW02
SCALE: NONE
U86913
C - EJD323
B - EJD322
A - EJD321
MO
MO
LVE
INSTALL FAULT
INDICATORS
3
4
4
3
2
2
1
1
1 Ø TRIP
1 Ø TRIP
150E
150E
2-200 AMP
J06
C - AFB316
B - AFB315
A - AFB314
SW01
C - EJD320
B - EJD319
A -EJD318
SW03
TOTAL 2" DB120:55'
TOTAL 4" DB120: 140'
TOTAL 4" SCH.80:1,560'
TOTAL 6" DB120:5'
TOTAL 6" SCH.80:160'
TOTAL 1Ø 1/0: 90'
TOTAL 3Ø 1/0:1,960'
TOTAL 3Ø 750:250'
SECONDARY CABLE & CONDUIT TABLE
LOCATION CABLE Assumed
Lot Corner
CONDUIT VOLTAGE
DROP
VOLTAGE
FLICKER ASBUILT INFORMATION
SIZE LENGTH
Design
(ft)
SIZE LENGTH
Design
(ft)
BENDS
Foreman - Complete
FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable)
SW2 V03 UMBILICAL 20 3 5 N/A N/A
SW1 V04 UMBILICAL 20 3 5
LUCAS KNAUSS 253-313-8029 1/25/22
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
J. FELLER 253-204-1990 1/25/22
J. FELLER
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 4/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Fabian Gomez 3/17/2022
LUCAS KNAUSS 253-313-8029 1/25/22
MFP23001384
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
10'4'8"8'3"8'8'11'6'6"8'3"10'8"4'22'4'11'8"9'
(3) 4" DB120 CONDUITS
(3) 4" DB120 CONDUITS
(1) 4" SCH.80 CONDUIT
(1) 6" SCH.80 CONDUIT
(1) 6" DB120 CONDUIT
TO BE INSTALLED
UNDER WO# 105099860
(1) 6" SCH.80 CONDUIT
5'5'5'7'
7'
7'
7'
Communications
Primary Power
Cables or Conduit
Excavated Dirt Pile
ROADSIDE
Final Grade
24" Min
12" Min
Separation
36"
Min
Cover
48"
Max
Backfill
(No rocks over 10" diameter)
Separation
12" Min
Gas
4" Sand Bedding
32" Typical
(Power, Gas, and
Communications)
JOINT TRENCH DETAIL
Primary-Mainline Gas & Communications (NTS)
Separation
12" Min
6" or 12" Min Sand Shading after Compaction
- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.
Trench and backfill requirements for primary electric line extension trenches (No PSE gas)
- A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.
FLOW DIRECTION
LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL,
SECURE WITH PEA GRAVEL BAGS.
6'
3'
8"
TECHNIQUES FOR EROSION AND SEDIMENT CONTROL
SILT FENCE DETAIL
Not to Scale 0150.3200
ASPLUNDH CONSTRUCTION CORP. - QA/QC T. MYER
4'
TRANSFORMER CABINET
FOOTPRINT
1Ø PRIMARY CABLE
IN 1-2" PVC CONDUIT 4'
TOP VIEW
36" MIN COVER
6" CRUSHED ROCK BEDDING
TEMPORARY CONCRETE LID
1Ø PRIMARY CABLE
2" PVC CONDUIT
TEMPORARY CONCRETE
PAD
COMPACTED
BACKFILL
CUSTOMER SUPPLIED
SECONDARY PVC
TEMPORARY XFMR INSTALLATION DETAIL V02
Not to scale 6315.1000
101141447Field Face
Quadrant
Climbing
Space
Road Face
Quadrant
Climbing
Space
5" Min
CL
LC
Direction of Vehicular Traffic
TOP VIEW
Standoff Bracket
15" Min Length
Conduit Clamp
Conduit
CONDUIT RISER PLACEMENT DETAIL (P01)
SCALE: NONE
4'x4' Work Pit
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
D. BRINKMANN 253-234-6445 07/02/21
D. BRINKMANN -09/28/21
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 5/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Cables should enter the vault so that all of
the cables will lay in the same direction.
TOP VIEW
J- BOX CABLE ENTRY DETAIL
Not to scale
CONDUIT ENTRY DETAIL @ J02
NOT TO SCALE
X
O - EX. KNOCKOUT
X - NEW KNOCKOUT
X
CONDUIT ENTRY DETAIL @ J01
NOT TO SCALE
O
CONDUIT ENTRY DETAIL @ J04
NOT TO SCALE
O
X
X
X
X
X
Overflow
Filter fabric walls for
Catch Basin Grate
dewatering sedimentCollected Sediment
Catch Basin Insert
MID 9995728
Filter fabric skirt
Secured with grate.
EROSION CONTROL
NOT TO SCALE
UTILITY POLE EROSION CONTROL DETAIL
Not to scale Adjacent to flowing ditches or bodies of water
TOP VIEW
FLOWING DITCH or BODY OF WATER
SLOPESLOPE
SECURE BOTTOM OF FENCE
WITH GRAVEL BAGS
PLACE STRAW MULCH
ON DISTURBED AREA
INSTALL SILT
FENCE AROUND
POLE EXCAVATION
EXCAVATED OR
AUGERED HOLE
POLE
2"
Excavation - 19-1/2 cubic yards
SIDE VIEW
5'-4"Crushed
6"
Rock
TOP VIEW
9'
11'
7'-0"
4'-0"
1'
4'-8"
4,750 lbs
2,490 lbs
VAULT & EXCAVATION DETAIL
Not to scale 6051.1500
CONDUIT ENTRY DETAIL @ J06
NOT TO SCALE
X
X
XX
CONDUIT ENTRY DETAIL @J03
NOT TO SCALE
X
X
X
687 SWITCH VAULT EXCAVATION DETAIL
SCALE: NONE MID # 9995185 OR 9996177
NOTE:
The Top Cover shall be leveled and adjusted to Final Grade
using the Adjustable Bolts. This Installation is for Pavement
or Sidewalks only.
TOP VIEW
SIDE VIEW
Excavation - 50-1/2 cubic yards
6"
Crushed
Rock
2" to 3"Final Grade
(Pavement)
7'6"
to 7'-7"
Adjustable Cover
(See NOTE Below)
8"
Base Section
6,400 lbs
8'-8"
Top Section
2,390 lbs
Center Section
6,640 lbs
4'-10"
6'-8"
8"
13'-0"
11'-0"
3,270 lbs
Cover Slab
6'-10"
8"
@SW1, SW2
PARTIAL PLAN DETAIL
SCALE: 1"=10'
CONDUIT ENTRY DETAIL @ J07
NOT TO SCALE
X
XXX
SIDE
VIEW
EXCAVATION:
5-1/3 CUBIC YARDS
Rock
Crushed
6"
3'-6"
2"
7'-0"
7'-0"
VIEW
38"
54"54"
TOP48"48"
LVE ENCLOSURE VAULT DETAIL @V03, V04
Not to scale
LUCAS KNAUSS 253-313-8029 1/25/22
J. FELLER 253-204-1990 1/25/22
J. FELLER
ASPLUNDH CONSTRUCTION CORP. - QA/QC T. MYER
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
T. NGUYEN 253-437-6703 07/02/21
D. BRINKMANN 253-234-6445 07/02/21
D. BRINKMANN -09/28/21
RW-123894 RENTON
SOLERA
SCHEDULE 73
2828 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 101141447
AS NOTED 5/5
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Fabian Gomez 3/17/2022
LUCAS KNAUSS 253-313-8029 1/25/22
J. FELLER 253-204-1990 1/25/22
J. FELLER
MFP23001384