Loading...
HomeMy WebLinkAboutMFP23000252.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP23000252 IVR Number: 23000252 Permit Information Permit Name: Verizon - MCI Kennydale West Lateral Address/Location:01/13/2023Application Date:3343301125Parcel Number: 1755 NE 48TH ST Permit Type:08/01/2023Issue Date:Franchise Permit Work Class:07/31/2024Expiration Date:Major Utility Job Number: 082357.01Franchise Type:Telephone Description: Verizon to install 1 2" HDPE conduit, 2 vaults, manholes, and pull fiber cable in the ROW. Install via 741 LF of directional boring and 149 LF of trenching. Pothole all existing utilities. Restoration per City of Renton standards. PRE CONSTRUCTION MEETING REQUIRED. SCHEDULE WITH WSDOT 405 PROJECT AND CITY OF RENTON. Contacts Name Address PhoneTypeBilling Mic Woodman Woodman Telcom Group 2225 East Murray Holladay Road Suite 101, Suite 101 SALT LAKE CITY, UT 84117 B: (801) 618-4664 C: (801) 599-9869 ApplicantX Kevin Schenck Utility Technologies Inc PO Box 1355 Woodinville, WA 98072 B: (425) 205-2190 C: (206) 730-7327 Contractor Business License Number: 50205Construction Contractor: UTILITI857DS PUBLIC STORAGE PO BOX 25025 GLENDALE , CA 91201 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering x x NFL/SEAHAWKS LATERAL BUILD TBD 1755 NE 48TH STREET, RENTON, WA 98056 04/24/23 06/30/23 9:00 AM 4:00 PM UTILITY TECHNOLOGIES KURT MOORE 206-396-1431 18612 144TH AVENUE NORTHEAST WOODINVILLE, WA 98072 DIRECTIONAL BORE TO PLACE NEW DUCT, PLACE HH IN CITY ROW TO FACILITATE PLACEMENT OF NEW CABLE MFP23000252 3:00pmMonday - Friday Scott Warlick CED 8/1/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Mic Woodman 10/18/22 GENERAL NOTES:TRAFFIC CONTROL PLANSHORT TERM STATIONARY WORK ZONEFOR UNDERGROUND WORKW20-1AHEADWORKROADW20-5DRIVEWAYL/2CENTER LANEAHEADCLOSEDAHEADWORKROADW20-1KEEPRIGHTR9-9CLOSEDSIDEWALKR4-7BRSE 76TH STR9-9XW20-5RRIGHT LANEAHEADCLOSEDW20-1AHEADWORKROADXW4-2RWORK ZONEDRIVEWAYSIGN SPACING = X (FEET)LBRL/2CLOSEDSIDEWALKALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.BUFFER DATALONGITUDINAL BUFFER SPACE = BTRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = RXXLAKE WASHINGTON BLVD NE LAKE WASHINGTON BLVD NEXX PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1300950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYMFP23000252 GENERAL NOTES:W20-1AHEADWORKROADW20-5DRIVEWAYRBLCENTER LANEAHEADCLOSEDAHEADWORKROADW20-1WORK ZONESE 76TH STR9-9CLOSEDSIDEWALKXW20-5CENTER LANEAHEADCLOSEDW20-1AHEADWORKROADDRIVEWAYSIGN SPACING = X (FEET)6 DEVICE MIN50'-100'STAGINGAREAR9-9CLOSEDSIDEWALKALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.XXLAKE WASHINGTON BLVD NE LAKE WASHINGTON BLVD NEXX TRAFFIC CONTROL PLANSHORT TERM STATIONARY WORK ZONEFOR UNDERGROUND WORKBUFFER DATALONGITUDINAL BUFFER SPACE = BTRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = RPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1400950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYMFP23000252 GENERAL NOTES:W20-1AHEADWORKROADW20-5LAHEADCLOSEDLEFT LANECLOSEDSIDEWALKR9-9SIGN SPACING = X (FEET)W1-4LW20-5RRIGHT LANEDRIVEWAYWORK ZONERALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.R9-9CLOSEDSIDEWALKSE 76TH STK2-1717BUFFER DATALONGITUDINAL BUFFER SPACE = BW1-4LTRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.W20-5RPROTECTIVE VEHICLE (WORK VEHICLE) = RRIGHT