HomeMy WebLinkAboutPlanx F)*w Pa i __ 7 ~^£lU^£t_ j^££e Duct I w xt -* -flLPlHEFIRE AND SAFETY SYSTEMS, INC. 735 E. FAIRHAVEN AVENUE BURLINGTON, WA 98233 360-755-5444 CONTRACTOR LICENSE: ALPINFSO77RP PROJECT: Domino's Pizza 4020 NE 4th Street Renton, WA 98056 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION By: cthomas Date: 07/24/2017 FIRE DEPARTMENT For Construction Subject to Corrections Noted in Red APPROVED Fire and Safety Systems, Inc, Scope of work provided by Alpine Fire & Safety for Fire Suppression System installation Exhaust fans continue to operate during actuation of a kitchen hood fire extinguishing system. A permanent placard shall be installed in a visible location near the cooking equipment showing the type and placement of the cooking equipment being protected and all the information on the placement of the hood extinguishing system for future reference. Upon activation of the fire extinguishing system, an audible alarm or visual alarm shall be provided to show that the system has been activated, that personnel response is needed, and that the system is in need of recharge. • If a fire alarm system is installed in the building, the hood extinguishing system shall be connected to the fire alarm as a separate zone showing alarm and trouble signals. • All manual actuators shall be provided with operating instructions. • All remote manual operating systems shall be identified as to the hazard they protect. > Shutoff devices shall require manual resetting prior to fuel or power being restored. > Wet chemical containers and expellant gas assemblies shall not be located where they could be subject to mechanical, chemical or other damage. Wet chemical container and assemblies shall be located where they are accessible for inspecting, maintenance, and recharge. All discharge nozzles shall be designed, installed or protected so that they are not subject to mechanical, environmental or other conditions that could render them inoperative. All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors, moisture or other foreign materials into the piping. The protection device shall blow off or open upon agent discharge. Discharge nozzles shall be connected and supported such that they will not be readily put out of alignment. F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION ' Where the pipe or other conduit penetrates a duct or hood, the penetration shall have a liquid tight continuous external weld or shall be sealed by a listed device. • The kitchen extinguishing system shall meet the requirements of UL 300, NFPA 17A and NFPA 96. Upon activation of the extinguishing system, all sources of fuel and electrical power that produce heat to all equipment with required protection shall be automatically shut off. Any gas appliance not requiring protection but under the same hood shall be automatically shut off. Only persons trained and qualified to install the specific system being provided shall perform the installation. The installer shall provide certification to the authority having jurisdiction that the installation is in agreement with the terms of the listing and the manufacturer's instructions and or approved design. A minimum 6-liter size portable Class K extinguisher shall be mounted a maximum of 30 feet of travel distance from the cooking equipment. The Class K extinguisher should be visible from all three systems. 735 E. Fairhaven * P.O. Box 265 » Burlington, Washington 98233 « (360) 755-5444 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION a AIMSUL Bull~m by Tyco Fire Suppression & Building Products One Stanton Street Marinette, Wl 54143-2542 www.ansul.com Bulletin No. 5653 DATE: April 29, 2010 TO: All Authorized ANSUL R-102 System Distributors and OEMS's FROM: Product Management - Restaurant Systems SUBJECT: Non-UL-Listed .Fire Protection for Conveyor Pizza Ovens The UL300 Standard: Fire Testing of Fire Extinguishing System for Protection of Commercial Cooking Equipment does not currently address a test protocol for conveyor pizza oven protection. However, in