HomeMy WebLinkAboutMFP23003589.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23003589 IVR Number: 23003589 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:07/10/2023Application Date:0622059143Parcel Number: 9533 S 192ND ST Permit Type:07/18/2023Issue Date:Franchise Permit Work Class:07/17/2024Expiration Date:Minor Utility Job Number: 186058991Franchise Type:Electric Description: Puget Sound Energy Electric REPLACE 2 DIST POLES @ GRIDS P11 315988 166217 & P12 315988 166231. ZIPTIE SEC to NUET FROM GRID P06 316001 165882 to P06A316034 165894. ZIPTIE SEC to NUET FROM GRIDS P07 315996 166055 to P08 315994 166071. RETENTION TO NUET FROM GRIDS P09315996 166087 to P08 315994 166071. NO HS CUTS Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering PLEASE SEE ATTACHED POTELCO, INC 6905 S 228TH ST KENT, WA 98032 186058991 9533 S 192ND ST JOSE COSME 253-294-5875 MFP23003589 Scott Warlick CED Monday - Friday 8:00AM - 3:00PM 7/18/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG P06A P06 10101010 S 55TH ST TALBOT RD S TALBOT RD S10VAR 1016 1111 97TH AVE SS 192ND ST S 53RD PL1616 TALBOT RD S1010 STOP FLAGGER STOP FLAGGER STOP FLAGGER STOP FLAGGER W20-7ROADWORK AHEAD W20-1W20-4ONE LANEROADAHEAD350'350'350'W20-7ROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD350'350'350'W20-7ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'BIKESMERGE WITHTRAFFICW4-1BBIKELANEENDSW9-1BW20-7ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' W20-7ROADWORKAHEADW20-1 W20-4ONE LANEROADAHEAD100'100'100'X'X'PLACE W20-1 SIGNS ON ALL ADJACENT STREETS WITHIN FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-11050 THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA TEMPORARY TRAFFIC CONTROL PLAN Notes: 1. All signs and spacing to conform to the MUTCD and Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 30" x 30" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. PSE PUGETSOUNDENERGY JOB#186058991 9533 S 192ND ST, RENTON REV2 - 06/16/2023 FLAVIANA.RODRIGUESNUNES@PSE.COM 425-424-7809 Sheet 1 of 4 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY MFP23003589 P07P08P09SE 192ND STSE 192ND STSE 192ND ST102ND AVE SE 102ND AVE SE 1111 1010 161611111212 16 STOP FLAGGER STO P FLAGGER STOPFLAGGER STOP FLAGGER W20-7ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'W20-7ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ROADWORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'RESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSURETHE CREW SHALL CEASEWORK FOR A FLAGGER/SPOTTERTO ESCORT PEDESTRIANSAROUND THE WORK AREATEMPORARY TRAFFIC CONTROL PLANNPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425SIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 30" x 30" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOP POLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYPSEPUGETSOUNDENERGYJOB#186058991 9533 S 192ND ST, RENTONREV2 - 06/16/2023FLAVIANA.RODRIGUESNUNES@PSE.COM425-424-7809Sheet 