Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MFP23003163.pdf
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23003163 IVR Number: 23003163 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:06/14/2023Application Date:3343301150Parcel Number: 1700 NE 44TH ST Permit Type:07/03/2023Issue Date:Franchise Permit Work Class:07/02/2024Expiration Date:Minor Utility Job Number: 109139002Franchise Type:Natural Gas Description: PSE Gas CREW TO RETIRE EXISTING 2" PE MAIN AND INSTALL NEW 2" MPE IP MAIN. APPROX 108' IN ROW. POTHOLE ALL EXISTING UTILITIES. RSTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX INFRASOURCE SVCS B: (206) 949-5846Contractor Business License Number: 36742Construction Contractor: INFRASL871C2 Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering INFRASOURCE, INC 6905 S 228TH ST KENT, WA 98032 PLEASE SEE ATTACHED 109139002 1700 NE 44TH ST BRIAN PARKER 253-243-4165 MFP23003163 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 7/3/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG NE 44TH STI-4 0 5 O N R A M P I-4 0 5 O F F R A M P LAKE WASHINGTONBLVD NE1910LEFTKEEPR4-8BS/WCLOSEDR9-9W20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5R200'200'1 MILEBEFOREWORK AREAPCMSW20-1RO A D W O R K AH E A D ©© 11 11 11 11 11 11111211142" MAINPATHCUT &CAPPLACE PCMS BOARDS 1 MILEBEFORE WORK AREA.TWO-SECOND SEQUENCE2-LINE, 8 CHARACTERMESSAGES WILL READ:1)2)ROADWORKAHEADEXPECTEDDELAY SRMP7.50'90'45'NProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVKali-Jamal Collins424-425-6425Kali-jamal.collins@pse.com1 OF 41700 NE 44th St, Renton, WA0 1178223205/25/2023Notes:1. Notify WSDOT at least 5 days prior to scheduled date.2. At time of work, call wsdot radio (per region as instructed inpermit) at the time the lane is closed (or intersection flagged); andagain when the lane/intersection is opened. leave a contact nameand cell phone number with radio.3. All advanced warning signs and spacing to conform to theMUTCD and WSDOT standards.4. Channelizing devices shall be traffic drums (barrels) withsteady burning Type C lights on all State Routes and Hwys.5. All signs are 48" x 48", Black legend on Orange background.Use class B signs unless otherwise specified.6. Flaggers shall be in radio contact with each other at alltimes; flagger stations shall be illuminated during hours ofdarkness with minimum 150w lights7. All lane closures shall not infringe upon adjacent lanes.8. Alert affected residents and businesses if existing onWSDOT roadways. All sidewalks, driveways, exits andegresses shall be completely clear unless otherwiseindicated.9. Work areas will be noted as per distances between StateRoute milepost markers.10. See sheet 4 for WSDOT Notes and Tables.TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jamal I. CollinsCard No. 013375Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425VICINITY MAPSRMP 7.50WORK PITLEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYTRENCHMFP23003163 NE 44TH STARRW-BRD ARRW-BRD W20-1ROADWORKAHEAD CENTER LANECLOSEDAHEADW9-3 W20-5L200'200'200'I-4 0 5 O N R A M P I-4 0 5 O F F R A M P LAKE WASHINGTONBLVD NE1910W20-1ROADWORKAHEAD W20-1ROADWORKAHEAD1 MILEBEFOREWORK AREAPCMS1111©©121114121212X'W1-4RW20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5LW20-5L200'200'200'2" MAIN PATHPLACE PCMS BOARDS 1 MILEBEFORE WORK AREA.TWO-SECOND SEQUENCE2-LINE, 8 CHARACTERMESSAGES WILL READ:1)2)ROADWORKAHEADEXPECTEDDELAY SRMP7.5Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVKali-Jamal Collins424-425-6425Kali-jamal.collins@pse.com2 OF 41700 NE 44th St, Renton, WA0 1178223205/25/20230'90'45'NNotes:1. Notify WSDOT at least 5 days prior to scheduled date.2. At time