HomeMy WebLinkAboutR-422952A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
M rn
N N RIM=22.06
N N IE=16.44, 6"PVC E
I
IE=16.36, 6"PVC W
a "NO PARKING"
N
^I I 0
L.L Q
w "NO PARKING" 5 e
9D
►�
NO
8
)LE
IL=1/.y/, I CJ1-' W
12.36
FORCEMAIN E
16 �P i
mo
0
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12 "CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
to W
HALT
_W
NO
40-400000000000, P
7119 -23— _
"WATER LINE"
SD / RED "HAZARD"
-oa X2��
h r0
a �, O •
X �2.
NO PARKING r^
!'!'��
13
A7 A`_
TELEPHONE '
RISER
VHOI F
COMPOSITE UTILITIES PLAN (PRIVATE AND PUBLIC)
SCALE: 1"=20'
• Call 811
w • ® two business days
z before you dig NO.
U_
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE APPR APPROVED:
DCD
s�-
s
oNr- "NO PARKING"
CHAINLINK FENCE
X �k' STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTT. OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTT. OF STRUCT.=17.53
I
TPN 3340402755
AZULq PROPERTIES LLC
I I
I
)
I
VACATED R RENTON I I
5 8 PER CITY OF 4-68
�RDINANCE 0j150313
I REC.
NO 1997
29
LEGEND
PROPOSED FEATURES-
W
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
WATER METER
FIRE DEPARTMENT
CONNECTION
W
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C.
6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
B� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
5� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
%" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
C.
d
w9
O of
V
05 46449 4
D9sitts&hill
U
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
4;i9'4t2903 W-422901 R-422952
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ENJ:nders
PMENT ENGINEERING 05/08/2023
NORTH
HORIZONTAL SCALE: 1"=20' WASTEWATER UTILITY'
20 0 20 40 jstowell05/09/2023
SCALE: DATE:
VERTICAL: AD 1 1988
83/1 • BROTHERTON CADILLAC - RENTON
AS NOTED HORIZONTAL: NAD 1983/1991 CITY Y O F
FIELDBOOK:
RENTON PAGE:
ONE INCH DATU M • DRAWING NO:
AT FULL SCALE Planning/Building/Public Works Dept. COMPOSITE UTILITIES PLAN C4.00
IF NOT ONE INCH
SCALE ACCORDINGLY (PRIVATE AND PUBLIC)
SHEET: OF:
26 39
N
T
O
O
N
N
`i1
LO
N
T
O
O
N
Q
J
LO
O
O
N
N
A
u