Loading...
HomeMy WebLinkAboutR-422952A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON M rn N N RIM=22.06 N N IE=16.44, 6"PVC E I IE=16.36, 6"PVC W a "NO PARKING" N ^I I 0 L.L Q w "NO PARKING" 5 e 9D ►� NO 8 )LE IL=1/.y/, I CJ1-' W 12.36 FORCEMAIN E 16 �P i mo 0 STORM CATCH BASIN TYPE I RIM=23.66 IE=19.65, 12 "CPP N IE=19.76, 12 "CPP E IE=19.76, 12 "CPP S IE=20.38, 6"PVC W STORM CATCH BASINfi TYPE I RIM=22.55 IE=20.28, 6"PVC W IE=20.02, 12"CPP N i to W HALT _W NO 40-400000000000, P 7119 -23— _ "WATER LINE" SD / RED "HAZARD" -oa X2�� h r0 a �, O • X �2. NO PARKING r^ !'!'�� 13 A7 A`_ TELEPHONE ' RISER VHOI F COMPOSITE UTILITIES PLAN (PRIVATE AND PUBLIC) SCALE: 1"=20' • Call 811 w • ® two business days z before you dig NO. U_ REVISION SURVEYED: DESIGNED: DKM/RJJ DRAWN: KLK/DKM CHECKED: DCD BY DATE APPR APPROVED: DCD s�- s oNr- "NO PARKING" CHAINLINK FENCE X �k' STORM VAULT W/OIL WATER SEPARATOR 3 LIDS. UNABLE TO OPEN 2 OUTER LIDS RIM=24.08 TOP OF BAFFLE=21.78 TOP OF VERT. TEE=21.55, BOTT. OF VERT. TEE=18.58, 12"PVC W TOP OF PIPE=20.9f, 12"PVC E, UNABLE TO MEASURE IE WATER LEVEL=19.98 BOTT. OF STRUCT.=17.53 I TPN 3340402755 AZULq PROPERTIES LLC I I I ) I VACATED R RENTON I I 5 8 PER CITY OF 4-68 �RDINANCE 0j150313 I REC. NO 1997 29 LEGEND PROPOSED FEATURES- W DOMESTIC WATER SERVICE F FIRE SPRINKLER SERVICE WATER METER FIRE DEPARTMENT CONNECTION W FIRE HYDRANT SS SANITARY SEWER PIPE ® SANITARY SEWER MANHOLE WITH ACCESS LOCATION • SANITARY SEWER CLEANOUT N GATE VALVE ► THRUST BLOCK GENERAL NOTES 1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C. 2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C, RESPECTIVELY. 3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION. 4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION. 5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION FROM MAIN LINE TO PROPERTY LINE. 6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM PROPERTY LINE TO BUILDING CONNECTION. 7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION. 8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK INSTALLATION. 9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON FORCES. KEY NOTES 2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C. 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD. PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT. B� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN. 4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN. 5� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK. %" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C. 7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD. PLAN 340.8/C5.3C. SEE L2.00 FOR IRRIGATION PLAN OIL WATER SEPARATOR PER DETAIL 500/C5.2C 10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C 11 INSTALL RPBA PER STD PLAN 350.2/C5.4C 12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE THRUST BLOCK C. d w9 O of V 05 46449 4 D9sitts&hill U CIVIL I STRUCTURAL I SURVEY 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-0153 http://www.sittshill.com/ Project No.: 19480 Project Mgr.: DCD Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM 4;i9'4t2903 W-422901 R-422952 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ENJ:nders PMENT ENGINEERING 05/08/2023 NORTH HORIZONTAL SCALE: 1"=20' WASTEWATER UTILITY' 20 0 20 40 jstowell05/09/2023 SCALE: DATE: VERTICAL: AD 1 1988 83/1 • BROTHERTON CADILLAC - RENTON AS NOTED HORIZONTAL: NAD 1983/1991 CITY Y O F FIELDBOOK: RENTON PAGE: ONE INCH DATU M • DRAWING NO: AT FULL SCALE Planning/Building/Public Works Dept. COMPOSITE UTILITIES PLAN C4.00 IF NOT ONE INCH SCALE ACCORDINGLY (PRIVATE AND PUBLIC) SHEET: OF: 26 39 N T O O N N `i1 LO N T O O N Q J LO O O N N A u