2 of 4MFP23003589 P10SE 192ND ST11111010107TH AVE SE VAR.1112 SE 192ND ST106TH AVE SE 106TH AVE SE 121210101111 2911 STOP FLAGGERSTOP FLAGGER STOP FLAGGER STOP FLAGGER W20-7ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'W20-7ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ROAD WORK AHEAD W20-1W20-4ONE LANE ROAD AHEAD100'100'100'ROADWORKAHEADW20-1 100'RESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREP11TEMPORARY TRAFFIC CONTROL PLANNPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425SIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 30" x 30" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOP POLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYPSEPUGETSOUNDENERGYJOB#186058991 9533 S 192ND ST, RENTONREV2 - 06/16/2023FLAVIANA.RODRIGUESNUNES@PSE.COM425-424-7809Sheet 3 of 4MFP23003589 P10SE 192ND ST1111 1010107TH AVE SE VAR.1112 SE 192ND ST106TH AVE SE 106TH AVE SE 121210101111 2911 STOP FLAGGER STO P FLAGGER W20-7ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'W20-7ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ROAD WORK AHEAD W20-1W20-4ONE LANE ROAD AHEAD100'100'100'RESIDENT(S) WILL BE INFORMEDOF POSSIBLE TEMPORARYDRIVEWAY CLOSUREP11STO P FLAGGER W20-7ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'100'TEMPORARY TRAFFIC CONTROL PLANNPuget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425SIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 30" x 30" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOP POLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYPSEPUGETSOUNDENERGYJOB#186058991 9533 S 192ND ST, RENTONREV2 - 06/16/2023FLAVIANA.RODRIGUESNUNES@PSE.COM425-424-7809Sheet 4 of 4MFP23003589 80TH PL S"8041""18020"80TH PL S80TH AVE SINST NEWSW# X85176TREE TRIMMINGREQUIRED80TH PL S"18700""18506"GREENBELT AERAS 192ND ST"8605""8701"S 192ND STAØ39990BØ39991CØ3999280TH PL S80TH PL SAØ47792-1/0 ALBØ47793-1/0ALCØ47794-1/0AL80TH PL S80TH PL S3Ø DBL DE3Ø TAP3/8" PRI DOWN GUY3/8" NEUT DOWN GUY3/8" PRI DOWN GUY3/8" NEUT DOWN GUY510771746186058991101137900PROJECT PHASEPWRNOTIF#ORDER#SuperiorSub Order108127931N/APSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGSAP W.O. #186058991FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.OH CIRCUIT MAP: 2205E036,48,136SCALE 6" = 1 MILEJOB SITEARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.POWER GENERAL NOTES1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from thiswork sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three(3) working days in advance.3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing workto get the underground facilities located.4.All work is to be done in accordance with local municipal and county permit requirements as applicable.5.Inclement weather conditions may cause delays in construction times and dates.SCALE: 1:100SITE PLAN: P01DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPJ. COSME253-294-58756/2/23J. REYNA253-259-70766/2/23N/AN/AN/AK. O-SAWKAN/A6/2/23N/ACITY