of work, call wsdot radio (per region as instructed inpermit) at the time the lane is closed (or intersection flagged); andagain when the lane/intersection is opened. leave a contact nameand cell phone number with radio.3. All advanced warning signs and spacing to conform to theMUTCD and WSDOT standards.4. Channelizing devices shall be traffic drums (barrels) withsteady burning Type C lights on all State Routes and Hwys.5. All signs are 48" x 48", Black legend on Orange background.Use class B signs unless otherwise specified.6. Flaggers shall be in radio contact with each other at alltimes; flagger stations shall be illuminated during hours ofdarkness with minimum 150w lights7. All lane closures shall not infringe upon adjacent lanes.8. Alert affected residents and businesses if existing onWSDOT roadways. All sidewalks, driveways, exits andegresses shall be completely clear unless otherwiseindicated.9. Work areas will be noted as per distances between StateRoute milepost markers.10. See sheet 4 for WSDOT Notes and Tables.TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jamal I. CollinsCard No. 013375Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425VICINITY MAPSRMP 7.50WORK PIT28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYTRENCHMFP23003163 NE 44TH STARRW-BRD W20-1ROADWORKAHEAD RIGHT LANECLOSEDAHEADW20-5R W20-5R200'200'200'I-4 0 5 O N R A M P I-4 0 5 O F F R A M P LAKE WASHINGTONBLVD NE1910W20-1ROADWORKAHEAD W20-1ROADWORKAHEAD1 MILEBEFOREWORK AREAPCMS1111©©121114121212W20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5LW20-5L200'200'200'S/WCLOSED R9-9S/WCLOSEDR9-92" MAIN PATHPLACE PCMS BOARDS 1 MILEBEFORE WORK AREA.TWO-SECOND SEQUENCE2-LINE, 8 CHARACTERMESSAGES WILL READ:1)2)ROADWORKAHEADEXPECTEDDELAY SRMP7.5Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVKali-Jamal Collins424-425-6425Kali-jamal.collins@pse.com3 OF 41700 NE 44th St, Renton, WA0 1178223205/25/20230'90'45'NNotes:1. Notify WSDOT at least 5 days prior to scheduled date.2. At time of work, call wsdot radio (per region as instructed inpermit) at the time the lane is closed (or intersection flagged); andagain when the lane/intersection is opened. leave a contact nameand cell phone number with radio.3. All advanced warning signs and spacing to conform to theMUTCD and WSDOT standards.4. Channelizing devices shall be traffic drums (barrels) withsteady burning Type C lights on all State Routes and Hwys.5. All signs are 48" x 48", Black legend on Orange background.Use class B signs unless otherwise specified.6. Flaggers shall be in radio contact with each other at alltimes; flagger stations shall be illuminated during hours ofdarkness with minimum 150w lights7. All lane closures shall not infringe upon adjacent lanes.8. Alert affected residents and businesses if existing onWSDOT roadways. All sidewalks, driveways, exits andegresses shall be completely clear unless otherwiseindicated.9. Work areas will be noted as per distances between StateRoute milepost markers.10. See sheet 4 for WSDOT Notes and Tables.TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jamal I. CollinsCard No. 013375Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425VICINITY MAPSRMP 7.50WORK PIT28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYTRENCHMFP23003163 Arterial streets, travel lanes and sidewalks shall remain open during peak traffic hours: 6a.m. to 7p.m., MONDAY - FRIDAY (Unless otherwise indicated by SDOT) SDOT District inspections notification required. Must comply with all SDCI Noise/variance requirements for impacts during hours indicated. SDCI Noise Control: 206-615-1190 (*) REQUIREMENTS *Signs, Devices and spacing shall conform to the Seattle