Loading...
HomeMy WebLinkAboutS-422901A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON CV SANITARY SEWER MANHOLE X ti ti 3 RIM=21.33 O.W. PER CI 46 0 8 5 ss TYPE ll a TED NICE # ' , IE=18.38, 18"CPP NE CA R• AN a _.� - 11 ss �ti 16 (� °AS� °I Q I V RENTON ORDIN _ - SS X �� Q �� RIM=21.49 I a ° IE=18.37, 18 CPP S _ i Ss N IE=14.65, 8"PVC N I TE _ - sxu IE=14.75, 8"PVC E l W CONCRESS o0 N GIE=14.71 8"PVC S "of I /J Q -' SS xti8 12 8 TI SS GI a I Ss ��ti ASPHALT �j STORM DRAIN MANHOLE Q s ' r „ TYPE 1 ,Z 60 ° p Fr ss s y 4X4 RIM=21.28 211 �1. 1' S0 SS �ti>RO.g.W 4683 0 _ : cAs' - F� �'I� I 4I ' F., GRAVE`. �� ss INANCE # 0 4.. GAS- x _ �2 r p 3 . ;•.O/Yo IE=15.21, 12 DIE "STOP" - ' ss 1g6 NTUN ORD 7112p039 ' _ _ s, GAS.'° 61 22.5s I :.�',:.:' CO ` % IE=18.34, 18 DI S _ - w ss xti RE NO 199 A_. Ps ° CITYti p ;�3:•,. I.. " �4S ss - ASPHAL IN I ' REC. ' G _ cAs-a p oNP- PER g SD 13 9 i ti� R.0• "oNP" p I s ti _ A - p , 4oNP.-. ACATLD gR INANo _ Fo \� 22.93 X � X ti" w l �� o' . - g EN 7 I. X w '�� sD x 216$ x y,� R x - - ' o a s a Mu so 5ti ° .' . a p ' . CONCRETE `pso 94 5 ° p X ��1 -yam - - J I ;'' I .= WOOD `.` STAIRS I \ ° • • p �% Mu I I tit ° ONP ° ASPHALT o i X _ SD •' 'Fo a.. W II I ��P' . .. ° p v II � SD �0. ' 2�y+c W �.,. 10 p' P_ ' .�g� / po .o _ ° a !� _ �$ ..•: w , oN x� r p D ' a I: t EXIST G __aGAs_-�o N°o _ a pop: GRA��g, _ �95 I BUILDNG TT Y Y ' I \ L GAS a a' F BA( ti0�0 - IJ AVE _ _ 1Q �� I �' - - pa a Ti. STORM DRAIN MANHOLE o I ECON _ II I <10 ti ° TYPE II I STORM CATCH BASIN 5&12" CEDAR \ l GAS' �1� .p ONP' J p� RIM=22.92 I TYPE I III I ASPHALT _ 0' I I P \ go �' 6�l'� ,,`L�` IE=19.76, 8"PVC SE I RIM=22.49 I \ \N �1 " IE=17.10 15"CPP SW IE=20.34, 12 DI N STORM CATCH BASIN RETAINING BR THEPTON" ' I 14 CED WALLS "S�(t1 1 20 ti N 5 I 60 I IE=18.69, 12 "CONC E TYPE 1 m "EMPLOYEE OFp�a STORM DRAIN VAULT I IE=18.46, 15"CONC W I RIM=23.55 2?,�I WOOD YARD 0 PARKING ® x iFO 1 ti TYPE 11 IE=18.02 12"CPP S NI 6 Fz1 STAIRS- - t THE MONTH" �; DRAIN m / 0 g RIM=23.59 TOM DRAIN MANHOLE IE=17.97, 12"CPP W I I (CONCRETE I SD I 1 g5 IE=19.14 15 CPP NW SD 20' I m I I 116 /CISTAIRS TO DEAD END l o ° STORM CATCH BASIN I RIM=22.11 I o �. 2 6 MONUMENT POSITION 1 I E' � I I I TPN 3340402820 , / BA �T ;.:...�, 10 BAY STORM CATCH BASIN tit TYPE I A & D RENTON LLC IE=14.51, 4 PVC SE OF SURVEY TYPE I x \ o �5 / \ / I RIM=20.89 I BOTTOM STRUCTURE= 12.36 I DOOR 9404079012 I cC 113. \ ° . OR, NOT FOUND RIM=20.18 10 gg �1 o IE=19.23, 12"CPP SW 3 PVC, PUMP WITH FORCEMAIN E Q00 2396 rya I I LS `'..GRAVELt..