HomeMy WebLinkAbout320.1CORPORATION STOP 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET,
FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ
TUBING 1" TYPE "K" SOFT COPPER TUBING
METER SETTER
1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK
VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER
B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS
WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY
METER BOX METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ
"RENTON WATER"
COUPLER AND PLUG COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO
PROPERTY IS TO BE INSTALLED IN THE FUTURE
GRAVEL 1 1 4" WASHED GRAVEL PROPERTY LINECITY
PIPING PIPING
PRIVATE
F
BCB
A
D E
FINISHED GRADE
SIDEWALK
9" TO 12"
IN UNIMPROVED ROW,
INSTALL METER BOX
AT PROPERTY LINE WITH
1" COPPER TAILPIECE
21" TO 30"
LOOP DOWN TO CENTERLINE OF WATER MAIN
TO PROVIDE SLACK IN SERVICE LINE TO METER
22 1 2°
24" TO 30"
MAIN
12"PROPERTY LINEA
MATERIALS
B
C
D
E
F
G
G
PUBLIC WORKS
DEPARTMENT
APPROVED:
DATEMartin Pastucha
Public Works Administrator
1" WATER SERVICE
STD. PLAN - 320.1
6/28/2023