TCM/MUTCD. Signs shall not be placed in a way that will partially or totally block active travel lanes, bike lanes or sidewalks. *Notify SDOT TCO when setting up and when removing arterial travel lane impacts - 206-684-5117. *Priority access shall be provided to emergency vehicles. *Coordinate/facilitate driveway/load zone access. (10 days in advance). *Maintain 11'vehicle travel lane widths. *Maintain 4' sidewalk widths (8' in the down town core) unless otherwise approved via this TCP. Sidewalks are either open or not open. A sidewalk is closed when a minimum of 4' cannot be maintained. Pedestrians shall not be routed within 2' of the curb face/vehicle lane edge. *Refer to the Seattle Manual for Street Work page 47 section: VI and SDOT Directors Rule 10-2015 for Pedestrian requirements. For more information visit : http://www.seattle.gov/transportation/document-library/ directors-rules-and -ordinances. *Reserve curb space including paid parking w/ SDOT traffic permits @ (206) 684-5086. *notify Metro of bus route/stop impacts (Metro trolley coaches shall not shift more than 9' off center of lines): Trolley 206-477-1150/ Non Trolley 206-477-1140. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 Warning SignSpacing in Feet Taper Length (L) in feet Channelization Device Spacing in Feet (maximum) Classof RoadA B C LaneWidth 10'12' Vehicle Barricades& Drums other**Warning Sign Min.Size in inches I II III *75 90 SpeedLimit SpeedLimit x 2 12'Taper (2)TangentTaper (S)Tangent 15 30 30x30 SpeedLimit SpeedLimit x 2 SpeedLimit SpeedLimit x 2 20 50 30x30 30 80 48x48 150 150 150 20075 350 350 350 450 540 Road Class Definitions Class I - Central Business District, University District Class II - Arterial Streets Class III - All partially or full controlled access arterial streets *Advance warning sign spacing depends on availability of curb space*Vertical barricades cones tubular guideposts SDOT HUB coordination required (10 days Prior) *Schedule to be determined by the SDOT HUB coordinator. SDOT ConstructionHub@seattle.gov. CONSTRUCTION HUB TEMPORARY TRAFFIC CONTROL PLAN SEATTLE TABLES Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Kali-Jamal Collins 424-425-6425 Kali-jamal.collins@pse.com 4 OF 41700 NE 44th St, Renton, WA 0 11782232 05/25/2023 Puget Sound Energy Traffic Control Supervisor: Jamal I. Collins Card No. 013375 Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425 MFP23003163 NE 44TH S T I / C PAN ABO DE CEDAR HOME S SEATTLE S E AH A W K S HEADQUA R T E RS PUBLIC STORAGESB I-4 0 5 O N R A M P SB I-405 O F F R A M P NB I-40 5 O F F RA M P N 38TH STN 40TH STLAKE WASH I N G T O N B L VD N LAKE WAS H INGTO N B LVD SE RIPLEY L N N LAKE W A SH I N G TO N B LV D N LAKE WA S H I NG T O N BL V D N E JONES AVE NEMEADOW AVE NNE 44TH ST SE 76TH ST NE 44TH ST NE 43RD PL SEAHAW KS W A Y EASTSIDE RAIL CORRID O R EASTSIDE R A I L C O R R I D O R MAY CR E EKMAY CREEK N 37TH STJONES AVE NELINCO L N A V E N E SEAHAW K S WA Y SEAHAW KS W A Y LAKE WASHINGTON BLV D N E LAKE W A S H I N G T O N B LV D N E LAKE WA S H I N G TON LOO P T R A IL SB I-4 0 5 NB I-4 0 5 N 36TH ST N 38TH STN 40TH ST RIPLEY LN N LAKE W A SHI N G T ON B L V D N E JONES A V E N E MEADOW A V E N NE 43RD PLSEAHAWK S W A Y N 37TH ST JONE S A V E N E LINCOLN AVE NENE 44TH ST 4350 Lake Washington blvd NE 44TH ST SEAHAWKS WAY EASTSIDE R A I L C O R RID O R PUBLIC S T O R A G E 1755 N E 4 8 T H S T DENNY'S RESTAURANT 4750 LAKE WASHINGTON BLVD NE BARONE GARDEN4800 LAKE WASHINGTON BLVD NE 334330-1125 PARCEL NUMBER 334330-1120 PARCEL NUMBER 334330-1140 PARCEL NUMBER 334330-1150 PARCEL NUMBER 334330-1142 PARCEL NUMBER 334330-1143 PARCEL NUMBER 334330-1145 PARCEL NUMBER 334330-1141 PARCEL NUMBER SYSTEM MAOP DENOTED BY: SYSTEM MAOP = ___ PSIG BOX (TEST LEAD) INSTALLATION. THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. PURGE POINTS AND PRESSURE TAPS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3300, AND 2525.1200. ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO STANDARD GAS CONSTRUCTION NOTES: 14. 13. 15. 10. 11. THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 9. 6. 7. 5. 4. 3. 1. 45 16. IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ----------------- NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS).2. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED.12. ___________________________, PHONE______________. NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES17. FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD) PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PROJECT MANAGER TO MAKE EGOR RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300, 2525.3400 REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARDS 2525.2100 FOR INSERTIONS AND 2525.3600 FOR STANDARDS 2525.2100 AND 2525.3600. PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 11. 12. 14. 13. AND 2525.1200, AND PSE GAS FIELD PROCEDURE 4700.1500. PER PSE GAS OPERATING STANDARD 2550.1600. ABANDONMENT OR DEACTIVATION. 10. 9. 5. 6. 7. 8. GAS OPERATING STANDARD 2525.2300. 4. 1. 2. 3. OUTAGE. STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY:##### 16.ACTIVE SERVICES TO BE PARTIALLY REPLACED AND TEST & TIED DENOTED BY: 17.ACTIVE SERVICES TO BE TESTED & TIED DENOTED BY: ##### ##### PLOT PLAN I-405N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS PROJECT PHASE Notification #Order # SVC Retirement Relocate SAP Superior Service/Meter Service/Meter HP Svc/MSA Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter WORK AREA STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 60 IP469 - 45 INSTALL MPE N/AMN Retirement N/A N/A 11782232 109139002 108631330 RETIRMENT PE N/A N/A N/A N/A N/A N/A N/A SAP BATCH YEAR & FOOTAGE ACTUAL LENGTH OF RETIREMENT MATERIAL RETIRED ORIGINAL JOB ORIGINAL YEAR PROPOSED LENGTH OF RETIREMENT SIZE OF RETIRED MAINPLOT PLAN ASEE SHEET 2Owner / Developer Contact Info officeATTN: WSDOT I-405 Program Randy Norberg 425-456-8578 109139002NE 44TH ST RW - 126252 1"=30'1 / 3 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr CITY OF RENTON CSPSKGPI 200.080 201.083 469E SE-29-24-5 ENGR - POWER 2" MPE IP MAIN RELOCATION NE 44TH ST 1800 NE 44TH ST, RENTON 98056 109139002 Cell Phone: Project Manager Contact Information: E-Mail: Name: 253-243-4165 Brain.Parker@pse.com BRIAN PARKER Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 COORDINATE INSTALLATION WITH CORROSION CONTROL 1/24/2020: PER W.JOHNS, APPROVED JOB AS DESIGNED TYPICAL GAS MAIN LINE TRENCH DETAIL RESIDENTIAL Excavated Dirt Pile 24" Min NOTE: Install 12" shading if the backfill contains rocks greater than 6" dia. 36" Min Cover Gas Service Line SIDE ACCESS VEHICLE Final Grade 4" Sand Bedding 12" Min. of Acceptable Backfill (See Definition Above) 6" Sand Shading 12"-18" Min Backfill for Direct Bury - The final backfill may be soil-based select material or native soil, but free of construction debris and shall not contain rocks larger than 10"-in. diameter to prevent impedence of gas system maintenance. Not to scale BRIAN PARKER 253-243-4165 KEVIN CAPRIO 508-742-8891 NASH KIRIKA 425-306-1755 05/24/23 05/24/23 05/24/23 D. DAO 425-424-6426 05/24/23 MFP23003163 STORMWATERTREATMENTAREA WALL 07.46RWALL 07.45R WALL 07.48RWALL 07.49R 25NE 44TH STNE 44TH STLAKE WASHINGTON BLVD NE JONES AVE NE LINCOLN AVE NERENTON R/W334330-1150PARCEL NUMBER334330-1140PARCEL NUMBER"1800""1700"WSDOT R/W LIMITED