Loading...
HomeMy WebLinkAboutMFP23003514.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23003514 IVR Number: 23003514 Permit Information Permit Name: Century Link Permits Address/Location:07/05/2023Application Date:0723059007Parcel Number: 616 W PERIMETER RD Permit Type:07/06/2023Issue Date:Franchise Permit Work Class:07/05/2024Expiration Date:Minor Utility Job Number: P.057905Franchise Type:Telephone Description: Lumen to remove existing 3048 HH and replace with new 264 TA HH, install new conduit from new HH to pole A1366495, open trench approx. 120' from new 264 TA HH to pole A1366494, place new riser up pole and splice, and remove existing aerial between poles. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Prime Electric Inc 3460 161ST Ave SE Bellevue, WA 98008 Applicant Stephen Neumann Fibe Solutions 604 W Meeker St., Suite 103 KENT, WA 98032 C: (425) 753-1916Applicant Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Tawnya Longfellow 22517 88th ave S Kent/WA 98031 Project Name: P.057905 Permit #: Site Address: 616 W Perimeter Road Work Date: From _____________ To _____________ Work Time: Start ______________ End______________ Construction Company: Northsky Communications Lumen to remove existing 3048 HH and replace with new 264-TA HH, install new conduit from new HH to pole A1366495, open trench approx. 120' from new 264-TA HH to pole A1366494, place new riser up pole and splice, and remove existing aerial between poles. 08/05/2023 11/05/2023 Scott Warlick CED 7/6/2023 MFP23003514 Monday - Friday 8:00AM - 3:00PM Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 7/5/2023 MFP23003514 MFP23003514 MFP23003514 MFP23003514 1 2 3 4 5 6 7 RAINIER AVE S TPN: 0723059007 616 W PERIMETER RD WEST PERIMETER ROAD CONCRETE REMOVAL STABILIZED CONSTRUCTION ENTRANCE STRAW WATTLES ASPHALT REMOVAL SILT FENCE AND HIGH VISIBILITY FENCE SILT AND HIGH-VISIBLITY FENCE POINT TABLE POINT NO. 1 2 3 4 5 6 7 NORTHING 182303.62 182294.71 182321.64 182364.44 182401.30 182477.75 182483.25 EASTING 1298174.71 1298129.62 1298124.43 1298131.75 1298123.70 1298113.14 1298139.01 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:EXISTING SITE, TESC, ANDDEMOLITION PLANCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECTCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECT001/20/23 ISSUED FOR BIDDINGLJB RJF EXISTING SITE, TESC, AND DEMOLITION PLAN EXISTING WEST HILL BOOSTER PUMP STATION OUTLINE OF PROPOSED CONCRETE PAD AND EG SHELTER PRV STATION 52 - WH495 ZONE TO KD 320 ZONE PRV STATION 54 - KD320 ZONE TO VLY196 ZONE VLY 196ZONE WH 495ZONE KD 320ZONE KD 320ZONE WH 495ZONE VLY 196ZONE LJBRJFJan 20, 2023Jan 20, 2023REN21-0234WHBPS-D-C01.DWGSHOWN C01 3 32 1 1 ABANDONED SANITARY SEWER FORCE MAIN RECOMMENDED TESC SEQUENCE 1. CLEARING AND GRADING LIMITS FLAGGING WITH HIGH VISIBILITY FENCING. 