Loading...
HomeMy WebLinkAboutSWP2701272.13NOTE: FIRST NUMBER OF CODE REFERS TO THE SHEET NUMBER, OF THE CONTRACT PLANS. THE SECOND NUMBER REFERS f TO THE STRUCTURE ITEM ON THAT PARTICULAR SHEET. 3 � t CODE LOCATION INSTRUCTION 3-1 STA 15+00 LOGAN RT 6.0 SEE CONSTRUCTION NOTE I. CONNECT vTO MANHOLE 3-2 WITH 108.0 OF 24 CONCRETE PIPE. (MANHOLE 72-4) 3-2 STA 16+08.1 LOGAN RT 6.0 �- SEE CONSTRUCTION NOTE 1. CONNECT TO MANHOLE 3-3 WITH 321.0' OF 24' CONCRETE PIPE. (MANHOLE .72-4) 3-3 STA 19+29.0 LOGAN RT 6.0' --�-- SEE CONSTRUCTION NOTE I. CONNECT TO � START OF PROJECT WITH 304' OF 24" CONCRETE PIPE. (MANHOLE 72-4) 3-4 STA 12+70 LOGAN RT 22.0' SEE CONSTRUCTION NOTE 3. CONNECT TO W PIPE AT 12+70, LT 6.0' WITH 14 OF 6' CONCRETE PIPE. STUB OUT TO P/L. 3-5 STA 12+70 LOGAN LT 22.0SEE CONSTRUCTION NOTE 3. CONNECT TO 24 PIPE AT 12+70, LT 6.0 WITH 26 OF 6 CONCRETE PIPE. STUB OUT TO P/L. 1 3-6 STA 16+08.1 AHD LOGAN LT 22 0' SEE CONSTRUCTION NOTE 3. CONNECT TO MANHOLE 3-2 WITH 26 OF 6 CONCRETE PIPE. STUB OUT TO P/L. 3-7 STA 16+08.1 BK LOGAN RT 22 0' SEE CONSTRUCTION NOTE 3. CONNECT TO MANHOLE 3-2 WITH 14' OF 6" CONCRETE PIPE. STUB OUT TO P/L. 3-8 STA 18+80 LOGAN LT 22.0 I SEE CONSTRUCTION NOTES 3 8 4. CONNECT TO EXISTING DRAIN LINE AT 18+80, LT 18.0 WITH 3 OF 67 CONCRETE PIPE. 3-9 STA 18+80 LOGAN RT 22.0'~ SEE CONSTRUCTION NOTES 3 81 4. CONNECT TO EXISTING _DRAIN LINE AT 18+80, RT 18.0' WITH 3' OF 6" CONCRETE PIPE. i 3 -10 STA 19+31 LOGAN RT 33.0' SEE CONSTRUCTION NOTES 3 8 4. CONNECT T0_ EXISTING DRAIN LINE AT 19+2% RT 33.0' WITH 3' OF 6" CONCRETE PIPE. '- - -- ' - SEE CONSTRUCTION NOTE 3. CONNECT TO 24' PIPE AT 20+44, RT 6.0 WITH 26' OF 6" CONCRETE PIPE. STUB OUT TO P/L. } 3-1 I STA 20+44 LOGAN LT 22.0 3-12 STA 20+44 LOGAN RT 22 0' -� SEE CONSTRUCTION NOTE 3, CONNECT TO 24" PIPE AT 20+44, RT 6.0' WITH 14 OF 6 CONCRETE PIPE. STUB OUT TO P/L. 3-13 STA 19+23.2 LOGAN LT 61 0 TO CONNECT EXISTING MANHOLE AT 19+23.2, LT 16.0 TO MANHOLE 3-3 WITH 23` OF 12 CONCRETE PIPE. PLUG EXISTING 12 DRAIN LINE NORTH AT EXISTING MANHOLE, STA 19+29 LOGAN RT 6.0' 3-14 STA 13+80 LOGAN LT STUB OUT 24 FOFO 6 CONCRETE PIPE TO P/ L FROM 24 PIPE AT 13+80, LT 6.0' PLUG END OF PIPE. 3-15 STA 13+80 LOGAN RT STUB OUT 36 OF 65'y CONCRETE PIPE TO P/L FROM 24 PIPE AT 13+801 LT 6.0. PLUG END OF PIPE. 3-16 STA 17+60.7 LOGAN RT I STUB OUT 24 OF 6 CONCRETE PIPE TO P/L FROM 2- 4 PIPE AT 17+60.7, RT 6.0. PLUG END OF PIPE. 3-17 STA 17+83.2 LOGAN LT STUB OUT 36 OF 6 CONCRETE PIPE TO P/L FROM 24 PIPE AT 17+83.2, RT 6.0. PLUG END OF PIPE. 3-18 STA 7+84 TOBIN RT 18.0 SEE CONSTRUCTION NOTES 384. CONNECT TO EXISTING DRAIN LINE AT 7+84 TOBIN, RT 17.0' WITH 3 OF 6 CONCRETE PIPE. 3-19 STA 7+91 TOBIN LT 210 - SEE CONSTRUCTION NOTES 384. CONNECT TO EXISTING DRAIN LINE AT 7+91 TOBIN LT 13.d WITH 3' OF 6" CONCRETE PIPE. 3-204 STA 10+39 LOGAN RT 22.0' SEE CONSTRUCTION NOTE 3. CONNECT TO 24 PIPE AT 10+39, LT 6.0 WITH 26 OF 6 CONCRETE PIPE. _ 4-1 I STA 20417.5 S 2nd RT 15.0' 4-2 STA 23+34.5 S 2nd �RT 15.0- 4-3 STA 26+55.0 S 2nd RT 15.0 4-4 STA 29+46.8 S 2nd RT 15.0' 4-5 STA 9+67 LOGAN RT 22.0' 4-6 STA 10+34 BURNETT RT 18.0' 4-7 STA 23+71 S 2nd LT 32.0' 4-8 STA 23+73- S 2nd RT 21.0' 4-9 STA 24+88.5 S 2nd RT 34.0 - 4-10 STA 9+66 WILLIAMS LT 21.0 4-II STA 9+66 WILLIAMS RT 21.0--.