many jurisdictions, the Authority Having Jurisdiction has required fire protection for conveyor pizza ovens. In the past, appliances not addressed in the UL300 test standard have been protected by following listed protection options for other appliances with similar operating characteristics. Generally, these appliances presented a more severe hazard than the appliance in question. In the case of conveyor pizza ovens, chain broiler protection was utilized. To confirm recommended protection, we recently conducted a conveyor pizza oven fire test following the chain broiler test protocol outlined in UL 300, substituting fatty hamburgers with a grease coated pizza crust, to emulate the cooking process used by conveyor pizza ovens. Prior recommendations for conveyor pizza ovens larger than the two 1N horizontal nozzle limitations for a chain broiler, suggested using four. 1N nozzles, each positioned at the end corners and aimed diagonally across the chain within the oven. Based on the actual fire testing, we now recommend two 245 nozzles per conveyor: one nozzle is positioned at the inlet and one nozzle is positioned at the outlet of the conveyor pizza oven on the same side of the oven and aimed at the opposite corners. Utilizing two 245 nozzles as recommended is suitable protection for conveyors- larger than the limitations for a chain broiler but not exceeding 38 in.(96.5 cm) wide x 70 in (177.8 cm) long. If you should have questions pertaining to this bulletin, please contact your U.S. District Manager or International Area Manager; or call Technical Services as noted below. Main Telephone Numbers: 1 -800-862-6785 or 1 -715-735-7415 Customer Services: Press 2 • Technical Services: Press 4 • Training Services: Press 6 • Quality Assurance: Press 8 Literature Fax Orders: 1 -800-543-9822 or 1 -715-732-3474 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION R-102 Restaurant Fire Suppression Manual SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-1 SYSTEM DESIGN TheANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary AUTOMAN Release can be either an R-102 or a PIRANHA AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA'Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- ate manual. • Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 in. (914 mm). • When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be protected with PIRANHA nozzles. • Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into 10 sub-sections: Nozzle Placement Requirements, Tank Quantity Requirements, Actuation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Station Requirements, Mechanical Gas Valve Requirements, Electrical Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each- of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quan- tity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. "Note: Ducts from multiple hoods connected to a common ductwork must be protected in compliance with NFPA 96 and >• all local codes. The R-102 system uses different duct nozzles depending on the size of duct being protected. GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (51 -203 mm) into the center of the duct opening, discharging up. See Figure 4-1. FIGURE 4-1 000173 2. In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (203 mm) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (203 mm) in this way will not void the UL listing of the system. 3. Previously listed three flow number and five flow number duct protection detailed in earlier published manual (Part No. 418087-06) can also still be utilized. DUCT SIZES UP TO 50 IN. (1270 mm) PERIMETER/16 IN. (406 mm) DIAMETER One 1W nozzle = one flow number 50 in. (1270 mm) perimeter maximum 16 in. (406 mm) diameter maximum DUCT SIZES UP TO 100 IN. (2540 mm) PERIMETER/32 IN. (812 mm) DIAMETER • One 2W nozzle = two flow numbers • 100 in. (2540 mm) perimeter maximum • 32 in. (812 mm) diameter maximum The chart below shows the maximum protection available from each duct nozzle. 