OF KENT/RENTONENGR1 EXTENET TK#510771746REPL (9) DIST POLES, REMOVE 3 SPOOL RACKS, REPLACE S/L8041 S 180TH ST, KENT WA 98032POTELCON/AN/AN/A186058991AS NOTED1/2KING COUNTYN/AN/AQCSOKET22-R05E-S06N/AN/A2205E014,131,1412205E036,48,1362304E131,141NOP-26N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AVICINITY MAPJOB SITESITE SPECIFIC NOTESP01 (316384-165440)TREE / BRUSH TRIMMING REQUIRED /KENT-REPLACE EXIST 45' CL1 POLE-INST NEW 50' CL1 POLE (6010.1000 PD501)-INST NEW 3Ø DBL PIN (6033.1020 ANG312)-INST NEW 9' C/O ARM (6011.1000 ARD1S09)-INST NEW 1Ø DE ARM-MOUNTED (6016.1000 DEDR21A) ON CENTER PHASE-INST NEW 3Ø OH-UG TERM (6043.1000 TSU3C1F) W/LB C/O's FUSED AT 25T (3412400) EA-INST NEW 4" RISER (6042.1000 RIS4CSS) ON S/O BKTS APPROX. 30' ( ') UP POLE-SPLICE AT BASE OF POLE NEW 3Ø 1/0 UG PRI AND EXTEND APPROX 40' (_____') IN NEW RISER-INST NEW SW# X85176-INST NEW 3/8" PRI DOWN GUY (6013.0100 GYD3SA) ATTACH TO EXIST ANCHOR-INST NEW 3/8" NEUT DOWN GUY (6013.0100 GYD3SAN) ATTACH TO EXIST ANCHOR-TRANSFER EXIST OH SEC-TOP POLE TO COMMSP02 (316242-165499) KENT-REPLACE EXIST 40' CL4 POLE-INST NEW 45' CL1 POLE (6010.1000 PD451)-INST NEW 3Ø DBL ARM (6033.1020 ANG312)-INST NEW 9' C/O ARM (6011.1000 ARD1S09)-INST NEW DE ARM-MOUNTED (6016.1000 DEDR21A) ON CENTER PHASE-INST NEW 3Ø OH-UG TERM (6043.1000 TSU3C1F) W/LB C/O's FUSED AT 100T (3412700) EA-INST NEW 4" RISER (6042.1000 RIS4CSS) ON S/O BKTS APPROX. 30' ( ') UP POLE-SPLICE AT BASE OF POLE NEW 3Ø 1/0 UG PRI AND EXTEND APPROX 40' (_____') IN NEW RISER-INST EXIST SW# X4450-INST NEW 3/8" PRI DOWN GUY (6013.0100 GYD3SA) ATTACH TO EXIST ANCHOR-INST NEW 3/8" NEUT DOWN GUY (6013.0100 GYD3SAN) ATTACH TO EXIST ANCHOR-TRANSFER EXIST S/L ARM (SLAM4327)-TRANSFER EXIST OH SEC-TOP POLE TO COMMSP03 (316038-165576) KENT-REPLACE EXIST 50' CL3 POLE-INST NEW 55' CL1 POLE (6010.1000 PD551)-INST NEW 3Ø DBL PIN (6033.1022 ANG313)-TRANSFER EXIST 25kVA 120/240V XF W/ LB C/O FUSED AT 10T (3412200)-INST NEW 3/8" PRI DOWN GUY (6013.0100 GYD3SA) ATTACH TO EXIST ANCHOR-INST NEW 3/8" NEUT DOWN GUY (6013.0100 GYD3SAN) ATTACH TO EXIST ANCHOR-TRANSFER EXIST S/L ARM (SLAU6413)-TRANSFER EXIST OH SEC-TOP POLE TO COMMSP04 (316006-165572) KENT-MISSING GRID#-INST NEW GRID #316006-165572-REPLACE EXIST 45' CL3 POLE-INST NEW 50' CLH2 POLE (6010.1000 PD50H2)-CREW TO DEEP SET POLE 1' - 0"-INST NEW 3Ø DBL DE (6033.1046 DDE3315)-INSTNEW 3Ø TAP (6033.5100 LAT312) W/ LI C/O FUSED AT 100T (3412700) SOUTH-INST EXIST SW# X82124-TRANSFER EXIST AMR UNIT-INST NEW 2" RISER (6042.1000 RIS2CSS) ON S/O BKTS APPROX. 35' ( ') UP POLE-SPLICE AT BASE OF POLE NEW 4/0 UG TPX AND EXTEND APPROX 40' (_____') IN NEW RISER-INST NEW 2 - 3/8" PRI DOWN GUY (6013.0100 GYD3SA) ATTACH TO EXIST ANCHOR-INST NEW 2 - 3/8" NEUT DOWN GUY (6013.0100 GYD3SAN) ATTACH TO EXIST ANCHOR-TRANSFER EXIST OH SEC-TOP POLE TO COMMSP05 (316006-165598) KENT-EXTEND EXIST 3" RISER APPROX 4' (_____') OR TO NEUT HEIGHT-SPLICE AND EXTEND 350 UG TPX 5'(___') IF NECESSARY-REMOVE EXIST GRASSHOPPER C/O-INST NEW LB C/O (6022.1000 DLS115L) FUSED AT 10T(3412200)-REMOVE EXIST 3-SPOOL RACK.