HomeMy WebLinkAboutWEST EAST TOWER FINISHES L-1 L-2 PARKING GARAGE ELEVATORS Schedule Update 7.4.23Agency Listings 2-Wire Photoelectric Duct Smoke Detector The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec) • Versatile mounting options in square or rectangular configuration with modular construction • Plug-in sensor • Superb false alarm immunity with the latest sensor technology • Broader ranges for operating temperature (−4°F to 158°F) and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover • Increased wiring space with a newly added ¾ inch conduit knockout • Improved LED status • 24 VDC • Backward compatibility with existing Innovair products, including remote accessories The InnovairFlex D2 2-wire photoelectric duct smoke detector features a pivoting housing that fits various applications: both square and rectangular footprints mount to round or rectangular duct work. This new duct smoke detector senses airflow speeds ranging from 100 to 4,000 feet per minute with proven System Sensor precision. The enhancements built into this model improve false alarm immunity (with plug-in sensor head); broaden operating temperature (−4°F to 158°F) and humidity (0 to 95 percent non- condensing) ranges; while simplifying installation and maintenance. These advance features can detect smoke even in the harshest duct applications. The new design provides more wiring space with an added ¾ inch conduit knockout. Numbers and labels for terminal designations are consistent with previous Innovair models. The new sampling tube can be clicked into position with one smooth motion from either the front or the back of the detector. The InnovairFlex D2 duct smoke detector has signals to indicate trouble and maintenance conditions. Additionally, a cover tamper feature is incorporated to indicate a trouble condition for removed or improperly installed sensor cover. An improved cover design, with an integrated the low-flow feature, isolates the sensor head from the low-flow technology for simple maintenance. The InnovairFlex series is designed for greater flexibility and reliable smoke detection to simplify installation and maintenance. The new InnovairFlex product line is backward compatible to existing Innovair models, including remote test accessories WARNING: Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building’s regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector application information.S911 3029700 3242-1653:206 2202 RECEIVED 06/06/2017 striplett BUILDING DIVISION F17002659 By: cthomas Date: 06/07/2017 FIRE DEPARTMENT For Construction Subject to Corrections Noted in Red APPROVED A05-0421-002 InnovairFlex Duct Smoke Detector Specifications Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex™ D2 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4000 ft/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12–18 AWG wiring. Physical Specifications Size: (Rectangular) (Square) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.36 cm) Depth 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight:1.8 lb (0.82 kg) Operating Temperature Range:-4°F to 158°F (-20°C to 70°C) Storage Temperature Range:–22°F to 158°F (–30°C to 70°C) Operating Humidity Range:0% to 95% relative humidity non-condensing Air Duct Velocity:100 to 4000 ft/min (0.5 to 20.32 m/sec) Electrical Ratings Power supply voltage:8.5-35 VDC Input capacitance:0.1 µF max. Reset voltage:2.5 VDC min. Reset time: (with RTS451)0.03 to 0.3 sec. Reset time: (by power down)0.3 sec. max. Power up time:35 sec. max. Alarm response time:15 sec. Sensitivity Test:See detector label Current Requirements: (Using No Accessories) Peak standby current:120µA Max. standby current:60 µA (average) Max. alarm current:130 mA Accessory Current Loads at 24 VDC Device Standby Alarm RA100Z 0 mA 12 mA Max. RTS151 0 mA 12 mA Max. RTS151KEY 12 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). (+) IN (+) OUT (+) (+) (–) (–) 1ST DETECTORIN LOOP D2 (–) RA100Z (OPTIONAL)REMOTE ALARM LED 4.4 VDC NOM.IN ALARM (+) IN (+) OUT (+) (+) (–) LAST DETECTORIN LOOP D2 (–) RA100Z (OPTIONAL)REMOTE ALARM LED 4.4 VDC NOM.IN ALARM EOLR STYLE D OPTIONAL WIRING UL/FM LISTEDCOMPATIBLE 2-WIRECONTROL PANEL ALARMINITIATIONLOOP (+) (–) EOL RESISTORSPECIFIEDBY PANELMANUFACTURER RA RA RA RA (–)~~~~(+) IN (+) OUT (+) (+) (–) (–) 2ND DETECTORIN LOOP D2 (–) RA100Z (OPTIONAL)REMOTE ALARM LED 4.4 VDC NOM.IN ALARM RA RA ~~~~A05-0421-002 Wiring for 2-wire Duct Smoke Detector System wiring diagram for 2-wire duct smoke detectors (powered from initiating device circuit): 24 VAC (+10%, –15%)FULL WAVE RECTIFIED,UNFILTERED POWERMAY BE USED RTS151/RTS151KEY(OPTIONAL) REMOTETEST STATION MAGNETTESTSWITCH ALARMLED (RED) 4 5 2 1 (+) (–) + RA + RTS – RA + TEST COIL – TEST COIL + IN + OUT – (–) (+) D2 24 VDCAUX POWERSUPPLIEDBY USER(100mASUPPLY) RTS151/RTS151KEY(OPTIONAL) REMOTETEST STATION 24 VAC (+10%, –15%)FULL WAVE RECTIFIED,UNFILTERED POWERMAY BE USED MAGNETTESTSWITCH ALARMLED (RED) 4 5 2 1 (+) (–) + RA + RTS – RA + TEST COIL – TEST COIL + IN + OUT – 24 VDCAUX POWERSUPPLIEDBY USER(100mASUPPLY) D2 NOTE: THE USE OF EITHER THE RTS151 OR RTS151KEY REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD SEPARATELY. SEE FIGURE 9 ABOVE FOR REFERENCE. METHOD #1 - AUX POWER LOCATED AT DUCT DETECTOR METHOD #2 - AUX POWER LOCATEDAT TEST STATION Important Note The use of either RTS151 or RTS151KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the D2 installation manual for more information Wiring diagram for 2-wire duct smoke detector to RTS151/RTS151KEY Remote Test Station 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2010 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0421-002 • 9/10 • #2498 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. RTS151 UL S2522 RA100Z UL S2522RTS151KEY UL S2522 Ordering Information Part No.Description D2 2-wire photoelectric low-flow duct smoke detector Accessories 2151 2-wire conventional photoelectric sensor head DH400OE-1 Weatherproof enclosure DCOIL 2-wire remote test coil required with RTS451/RTS451KEY ETX Metal exhaust tube duct width 1ft (0.3m) DST1 Metal sampling tube duct width up to 1ft (0.3m)M02-04-00 Test magnet DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) P48-21-00 End cap for metal sampling tubes DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m)RA100Z Remote annunciator alarm LED DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m)RTS151 Remote test station DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m)RTS151KEY Remote test station with key lock