Loading...
HomeMy WebLinkAboutR-422942L; i Q z w A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON rn RIM=22.06 0 _, SD', ° .. _w , UNWHY LINK WtSI ' CV IE=19.91, 8 D.I. N °2 s �k sD ''� _ - w :'I- - 2�AS N IE=16.44, 6"PVC E x ti' sD w - ��1� s GAS IE=16.36, 6"PVC W a AS HALT w As = s I � 2+46 _GAS o „NO PARKING" -23_ SD. o� _ - w -N i 2T�'I �� �7 °_ ss �� _ _ _ - - - - - - - GAs GAS N:174,13 .93 ��� sD: a . a _ _ w - a S■ " " _ - p _ GAS E:1,297,595.31JCE "NO PARKING" gP SD ._. _ _ w - s _ s� ' 2� 2+p _ GAs CHAiiv� •. - - I w o „NO PARKING" 5 e _ - S J - 2 7'S '6 - BP gP a� _ _ _ w w I 2-� - - 23 x ti-S IORM VAULT W/OIL WATER SEPARA TOR P w - 22- - - �8 � ss _ �� � o TEL - 3 LIDS. UNABLE TO OPEN 2 OUTER LIDS _�ASPHALT 2� TEt RIM=24.08 Sig TOP OF BAFFLE=21.78 BP �° SS �� TELL TOP OF VERT. TEE=21.55, 'o / - SS - i i p L TEL - /Lu s �22 5� z BOTT. OF VERT. TEE=18.58, 12 PVC W Sstir ' - QE - ti TOP OF PIPE=20.9f, 12"PVC E, ss UNABLE TO MEASURE IE ss ❑ / x SSWATER LEVEL=19.98 �'y TE - / Q BOTT. OF STRUCT.=17.53 s 2 / _ 6 L �� 4E 4E1 SEE PROFILE 12TH FL ON SHEET C3.6C L / x 22 �? 2�� TO ESTABLISHED ELEVATIONS ON THE 2113 0+00 _ PROPOSED CURB AND GUTTER FLOWLINE. moo- TES x 22 I - I I \ / °T TPN 3340402755 AZULq PROPERTIES LLC N:174,341.05 N:174 341.62 \ \ Asa E-1,297,355.29 9 - (IS aS aS I ; ; ur,2 E:1,297,362.28 \"�S I Ias S / l 61 22.56 XG o I / \ o e `n Fo \� 22.93 x X tip' i ti6 \ I cn x \ \ C/) / ASPHALT k W I -tea I � �03 Ro o VACATEDREWNO n CITY 4668 5 R 707150313 STORM CATCH BASIN N199 E RIM=23.55 o - IE=18.02, 12 "CPP S f i I / / o )LE I - - 25¢ IE=17.97, 12 CPP W I i I I - - - y'Y;: 0 HOSE I 10' BAY _ = 818 12.36 I / DOOR FORCEMAIN E Py 1�01� 2396 2 TPN 33410402935 z BALLESTRASSE 2 ROY+REi+GLORIA EMPTY CONDUIT L0 o \ Q � 2X� &4X2 SD _ m C) 3.28 ; \ C:) \ / RD fig•. F F--24. 04_ x STORM CATCH TYPE I RIM=23.66 IE=19. 65, 12 "CPP N C, IE=19.76, 12"CPP E Lj 35° IE=19.76, 12 CPP S Q r, IE=20.38, 6"PVC W zo ( I - --- t- SDI STORM CATCH BASIN &8" OAK ' TYPE 1 7 55 ASPHAL �\ g I I // \\ I �� \\ I I / L RIM=22.55 I , IE=20.28, 6"PVC W IE=20.02, 12"CPP N ti 13 ❑9 I\ I I \ \ / I ; , r- -I \ GAP i \ I I- -I Q I I \ I L -I \I \ 22 zo I i , `� \ c� w / /I 1� \ - r "WATER LINE" Sp J SD RED "HAZARD" x CJ_ w x ti2 O w e o_ � N w / 6 HALT _ x tititi "NO PARKING"; _ w t.