NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINTS) (315' MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C--443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX. PIPE SIZE - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
A,
B,
.C,
D,
Er
48" MH
48''
1 5" MIN.
I 5"MIN
1 2+4" MIN,
1 21" I.D.
54" MH
54"
1 8" M[N.
5-5" MIN,
24" MIN.
1 24" ].D.
5T MH
60"
1 B" MIN.
1 6" MIN.
1 42" MIN.
1 30" I.D.
NOTES;
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS,
2. STEPS ARE TO BE rN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5, ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR QN1.1 BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEW]EP MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL: COLOR OF COATING SHALL BE WHITE.
6. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE VATH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12'
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
� x o Sm. PLAN - 400.1
■ PUBLIC WORKS STANDARD SANITARY MANHOLE
DEPARTMENT
tn�,T SEPTEMBER 201I
STANDARD SANITARY MANHOLE
NTS
RECESSED Not to Scale
LIFT POCKET
o t� FRAME
n 3/4" LETTERING "SEWER" -O" I OIAMETER I 2'-0„
SEWER (2) BOLT SOC. (ALLEN HEAD)
5/5" -- 11 X 1,5 STAINLESS
a E� rSTEEL
REF. PART #00,381177
1 -3/16'
10-1/z" 8" CLASS "B"
5/8„ ASPHALT
1/4" 12-1/2"� -
-T1-1/8'
2-1 /4" BOLT DETAIL
CAST IRON RING AND COVER
45' (1/8) BEND
45' (1/S) BEND
SAND OR
EXPANDABLE
FOAM
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES,
1. 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC.
No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A V-0" THICK, 2'-O" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER,
STD. PLAN - 403.1
• PUBLIC WORKS ill OR 6" CLEANOUT AR4YELr
DEPARTMENT FOR SANITARY SEWER MAIN
ADJUSTMENT RINGS (2" MIN,)
SEE NOTE 6
MORTAR JOINT(S) {3/8" MIN.}
SEE NOTE 5
� 6
p
SE 1/4, SEC. 03, TWP. 23N, RGE. 05E., W.M.
MANHOLE FRAME AND COVER
PER DRAWING 401,
6.,
ti
24" 1
io
IF I
12"
w
m
d
>r
V j
4" T 54"
b •� v
a
as 'r o a 7
V 7 v b
o 9 v
4" MIN. TO
12" MAX.
D
G.,
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED-
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A
COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ❑NLY. BRICKS SHALL
BE STAGGERED TO CREATE A RUNNING BOND OR T/2 BOND.
THE USE OF SHIMS 15 PROHIBITED.
7, SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED {SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER
MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE,
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL
BOOTS OR APPROVED EQUAL.
IT. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF
12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS
POURED AT GRADE- ;N PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING-
PUBLICWORKS SANITARY MANHOLE STD. PL&N - 40D.2
DEPARTMENT SHALLOW
SEPTEMBER 2011
STANDARD SANITARY SHALLOW
NTS
W (SEE NOTE 7) LIMITS OF PIPE ZONE
V1111111111i/ -oll
BEDDING MATERIAL FOR
SANITARY SEWER PIPE O.D. OF PIPE
(SEE NOTE 5)
FOUNDATION LEVEL
�v
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-013 OF THE
STANDARD SPECIFICATIONS.
5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)r
OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER A5 TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STIR. PLAN - 40S
■ PUBLIC WORKS PIPE BEDDING "PP
"5 DEPARTMENT FOR SANITARY SEWERS a
wti, wre 6rATE
8" OR 6" CLEANOUT PIPE BEDDING FOR
FOR SANITARY SEWER MAIN SANITARY SEWERS
P=
E
NTS 6 NTS
An Engineering Services Company
11255 Kirkland Way, Suite 300
Kirkland, WA 98033
p. 425.827.2014 1 f. 425.827.5043
Civil I Structural I Planning I Survey
paceengrs.com
EOLTHOLES - 3 PLCS
EQUALLY SPACED 120'
APART ON 23 1/16' (586mm)
DIA B.C. (SEE DETAIL)
t�
R E NTDN
SEWER
COVER & FRAME
PLAN VIEW
25' DIA.