- 4-12 STA 26+74 S 2nd RT 20.0' - 4 -13 STA 27+90 S 2nd RT 35.0 5-1 } STA 4+50 BURNETT LT 5-2 STA 4+78.5 BURNETT LT 54.0' 5-3 STA 4 +80 BURNETT RT 22.0' 5-4 STA 9+64.5 BURNETT LT 69.0 5-5 STA 9+64 BURNETT RT 22.0' CONSTRUCTION NOTES NOTE I. CONSTRUCT MANHOLE AS PER DETAIL SPECIFIED. SEE STANDARD PLANS. NOTE 2. REMOVE EXISTING MANHOLE. REMOVAL TO BE INCIDENTAL TO CONSTRUCTION. NOTE 3. CONSTRUCT TYPE I CATCH BASIN. IN SOME LOCATIONS A TYPE I-C MAY BE REQUIRED. NOTE 4. REMOVE EXISTING CURB INLET. REMOVAL TO BE INCIDENTAL TO CONSTRUCTION. NOTE 5. REMOVE EXISTING CATCH BASIN. REMOVAL TO BE INCIDENTAL TO CONSTRUCTION. CONSTRUCT SPECIAL 6 Di,4METER MANHOLE CONNECT TO MANHOLE 3-1 WITH 515' OF 24 CONCRETE PIPE. (MAN.HOLE 72-5, CHANNEL DETAIL 72-7) SEE CONSTRUCTION NOTE I. CONNECT TO MANHOLE 4-1 WITH 317 OF 2I' CONCRETE PIPE. (MANHOLE 72-3) SEE CONSTRUCTION NOTES _I82. CONNECT TO MANHOLE 4-2 WITH 32I OF 18 CONCRETE PIPE. MANHOLE TO BE CONSTRUCTED OVER EXISTING 8' DRAIN LINE. CONNECT DRAIN .LINE SOUTH TO THIS MANHOLE. PLUG DRAIN LINE NORTH T THIS MANHOLE. (MANHOLE 72-3) SEE CONSTRUCTION NOTE 1. CONNECT TO MANHOLE 4-3 WITH 292 OF 5' ONCRETE PIPE. STUB OUT TO EAST WITH 12 CONCRETE PIPE. (MANHOLE 72-3) SEE CONSTRUCTION NOTE 3. CONNECT TO MANHOLE 4-1 WITH 33' OF 6 CONCRETE PIPE. STUB OUT TO P/L. SEE CONSTRUCTION NOTES 3 84. CONNECT TO EXISTING 8" DRAIN LINE AT 10+34 BURNETT, RT 14.0' WITH 8' OF 6" CONCRETE PIPE. -~ CONNECT EXISTING CATCH BASIN TO CATCH BASIN 4-6 WITH 14 OF 6 CONCRETE PIPE. STUB OUT TO EAST WITH 6' CONCRETE PIPE. SEE CONSTRUCTION NOTE 4. SEE CONSTRUCTION NOTES 384. CONNECT TO 18 PIPE AT 24+88.5, RT 15.0 WITH 18' 6F'6" CONCRETE PIPE. SEE CONSTRUCTION NOTES 384. CONNECT TO CATCH BASIN 4-11 WITH 40 OF 6 CONCRETE PIPE. SEE CONSTRUCTION NOTES 384. CONNECT TO MANHOLE 4-3 WITH 19 OF 6 CONCRETE PIPE. SEE CONSTRUCTION NOTE 4. SEE CONSTRUCTION NOTES 384. CONNECT TO 15 PIPE AT 27+90, RT 15.0 WITH 20 OF 6 CONCRETE PIPE. CONCRETE PIPE` CONNECT- EXISTING STORM LINE EAST TO THIS MANHOLE. (MANHOLE 72-3) SEE CONSTRUCTION NOTE 1. CONNECT TO MANHOLE 4-2 WITH 535 OF 12" PLUG EXISTING STORM LINE WEST AT THIS MANHOLE. PIPE. SEE CONSTRUCTION NOTE 3. CONNECTS MANHOLE 5-1 WITH 54' OF 6" CONCRETE SEE CONSTRUCTION NOTE 3. CONNECT TO MANHOLE 5-1 WITH 41' OF 6" CONCRETE PIPE. INSTALL SPECIAL SIDEWALK LID. SEE CONSTRUCTION NOTE 3. CONNECT TO 21" PIPE AT 22 +78.5 S 2nd ST, RT 15.0' WITH 201 OF 6" CONCRETE PIPE. STUB OUT TO P/L SEE CONSTRUCTION NOTES 3+4. CONNECT TO MANHOLE 4-2 WITH 35' OF 6" CONCRETE PIPE. INSTALL SPECIAL SIDEWALK LID. CITY OF RENTON ENGINEERING DEPARTMENT DEsts > DATE FILE NO. DRAW CHECKED SCALE FIELD 000K "AG'F - REVISION 111 �APPR. DATE APPROVED g CITY ENGINEER .._ J r a /.�,td -�ti prCT YRic4M lOd3 '. r�Et iTAli i^-', iXaC,i .:.2-Gk.•