LANEAHEADCLOSEDCROSSWALKCLOSEDDRIVEWAYSTAGINGBLAHEADCLOSEDAHEADWORKROADW20-1W20-1AHEADWORKROADXXXLAKE WASHINGTON BLVD NE LAKE WASHINGTON BLVD NEXXX6 DEVICE MIN50'-100'XX AREATRAFFIC CONTROL PLANSHORT TERM STATIONARY WORK ZONEFOR UNDERGROUND WORKPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1500950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYMFP23000252 GENERAL NOTES:TRAFFIC CONTROL PLANSHORT TERM STATIONARY WORK ZONEFOR UNDERGROUND WORKBUFFER DATALONGITUDINAL BUFFER SPACE = BSIGN SPACING = X (FEET)TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = RALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.W20-1AHEADWORKROADW1-4LAHEADCLOSED6 DEVICE MIN50'-100'WORK ZONEW20-5RRIGHT LANEAHEADWORKROADW20-1RBLLAKE WASHINGTON BLVD NELAKE WASHINGTON BLVD NEXW20-1AHEADWORKROADCLOSEDW20-5CENTER LANEAHEADXKEEPRIGHTR4-7BRXXXNE 48TH ST X PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1600950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYMFP23000252 MCImetroACCESS TRANSMISSION SERVICES LLCOUTSIDE PLANT CONSTRUCTIONFIBER OPTIC CABLE ROUTEKENNYDALE WEST LATERAL1755 NE 48TH STRENTON, WA 98056OSP PROJECT #: 082357.01SITE CODE: STTLWAPROJECT STATUS: PERMITTINGMFP23000252This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR LOCATION MAPNORTHVICINITY MAPPROJECT MAPRENTON, WAREVISIONSDATEDESCRIPTIONINITIALPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST02002N/AN/AAMW16RENTON, WAKING COUNTYMFP23000252 CONTACT SHEETPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST03003N/AN/AAMWMANAGER:PROJECT SUPERINTENDENT:NAME OF FIRM:PROJECT COORDINATOR:TSO MANAGER:PROJECT MANAGER:PROGRAM MANAGER:SPLICING MANAGER:LIGHTWAVE ENGINEER:CIVIL ENGINEER:TERMINAL CONST. REP.:NON MEMBERS:COORDINATOR:ROW AGENT:MANAGER:MANAGER:PROJECT ENGINEER:PROJECT COORDINATOR:PROJECT ENGINEER:MANAGER:PROJECT COORDINATOR:UTILITIESMCI UTILITY LOCATE RAILROADSFEDERAL GOVERNMENTOTHERCOUNTY GOVERNMENTSTATE GOVERNMENT1-800-624-9675CITY GOVERNMENTOUTSIDE PLANT CONSTRUCTION:KENNY TERHUNE(425) 301-8658MCIKENNY TERHUNE(425) 301-8658BOB HAYES(972) 791-1537ENGINEERING CONTRACTORWOODMAN TELCOM GROUP, LLC2225 EAST MURRAY-HOLLADAY RDSALT LAKE CITY, UT 84117MIC WOODMANOFFICE:(801) 618-4664 X 202FAX:(801) 405-7001OFFICE:(801) 618-4664 X 202CELL: (801) 599-9869E-MAILMIC@WOODMANTELCO.COMWASHDOT - JIM RHODESN/AN/AN/ACONSTRUCTION CONTRACTOR16CITY OF RENTON PUBLIC WORKS (206) 402-8626N/AMFP23000252 GENERAL NOTES / CLARIFICATION NOTESADDENDUM NOTESCLARIFICATION NOTES1.7.5.6.4.3.2.GENERAL NOTESCLARIFICATION NOTES (CONTINUED)3. LOCATIONS OF SOME OF THE PHYSICAL FEATURES WERE OBTAINED FROM DATED RAILROAD EVALUATIONMAPS OR OTHER DRAWINGS AND MAY NOT BE AS SHOWN OR DEPICTED ON THESE DRAWINGS.4. UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS AND FIELD OBSERVATIONS BUTARE NOT NECESSARILY EXACT. THEREFORE, UTILITY LOCATIONS WILL BE VERIFIED AT LEAST 100 FEET INADVANCE OF TRENCHING OR PLOWING, SO THAT CHANGES IN CABLE PLACEMENT CAN BE MADE IN THE EVENTOF CONFLICT.5.ALL KNOWN BURIED OBSTRUCTIONS ARE SHOWN ON THE CONSTRUCTION DRAWINGS. ANY AND ALL OTHERSENCOUNTERED ARE ALSO THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT AND REPAIR IFDAMAGED.6. ANY AND ALL IMPROVEMENTS, SUCH AS ASPHALT OR CONCRETE PAVEMENT, CURBS, GUTTERS, WALKS,DRAINAGE DITCHES, EMBANKMENTS, SHRUBS, TREES, GRASS SOD, ETC., IF DAMAGED, SHALL BE RESTOREDTO