-INST NEW RC-CLEAN DRIP LOOPS-CREW TO MAINTAIN SAFETY SPACE CLEARANCESSCALE: 1:100SITE PLAN: P02SCALE: 1:100SITE PLAN: P03-P05POLE TABLE (NEW)SITE#Pole DataGrid #HeightClassYearRemarks / Location Ref.P01316384-165440501P02316242-165499451P03316038-165576551P04316006-16557250H2 POLE RETIREMENT TABLE TEMP TRANSFERSST. LIGHT TRANSFERSSITE#POLE DATAPOLETELTVFIBERTRANRMVDID NUMBERGRID #HEIGHTCLASSYEARTOPPEDRMVDP01316384-1654404511986N/AP02316242-1654994041974SLAM 4327P03316038-1655765031988SLAU6413P04316006-1655724531981N/AUG CIRCUIT MAP @ P01: 2304E141SCALE 1:100UG CIRCUIT MAP @ P02: 2304E144SCALE 1:100New pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary Voltage P03316038-16557625kVA 120/240VSCALE: 1:100GUYING DETAIL AT: P04MFP23003589RESTORATION PER CITY OF RENTON STANDARDS '5420'S 192ND STTALBOT RD S'9533''9609'TREE TRIMMINGREQUIREDS 55TH STSE 192ND ST'19210''19201''10042''19045'102ND AVE SE SE 192ND ST'10215'SE 192ND STSE 192ND ST106TH AVE SE '19060''10617'107TH AVE SE107TH AVE SE'11330''11332'SE 192ND STBØAEM130'11619''11624''11807''11806''11825'116TH AVE SE SE 192ND STTREE TRIMMINGREQUIRED117TH PL SE'11637'TREE TRIMMINGREQUIREDDESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPJ. COSME253-294-58756/2/23J. REYNA253-259-70766/2/23N/AN/AN/AK. O-SAWKAN/A6/2/23N/ACITY OF KENT/RENTONENGR1 EXTENET TK#510771746REPL (9) DIST POLES, REMOVE 3 SPOOL RACKS, REPLACE S/L8041 S 180TH ST, KENT WA 98032POTELCON/AN/AN/A186058991AS NOTED2/2KING COUNTYN/AN/AQCSOKET22-R05E-S06N/AN/A2205E014,131,1412205E036,48,1362304E131,141NOP-26N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ASITE SPECIFIC NOTESP06 (316001-165882) TREE TRIMMING REQUIRED - RENTON-REPLACE EXIST DBL S/L ARM (SLAG9383)-INST NEW 16' SGL ARM S/L (6060.1000 AEWN16) 12" - 18" ABOVE TOP COMM-ZIPTIE SEC TO NEUT APPROX 165'(____') TO P06A-CREW TO MAINTAIN MIN. SAFETY SPACE CLEARANCESP07 (315996-166055) RENTON-ZIPTIE SEC TO NEUT APPROX 150' TO P08-CREW TO MAINTAIN MIN. 30" OF MIDSPAN CLEARANCEP08 (315996-166087) RENTON-EXTEND NEUT JUMPER AT FLYING TAP IF NECESSARY-RE-TENSION NEUT APPROX 175'(____') TO P09-CREW TO MAINTAIN 30" MIDSPAN SAFETY SPACE CLEARANCEP10 (315988-166217) RENTON-REPLACE EXIST 40' CL1 POLE-INST NEW 45' CL1 POLE (6010.1000 PD451)-INST 3Ø SINGLE ARM (6033.1012 TAN313)-TRANSFER EXIST 25kVA 120/240v XF-REMOVE EXIST GRASSHOPPER C/O-INST NEW LB C/O (6022.1000 DLS115L) FUSED AT 10T(3412200)-TRANSFER EXIST S/L ARM (SLAU3395)-TRANSFER EXIST OH SVC-TOP POLE TO COMMSP11 (315988-166231) RENTON-REPLACE EXIST 40' POLE-INST NEW 50' CLH2 POLE (6010.1000 PD50H2)-INST 3Ø PRI NEUT DBL DE (6033.3064 DDEP313)-INST NEW G/OP SWITCH (6022.2000 DLSG15)-INST NEW 2'' RISER (6042.1000 RIS2CSS) ON S/O BKTS APPROX. 40'(____') UP POLE-SPLICE AT BASE OF POLE NEW 4/0 UG TPX APPROX. 