HomeMy WebLinkAboutM_ DATA SHEETS _092017_V1The IntelliKnight System is the easy wayto make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance inaddressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributedintelligent power, a modular design and an expanded, easy to use interface. Powerful features such as driftcompensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. IntelliKnight®Model 5820XLAddressable Fire Alarm Control System INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5820XL Description5820XL is an intelligent addressable fire alarm control panel (FACP). Thebasic 5820XL system can be expanded by adding modules such as 5860remote annunciator,5815XL signalling line circuit expander, 5824serial/parallel printer interface module (for printing system reports), and5895XLintelligent power module. 5820XL supports Hochiki or SK devices.5820XL also features a powerful built-in dual line fire communicator thatallows for reporting of all system activity to a remote monitoring location.Features•Built in support for 99 SK detectors and 99 SK modules, expandable to396 SK detectors and 396 SK modules using System Sensor protocol• Built in support for 127 Hochiki devices, expandable to 508 Hochikidevices using Hochiki protocol.• Uses standard wire—no shielded or twisted pair required• Built-in digital communicator• Central station reporting by point or by zone• Built-in synchronization for appliances from AMSECO®, Gentex®,Faraday, System Sensor, and Wheelock®• Flexput™ I/O circuits• Supports Class B (Style 4) and Class A (Style 6) configuration for SLC,SBUS, and Flexput circuits• Distributed, intelligent power• Drift compensation• 13 pre-programmed output cadences (including ANSI-3.41) and 4programmable outputs• Built-in annunciator with 80-character LCD display• RS-485 bus provides communication to system accessories• Built-in RS-232 and USB interface for programming via PC• Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC• Improvements in SKSS software deliver five times fasteruploads/downloads• Two built-in Form C programmable relays rated at 2.5 amps at 27.4VDC• Supports sounder bases• 6 amp power supply and maximum charging capacity of 35 amp hours(An additional cabinet enclosure is required for batteries in excess of 18amp hours)• Programmable date setting for Daylight Saving Time• Plex-1 door option combines a dead front cabinet door with a clearwindow,limiting access to the panel while providing single buttonoperation of the reset and silence functions InstallationThe 5820XL can be surface or flush mountedCompatibilityThe 5820XL SLC supports multiple devicetypes of the same protocol:•SK (System Sensor)•HochikiYou cannot mix Hochiki and SK devices on aFACP. EXISTING FACP RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 By: cthomas Date: 10/03/2017 FIRE DEPARTMENT For Construction Subject to Corrections Noted in Red APPROVED INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XLAddressable Fire Alarm Control Panel Indicator LightsGeneral Alarm (Red): Flashes when inalarm; solid when alarm silencedSupervisory (Yellow): Flashes when asupervisory condition exists; solid whensupervisory silencedSystem Troubles (Yellow): Flasheswhen a trouble condition exists; solidwhen trouble silencedSystem Silenced (Yellow): On when analarm, trouble or supervisory conditionhas been silenced but not yet clearedSystem Power (Green): Flashes for ACfailure; solid when power systems arenormal System Application5820XLhas one built-in signalling linecircuit (SLC) which supports multipledevices dependent on protocol beingused. Three additional loops can beadded using the 5815XL SLCexpanders to increase overall capacity.The 5820XL SLC loops supportmultiple device types, including:•Addressable photoelectric smokedetector• Addressable ionization smokedetector•Addressable heat sensor• Addressable duct smoke detector• Contact module• Relay output module• Addressable notification module•Addressable beam detector (SKprotocol only)• Addressable multi-criteria smokedetector (SK protocol only)•Addressable multi modules (SKprotocol only)The following advanced sensorcapabilities are available with 5820XL:• Automatic drift compensation•Maintenance alert• Built-in sensor test to comply withNFPA 72 calibration testingrequirements 5820XL features a 6 amp power supplyand maximum battery chargingcapacity of 35 amp hours. An additionalcabinet enclosure (PN RBB) is requiredfor batteries in excess of 18 amp hours.Flexput circuits on 5820XL control canbe individually programmed to functionas notification circuits, auxiliary poweroutputs, or initiation circuits thatsupport both 2- and 4-wire smokedetectors.The 5820XL system operates on non-twisted, unshielded cable when wiredin compliance with standard wiringpractices as called out in the NationalElectric Code 760-51 specifications forpower-limited fire protective signallingcables. No special wiring is required.5820XL provides 13 preset notificationcadence patterns (including ANSI 3.41)and four user programmable selectionsfor fire alarm notification.Two programmable general purposeForm C relay outputs are provided on5820XL.Additionally, the IntelliKnight systemfeatures a built-in walk test and auto-programming. Its innovative, dead-frontcabinet design allows for flush orsurface mounting. System maintenanceis easy to perform.User InterfaceThe 5820XL built-in annunciator with80 character LCD display and largeeasy-to-use tactile touchpad can beused for system operation,programming and maintenance. It hasfive LEDs for alarm, supervisory,system trouble, system silenced andsystem power.System operationsinclude silencing alarms and troubles,resetting alarms and the display ofalarm troubles and memory. Thesystem's non-volatile event historybuffer stores 1000 events for viewingfrom the built-in or remote annunciator.System operation can be initiated withamechanical firefighter's key or a valid4- to 7-digit operator's code.ProgrammingThe IntelliKnight system offers severaloptions to simplify and speed upprogramming. The JumpStart®featureminimizes programming required to start a new system. Thebuilt-in keypad and 5860 remoteannunciator give on-site access to allprogramming. You can also programremotely using the 5660 Silent KnightSoftware Suite, which is Windows®-based software. Built-In Digital Communicator5820XL features a built-in UL listeddigital communicator for remotereporting of system activity and systemprogramming. The communicator hasthe ability to seize two telephone linesto report alarms and troubles to amonitoring facility. The communicatorsupervises two phone lines and willactivate a trouble signal if a line failureis sustained for more than 45 seconds.Other communication features include:retry if communication fails, two phonenumber capability, download phonenumber capability and Touch-Tone orrotary dialing. The communicator iscompatible with SIA and AdemcoContact ID. The format is selectable byaccount number. ApprovalsNFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; RemoteSignalling; Local Protective SignallingSystems; Auxiliary Protected PremisesUnit; & Water Deluge ReleasingService. Suitable for automatic,manual, waterflow, sprinklersupervisory (DACT non-coded)signalling services.Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 IntelliKnight Model 5820XLAddressable Fire Alarm Control Panel INTELLIKNIGHT FIRE ALARM CONTROL PANEL RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 SpecificationsElectricalPrimary AC: 120 VRMS at 50/60 Hz, 2.5A or240 VRMS at 50/60 Hz, 1.4ATotal Accessory Load: 6A @ 27.4 VDC,power-limitedStandby Current: 215 mAAlarm Current: 385 mAFlexput Circuits:Six programmable circuits which can beprogrammed individually as:Notification circuits: 3A @ 27.4 VDCper circuit, power-limitedAuxiliary power circuits: 3A @ 27.4VDCper circuit, power-limitedInitiation Circuits: 100 mA @ 27.4VDCper circuit, power limitedPhysicalFlush Mount Dimensions:14.5”W x 24.75”H x 3.9”D(36.8 W x 62.9 H x 9.8 D cm ) Overall Dimensions:16.2”W x 26.4”H x 4.2”D(40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed incontrol panel cabinet. Larger capacitybatteries can be housed in RBBaccessory cabinet. Telephone Requirements:FCC Part 15 and Part 68 approvedType of Jack: RJ31X (two required) S-BUS Accessories5860/R Remote Fire AnnunciatorFeatures the same 80 character backlitLCD display keypad and firefighter'skeyswitch as the 5820XL. 5860 is grayand 5860R is red.5815XL Signal Line Circuit ExpanderThe SLC expander is used to add moreaddressable devices to the IntelliKnightsystem. 