ORIGINAL CONDITION.7. EQUIPMENT TYPES SPECIFIED HEREIN (IE: "BACKHOE", SWAMP PLOW" ETC.) ARE SUGGESTIONS ONLY AND ARENOT INTENDED AS REQUIREMENTS. CONTRACTOR WILL BE NOTIFIED AS TO EXPECTATIONS.9. BURIED CABLE MARKERS WILL BE PLACED AT ALL UNDERGROUND UTILITY LOCATIONS AND ALL OTHERLOCATIONS IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND THE OUTSIDE PLANT HANDBOOK.8. SHORING OF BORE PITS AND TRENCHES IN ACCORDANCE WITH OSHA REGULATIONS IS MANDATORY.10. ALL 4" ID CONDUIT WILL BE SCHEDULE 40 (EG.: PVC OR GSP/BSP), OR AS SPECIFIED.11. UNDERGROUND CONDUIT WILL BE PLACED AT 48" MINIMUM COVER UNLESS OTHERWISE SPECIFIED ON THECONSTRUCTION DRAWINGS.2. ALL WORK TO BE PERFORMED IN STRICT ACCORDANCE WITH THE APPLICABLE CODES ORREQUIREMENTS OF ANY REGULATING GOVERNMENTAL AGENCY, VERIZON BUSINESS AND THERIGHT-OF-WAY GRANTOR.1. VERIZON BUSINESS COMPRISES THE FOLLOWING OPERATING ENTITIES:- MCI COMMUNICATIONS SERVICES, INC.- MCI METRO COMMUNICATIONS SERVICES, INC.- MCI METRO ACCESS TRANSMISSION SERVICES OF VIRGINIA, INC.- MCI METRO ACCESS TRANSMISSION SERVICES OF MASSACHUSETTS, INC.- METROPOLITAN FIBER SYSTEMS OF NEW YORK, INC.4. QUANTITY LINEAR FOOTAGE/SQUARE FOOTAGE, SIZE OFMANHOLE/HANDHOLE SIZE OF PULL/SPLICE BOX, DIMENSION OF WALL,HEIGHT/CLASS/TYPE OF POLE5. TYPICAL DRAWING NO. AND TYPICAL DETAIL DRAWING NUMBER6. PLANT ACCOUNTING CODE7. SPECIFIED CONDUIT, HANDHOLE/MANHOLE NO., SPECIFIED PURPOSE ANDMATERIAL, BRIDGE NO. AND RAILROAD STATION, MATERIAL, POLE NO.1. STATION2. LOCATION3. CLARIFICATION NO. AND MINIMUM COVERPLACE BURIED CABLE MARKERS AND SIGNS/MWCOMPLACE ISOLATOR/PROTECTION SYSTEM AT EXISTINGWATER CROSSING SIGNSHANDHOLES/MANHOLESREMOVE CONCRETE BURIED CABLE MARKER POSTREMOVE BURIED CABLE MARKER POST/HARDWAREDIRECTIONAL BOREEMBEDMENT PLOW700710711630620ATTACH CONDUIT TO WALL OR STRUCTUREJETTING CONDUITREMOVE POLE/PUSH BRACEPLACE POLE/PUSH BRACEREMOVE AERIAL CABLERELASH AERIAL CABLEDELASH AERIAL CABLERELOCATE AERIAL CABLEPLACE AERIAL CABLEREMOVE AND DISPOSE OF CABLEEXPOSE DIRECT BURIED CABLE AND RELOCATEEXPOSE DIRECT BURIED CABLEDIRECT BURY CABLEREPOSITION ACTIVE CABLE SLACKREMOVE CABLE FROM CONDUITPULL THROUGH DUCT (INNERDUCT)ATTACH PULL/SPLICE BOX TO WALL OR STRUCTUREDETACH CONDUIT FROM WALL OR STRUCTUREREMOVE AND RESTORE CURBINGREMOVE AND RESTORE SIDEWALK610600500 526535528530527517525520515516510330320315310400300PULL CABLE420415411410CORE BORE282281PLACE HIGH DENSITY POLYETHYLENE (HDPE)REMOVE AND RESTORE CONCRETEREMOVE AND RESTORE ASPHALTCONSTRUCT WALLREPLACE/SUBSTITUTE PRECAST MANHOLERELOCATE PRECAST MANHOLEREMOVE EXISTING MANHOLEPLACE MANHOLEEXCAVATE SPLICE PITREPLACE/SUBSTITUTE HANDHOLERELOCATE HANHOLEREMOVE EXISTING HANDHOLEPLACE CONDUITEXPOSE CONDUITPLACE HANDHOLEREMOVE CONCRETE CAP REMOVE CONCRETE ENCASEMENTCONCRETE ENCASEEXPOSE AND REMOVE CONDUIT (ABANDONED)EXPOSE AND REMOVE CONDUITEXPOSE CONDUIT AND REPLACE/SUBSTITUTEEXPOSE CONDUIT AND RELOCATESLURRY BACKFILL ADDERJACK AND DRY BORE CONDUIT(S)240 222250256270280 260255252247 245244 221 220 219217216215213212 200100218ROCK ADDER214110714712210246713GENERAL NOTES / CLARIFICATION NOTESADDENDUM NOTESCLARIFICATION NOTES1.7.5.6.4.3.2.GENERAL NOTESCLARIFICATION NOTES (CONTINUED)3. LOCATIONS OF SOME OF THE PHYSICAL FEATURES WERE OBTAINED FROM DATED RAILROAD EVALUATIONMAPS OR OTHER DRAWINGS AND MAY NOT BE AS SHOWN OR DEPICTED ON THESE