3.0 Gallon Description System 2W Nozzle Maximum 100 in. (2540mm) Perimeter 1W Nozzle Maximum 50 in. (1270 mm) Perimeter 1.5 Gallon System Maximum 100 in. (2540mm) Perimeter Maximum 50 in. (1270 mm) Perimeter F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION R-102 Restaurant Fire Suppression Manual SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-3 Duct Protection - Multiple Nozzle (Continued) DUCT SIZES GREATER THAN 100 IN. (2540 mm) PERIMETER • Ducts over 100 in. (2540-mm) perimeter may be modularized using 2W nozzles • No round duct option available • Follow the design chart to determine maximum module size for each 2W nozzle • When determining number of nozzles required, it is sometimes an advantage to check the chart using the shortest side as Side "A" and then recheck it using the longest side as Side "A." This comparison may reveal a need for a lesser quantity of nozzles one way versus the other way. When working with Chart 4-1, the quantity of nozzles deter- mined must be equally divided within the duct area. CHART 4-1 In. SIDE "B" cm When working with Chart 4-2, one half of the quantity of nozzles determined must be equally positioned in the top half of the area of the duct and the remaining half of the nozzles must be positioned in the bottom half of the duct area. Example: The duct to be protected has a Side "A" of 40 in. (1016 mm) and a Side "B" of 60 in. (1524 mm). Referring to the design chart, this duct requires four nozzles. One half of 4 = 2. Therefore, two nozzles must be equally positioned in each of the two duct areas. See Figure 4-3. SIDE "B" 30 IN. (762 mm) 30 IN. (762 mm) 20 IN. (508 mm) SIDE "A" 20 IN. (508 mm) 40 IN. (1016mm) 60 IN. (1524 mm)" SIDE "A" in. 4 5 6 7 8 9 10 11 12 13 14 15 1.3 17 18 19 20 21 22_ 23 24 25 J6 27 _28_ 29 30 31 32 33 34 35 36 25 26 64 66 r 27 28 69 7 r i~ .29 30 74 76 r 31 32 79 8' 1 r 33 34 84 86 r 35 36 89 9' r r 37 38 94 97 r 39 40 99 102 r j 41 42 104107 c I 43 44 109 112 r i 45 46 114 117 r j 47 48 119122 r s 49 50 124 127 2 51 .52 130 i32 53 54 135 137 I I 55 56 MO 42 57 58 145147 J 59 60 150152 r i 6 61 62 155157 3 63 64 160163 J r 4 65 66 :65168 J 5 67 68 !70 173 r j 7 69 70 175 178 J 6 71 72 80183 -J r r in. cm 10 13 15 18 20 23 25 28 30 33 36 38 41 43 46 48 51 53 5B 58 61 64 66 69 71 74 76 79 81 84 86 89. .91 FIGURE 4-3 CHART 4-2 • • • • • • .36 37 33 39 40 41 42 •43 .44 45 .46 47 48 NOTE: NOZZLE QUANTITIES LISTED IN CHART 4-2 MUST BE EQUALLY DIVIDED INTO EACH OF THE TWO DUCT MODULES. 2 rJ r J 4 rI rJ • HJ j 6 91 •94 ;97 99 102 104 1lV •1.P9 ,112 •114 .W •119 •122 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION SECTION 4 - SYSTEM DESIGN UL EX3470 ULG EX3470 PAGE 4-4 REV. 11 2014-SEP-01 R-102 Restaurant Fire Suppression Manual Transition Protection Transitions are protected at a point in the transition where the perimeter or the diameter is equal to or less than the maximum size duct that can be protected: The nozzle{s) must be located in the center of the area at that point, or center of the module protected when more than one duct nozzle is required. Note: Nozzles to protect ducts with a transition that is more than 4 ft (1.2 m) in height, will be required to be positioned in the opening of the transition from the hood 2 to 8 in. (50 to 203 mm) into the opening using standard duct nozzle design parameters. See Figure 4-4. DUCT FIGURE 4-4 000174 Electrostatic Precipitator Protection Some restaurant ventilating ducts have an electrostatic precip- itator installed at or near the base. These precipitators are generally small and are used to aid in the cleaning of exhaust air. Ducts with precipitators located at or near the base can be protected using duct nozzle(s) above the precipitator and 1/2N nozzle(s) for the precipitator. One 1/2N nozzle must be used Mor each cell being protected. This nozzle is stamped with 1/2N, indicating that it is a 1/2-flow nozzle and must be counted as 1/2 flow number. When protecting ducts equipped with precipitators, the duct nozzle(s) must be installed above the precipitator and aimed to discharge downstream. If the area above the precipitator is a duct, the