2. INSTALL SILT FENCE PER COR STD PLAN 214.0 3. INSTALL CATCH BASIN INSERT AS DIRECTED BY THE ENGINEER PER COR STD PLAN 216.3 4. GRADE AND INSTALL STABILIZED CONSTRUCTION ENTRANCE PER COR STD PLAN 215.10 AND DWG NO. C02. 5. INSTALL STRAW WADDLE PER COR STD PLAN 213.40 6. PRIOR TO VERTICAL CUT, INSTALL BLANKETS AND NETS PER COR STD PLAN 213.20 7. MAINTAIN EROSION CONTROL MEASURES, RELOCATE EROSION CONTROL MEASURES, OR INSTALL NEW MEASURES AS SITE CONDITIONS CHANGE OR AS DIRECTED BY THE ENGINEER SO THAT THE EROSION AND SEDIMENT CONTROL AND POLLUTION PREVENTION ARE ALWAYS IN ACCORDANCE WITH THE CITY'S STANDARDS AND REQUIREMENTS. 8. COVER ALL AREAS THAT WILL BE UNWORKED MORE THAN 7 DAYS DURING DRY SEASON OR 2 DAYS DURING WET SEASON WITH STRAW, WOOD FIBER, MULCH, COMPOST, OR EQUIVALENT. 9. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. 10. SEED ANY AREAS THAT REMAIN UNWORKED FOR MORE THAN 30 DAYS. 11. WEST PERIMETER ROAD AND EXISTING DRIVEWAY MUST BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE ENGINEER. 12. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED. ONCE STABILIZED, ALL BEST MANAGEMENT PRACTICES MUST BE REMOVED. DEMO AND TESC LEGEND 2 2INSTALL SILT FENCE AND HIGH VISIBILITY FENCE INSTALL EROSION CONTROL BLANKETS OR NETS OVERHEAD COMMUNICATION LINE TO BE RELOCATED UNDERGROUND, SEE DWG NO. E03 FOR MORE INFORMATION REMOVE CONCRETE CURB REMOVE ASPHALT PER COR STD PLAN 103 CONSTRUCTION NOTES REMOVE CONCRETE DRIVEWAY TO NEAREST WHOLE PANEL PROTECT EXISTING COMMUNICATION JUNCTION BOX PROTECT OR AUGMENT THE EXISTING FACILITY FENCING AND GATE POSTS AS NECESSARY FOR CONSTRUCTION ACTIVITIES AND DAILY SECURITY. REMOVE CONCRETE WALL AS NECESSARY TO CONSTRUCT IMPROVEMENTS, SEE PHOTO 2 EXISTING TRANSFORMER PAD TO REMAIN. EXISTING TRANSFORMER TO BE REMOVED AND REPLACED WITH NEW TRANSFORMER INSTALLED BY PSE, SEE ELECTRICAL SITE PLAN ON DWG NO. E03 FOR MORE INFORMATION. SECURE EXCAVATION/TRENCHES NIGHTLY IF NOT WITHIN CONSTRUCTION FENCING INSTALL STRAW WADDLES ALONG WEST SIDE OF CONSTRUCTION ENTRANCE STABILIZED CONSTRUCTION ENTRANCE PER COR STD PLAN 215.10 BEGIN CONCRETE CURB AND GUTTER REMOVAL APPROX. LOCATION: N: 182306.29 E: 1298174.18 END CONCRETE CURB AND GUTTER REMOVAL APPROX. LOCATION: N: 182398.85 E: 1298156.32 END CONCRETE REMOVAL AT PANEL EDGE REMOVE CONCRETE CURB AND GUTTER PER COR STD PLAN 103 EXISTING TREE TO BE REMOVED OUTLINE OF PROPOSED EG APPROX. CONCRETE PAD AND EG SHELTER EXTENTS DO NOT DISTURB EXISTING LANDMARK TREE. PROVIDE ANY/ALL PROTECTIVE MEASURES NECESSARY TO AVOID ANY DISTURBANCE TO TREE. ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE EVALUATED BY A CERTIFIED ARBORIST AND ANY SUBSEQUENT MITIGATION MEASURES RECOMMENDED SHALL BE AT THE SOLE EXPENSE OF THE CONTRACTOR. PROTECT EXISTING TREE3.56Extend new conduit to pole # 204 (A1366494) Build new riser at pole Splice new to existing Open trench (2) 4" Schd 40 PVC @ 4.5' minimum depth Approx. 