DRAWINGS.4. UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS AND FIELD OBSERVATIONS BUTARE NOT NECESSARILY EXACT. THEREFORE, UTILITY LOCATIONS WILL BE VERIFIED AT LEAST 100 FEET INADVANCE OF TRENCHING OR PLOWING, SO THAT CHANGES IN CABLE PLACEMENT CAN BE MADE IN THE EVENTOF CONFLICT.5.ALL KNOWN BURIED OBSTRUCTIONS ARE SHOWN ON THE CONSTRUCTION DRAWINGS. ANY AND ALL OTHERSENCOUNTERED ARE ALSO THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT AND REPAIR IFDAMAGED.6. ANY AND ALL IMPROVEMENTS, SUCH AS ASPHALT OR CONCRETE PAVEMENT, CURBS, GUTTERS, WALKS,DRAINAGE DITCHES, EMBANKMENTS, SHRUBS, TREES, GRASS SOD, ETC., IF DAMAGED, SHALL BE RESTOREDTO ORIGINAL CONDITION.7. EQUIPMENT TYPES SPECIFIED HEREIN (IE: "BACKHOE", SWAMP PLOW" ETC.) ARE SUGGESTIONS ONLY AND ARENOT INTENDED AS REQUIREMENTS. CONTRACTOR WILL BE NOTIFIED AS TO EXPECTATIONS.9. BURIED CABLE MARKERS WILL BE PLACED AT ALL UNDERGROUND UTILITY LOCATIONS AND ALL OTHERLOCATIONS IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND THE OUTSIDE PLANT HANDBOOK.8. SHORING OF BORE PITS AND TRENCHES IN ACCORDANCE WITH OSHA REGULATIONS IS MANDATORY.10. ALL 4" ID CONDUIT WILL BE SCHEDULE 40 (EG.: PVC OR GSP/BSP), OR AS SPECIFIED.11. UNDERGROUND CONDUIT WILL BE PLACED AT 48" MINIMUM COVER UNLESS OTHERWISE SPECIFIED ON THECONSTRUCTION DRAWINGS.2. ALL WORK TO BE PERFORMED IN STRICT ACCORDANCE WITH THE APPLICABLE CODES ORREQUIREMENTS OF ANY REGULATING GOVERNMENTAL AGENCY, VERIZON BUSINESS AND THERIGHT-OF-WAY GRANTOR.1. VERIZON BUSINESS COMPRISES THE FOLLOWING OPERATING ENTITIES:- MCI COMMUNICATIONS SERVICES, INC.- MCI METRO COMMUNICATIONS SERVICES, INC.- MCI METRO ACCESS TRANSMISSION SERVICES OF VIRGINIA, INC.- MCI METRO ACCESS TRANSMISSION SERVICES OF MASSACHUSETTS, INC.- METROPOLITAN FIBER SYSTEMS OF NEW YORK, INC.4. QUANTITY LINEAR FOOTAGE/SQUARE FOOTAGE, SIZE OFMANHOLE/HANDHOLE SIZE OF PULL/SPLICE BOX, DIMENSION OF WALL,HEIGHT/CLASS/TYPE OF POLE5. TYPICAL DRAWING NO. AND TYPICAL DETAIL DRAWING NUMBER6. PLANT ACCOUNTING CODE7. SPECIFIED CONDUIT, HANDHOLE/MANHOLE NO., SPECIFIED PURPOSE ANDMATERIAL, BRIDGE NO. AND RAILROAD STATION, MATERIAL, POLE NO.1. STATION2. LOCATION3. CLARIFICATION NO. AND MINIMUM COVERPLACE BURIED CABLE MARKERS AND SIGNS/MWCOMPLACE ISOLATOR/PROTECTION SYSTEM AT EXISTINGWATER CROSSING SIGNSHANDHOLES/MANHOLESREMOVE CONCRETE BURIED CABLE MARKER POSTREMOVE BURIED CABLE MARKER POST/HARDWAREDIRECTIONAL BOREEMBEDMENT PLOW700710711630620ATTACH CONDUIT TO WALL OR STRUCTUREJETTING CONDUITREMOVE POLE/PUSH BRACEPLACE POLE/PUSH BRACEREMOVE AERIAL CABLERELASH AERIAL CABLEDELASH AERIAL CABLERELOCATE AERIAL CABLEPLACE AERIAL CABLEREMOVE AND DISPOSE OF CABLEEXPOSE DIRECT BURIED CABLE AND RELOCATEEXPOSE DIRECT BURIED CABLEDIRECT BURY CABLEREPOSITION ACTIVE CABLE SLACKREMOVE CABLE FROM CONDUITPULL THROUGH DUCT (INNERDUCT)ATTACH PULL/SPLICE BOX TO WALL OR STRUCTUREDETACH CONDUIT FROM WALL OR STRUCTUREREMOVE AND RESTORE CURBINGREMOVE AND RESTORE SIDEWALK610600500 526535528530527517525520515516510330320315310400300PULL CABLE420415411410CORE BORE282281PLACE HIGH DENSITY POLYETHYLENE (HDPE)REMOVE AND RESTORE CONCRETEREMOVE AND RESTORE ASPHALTCONSTRUCT WALLREPLACE/SUBSTITUTE PRECAST MANHOLERELOCATE PRECAST MANHOLEREMOVE EXISTING MANHOLEPLACE MANHOLEEXCAVATE SPLICE PITREPLACE/SUBSTITUTE HANDHOLERELOCATE HANHOLEREMOVE EXISTING HANDHOLEPLACE CONDUITEXPOSE