C635mm7I'
3J4'
[191nn] }
8 3/4' L 2 1/2'
I222mml 164mm7
TYP
COVER SECTION VIEW
26 112' ILIA
L673mm7
25 1I4' DIA
1/4' (bmm) DIA C27mm]
NEOPRENE GASKET I r
6'
f 115E aril
5/8' 23 3f8' DIA CL OPEN
C16mm] E594mm]
27 5fI6' DIA
C694rlml
34 1/8' DIA
COVER BOTTOM VIEW
(3) BLT S{]C. CALLEN HEAD)
5/8-11 x 1.5 SS
RUBBER WASHER
EON BOLTING DETAIL
1/4'
I6mn] E27nrr]
J f
E3nm]
II8'
CR3m n]
GASKET GROOVE DETAIL
1867mm] NOTES;
FRAME SECTION VIEW 1, ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC- No, 3717C1 OR EQUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"), OR WATER (SPECIFY "WATER").
STD. PLAN - 401
PUBLIC WORKS MANHOLE FRAME AND COVER
DEPARTMENT
DECEMBER 2008
MANHOLE FRAME AND COVER
NTS
Al, L 1L,RN5 SHALI.
By MEANS OF A WYE WITH CLEANGUT AND
45' BEND_ TWO 45' BENDS SHAH NOT BE
4" 13END AS REQUIRED (NO MCRE
ACCEPTABLE- (SEE NOTE 11)
THAN 45 BEND). EVERY 24D 4" CLFANOUT WYE 'MTti
CHANGE IN DIRECTION OR GRADE 45. BEND AND PLUG.
WILL REQUIRE A SuprACE (SEE NOTE 11)
CLEANOUT WYE. (SEE NOTE 11)
7
s
a
Hr+USF
o
I
HOUSE
�I
HOUSE
oI
HOUSE
3-0"
FAIN,
I:
4" SEINER PIPE
SURFACE CLEANGUT
6"x 6-.6" WYE
(SEE STD PLAN - 407)
�_ �" SURFACE v
CLEANOUT
WYE
(TYP]CAL)
A" TEST TEE WITH
�RL13C
4" SEWER PIPE, SEE NOTES 2
AND 3- MINIMUM LINE 512E FOR
4" WYE WITH
rACE UP
❑T1iER THAN 5INGLE FAMILY IS 6••
L1
[TYpiGAL)
PROPERTY LINE CLFANOUT
PROPERTY LINE
3' MIN. u U
fi"w 4" REDUCER ,a
?
F F
(TYPICAL) F
MAIN SEWER LINE
NOTES:
x
IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
1. Prior to lnstailbtlan of o sanitary sewer conneaflon, a side -sewer
x
FL000 LEVEL RIMS LOCATED 9ELOW TiiE ELEVATION
pmm.t must he. purchessd from the City of Renton Puhllc Works
o
OF THE NEXT UPSTREAU MANHOLE COVER OF THE
Department.
PUBLIC SEWFIt SYn TEM. A BACKFLOW PRFvENTION
?t5
z DEMCE SUCH AS CLEAN CHECK EXTENDABLE
q BACKWATER VALVE OR APPROVED EQUAL SHALL BE
2. Types of pipe and ri tingB. treat con be used for sonlivy, sewers
`n
INSTALLED
ghdll ba dppravcd by the Department of Public Works. Rubber or
m
nevprene gaskets v5 specified by the manufacturer, shall be
- 4" FLEXIBLE COUPLING (FERNCO OR EQUAL)
used an pints.
TEE OF APPROPRIATE SIZE
- "RELINER" BRAND STAINLESS
STEEL ADJUSTABLE CLAMPING
BRACKETS OR APPROVED EQUAL
90' BEND
3/4 THE DIAMETER OF
THE DOWNSTREAM PIPE
NOTES -.
AN TA 1. SANITARY SEWER MANHOLE DROPS ARE ONLY TO 6E USED UPON
APPROVAL BY THE WASTEWATER UTILITY SECTION.
2, ALL PIPES AND FITTINGS SHALL BE SIMILAR SIZE AND MATERIAL
AS INCOMING MAINLINE.
3. MINIMUM S1ZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE
60" DIAMETER.
4. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR,
KOR-N-SEAL BOOTS OR APPROVED EQUAL.
5. WITHIN A 60DIAMETER MANHOLE THE MAXIMUM ALLOWABLE DIAMETER
OF THE INSIDE DROP PIPING IS 12'. INSIDE DROPS EXCEEDING 12' IN
DIAMETER OR MULTIPLE DROPS SHALL BE REVIEWED BY THE WASTEWATER
UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE.
6. "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS
OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 8" OF
BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE.
IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS
SHALL BE INSTALLED WITH A MAXIMUM SPACING OF 4 FEET
ON CENTER. BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS
STEEL EXPANSION BOLTS, MIN. 2 EACH AT CONNECTION POINTS.