nozzle(s) must be positioned according to duct protec- tion guidelines. If the area above the precipitator is a transition, the transition guidelines must be followed. The 1/2N nozzle must be centered 10 to 26 in. (254 to 660 mm) below the precipitator and aimed to discharge at the center of each precipitator cell. However, if it is physically impossible to mount the nozzle at 10 to 26 in. (254 to 660 mm) due to precip- itator placement, the nozzle may be mounted closer than 10 in. (254 mm). See Figure 4-5. SEE DUCT FOR TRANSITION PROTECTION i * IF PHYSICALLY IMPOSSIBLE AT 10 TO 26 IN. (254 TO 660 mm), NOZZLE MAY BE MOUNTED CLOSER THAN 10 IN. (254 mm). FIGURE 4-5 OD012S Note: For protection of Pollution Control Units (PCUs) or air scrubbers with or without ESPs, contact Technical Services for non-UL listed recommended application. F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION R-W2 Restaurant Fire Suppression Manual SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-5 Plenum Protection The R-102 system uses the 1W nozzle or the 1N nozzle for plenum protection. The 1W nozzle is stamped with 1W and - the 1N nozzle is stamped with 1N, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL 1W NOZZLE - SINGLE AND "V BANK PROTECTION One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more .than 2 ft (0.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft (1.2 m) apart down the entire length of the plenum. The plenum width must not exceed 4 ft (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 4-6. Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. • (203-304 mm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (50 mm) from the perpendicular center line of the filter. See Figure 4-8. 2 FT (0.6 m) MAXIMUM 4 FT (1.2m) MAXIMUM4 FT (1.2 m) MAXIMUM^4 FT (1.2 m) MAXIMUM NOZZLE TIP MUST BE WFTHIN THIS AREA FIGURE 4-8 000200 HORIZONTAL PROTECTION - OPTION 1 1N NOZZLE SINGLE BANK PROTECTION • One 1N nozzle will protect 10 linear feet (3.0 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (50 to 102 mm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-152 mm) from the end of the hood to the tip of the nozzle. See Figure 4-9. FIGURE 4-6 000197 When protecting plenums with the 1W nozzle, two options of coverage are available: Option 1: The 1W nozzle must be on the center line of the single or "V" bank filter and positioned within 1-20 in. (26-508 mm) above the top edge of the filter. See Figure 4-7. FIGURE 4-9 20 IN. (503 mm) MAXIMUM FIGURE 4-7 OQQ199 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-6 REV. 11 2014-SEP-01 R-W2 Restaurant Fire Suppression Manual Plenum Protection (Continued) HORIZONTAL PROTECTION - OPTION 2 1W NOZZLE - "V" BANK PROTECTION One 1W nozzle will protect 6 linear feet (1.8 m) of "V bank plenum. The nozzle must be mounted horizontally, positioned 1/3 the filter height down from the top of the filter. Nozzles can be located at 6 ft (1.8 m) spacings on longer plenums. The nozzle must be positioned 0-6 in. (0-152 mm) from the end of the hood to the tip of the nozzle. See Figure 4-10. 1W NOZZLE For a plenum, either single or "V" bank, with a linear extension »• longer than 10 ft (3.0 m), each bank may be protected using one >• 1N nozzle every 10 ft (3.0 m) or less depending on the overall length of the plenum. See Figure 4-12. The nozzles may point in the opposite directions as long as the entire plenum area is >• protected, and the 10 ft (3.0 m) limitation is not exceeded. See Figure 4-13. The nozzle positioning shown in Figure 4-14 is not an acceptable method of protection because the plenum area directly under the tee is not within the discharge pattern of either nozzle. 