5820XL supports three5815XL’s. Each 5815XL can support127 devices.5895XL Intelligent Power ModuleAdds 6 amps of power, 6 Flexput I/Ocircuits and 2 Form C relay circuits to a5820XL system.5496 Intelligent Power ModuleA6amp notification power expanderthat provides four power-limited notifi-cation appliance circuit outputs.5880 LED/IO ModuleFeatures 40 LED outputs, 8 normallyopen dry contact inputs, and one piezooutput.5865-3 and 5865-4 Remote LED AnnunciatorFeatures 30 programmable LED (15red and 15 yellow) outputs, and a piezosounder. The 5865-4 adds a silenceand reset switch to the package.5883 Relay BoardFeatures 10 general purpose Form Crelays. Used with 5880 module.5824 Serial/Parallel Printer Interface ModuleProvides one parallel and one RS-232serial port for connecting a printer tothe 5820XL. Use to print a real-time logof system events, detector statusreports, and event history. Interfaceswith building control system. Miscellaneous Accessories5660 Silent Knight Software Suite(SKSS)User-friendly Windows software forremote programming of 5820XLs usingaPC. Upload and view panel accountinformation, event history, and detectorstatus.5670 Silent Knight Software Suite(SKSS)Powerful end-user facility managementsoftware allows viewing of detectorstatus and event history via modem ordirect connection.Plex-1Dead front cabinet door with clearwindow to limit access to the FACP.RBBRemote battery box accessory cabinet.Use if backup batteries are too large tofit into FACP cabinet. Dimensions:16” W x 10” H x 6” D(406 mm W x 254 mm H x 152 mm D)SD505-DTS-KRemote test switch. Used with SD505-DUCTR. Provides remote keyoperated test function and annunciationof detector alarm.Hochiki and SK DevicesSee the specification sheets listedbelow for a complete listing of theHochiki and SK devices.53624 Hochiki Devices Data Sheet53623 SK Device Protocol DevicesSpecification Sheet INTELLIKNIGHT FIRE ALARM CONTROL PANEL Made in America PN 350210 Rev G©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We try to keep our productinformation up-to-date and accurate. We cannot cover all specific applications or anticipate allrequirements. All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161, Fax: (203) 484-7118. www.silentknight.com.IntelliKnight & JumpStart are Registered Trademarks of Silent KnightFlexput is a Trademark of Silent Knight IntelliKnight Model 5820XLAddressable Fire Alarm Control Panel RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 Model SD500-PS & SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire • Extremely easy to operate • Corrosion-resistant gold-plated contacts. • Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby Current: .55mA Alarm Current: .55mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB SD500-PS and SD500-PSDA Addressable Pull-Station The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. IntelliKnight's addressable pull stations combine fast response with pin-point location ID. SD500-PS INTELLIKNIGHT ACCESSORY RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. 7550 Meridian Circle, Maple Grove, MN 55369-4927800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright © 2003 Silent Knight Wiring Dimensions Mounting to Single Gang Electrical Box Mounting to Optional Surface Mount Box Installing SD500-LK SD500-PSDA RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 Model SD505-AHS Addressable Heat Detector The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the IntelliKnight panel. If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features • Low profile, 2 inches, including base •Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol •The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. •CFSM listed •MEA listed • FM approved Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32ºF to 120ºF (0ºC to 49ºC) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70’ between sensors on smooth ceilings. Compatible Bases: SD505-6AB (Sold Separately) (6” Base) SD505-4AB (4” Base) Addressable Heat Detector IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. IntelliKnight®addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. SD505-AHS Heat Detector INTELLIKNIGHT ACCESSORY RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 INTELLIKNIGHT ACCESSORY Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Model SD505-6AB Detector Base (Front View) Model SD505-AHS Detector Head (Front View) MADE IN AMERICA FORM# 350229 Rev B,. 