% �" ° NO �,� ° 1196 e$ TELEPHONE RISER VHOI F GRADING AND STORM DRAINAGE PLAN (PUBLIC) SCALE: 1"=20' • Call 811 • ® two business days before you dig NO. REVISION SURVEYED: DESIGNED: DKM/RJJ DRAWN: KLK/DKM CHECKED: DCD BY DATE APPR APPROVED: DCD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVO 1988 HORIZONTAL: NAD 1983/1991 DATUM NORTH HORIZONTAL SCALE: 1"=20' 20 0 20 40 CITY OF R RENTON vugv Planning/Building/Public Works Dept. LEGEND PROPOSED FEATURES - SD STORM DRAIN PIPE, INSTALL PER STD PLAN 220.00 OR 220.10/C3.3C, AS APPROPRIATE - ROOF DRAIN PIPE, INSTALL PER STD PLAN 220.00 OR 220.10/C3.3C, AS APPROPRIATE - GRADE BREAK TYPE 1 CATCH BASIN, PER STD PLAN 200.00/C3.3C TYPE 2 CATCH BASIN, PER STD PLAN 201.00/C3.3C ROOF DRAIN CLEANOUT, PER STD PLAN 226.00/C3.3C f:7l I■ 9 GENERAL NOTES 1. SEE APPLICABLE GRADING AND STORM DRAINAGE NOTES ON C3.2C 2. SLOPES NOT TO EXCEED 3H:1V 3. TYPE 1 CATCH BASINS SHALL BE TOPPED WITH LOCKING SOLID LIDS PER STD PLAN 204.10/C3.4C, UNLESS OTHERWISE NOTED 4. TYPE 2 CATCH BASINS SHALL BE TOPPED WITH LOCKING SOLID LIDS PER STD PLAN 204.40/C3.4C, UNLESS OTHERWISE NOTED 5. CONTRACTOR TO FIELD -VERIFY LOCATION OF EXISTING UTILITIES. 6. SEE ROOF DRAINAGE SYSTEM PROFILES ON SHEET C3.6C 7. SEE STORM DRAINAGE SYSTEM PROFILES ON SHEET C3.7C 8. STORM STRUCTURES SHALL BE INSTALLED PER STD PLAN 202.00/C3.3C 9. SEE LIFT STATION ELEVATIONS ON SHEET C3.9C KEY NOTES INSTALL LOCKING VANED GRATE PER STD PLAN 204.20/C3.4C 2� INSTALL 5 OLDCASTLE STORMCAPTURE UNITS AS SHOWN PER 342/C3.5C 3� INSTALL OLDCASTLE BIOPOD BIOFILTER VAULT PER 340/C3.5C R� ROOF DOWNSPOUT PER DETAIL 300/C3.3C 5� FIELD LOCATE AND CONNECT TO EXISTING STORMWATER SYSTEM INSTALL CONTECH INLINE CDS PER 341 /C3.5C RESTRICTOR TEE FOR SPILL CONTROL PER STD PLAN 237.00/C3.3C INSTALL SUMP PUMP PER DETAIL 320/C3.4C INSTALL CONTROL STRUCTURE PER STD PLAN 237.00/C3.3C 10 UNDERGROUND OVERHEAD UTILITIES PER ELECTRICAL 11 FIELD VERIFY ELEVATION AND LOCATION OF EXISTING WATER MAIN. IF CONFLICTS OCCUR BETWEEN THE EXISTING WATER MAIN AND THE PROPOSED STORM SYSTEM, NOTIFY THE ENGINEER C d w9 O of � �•�, V t 05 46449 4 SSf ONAL sitts&hill I CIVIL I STRUCTURAL I SURVEY 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-0153 http://www.sittshill.com/ Project No.: 19480 Project Mgr.: DCD Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM R-422942 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Wanders 05/08/2023 BROTHERTON CADILLAC - RENTON DATE: FIELDBOOK: PAGE: GRADING AND STORM DRAINAGE PLAN C3. 1 C (PUBLIC) SHEET: 16 OF: 9 N T O O N ,i1 N T O O N Q J 0 O N N A u