10 FT (3.0 m) - MAXIMUM 10 FT (3.0m), MAXIMUM 10 FT (3.0m) MAXIMUM FIGURE 4-12 00020S FIGURE 4-10 OQB524 TWO 1N NOZZLES -"V" BANK PROTECTION > Two 1N nozzles will protect 10 linear feet (3.0 m) by 4 ft (1.2 m) wide of "V" bank plenum. The nozzles must be mounted in the »- plenum, 2 to 4 in. (50 to 101 mm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-381 mm) from the end of the hood to the tip of the nozzle. See Figure 4-11. FIGURE 4-13 000207 INCORRECT FIGURE 4-11 FIGURE 4-14 OOQ20S F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-28 REV. 11 2014-SEP-01 R-102 Restaurant Fire Suppression Manual Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. > Hazard Duct or Transition (Single Nozzle) Duct or Transition (Single Nozzle) Duct or Transition (Dual Nozzle) Electrostatic Precipitator (At Base of Duct) Plenum (Horizontal Protection) Plenum >• (Horizontal Protection) Plenum Maximum Hazard Dimensions Length - Unlimited Perimeter - 50 in. (1270 mm) Diameter - 1 6 in. (406 mm) Length - Unlimited Perimeter- 100 in. (2540 mm) Diameter -31 7/8 in. (809 mm) Length - Unlimited Perimeter- 150 in. (3810 mm) Diameter -48 in. (1219 mm) Individual Cell Length -10 ft (3.0m) Length -6 ft (1.8m) Width -4 ft (1.2m) Length -4 ft (1.2m) Minimum Nozzle Nozzle Quantity Heights 1 1 2 1 -j _ 1 1 Nozzle Part No. 439839 439840 439840 439837 439838 439839 439839 Nozzle Stamping Flow No. 1W 2W 2W 1/2N 1N 1W 1W (Vertical Protection) Fryer (Split or Non-Split Vat) Fryer (Split or Non-Split Vat) Fryer (Split or Non-Split Vat)* Width -4 ft (1.2m) Maximum Size (without drip board) 14 in. (355 mm) x 15 in. (381 mm) Low Proximity Maximum Size (without drip board) 141/2 in. (368 mm) x 14 in. (355 mm) Medium Proximity Maximum Size (without drip board) 15 in. (381 mm) x 14 in. (355 mm) High Proximity Medium Proximity Fryer (Non-Split Vat Only) Maximum Size (without drip board) 19 1/2 in. (495 mm) x 19 in. (482mm) High Proximity Low Proximity Maximum Size (without drip board) 18 in, (457mm) x18 in. (457 mm) High Proximity 13-16in. (330 - 406 mm) 16-27 in. (406 - 685 rnm) 27 - 47 in. 20 - 27 in. 21 - 34 in. 13-16 in. 25 - 35 in. (635 - 889 mm) 439845 290 439845 290 439842 439843 439841 439845 439841 230 245 3N 290 3N 1 For multiple nozzle protection of single fryers, see detailed information on Pages 4-10 and 4-11. F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION R-102 Restaurant Fire Suppression Manual SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-29 Nozzle Application Chart (Continued) Hazard Maximum Hazard Dimensions Minimum Nozzle Quantity Fryer (Non-Split Vat Only) Maximum Size (Continued) (without drip board) 141/2 in. (368 mm) x 16.5 in. (419mm) High Proximity 1 Fryer (Non-Split Maximum Size Vat Only)* (with drip board) 21 in. (533 mm) x 14 in. (355 mm) (Fry Pot must not exceed 15 in. x 14 in. (381 mm x 355 mm)) High Proximity 1 Medium Proximity 1 Maximum Size (with drip board) 25 3/8 in. (644 mm) x 19 1/2 in. (495mm) (Fry pot side must not exceed 19 1/2 in. (495 rhm)x 19 in. (483 mm) High Proximity 1 Low Proximity 1 Maximum Size (with drip board) 18 in. (457 mm) x 27 3/4 in. (704 mm) High Proximity 1 Maximum Size (with drip board) 14 1/2 in. (368 mm) x 26.5 in. (673 mm) High Proximity 1 Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 14 in. (355 mm) x 21 in. (533 mm) 1 Low Proximity Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 141/2 in. (368 mm) x 26 1/2 in. (673 mm) 1 Medium Proximity * For multiple nozzle protection of single fryers, see detailed information on Pages 4-10 and 4-11. Nozzle Heights 16-21 in. (406 - 533 mm) Nozzle Part No. 439845 Nozzle Stamping • Flow No. 290 27 - 47 in. (685-1193 mm) 20 - 27 in. (508 - 685 mm) 439842 439843 230 245 21 - 34 in. (533 - 863 mm) 13-16 in. (330 - 406 mm) 25 - 35 in. (635 - 889 mm) 16-21 in. (406 - 533 mm) 13-16 in. (330 - 406 mm) 16-27 in. (406 - 685 mm) 439841 439845 3N 290 439841 3N 439845 439845 439845 290 290 290 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-30 REV. 11 2014-SEP-01 R-102 Restaurant Fire Suppression Manual Nozzle Application Chart (Continued) Hazard Range Griddle Maximum Hazard Dimensions Longest Side (High Proximity) 32 in. (812 mm) Area - 384 in.2 (24774 mm2) Longest Side (Low Proximity) 24 in. (609 mm) Area-432 in.2 (27870 mm2) Longest Side 28 in. (711 mm) Area - 336 in.2 (21677mm2) Longest Side 32 in. (812mm) Area - 384 in.2 (24774 mm2) Longest Side (High Proximity) 28 in. (711 mm) Area - 