05/05 Copyright © 2005 Silent Knight This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 Model SD505-APSAnalog / AddressablePhotoelectric TypeSmoke DetectorThe SD505-APS is particularlysuited to detecting dense smoketypical of fires involving materialssuch as soft furnishings, plastic,foam or other similar materialswhich tend to smolder and producelarge visible particles.The detector features automaticcompensation for contaminationand a simple detector calibrationtest procedure that can be run fromthe panel or remotely (using theWindowsTMbased downloadingsoftware).OperationThe SD505-APS units made up ofan LED light source and a siliconphoto diode receiving element. In anormal standby condition, thereceiving element receives no lightfrom the pulsing light source. In theevent or fire, smoke enters thedetector and light is reflected fromthe smoke particles to the receivingelement. The light received is converted intoan electronic signal. Under normalconditions, the status LED blinksapproximately every 15 seconds,indicating that the head iscommunicating with the loop. TheLED lights continuously during thealarm period.Features•Low profile, 2 inches, includingbase•Simple and reliable addressingwithout mechanical switches•Automatic compensation forsensor contamination• Built-in fire test feature•Simple detector calibrationtesting through the control panelor remotely through aWindowsTMbased computersoftware.•Vandal-resistance lockingfeatures• Field cleanable• UL listed, meets NFPA 72 Ch 7requirements•CSFM approved• MEA approved•FM Approved SpecificationsOperating Voltage: 17-41 VDCCurrent Consumption:Standby: .55 mAAlarm: .55 mAAmbient Temperature:32ºF to 120ºF(0ºC to 49ºC)Mounting:4” Square, 4” OCT, Single gang mud ringRelative Humidity: 85% noncondensingAir Velocity: 0 - 300 FPMCompatible Bases: SD505-6AB (Sold Separately) (6” Base)SD505-4AB (4” Base) Addressable Photoelectric Type Smoke Detector IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings wheresmoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APSphotoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious secondsare wasted in determining location of an alarm.The SD505-APS compensates automatically for contamination in the environment. And detector testing issimple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile forpleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, ModelSD505-6AB, allowing complete application and placement flexibility.Combine all this with the features you’vecome to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection,and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Detect smoldering fires quickly and gethelp fast with IntelliKnight®photoelectricsmoke detectors. SD505-APS Smoke Detector INTELLIKNIGHT ACCESSORY RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 INTELLIKNIGHT ACCESSORYModel SD505-APSAddressable Photoelectric TypeSmoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detectorSilent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL®listed compatiblewith Silent Knight’s IntelliKnight fire control panels.The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505-AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB.The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, theflashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.The calibration of the detector shall be capable of being selected and measured by the control panel without theneed for external test apparatus.The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. Thelocking feature shall be field selectable as required.The SD505-APS shall automatically perform a functional test of the detector.The test method shall simulateeffects of products of combustion in the chamber to ensure testing of detector circuits. MADE IN AMERICA FORM# 350225 Rev C,. 05/05 Copyright © 2005 Silent Knight Model SD505-6AB Detector Base(front view)Model SD505-APS Detector Head(front view) This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 Model 5495Distributed Power ModuleThe 5495 is a 6 amp notification powerexpander that provides its own ACpower connection, battery chargingcircuit, and backup battery for use withfire and security controls such as theSilent Knight Model 5208 Fire Control/Communicator. The 5495 is the cost-effective solution for poweringnotification appliances required by theAmericans with Disabilities Act (ADA).The 5495 has built-in ANSI cadencepattern, which can upgrade oldercontrol panels that lack cadencecapability. Features• UL Listed for 6 amps of notificationpower• Power supply’s advanced switchmode design reduces damagingheat and manages power