ACCESS 1091390021-1/8" MPEI2015-EDEACTIVATE IN PLACEEXISTING 2" MPE IP MAIN2" PE IP WANDERS W-EDGE S/W923553IP GAS FLOW1323PROPOSED PIPE 2" MPE IP MAIN27' E OF PL___' E OF PL1-1/4" MPE IP (____')END OF MAIN195' E1-1/4" PE2001SITE PLANSCALE: 1" = 30'IP GAS FLOWEXISTING EOPFUTURE EOPEASEMENT REQUIRED (____') 2" PE IP 1' W OF E. PL 883244 1"=30'2 / 3N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ADESIGNED BY PUGET SOUND ENERGYUTILITIESCONTACTPHONE#COUNTY1/4 SECOP MAPEmer SectGAS WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYCP APPROVALMAPPINGSCALEPAGEENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEDrawing NumberSAP Sup Order NbrCSPSKGPIENGR - POWERKINGCITY OF RENTON200.080201.083469ESE-29-24-5109139002NE 44TH ST1800 NE 44TH ST, RENTON 98056Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500Reviewed and complied with all construction notes.Recorded all required information on the as-built per GOS 2500.1700.Completed post installation inspection per GOS 2525.1200 and 2525.2700.Left the work area in a clean and safe condition.FITTER'S CHECKLISTForeman's Name (printed) ___________________________________ Foreman's Signature________________________________________Company: InfraSource Construction Date ______________(CHECK BOX TO CONFIRM COMPLETION)4680 06/11RW - 12625215' E AWAYFROM THRUST BLOCKS2" MPE IP MAIN RELOCATIONBRIAN PARKER253-243-4165KEVIN CAPRIO508-742-8891NASH KIRIKA425-306-175505/24/2305/24/2305/24/233' X 5' CUTD. DAO425-424-642605/24/23MFP23003163POTHOLE ALL EXISTING UTILITIESRESTORATION PER CITY OF RENTON STANDARDS 109139002Scale: NTSTIE IN DETAIL13Scale: NTSTIE IN DETAIL232"x90° ELBOW MPE112 'N C/L & 27'E OF PL ____'N C/L & ____'' E OF W. PL(____')SQUEEZE & TIE IN2"x90° ELBOW MPE112'N C/L & 1'W OF E. PL____'N C/L & ____'W OF E. PL2" MPE IP 1'E W. PL883244IP GAS FLOW 2" PE IP WANDERS W-EDGE S/W923553CUT & CAPCAP 2" MPE20'S C/L & 1'W OF E. PL___'S C/L & ___'W OF E PL59' S40' S198' EDEACTIVATE IN PLACEEXISTING 2" PE IP MAINIP GAS FLOW1-1/4" MPE IP PROPOSED PIPE 2" MPE IP MAIN27' E OF PL ___' E OF PLPROPOSED PIPE 2" MPE IP MAIN27' E OF PL ___' E OF W. PL2" MPE IP 1'W OF E. PL 883244END OF MAIN195' ETIE INTEE HV 2"X2" MPE37'S C/L & 27 'E OF W. PL____'S C/L & ____'E OF W. PL38' SDEACTIVATE IN PLACEEXISTING 2" PE IP MAIN1"=30'3 / 3N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ADESIGNED BY PUGET SOUND ENERGYUTILITIESCONTACTPHONE#COUNTY1/4 SECOP MAPEmer SectGAS WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYCP APPROVALMAPPINGSCALEPAGEENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEDrawing NumberSAP Sup Order NbrCSPSKGPIENGR - POWERKINGCITY OF RENTON200.080201.083BRIAN PARKER253-243-4165469ESE-29-24-5KEVIN CAPRIO508-742-8891NASH KIRIKA425-306-1755109139002NE 44TH ST1800 NE 44TH ST, RENTON 98056Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500Reviewed and complied with all construction notes.Recorded all required information on the as-built per GOS 2500.1700.Completed post installation inspection per GOS 2525.1200 and 2525.2700.Left the work area in a clean and safe condition.FITTER'S CHECKLISTForeman's Name (printed) ___________________________________ Foreman's Signature________________________________________Company: InfraSource Construction Date ______________(CHECK BOX TO CONFIRM COMPLETION)4680 06/11227' E 1800 NE 44TH ST, RENTON 98056RW - 126252PROPOSED PIPE 2" MPE IP MAINTO MAINTAIN A MINIMUM OF3' DEPTH BELOW NEW GRADE(NEW GRADE WOULD BE2' BELOW EXISTING GAS)PROPOSED PIPE 2" MPE IP MAINTO MAINTAIN A MINIMUM OF3' DEPTH BELOW NEW GRADE(NEW GRADE WOULD BE2' BELOW EXISTING GAS)2" MPE IP MAIN RELOCATION05/24/2305/24/2305/24/23D. DAO425-424-642605/24/23MFP23003163