CONDUITPLACE HANDHOLEREMOVE CONCRETE CAP REMOVE CONCRETE ENCASEMENTCONCRETE ENCASEEXPOSE AND REMOVE CONDUIT (ABANDONED)EXPOSE AND REMOVE CONDUITEXPOSE CONDUIT AND REPLACE/SUBSTITUTEEXPOSE CONDUIT AND RELOCATESLURRY BACKFILL ADDERJACK AND DRY BORE CONDUIT(S)240 222250256270280 260255252247 245244 221 220 219217216215213212 200100218ROCK ADDER214110714712210246713PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST04004N/AN/AAMWREVISIONSDATEDESCRIPTIONINITIAL16MFP23000252 MCI OUTSIDE PLANT FOCUSMCI OUTSIDE PLANT CONSTRUCTION GENERAL REQUIREMENTSFIBER OPTIC CABLE UNCOVERING SYSTEMPRIOR TO ANY EXCAVATION, THE MCI EMPLOYEE OR CONTRACT REPRESENTATIVE MUST VERIFY THEINITIAL LOCATE MARKS COMPLETED BY MCI OPERATIONS. DO NOT TRUST LOCATE RESULTSCOMPLETED BY OTHERS THE MCI OR CONTRACT REPRESENTATIVE MUST LOCATE THE CABLERUNNING LINE BY MAKING AT LEAST ONE PASS IN EACH DIRECTION. LOCATE RESULTS MUST THEN BECOMPARED WITH PREVIOUS MARKS AND THE AS-BUILTS.IF THE PROPOSED WORK INVOLVES DIGGING OR EXCAVATING WITHIN 3 FEET OF THE CABLE, THECABLE ROUTE WILL BE MARKED CONTINUALLY WITH ORANGE PAINT AND SUPPLEMENTED BYMARKER FLAGS PLACED EVERY 10 FT. THE EXCAVATION CONTRACTOR MUST POTHOLE (ALLPOTHOLES MUST BE COMPLETED BY HAND DIGGING OR VACUUM EXCAVATION) A MINIMUM OFEVERY 15 FT., THEN EXPOSE THE ENTIRE LENGTH OF THE CABLE BY HAND DIGGING OR VACUUMEXCAVATION.IF THE PROPOSED WORK INVOLVES DIGGING OR EXCAVATING WITHIN 5 FEET (BUT NOT CLOSERTHAN 3 FEET) OF THE CABLE, THE CABLE ROUTE WILL BE MARKED CONTINUALLY WITH ORANGEPAINT AND SUPPLEMENTED BY MARKER FLAGS PLACED EVERY 10 FT. THE EXCAVATIONCONTRACTOR MUST POTHOLE THE CABLE A MINIMUM OF EVERY 15 FT.IF THE PROPOSED WORK INVOLVES DIGGING OR EXCAVATING WITHIN 5 FEET (BUT NOT CLOSERTHAN 3 FEET) OF THE CABLE, THE CABLE ROUTE WILL BE MARKED CONTINUALLY WITH ORANGEPAINT AND SUPPLEMENTED BY MARKER FLAGS PLACED EVERY 10 FT. THE EXCAVATIONCONTRACTOR MUST POTHOLE THE CABLE A MINIMUM OF EVERY 15 FT.THE CABLE WILL ALSO BE POTHOLED AT ANY CHANGE IN THE RUNNING LINE OF MORE THAN 1 FT.IN ANY DIRECTION, ANYTIME THE ACCURACY OF THE ELECTRONIC LOCATE IS QUESTIONED, ORTHE MARKED RUNNING LINE DOES NOT MATCH THE AS-BUILTS.NO MECHANICAL EXCAVATION WITHIN 3 FT. OF OSP FACILITIES WILL BE ALLOWED UNLESS THEFACILITIES HAVE FIRST BEEN PROPERLY LOCATED, POTHOLED, POSITIVELY IDENTIFIED,CONTINUOUSLY EXPOSED BY HAND DIGGING OR VACUUM EXCAVATION, AND THE FACILITES ARECLEARLY VISIBLE.IN ADDITION, MECHANICAL EXCAVATION WITHIN 3 FT. OF OSP FACILITIES REQUIRES ON-SITE PRIORAPPROVAL FROM MCI'S EMPLOYEE OR CONTRACT REPRESENTATIVE.7. PLEASE REFER TO THE LATEST EDITION OF THE MCI OSP HANDBOOK FOR ADDITIONAL DETAILS. KNOWIT AND FOLLOW IT.1. THE TITLE OF THIS PROGRAM, F.O.C.U.S., AN ACRONYM FOR "FIBER OPTIC CABLE UNCOVERINGSYSTEM," WAS SELECTED TO REMIND EVERYONE INVOLVED WITH WORKING NEAR MCI'S ACTIVE FIBEROPTIC SYSTEMS TO FOCUS ON PROTECTING THE FACILITIES. IF, DURING THE COURSE OF THE PROJECT,YOU NOTICE ANY ACTIVITY WHICH MAY JEOPARDIZE THE MCI OSP FACILITIES, IT IS YOUR DUTY TO STOPTHE WORK AND RE-F.O.C.U.S.2. F.O.C.U.S. RULES MUST BE FOLLOWED ON ALL MCI PROJECTS INVOLVING WORK ON OR NEAR MCI OSPFACILITIES. SAFETY IS MCI'S NUMBER ONE PRIORITY; EVERYONE MUST REFRAIN FROM UNSAFE ANDIMPROPER PRACTICES.3. REVIEW OF F.O.C.U.S. IS MANDATORY AT EVERY PRE-BID, PRE-CONSRUCTION SITE MEETING AND DAILYTAILGATE