� I IE=17.72, 18 CPP E I x�' 0 �• tip• m y N IE=17.46, 16"CPP S I � g9 o I I 16 eP I I Iv ^ 9 J 22 WA TEA TPN 33 �4?J2850 EXISTING I 23.70-- 3. EMPTY IE=17.35, 12 CMP W 6g I I 5 MAP 23." BROTHERTO �ADILLA Lu. �� g BUILDING STORM CATCH BASIN TEL TEL �j1 0 CONDUIT I•,� _)_ \�1 a ' TYPE I CIOI ti060 II I ti '� I o 10"I RIM=20.93 I aX NI 2g8 �' `': I 2X1&4X2 SD" L so �1 PIN IE=18.16, 18"CPP N I I a o 0 23.28 -- / 2 IE=18.33, 12"CPP E I X�p96 ti6 CO YARD DRAIN I �-� 8 5 I P IE=18.19, 18"CPP W I I I X o �0 1 ti� 23• TOP RIM=23 DEBRIS 15.92con .10 � I u- I 9 I 3 I m ASPHALT o t o �9 0 00 F.=24.04' - X ti�1 I I I Ifx 211 �11 1 I ASPHA T 1 I ' o O x I I' ti05 I I I 23 0 I z `l1� �x �' I � N 3 o 6 F.F.=23.88 I STORM CATCH BASIN I I I I 6 STAIRS \_ STORM CATCH BASIN ONCRETE 1 �5 0_ � � I ACCES: I g 6 5 � 6g m � � RIMTYPE23.66 I � �� � I ��2 BASEMI RIMTYPE20.48 I vN x 6 0 6 0 1® x15 ' IE=19.65, 12"CPP N o_ I a6 16 'y55 IE=19.76, 12 CPP E w I I I \ IE=19.30, 8"DI S � tio• �• ti 6 z I I I RE INI G 10 x I i X I\ I1 VACATED R•REN N ' IE=19.76, 12 CPP S I¢ N �1. I N ti 11 a PER CITY OF ' I I IE=20.38, 6"PVC W I I I i I I WA 1 313 SO I I II I 55 19970� SIDE SEWER SCOPE 1S I I I / o I I I I I YARD I N STORM CATCH BASIN( I I I ti 6 o UNDER PERMIT -24.00 I I I I DRAIN TYPE 1 ��� 0 - SS23002346 :- sD I li I I I BUILC 1 I 3 ^�� � \ 2 �� r' TPN 3340402885 RIM=21.65 Nix `� BROTHERTON CADILLA STORM CATCH BASIN I I I I I I IE=18.74,12 DI SE N I /a - - SS - 23LF-6" DIP @ 7.66% TYPE I ASPHALT I IE=18.54, 12"CPP NW I I /N ® B-SSCO04 6" CO \ 23LF-6" DIP @ 12.47% I RIM=22.55 IL I _ I ��• - I `�' \ N:174,127.70 I IE=20.28, 6"PVC W 'NO PARKIN E:1,297,167.31 \\I I� ° / B-SSC003, 6" CO I I IE=20.02, 12"CPP N 13 ❑9 I I I /� STORM CATCH BASIN I i 9� \ RIM:23.12 / N:174,127.12 RIM=20.62 I /� \ / IE:19.31 6" SE (IN)� E:1,297,190.30 I I I I i I 0� IE=19.03, 8"DI N ��16x� I a6 �6 $ Igo IE:19.31 6' E (IN) RIM:23.93 I I I II / IE=18.69, 12 DI SE x a I IE:19.31 6 N (OUT) IE:22.18 6 E (IN) IE=18.70, 12"DI NW I 7LF-6" DIP @ 7.66% IE:22.18 6" W (OUT) I I I II 6&2� II "� B-SSCO02, 6" CO STORM CATCH BASIN I 2� N:174,122.57 I I TYPE 1 I U � ;° ti E:1,297,172.18 RIM=23.25 1tik R 2LF-6" DIP @ 17.58% 1 I I'Y.'..:`::y.:'::..• IE=17.89, 12"CPP N 51x IIx2 AJ / RIM:23.29 \ I x� „ o IE:19.85 6" E (IN) / 2LF-6" DIP @ 15.81% IE=17.86, 12 CPP SW I 6g �' IE:19.85 6 NW (OUT) / ��:;. :. II NO PARKING . x \ B-SSCO01, 6" CO 3 '� Q �1a 9LF-6" DIP C 7.66% \ N:174,122.12 J o B-SS OWS, (PER MECHANICAL) eA \ E:1,297,190.18 z N:174,122.35 a1RIM:- / O[ T I o E:1,297,181.18 23.93 / ��� w w 5$ b op r� x21k3 �I RIM:23.61 \ IE:22.21 6" E (IN) 7 11 c, ,," 79 y6 X I I( I Q k IE: 20.79 6" E (IN) \ IE: 22.21 6" W (OUT) I N w w X I?