45'(____') THROUGH NEW RISER-REMOVE EXIST 3 SPOOL RACK-INST NEW RC-TRANSFER EXIST OH SVC-INST NEW 7/16'' PRI DOWN GUY (6013.0100 GYD7SA) ATTACH TO EXIST ANCHOR-TOP POLE TO COMMSSCALE: 1:100SITE PLAN: P06SCALE: 1:100SITE PLAN: P07-P09SITE PLAN: P10-P11SCALE: 1:100P12 (315988-166457) KENT-REMOVE EXIST 3-SPOOL RACK-INST NEW RC-CLEAN DRIP LOOPS-CREW TO MAINTAIN SAFETY SPACE CLEARANCESP13 (315985-166562) KENT-MISSING GRID#-INSTALL NEW GRID#: (315985-166562)-REPLACE EXIST 40' CL2 POLE-INST NEW 45' CLH1 POLE (6010.1000 PD45H1)-CREW TO DEEP SET 1' - 0"-INST NEW DBL CIR SGL ARM (6035.1010 TA215)-TRANSFER EXIST 15kVA 120/240V XF W/ LB C/O FUSED AT 6T (3412100)-TRANSFER EXIST AMR-TRANSFER EXIST OH SVC-TOP POLE TO COMMSP14 (315985-166588) KENT-REPLACE EXIST 45' CL4 POLE-INST NEW 45' CLH3 POLE (6010.1000 PD45H3)-CREW TO DEEP SET 1' - 6"-INST NEW DBL CIR SGL ARM DBL DELTA (6035.2010 DTA153)-TRANSFER EXIST 15kVA XF W/ LB C/O FUSED AT 6T (3412100)-INST NEW 1Ø TERM OH-UG (6043.1000 TSU1C1) W/LB C/O FUSED AT 40T (3412500)-INST NEW 2" RISER (6042.1000 RIS2CSS) ON S/O BKTS APPROX. 35' ( ') UP POLE-SPLICE AT BASE OF POLE NEW 1/0 UG PRI AND EXTEND APPROX. 40'( ') IN NEW RISER-INST EXIST SW# X9784-INST NEW 3" RISER (6042.1000 RIS3CSS) ON S/O BKTS APPROX. 35' ( ') UP POLE-SPLICE AT BASE OF POLE NEW 350 UG TPX AND EXTEND APPROX 40' (_____') IN NEW RISER-TRANSFER EXIST S/L (SLAP1372)-TRANSFER EXIST OH SVC-TOP POLE TO COMMSP15 (315985-166596) KENT-RE-FRAME DIST DELTA TO DBL CIR SGL ARM-INST NEW DBL CIR SGL ARM (6035.1010 TA215) RAISE DIST ARM 2' (_______)-RAISE LOWER TPX TO 36'-8" AGL-RAISE NEUT TO 26'=10" AGL-ZIP TIE TPX TO NEUT APPROX. 170'(____') TO P18-RAISE S/L ARM 12''-18'' (_______) ABOVE TOP COMMS-REMOVE TRANSMISSION GUYING SOUTH-CREW TO MAINTAIN 30" OF MIDSPAN SAFETY SPACE CLEARANCEP16 (315984-166615) KENT-REPLACE EXIST 40' CL1 POLE-INST NEW 45' CLH3 POLE (6010.1000 PD45H3)-CREW TO DEEP SET 1' - 6"-INST NEW 3Ø DBL CIR SGL ARM (6035.1010 TA2153)-TRANSFER & EXTEND EXIST 3" RISER APPROX 5' (_____')-SPLICE & EXTEND EXIST UG 350 TPX APPROX 5' (_____') AT TOP OF POLE-TRANSFER EXIST OH SVC-TOP POLE TO COMMSUG CIRCUIT MAP@P14: 2304E131SCALE 1:100New pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary Voltage P14315985-16658815kVA 120/240VNew pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary Voltage P10315988-16621725kVA 120/240VNew pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary Voltage P13315985-16656215kVA 120/240VSAP W.O. #186058991POLE TABLE (NEW)SITE#Pole DataGrid #HeightClassYearRemarks / Location Ref.P10315988-166217451P11315988-16623150H2P13315985-16656245H1P14315985-16658845H3P16315984-16661545H3 POLE RETIREMENT TABLE TEMP TRANSFERSST. LIGHT TRANSFERSSITE#POLE DATAPOLETELTVFIBERTRANRMVDID NUMBERGRID #HEIGHTCLASSYEARTOPPEDRMVDP10315988-1662174011975SLAU3395P11315988-16623140UNK1954P13315985-1665624021963N/AP14315985-1665884541963SLAP1372P16315984-1666154012011N/ASITE PLAN: P12SCALE: 1:100SITE PLAN: P13-P16SCALE: 1:100MFP23003589