118ft Place new ANMW-200 in new conduit Maintain min 4ft separation from storm Remove aerial cable after cut over Remove existing 3048 HH & Replace with new 264-TA Install additional (1) 4" PVC from vault to pole PROJECT MANAGER: FRED ASTON Fred.A.Aston@Lumen.com (863) 258-3261 Mobile This work appears to be on private property and may require additional approval from the property owner. MFP23003514 RAINIER AVE S TPN: 0723059007 616 W PERIMETER RD WEST PERIMETER ROAD 000 700 BP: 0+00.00 N: 182319.33 E: 1298103.85 EP: 0+70.00 N: 182333.10 E: 1298172.48 40 45 3941424344 282726251:2.51:11:1 1:1 2:1CONSTRUCTION SITE SECTION 10' 20' 30' 40' 50' 60' 10' 20' 30' 40' 50' 60' 0+00 0+70 LJBRJFJan 20, 2023Jan 20, 2023REN21-0234WHBPS-D-C02.DWGSHOWN C02 4 32 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:CONSTRUCTION GRADING PLANAND SECTIONCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECTCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECT001/20/23 ISSUED FOR BIDDINGLJB RJF CONSTRUCTION GRADING SITE PLAN CAST IN-PLACE CONCRETE RETAINING WALL, SEE DWG NO. S01 FOR ADDITIONAL INFORMATION EXISTING CONCRETE OUTLINE OF ROOF OVERHANG APPROXIMATE CONSTRUCTION GRADE EXISTING GRADE PROPOSED GENERATOR STRUCTURE PROPOSED GENERATOR EXISTING WEST HILL BOOSTER PUMP STATION CONSTRUCTION GRADING NOTES STABILIZED CONSTRUCTION ENTRANCE SEE ENGINEERING GEOLOGY EVALUATION MEMO WITHIN PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION REGARDING INVESTIGATIONS, FINDINGS, AND RECOMMENDATIONS. SLOPES AND SHORING ·EXCAVATIONS INTO NATIVE SOILS ARE LIKELY TO TEMPORARILY HOLD VERTICAL SLOPES. ·IF LOOSE, UNCOMPACTED FILL SOIL IS ENCOUNTERED IN THE RETAINING WALL EXCAVATION, SHORING MAY BE REQUIRED TO SUPPORT PORTIONS OF THE EXCAVATION TO PROTECT WORKERS AND TO SUPPORT SLOPES. ·ALL EXCAVATIONS SHOULD COMPLY WITH ALL OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION SAFETY REQUIREMENTS. ·ALL EXCAVATED SLOPES SHOULD BE REVIEWED PERIODICALLY FOR STABILITY, INCLUDING REVIEW OF THE TOP OF THE SLOPE FOR TENSION CRACKS, AND THE SIDEWALLS AND FLOORS FOR EVIDENCE OF SEEPAGE OR SATURATED SOIL CONDITIONS. ·THE NATIVE SOIL IS MODERATELY ERODIBLE. ALL TEMPORARY SLOPES IN NATIVE MATERIAL SHOULD BE PROTECTED FROM EROSION DURING PRECIPITATION EVENTS BY PLASTIC SHEETING OR OTHER TECHNIQUES THAT PREVENT RAIN SPLASH EROSION AND RILLING. ·THE MAXIMUM TEMPORARY SLOPE IN THE NATIVE SOIL MAY BE CUT CLOSE TO VERTICAL, AND THE PERMANENT SLOPE CONSTRUCTED IN THE NATIVE SOIL SHOULD BE NO STEEPER THAN 1H:1V. ·DURING PROJECT CONSTRUCTION, THE CITY WILL HIRE A LICENSED ENGINEERING GEOLOGIST (LEG) OR PROFESSIONAL ENGINEER WITH GEOTECHNICAL EXPERIENCE (PEG) TO INSPECT THE EXCAVATIONS TO CONFIRM WHETHER THE EARTH EXPOSED DURING EXCAVATION IS CONSISTENT WITH THE PROJECT TECHNICAL MEMORANDUM AND FAVORABLE FOR PROCEEDING WITH THE PROJECT AS PLANNED. ·DRY SEASON CONSTRUCTION IS RECOMMENDED PER THE ENGINEERING GEOLOGY EVALUATION MEMO. EXISTING BOX CULVERT/STORM DRAINAGE SYSTEM, DO NOT DISTURB. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND IMPLEMENT A UTILITY PROTECTION PLAN TO ENSURE NO DAMAGE IS SUSTAINED. STRAW WADDLES TOE OF EXCAVATION: 25.00'3.5 ftExtend new conduit to pole # 204 (A1366494) Build new riser at pole Splice new to existing Open trench (2) 4" Schd 40 PVC @ 4.5' minimum depth Approx. 118ft Place new ANMW-200 in new conduit Maintain min 4ft separation from storm Remove aerial cable after cut over Remove existing 3048 HH & Replace with new 264-TA Install additional (1) 4" PVC from vault to pole 13.9 ftMFP23003514 RAINIER AVE S WEST PERIMETER ROAD 000 700 31 302930 28 29 31 32 33 1: 1 3:11 2 3 4 5 7 8 19 20 6 21 24 25 26 27 28 29 30 31 32 23 9 11 12 13 17 18 10 16 15 14 22 SITE SECTION 25' 30' 40' 50' 25' 30' 40' 50' 0+00 0+70 55'55' ACCESS ROAD POINT TABLE POINT NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 NORTHING 182303.66 182306.10 182396.21 182398.65 182396.98 182396.68 182401.01 182400.36 182417.62 182418.69 182422.84 182423.17 182441.72 182438.74 182438.16 182436.37 182440.35 182439.16 182419.84 182392.32 EASTING 1298173.68 1298173.21 1298155.81 1298155.34 1298155.11 1298153.54 1298153.12 1298148.82 1298145.63 1298149.85 1298148.57 1298150.14 1298146.50 1298142.08 1298142.32 1298132.57 1298131.66 1298125.56 1298129.11 1298136.67 DESCRIPTION FACE OF CURB FACE OF CURB FACE OF CURB FACE OF CURB EDGE OF PAVEMENT EDGE OF PAVEMENT CENTER OF RADIUS EDGE OF PAVEMENT EDGE OF PAVEMENT CENTER OF RADIUS EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT ELEV. 27.50 27.02 27.49 28.00 27.50 27.53 27.48 27.66 27.75 26.97 27.55 26.97 28.07 28.18 27.66 27.47 27.50 27.50 27.31 27.53 N/A MATCH EXISTING MATCH EXISTING MATCH EXISTING BOLLARD POINT TABLE POINT NO. 28 29 30 31 32 NORTHING 182321.93 182325.85 182329.78 182333.70 182337.62 EASTING 1298157.47 1298156.68 1298155.90 1298155.11 1298154.32 DESCRIPTION REMOVABLE BOLLARD REMOVABLE BOLLARD REMOVABLE BOLLARD REMOVABLE BOLLARD REMOVABLE BOLLARD N/A MATCH EXISTING ACCESS ROAD POINT TABLE POINT NO. 21 22 23 24 25 26 27 NORTHING 182381.35 182343.19 182316.07 182313.70 182316.46 182305.61 182306.01 EASTING 1298144.78 1298152.44 1298157.88 1298158.36 1298168.99 1298170.71 1298172.67 DESCRIPTION EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT CENTER OF RADIUS EDGE OF PAVEMENT EDGE OF PAVEMENT ELEV. 27.70 27.52 27.31 27.29 27.05 26.97 26.93 N/A MATCH EXISTING LJBRJFJan 20, 2023Jan 20, 2023REN21-0234WHBPS-D-C04.DWGSHOWN C03 5 32 DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2" DRAWING IS FULL SCALE WHEN BAR MEASURES 2" SCALE:PROPOSED SITE AND FINAL GRADINGPLANCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECTCITY OF RENTONWEST HILL BOOSTER PUMP STATIONIMPROVEMENTS PROJECT001/20/23 ISSUED FOR BIDDINGLJB RJF PROPOSED SITE PLAN EG AND FUEL TANK CONCRETE SLAB NOMINAL EL: 