672 in.2 (43354 mm2) Longest Side (Medium Proximity) 32 in. (812 mm) Area - 768 in.2 (49548 mm2) Longest Side (Low Proximity) 36 in. (914 mm) Area -1008 in.2 (65032 mm2) Longest Side (High Proximity) 48 in. (1219mm) Area-1440 in.2 (92903 mm2) Longest Side (High Proximity) 30 in. (762 mm) Area - 720 in.2 (46451 mm2) Longest Side (High Proximity) 36 in. (914mm) Area-1080 in.2 (69677 mm2) Longest Side (Medium Proximity) 48 in. (1219 mm) Area -1440 in.2 (92903 mm2) Longest Side (Low Proximity) 26 in. (660 mm) Area - 533 in.2 (34387 mm2) Minimum Nozzle Nozzle Nozzle Nozzle Stamping - Quantity Heights Part No. Flow No. 1 30-40 in. 439838 1N (762-1016 mm) 15-20 in. 439838 1N (381 - 508 mm) 40-48 in. 439836 1F (1016-1219 mm) (With Backshelf) 30 - 40 in. 439844 260 (762-1016 mm) (With Backshelf) 40 - 50 in. 439843 245 (1016-1219 mm) 30 - 40 in. 439844 260 (762-1016 mm) 15-20 in. 439845 290 (381 - 508 mm) 30 - 50 in. 439844 260 (762-1270 mm) (perimeter located) 30 - 50 in. 439845 290 (762-1270 mm) (center located) 35 - 40 in. (889-1016 mm) (perimeter located) 439838/439865 1N/1NSS 20 - 30 in. 439845 290 (508 - 762 mm) (perimeter located) 15-20 in. 439839 1W (381 - 508 mm) (center located) F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION R-102 Restaurant Fire Suppression Manual SECTION 4 - SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-31 Wozzle Application Chart (Continued) Hazard Griddle (Continued) >• Chain Broiler* >• (Overhead Protection) Chain Broiler (Horizontal Protection) > Gas-Radiant/Electric Char-Broiler Electric Char-Broiler Lava-Rock Broiler Natural Charcoal Broiler Lava-Rock or Natural Charcoal Char-Broiler Wood Fueled Char-Broiler Upright Broiler/ - Salamander Salamander Broiler Wok Maximum Hazard Dimensions Longest Side (Low Proximity) 36 in. (914mm) Area -1080 in.2 (69677 mm2) Longest Side (Low Proximity) 48 in. (1219mm) Area -1440 in.2 (92903 mm2) Length - 34 in. (863 mm) Width-32 in. (812mm) Length - 43 in. (1092 mm) Width - 31 in. (787 mm) Longest Side - 36 in. (914 mm) Area - 864 in.2 (55741 mm2) Longest Side - 34 in. (863 mm) Area - 680 in.2 (43870 mm2) Longest Side - 24 in. (609 mm) Area-312 in.2 (20128mm2) Longest Side - 24 in. (609 mm) Area - 288 in.2 (18580mm2) Longest Side - 30 in. (762 mm) 1 Area - 720 in.2 (46451 mm2) Longest Side - 30 in. (762 mm) 1 Area - 720 in.2 (46451 mm2) Length - 32.5 in. (825 mm) Width - 30 in. (762 mm) Length - 29 in. (736 mm) Width-16 in. (406mm) Length-31 in. (787mm) Width-15 in. (381 mm) Length - 31 in. (787 mm) Width-15 in. (381 mm) 14 in. - 30 in. (355 - 762 mm) Diameter 3;75 - 8.0 in. (95 - 203 mm) Deep 11 in. - 24 in. (279 - 609 mm) Diameter 3.0 - 6.0 in. (76 - 152 mm) Deep Minimum Nozzle Quantity 1 1 2 2 1 1 1 1 1 1 2 1 1 1 1 Nozzle Heights 10 -20 in. (254 - 508 mm) (perimeter located) 10 -20 in. (254 - 508 mm) (perimeter located) 10 -26 in. (254 - 660 mm) 1-3 in. (25 - 76 mm) 15 -40 in. (381 -101 6 mm) 20 - 50 in. (508 -1270 mm) 18 -35 in. (457 - 889 mm) 18 -40 in. (457 -101 6 mm) 14 -40 in. (355 -101 6 mm) 14 -40 in. (355 -1016 mm) - - - - 35 - 45 in. (889 -1143 mm) 30 - 40 in. (762 -101 6 mm) Nozzle Part No. 439840 439846 439839/439864 439838/439865 439838/439865 439838/439865 439838/439865 439838/439865 439841 439841 439837 439838 439836 439838 439844 439838/439865 Nozzle Stamping - Flow No. 2W 2120 1W/1WSS 1N/1NSS 1 N/1 NSS 1N/1NSS 1 N/1 NSS 1 N/1 NSS 3N 3N 1/2N 1N 1F 1N 260 1 N/1 NSS 1 Minimum chain broiler exhaust opening-12 in. x 12 in. (305 mm x 305 mm), and not less than 60% of internal broiler size. F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION Department of Labor and Industries PO Box 44450 Olympia, WA 98504-4450 170 ALPINE FIRE & SAFETY SYS INC PO BOX 265 735 E FATRHAVEN AVE BURLINGTON WA 98233 ALPINE FIRE & SAFETY SYS INC Reg; CC<ALPINFS077RP UBI: 6.01-218-336 Registered as_ provided by Law as: Construction Contractor (CC01) - GENERAL Effective Date: 1-2/17/1993 Expiration Date: 11/19/2018 F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION F17003414 RECEIVED 07/20/2017 lwalker BUILDING DIVISION