MEETING. F.O.C.U.S. DISCUSSION MUST INCLUDE SITE-SPECIFIC HISTORY, UNIQUE PROBLEMS,FACILITY CONFIGURATIONS THAT MAY BE ENCOUNTERED, AND PAST ERRORS. "THOSE WHO DO NOTLEARN FROM HISTORY ARE DOOMED TO REPEAT IT." DO NOT LET THIS HAPPEN TO YOU.4. ANY WORK NEAR OR REQUIRING HANDLING OF MCI OUTSIDE PLANT FACILITIES CAN ONLY BEPERFORMED WITH AN MCI EMPLOYEE OR CONTRACT REPRESENTATIVE PRESENT -- THIS MEANS OUT OFHIS OR HER VEHICLE AND DIRECTLY MONITORING THE WORK. THE REPRESENTATIVE MUST HAVE APROPERLY OPERATING CABLE LOCATOR CHECKED FOR ACCURACY EVERY DAY PRIOR TOCOMMENCEMENT OF WORK (COMPARISON OF LINE AND DEPTH READINGS TO ACTUAL LINE AND DEPTHOF THE CABLE).TOOLS AND EQUIPMENT SPECIFICALLY DESIGNED FOR THE JOB AT HAND AREREQUIRED. USE THE PROPER TOOL FOR THE JOB.PROTECTING MCI FACILITIES IS EXTREMELY IMPORTANT; HOWEVER, SAFETYREGARDING YOURSELF AND OTHERS IS THE MOST IMPORTANT PART OF ANYPROJECT.CONTRACTORS ARE NOT ALLOWED TO CUT ANY CABLE. CABLES SCHEDULED FORREMOVAL WILL BE CUT BY MCI OPERATIONS PERSONNEL, AND ONLY AFTERVERIFICATION THAT ALL TRAFFIC HAS BEEN OFF-LOADED.PERSONAL PROTECTIVE EQUIPMENT APPROPRIATE FOR THE SPECIFIC WORK SITESHALL BE USED AT ALL TIMES. AT A MINIMUM, HARD HAT, SAFETY SHOES/STEEL-TOEDBOOTS, AND FLORESCENT ORANGE OR GREEN WORK VEST ARE REQUIRED UPONENTERING ANY MCI WORK SITE.USE OF INTOXICANTS, DRUGS, INHALANTS OR ANY OTHER SUBSTANCES THAT MAYIMPAIR ALERTNESS ARE STRICTLY PROHIBITED.EXTREME CAUTION MUST BE USED AT ALL TIMES WHEN WORKING ON OR NEARACTIVE CABLES. AN MCI EMPLOYEE OR CONTRACT REPRESENTATIVE MUSTAPPROVE AND BE PRESENT PRIOR TO AND DURING ALL CABLE HANDLINGACTIVITIES.CONDUIT WORK INVOLVING ACTIVE CABLES REQUIRES SPECIALIZED TOOLSSPECIFICALLY DESIGNED TO ACCESS DUCTS WITH ACTIVE CABLES.5. LOCATE AND POTHOLE REQUIREMENTS:6. EXPOSING REQUIREMENTS:ALL FEDERAL, STATE AND LOCAL SAFETY REGULATIONS MUST BE FOLLOWEDWITHOUT EXCEPTION.PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST05004N/AN/ABMWREVISIONSDATEDESCRIPTIONINITIAL16FOREMAN SIGNATUREDATEMFP23000252 PROJECT SPECIFICCLARIFICATION SUMMARY SHEETPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST06004N/AN/ACMWPROJECT CLARIFICATION SUMMARYCLARIFICATIONNUMBERCLARIFICATIONNUMBER ANDALPHADESCRIPTIONQUANTITYUNITREVISIONSDATEDESCRIPTIONINITIAL16210PLACE (2)-2" HDPE DUCTS880LF200PULL (1)-864CT FOC THRU HDPE (SLACK NOT INCLUDED)878LF410400PLACE 3060 HAND HOLE1EA240PULL (1)-10AWG TRACE WIRE878LFDIRECTIONAL BORE TO PLACE NEW CONDUIT832LF630600212TRENCH TO PLACE (2)-2" HDPE DUCTS46LF212TRENCH TO PLACE (1)-2" HDPE DUCT2LFMFP23000252 REVISIONSDATEDESCRIPTIONINITIALOVERHEAD GUY (ARROW IN DIRECTION OF PULL)C/LR/WTAX DISTRICTCITY, COUNTY OR STATE BOUNDARY LINEFENCE LINETOP OF SLOPETOE OF SLOPEPROPERTY LINEGUARDRAILF/LMAIN TRACKSAUXILLARY TRACKSCENTERLINERIGHT-OF-WAYUNDERGROUND UTILITY (TELEPHONE)AERIAL UTILITY (ELECTRIC)DITCH LINETO BE REMOVED OR ABANDONED(SHOWN FOR HDPE)SIDEWALKEDGE OF PAVEMENTF/LF/LF/LF/LF/LRAILROAD SIGNAL CONTROL BOXCAUTION NOTEGAS VALVEFIRE HYDRANTD/LS/WEOPD/LS/WEOPR/WC/LTEHTHECULVERT (SIZE AS INDICATED)BRIDGEWATER METERBOND AND GROUNDSIDEWALK ANCHOR AND GUYPUSH BRACE (EXISTING POLE)ACCOUNT CODE CHANGE (BURIED TO AERIAL)FOREIGN ANCHOR AND GUY DIRECT BURIED HDPEPVC OR SPLIT PVC CONDUITBSP/GSP OR SPLIT BSP/GSP CONDUITJACK AND BOREFUTURE CABLEREMOVE AND RESTORE ASPHALT OR CONCRETE(WIDTH AS INDICATED)DIRECTIONAL