27.67' OUTLINE OF ROOF OVERHANG EXISTING GRADE FINAL GRADE PROPOSED GENERATOR STRUCTURE PROPOSED GENERATOR N: 182312.66E: 1298140.89 TOP OF WALL EL: 33.33' FINAL GRADE EL: 32.33' N: 182339.78 E: 1298135.45 TOP OF WALL EL: 33.33' FINAL GRADE EL: 32.33' 92' DEPRESSED CURB PER COR STD PLAN 101 13.5' EXISTING WEST HILL BOOSTER PUMP STATION R11.0' R4.3' 01 GRADE TO NOMINAL EL: 28.5' 2" MULCH COVER, PROVIDE MIN. 6' CLEAR SPACE IN FRONT OF ELECTRICAL EQUIPMENT. 33.33' 32.33' TOP OF WALL TOP OF FINISHED GRADE AT WALL TRANSFORMER WORK SPACE AREA PER PSE 3 13 ASPHALT DRIVEWAY RESTORE CONCRETE GUTTER AND ASPHALT PER COR STD PLAN 103 EXPANSION JOINT ALONG ALL CONCRETE-ASPHALT CONNECTIONS PER COR STD PLAN KEY NOTES CONCRETE FILLED STEEL REMOVABLE BOLLARDS, TYP. OF 5. APPROX. 4 FEET SPACING BETWEEN EACH BOLLARD CHAIN LINK FENCE CAST IN-PLACE CONCRETE RETAINING WALL PER DWG NO. S01 EG SHELTER TO BE SUPPORTED ON RETAINING WALL, SEE STRUCTURAL DRAWINGS FOR DETAILS CONCRETE STEP RESTORE FENCE IF DISTURBED BY CONSTRUCTION ACTIVITIES TO EXISTING OR BETTER CONDITIONS REMOVE AND REPLACE EXISTING CHAIN LINK FENCE WITH BARBED WIRE TO MATCH EXISTING FENCE, SEE DWG NO. E03 FOR REQUIRED TRANSFORMER WORK SPACE AREA SEE DWG NO. E03 FOR ADDITIONAL FIBER OPTIC INFORMATION CONCRETE TRAFFIC CURB TO MATCH EXISTING GROUND LEVEL BEHIND NEW CONCRETE TRAFFIC CURB PER COR STD PLAN 101 (TYP.), SEE POINT TABLE FOR FACE OF CURB TOP OF ROADWAY ELEVATION MAN ACCESS GATE PROPOSED ASPHALT DRIVEWAY SECTION MIN. 4" COMPACTED DEPTH HMA CL.12", PG64-22 COMPACTED IN TWO LIFTS. 6" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE COMPACTED TO 95% MODIFIED PROCTOR COMPACTED AND PROOF ROLLED NATIVE SUBGRADE 01 2% MIN. R4.3' CEMENT CONCRETE TRAFFIC CURB PER COR STD PLAN 101 DEPRESSED CURB PER COR STD PLAN 101 1 MIN. 2" 6" PERFORATED PIPE WITH GEOTEXTILE FABRIC PER DWG NO. S01, TRANSITION DRAINAGE PIPE TO 3" AS NECESSARY TO CAST THROUGH THE CONCRETE TRAFFIC CURB. DAYLIGHT AT CURB FACE AND SHEET FLOW ACROSS DRIVEWAY 11 CONTRACTOR TO VERIFY EXISTING DEPTH OF WATER AND FIBER OPTIC LINE PRIOR TO POWER AND TELEMETRY CONDUIT INSTALLATIONS 8 RESTORE ALL DISTURBED UNPAVED AREAS WITH SOD OR HYDROSEED 3" PERFORATED DRAIN LINE ROUTED PER PLAN, PROVIDE SCREENED OUTLET. TYP. OF 2 PRESSURE WASH INTERIOR AND EXTERIOR OF FACILITY AND RECOAT IN ACCORDANCE WITH THE SPECIFICATIONS3.5 ftExtend new conduit to pole # 204 (A1366494) Build new riser at pole Splice new to existing Open trench (2) 4" Schd 40 PVC @ 4.5' minimum depth Approx. 118ft Place new ANMW-200 in new conduit Maintain min 4ft separation from storm Remove aerial cable after cut over aer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-telaer-tel Remove existing 3048 HH & Replace with new 264-TA Install additional (1) 4" PVC from vault to pole 13.9 ft13.9 ft4.5 ftMFP23003514 REVDESCRIPTIONBYDATESTRUCTURAL NOTESGENERAL NOTESAPPROVEDKS02/16/2023MFP23003514