up to 50%more efficiently than other systems• Dip switches allow for easyreconfiguration•24 VDC filtered output voltage•Four power-limited notificationoutputs; 2 Class A or 4 Class B, or 1Class A and 2 Class B•Additional continuous auxiliaryoutput• 3 amps per output circuit• 2 inputs; 2 Class B or 2 Class A•Ground fault detector/indicator• Independent trouble relay• AC loss delay option shuts off power to non-essential high-currentaccessories like magnetic doorholders• Built-in synchronization forappliances from SystemSensor®,Gentex®,AMSECO®,Wheelock and Faraday• Stand alone operation• Lightweight design adds to ease ofinstallation and reduces shippingcosts•Operates with most polarized, ULListed notification devices• ANSI Cadence pattern outputcapability built-in Connection to Local Fire ControlThe 5495 may be connected to a localfire control which utilizes Class AorClass B type notification circuitsoperating between 9 and 32 VDC. Thecontrol panel’s notification circuit isconnected to one of the inputs on the5495. The control panel’s notificationcircuit end-of-line resistor is alsoconnected across two terminals on the5495, which provides supervisionbetween the 5495 and the fire controlpanel. Polarized audible and/or visualnotification devices are then connectedto the 5495 signal circuits using the4.7k end-of-line resistors provided.Since the 5495 draws very little powerfrom the control, it is possible toconnect one 5495 to each notificationcircuit on the control panel and stillprovide full supervision of thenotification circuits all the way back tothe control panel. Approvals•UL Listed•MEA 429-92-E Vol XII• CSFM 7300-0559:123•NFPA72 Model 5495Distributed Power Module The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supplyavailable today. It delivers 6 amps of notification appliance circuit power and built-in synchronization forappliances from System Sensor®,Gentex®,AMSECO®,Wheelock and Faraday — what you need to drive power-hungry components like ADA notification appliances. The 5495’s advanced microprocessor design is yearsahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitivelinear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because itintegrates into current systems without the costly investment in new components.For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call SilentKnight today for more information at 1-800-328-0103. In an emergency,you need maximum power FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 FIRE SYSTEM ACCESSORY Model 5495Distributed Power Module SupervisionThe 5495 supervises a variety offunctions including:• Low AC power• Low battery condition• Earth ground fault• Auxiliary output power limitcondition• EOL supervision trouble orpower limited condition at anoutputWhen a trouble condition occurs,the 5495 creates a troublecondition on the host control signalcircuitsto which it is connected. the5495 still maintains the ability to beactivated by the host control. Inaddition, the 5495 provides a FormCtrouble relay output as analternative to using the notificationcircuit trouble.Electrical SpecificationAC input: 120 VAC at 2 ampsOutput: 24 VDC at 6 amps Current:Standby 75 mAAlarm 205 mAAuxiliarypower circuit: 1Notificationcircuits: 4Outputconfiguration:2 Class A (Style Z)4 Class B (Style Y)(1 Class A & 2 Class B)Amps peroutput circuit: 3.0 (6.0 amps total)Notificationcircuit output:20.4 to 27.3 VDC @ 3.0 amps each,4.7 k EOLresistor requiredon each Class BcircuitNo. of inputs 2Inputconfiguration:2 Class B or 2 Class A Inputvoltage range: 9 - 32 VDCBattery chargingcapacity: 35.0 AHAmbient temp.: 32° to 120° F(0° to 49° C)MechanicalDimensions: 12.25” W x 16” H x3” D (30.88 cm Wx40.64 cm H x7.62 D cm)Indicator LightsAC power on :GreenBattery trouble: YellowGround fault:YellowAux trouble:YellowOutput troubles (1-4): YellowOrdering Information5495 Distributed Power Module MADE IN AMERICA FORM# 350395 Rev D©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 AVDS86800 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11⁄16 × 4 11⁄16 × 2 1⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 AVDS86800 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 UL Current Draw Data Horn Strobe Tones and Sound Output Data RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86801 • 03/17 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box RECEIVED 09/25/2017 striplett BUILDING DIVISION F17004475