- 6 I IE:20.54 6" W (OUT) ASPHALT Q w 1., I I\ oa�lgn3 �� \ 9LF-6" DIP @ 15.81% _ W I ��x \ _ , �. CONIC l _ g NI nN 16 • 11 O R _ _ W - ' W I � „NO �g6 ,��5• \ ti�� W P Xl V 5 _ w titi' - 23- X a 0 p P_ w01 __ 6 6' 1• I 8 ly' X � I O �cay „ X 1 23 � ' W /� �� SS �� l LEGEND PROPOSED FEATURES - SS SANITARY SEWER PIPE ® SANITARY SEWER MANHOLE WITH ACCESS LOCATION • SANITARY SEWER CLEANOUT GENERAL NOTES 1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.26. 2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) NOTES ON SHEETS C5.26. 3. SEE STD. PLAN 403.1/C5.2B FOR SANITARY SEWER CLEANOUT INSTALLATION. 4. SEE STD. PLAN 405/C5.2B FOR SANITARY SEWER PIPE INSTALLATION. 5. SEE STD. PLAN 406.1/C5.2B FOR SANITARY SEWER STUB INSTALLATION FROM MAIN LINE TO PROPERTY LINE. 6. SEE STD. PLAN 406.2/C5.2B FOR SANITARY SEWER INSTALLATION FROM PROPERTY LINE TO BUILDING CONNECTION. KEY NOTES OIL WATER SEPARATOR PER DETAIL 500/C5.2B :� CONFIRM INVERT ELEVATIONS OF EXISTING SANITARY CLEANOUT sitts&hill 6 MA E w g[I OF VP CIVIL I STRUCTURAL I SURVEY / A T 3 \ 5 y ��. 23 eP w X ��' i ss TELEPHONE q rJ+ 51 \ \ x 1� N ' ss RISER ' C 4815 CENTER STREET I TACOMA, WA. 98409 I / �ti• I x W ��g�j ' SS 40 N f 1 V PHONE: (253) 474-9449 I FAX: (253) 474-0153 W %< g1 N SANITARY SEWER MANHOLE ' ` http://www.sittshill.com/ SANITARY SEWER MANHOLE Q I 3 x w SS TYPE II - TYPE II � I I I , , _ 4' - x ' ss ' 66 .. RIM=23.23 _ •�y ♦6449 �of ,y? Project No.: 19480 Project Mgr.: DCD RIM=22.92 I cD , w 6 gs 2 15 MAPLE IE=17.07, 6„PVC E Or►1S[E �' `" '� rig IE=15.70, 8 PVC N �L6gx al X IE=15.85, 8"PVC E . 13TH ST. 5 S.W I AVE,)JW,L)� I STORM ' � Q CATCH BASIN TYPE 1 RIM=22.71 6/ IE=16.69, 18"CMP N x ti�5 it 414n hlr I -I L; i z so - `, 1P ..tip F• ��� tik IE=11.01, 6 PVC 3 oNAI £ Prot. Engineer: DKM/RJJ Prot. Drafter: KLK/DKM g �61 W o �xti� iss GRPV��✓PLE��15" MAPLE "24 'IE=17.19, 8"PVC W __ p SS PARKING"- - 0 v Ss 1 1 "NO SS ss g S-422901 s s titi56 x 22� , :,TF � OEPARKING" �ACA CITY ITYROF RENTON s x --2 PER CIT CE #4610 4 IN COMPLIANCE WITH CITY OF RENTON STANDARDS �� 5g ' ��' ORDIN N� 1996p614028 1g xti20`���i _ ' REC. DEVELOPMENT ENGINEERING \ �o Wanders 05/08/2023 220 x� STORM CATCH BASIN NORTH x I TYPE I (PRIVATE) HORIZONTAL SCALE: 1"=20' rWA$TEWATER UTILITY GRADING AND STORM DRAINAGE PLAN ` � 20 0 20 40 SCALE: 1 "=20' • Call 811 • m two business days before you dig NO. REVISION SURVEYED: DESIGNED: DKM/RJJ DRAWN: KLK/DKM CHECKED: DCD BY DATE AP P R APPROVED: DCD jstowell 05/09/2023 SCALE: DATE: VERTICAL: NAND 1988• BROTHERTON BUICK-GMC - RENTON AS NOTED HORIZONTAL: NAD 1983/13/1991 C T Y OF FIELDBOOK: RENTON PAGE: ° ONE INCH DATUM DRAWING NO:C5.013 �� • O ^ AT FULL SCALE Plan ning/Building/Public Works Dept. WASTEWATER UTILITIES CONSTRUCTION PLAN (C,/ I13 IF NOT ONE INCH SCALE ACCORDINGLY (PRIVATE) SHEET: OF: 21 29 N T O O N 'i1 N T O O N Q J LO O O N CV A u