BORECORE BOREREMOVE CABLESTEEL CASINGBURIED CABLESUBMARINE CABLEAERIAL CABLEFOGWIRE CABLEDASHED = NOT FOUND IN FIELD48''48''ANCHOR AND GUYGUY ONLYPOLEANCHOR ONLYPERMIT TRACKING FORM IDENTIFIER HANDHOLE, MANHOLE OR PULLBOXUTILITY COVER DEPTHROCK PROBE (DEPTH AS INDICATED)SYMBOLS KEYFOGWSUBMEXISTINGFOGWSUBMPROPOSEDSTEEL MARKER AND SIGN-(A)ALUMINUM "HUB"-STYLE MARKER-(B)FLAT MARKER-(C)TUBULAR MARKER-(D)TUBULAR MARKER, & ISOLATOR PROTECTOR-(E)MILE POST MARKERNOTE: AERIAL FIBERCAUTIONACTIVE MCICAUTIONBURIED FIBEROPTIC CABLEA C T I V E M C I OPTIC CABLE30'-5-84B&GB&G12"30'-5-8412"PBSTA. STA. STA. STA. STA. STA. 48"42"187P.T.F.OHG92' 10MP=OHGP=48"18742"P.T.F.92' 10M(C)PROPOSED(B)(A)(C)2121(D)STA. STA. MKR. # MKR. # STA. MKR. # MKR. #STA. (E)(A)(B)STA. MKR. # STA. MKR. # STA. MKR. # STA. EXISTING(D)21(E)MKR. # STA. MKR. # STA. MKR. #DBDBPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST07005N/AN/AAMW16MFP23000252 CONSTRUCTION DETAILSCROSS SECTION OF PROPOSED HDPE SDR-11PROPOSED FIBER OPTIC CABLETYPICAL DETAILCONDUIT AS SPECIFIEDE/W ANY NUMBER OFINNERDUCTS AND /ORHDPE's AS SPECIFIED"B" MIN.TRENCH & PLACE CONDUITCOVERTYPICAL DETAIL6" MIN.EXISTING GRADEBURIED CABLEMARKER TAPECOMPACT BACKFILLS IN6" LAYERS WITH ROCKFREE MATERIALCONDUIT AS SPECIFIED E/WANY NUMBER OF INNERDUCTSAND/OR HDPE's, AS SPECIFIED& FIBER OPTIC CABLE12" MIN. BELOWFINISHED GRADE"A"48"PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST08006N/AN/AAMW3" CORE BORENOTE:EPOXY GROUT IS USED AT BOTH ENDS OF CORE BORE TOSEAL GAP BETWEEN 2.375" CONDUIT AND PVC SLEEVE.1-2.375" O.D. HDPEEPOXIED INTO 3"DIAM. CORE BORE1-2.375" O.D. HDPE3" O.D. DIAMETERCORE BORECONCRETE ORROCK HEADWALL(WHERE OCCURS)TYPICAL DETAIL "C"REVISIONSDATEDESCRIPTIONINITIALPROPOSED1-4" CONDUIT &FIBER CABLEBURIED CABLEMARKER TAPECOMPACT BACKFILLSIN 6" LAYERS WITHROCK FREE MATERIAL6"MIN.6"MIN.REMOVE AND REPLACE ASPH. AND CONCRETEEXISTINGASPHALTCONCRETESUB BASE(VARIES PER PERMIT REQUIREMENT)ASPHALT PAVEMENT OPEN CUTTYPICAL DETAIL "D"CROSS SECTION18" MIN.4" MIN.12"MIN.6"6"MIN.16" MIN.48" MIN.3" MIN.16MFP23000252 PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST09006N/AN/ACMWREVISIONSDATEDESCRIPTIONINITIAL2.5' x 5' x 2.5' 30K STANDARD HANDHOLE DETAILSBBAA66 1/8"63 3/8"60"59"18"29"4 1/2"10"1 3/4"3 1/2"36 1/8"33 3/8"30"5"4 1/2" KNOCKOUTS2 EACH END (4x)2 1/2"KNOCKOUTS1 EACH END(2x)2" KNOCKOUTS1 EACH END (2x)SLOTTED DRAIN(4x)8"ØSUMP30"M C I800 MCI-WORK30KM C I800 MCI-WORK30KUNISTRUTSUPPORT BEAM(2x)LOCKDOWN(2x)LIFT PIN(2x)SEE DETAIL A-1EMS MAKER (1x)NON-SKIDSURFACESEE DETAIL A-2FLUSH MOUNTPOLYMER CONCRETECOVERARMORCASTLOGO (2x)OPEN BASEPOLYMER CONCRETEDETACHABLE BASESLOTTED DRAIN(4x)LIFTING BOLT2 EACH SIDEWALLRUBBER COVER1/2" S.S. BOLTDOWNDETAIL "A"EXPLODED ISOMETRIC DETAILDETAIL "B"LOCKING DEVICECROSS SECTIONDETAIL "C"FLUSH MOUNTCOVER DETAILDETAIL A-1DETAIL A-2SECTION A-ASECTION B-BITEM123NOTE: SEALED PLASTIC BAG PLACED INSIDE VAULT TO CONTAIN:QTY(1)(2)MATERIALJOHNNY LOCK KEYS.S. JOHNNY BOLT W/ FLAT WASHERSHRINK WRAP COVERS TO FRAME FOR PACKAGING16MFP23000252 GATE 6' CL F 6' CLFW-98MW -2 0 W-104-20 W-105-20 W-106-20 W-136MW -2 0W-136 - 20 W-13 9C P- 20 W-175C P -2 0W-241VW -2 1 W-5TP - 20 12"DECID 2 X12"DECI D 6'CLF 5'CLF5 X18"DECID30"DECID W-240- 21 /W-6TP- 20 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD MCIMCIMCI M C I MC I MCI 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 8+78 4904 L A K E W A S H I N G T O N B L V D 1755 NE 48TH ST 6'5'8'5'8'5'4' 5' 6' 5'INDEX SHEETRENTON, WAKING COUNTYSHEET 11PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST10009N/AN/AAMWNORTH16SHEET 12MFP23000252 6' CLFW-98MW-2012"DECID2 X12"DECID6'CLFW-240-21/W-6TP-20MCIMCIMCIMCI MCI MCI BORE PITSTA. 