STD. PLAN -- 4D8.2
PUBLIC WOj?xs INSIDE DROP CONNECTION ?rlavw;
DEPARTMENT FOR SANITARY MANHOLE j
° oa
INSIDE DROP CONNECTION
FOR SANITARY MANHOLE
-
4 NTS
FAW
2 . O
w SURFACE CLf ANOLI7
3 A minimum grade of 29. (1/4" per foot) must he maintained �1 /J
m � a"x i"x4" WYE with a" p[pe. In the event a 2% ordde GdnnDt be maintained, the
owner must sign a City of Renton grade release form and then
4" PIPING can install 8" pipe at a grade cf 17.
BAN
80ILDINS DRAIN FOR 4_ For inspection of side sewer, [❑II 24 hours In advance- The
LOW ELEVATION HOUSE Inspectlon phone number is on the 51de sewer permit. Site
must be ready for inr,pec Llon and represnntotiva on site when
Inspector arrives ❑t ❑ppainled time- Slde sewer ❑nd stub shall
be tested per Clty speciilcafivns Make the connection of the
M A1N TO pROPEit TY LINE S'-0'• house_ ❑o not ba❑kflli me ditch until approval is given by the
PROPERTY LINE FROM THE HOUSE BUILDING DRAIN Inspector. Final approval will be granted oFLer the e.isfing septic
SIDE SEWER 9UIL]71NG SEWER Z_8• tunas has been pumped out ana Filled with sond-
3'-O'•IAIN. TO 3-0 5- Inst D1l side sewer with 2' minimum cover. 15" cover is allowed O
_ at the house if outlet is shallow,
U)
I 5. If side sewer stub is nut avalfeble. The awner en¢ft be
rNn m rn a m > ¢ reap Dn¢ible far its instal per atdr,ddrd drawing 406.1, All
• inm - u, aos i n '
A A - work within street right-of-w❑y shall be done by o Ilc°nsed ❑nd
o n m? % x A n o bonded cdretroctar, z
o
e a ` mo nt r°tn m n + o n P 7- All work shall ba uccompi!rhed in accordant[ Wlth the Washingtan
Fn n o m r m? " a a r" nn Indushial Salaty and Health Act (V511A) Lu
rn p n z
JN I� N uI a A vl c c 8. A!l trench restoration !ar sloe sewers in the public right-Df-way
y u shell canforrn is the most current trench restprctlon
q, z rn m n r-piremants as In the Rerntan Standard ➢mwings. 'Y`
,m I arjrnr z a
o onun 9 Ail bullding sewer and side sewers shall have beading Inuj
ay C y otrordodta with stonddrd drawing 405_
A x 10. There shall be a minimum at Foot hvos and seporasion het wean RECORD DRAWINGS
Au ry s❑nii❑ry aide sewers ❑nd water services and ❑ minimum 5 Taal
• horlrpntai separaflon between Santiary Side sewers and al other
c1 util itres. W D
11. The aledn❑•ic at 7. The clear -Way shah be installed per S-397506
CALL FOR LOGAl10N5 BEFORE YOU DIG Standard Plon 4D7, The clean out of the buZoing shall be
49HR LOCATORS 1-800-424-5555 Installed to surfoce rade. All alher cle❑noute shall be installed
tc within 12" of the 9arfoce.
a Lu
TYPICAL BUILDING SEWER SM. PLAN - 408.2 IN COMPLIANCE WITH CITY OF RENTON STANDARDS U)PLTBLIC WORKS FROM PROPERTY LINE TO
DEPARTMENT BUILDING CONNEGTION
_•�„ AUGUST 2013
TYPICAL BUILDING SEWER FROM Q
PROPERTY LINE TO BUILDING CONNECTION IL
NTS
SURVEYED:
DESIGNED:
DRAWN:
1 REVISED PER CITY COMMENTS DATED 10/4/2017 BM 10/5/17 CHECKED:
NO. REVISION BY DATE APPR APPROVED:
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CALL BEFORE W
YOUD;G 811
UNDERGROUND (A)
DATE: O
CITY OF FIR GROVE PARK SEWER EXTENSION 2017/10/09
RENTON
NOTES & DETAILS FlELDBOOK:
PAGE:
r DRAWING NO:
Planning/Building/Public Works Dept. 5325 NE SUNSET BLVD, RENTON, WA 98049 C3.02
CID rDfN%l= DADA CC1A/CD CYTCAI42Ir1Al SHEET: i+ OR LL
PACE JOB NUMBER: 17430