0+50EXISTING MCI BUILDINGENTRANCE VAULTACCESS VAULT TO PLACENEW DUCT & FIBERDIRECTIONAL BORE 238' TO PLACE (2)-2"HDPE SDR-11 DUCTSPULL 238' NEW MCI 864CT FOC & 10AWGTRACER WIRE THROUGH NEW CONDUITTRENCH 46' TO PLACE (2)-2" HDPE SDR-11 DUCTSPULL 46' NEW MCI 864CT FOC & 10AWG TRACER WIRETHROUGH NEW CONDUIT0+001+00 2+00 3+004+00BORE PITSTA. 2+84BORE PITSTA. 2+381755 NE 48TH STDIRECTIONAL BORE 132' TO PLACE (2)-2"HDPE SDR-11 DUCTSPULL 132' NEW MCI 864CT FOC & 10AWGTRACER WIRE THROUGH NEW CONDUIT6'5'8'5'8'5'4'PROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1100950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811CLARIFICATION NO.QUANTITY410416'21246'210416'630370'UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYSEE SHEETTO MATCH SURVEY STA.124+164100+001416'PULL 864CT FOC2122+38446'TRENCH2102+38546'PLACE CONDUIT6300+002238'DIRECTIONALBORE2100+003238'PLACE CONDUIT6302+846132'DIRECTIONALBORE2102+847132'PLACE CONDUITPothole all existingutility crossingwhen boring.Schedule 80 isrequire within Rightof WaySchedule 80 isrequired within CityRight of WayMFP23000252RESTORATION PER CITY OF RENTON STANDARDS 6' CLFMCIMCIMCIMCIMCIMCIMCIMCIMCIMCIBORE PITSTA. 5+885+006+00 7+00 8+00 8+78 DIRECTIONAL BORE 172' TO PLACE (2)-2"HDPE SDR-11 DUCTSPULL 172' NEW MCI 864CT FOC & 10AWGTRACER WIRE THROUGH NEW CONDUITPLACE NEW MCI 3060 HHACCESS VAULT TO PLACENEW DUCT & FIBERDIRECTIONAL BORE 290' TO PLACE (2)-2"HDPE SDR-11 DUCTSPULL 290' NEW MCI 864CT FOC & 10AWGTRACER WIRE THROUGH NEW CONDUIT4904 LAKE WASHINGTON BLVDDIRECTIONAL BORE 132' TO PLACE (2)-2"HDPE SDR-11 DUCTSPULL 132' NEW MCI 864CT FOC & 10AWGTRACER WIRE THROUGH NEW CONDUIT5'6'5'TRENCH 2' TO PLACE(1)-2" DUCT TO PSE POLE#31977-166428 & TIE DUCTTO EX. RISER ON POLEPROJECT:SCALETO MPMPEXCEPT AS MAY BE OTHERWISE PROVIDED BYCONTRACT, THESE DRAWINGS AND SPECIFICATIONSSHALL REMAIN THE PROPERTY OF MCICOMMUNICATIONS SERVICES INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANYPURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC ROUTE OUTSIDE PLANT CONSTRUCTION MCImetro ACCESS TRANSMISSION SERVICES LLC 082357.01DATE:ENGINEER:DRAWN BY:HORIZONTAL:VERTICAL:SHEETOFFILE:12/19/2022WOODMAN TELCOMW.T.G032422-1KENNYDALE WEST HUB ENTRNACE1"=1"=RENTON, WA 98056REVISIONSDATEDESCRIPTIONINITIAL12/19/2022DESIGNMW1755 NE 48TH ST1200950'N/AAMWNORTHCALL BEFORE YOU DIG72 HOURS NOTICE REQUIRED1-800-624-9675 or 811CLARIFICATION NO.QUANTITY410462'210464'24012122'UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS ANDFIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. IT IS THE CONTRACTORSRESPONSIBILITY TO FIELD LOCATE ALL UNDERGROUND OBSTRUCTIONS ANDUTILITIES PRIOR TO CONSTRUCTION. COMPLETE REPAIR OF ANY AND ALLDAMAGES INCURRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.16RENTON, WAKING COUNTYSEE SHEET TO MATCH SURVEY STA.11 4+16 4104+161462'PULL 864CT FOC2408+7841PLACE HANDHOLE6304+162462'DIRECTIONALBORE2104+163462'PLACE CONDUIT2128+7862'TRENCH2108+7872'PLACE CONDUITSchedule 80 conduit is requiredwithin the Right of WayMFP23000252