HomeMy WebLinkAboutTRO4101438.2-14
SIGNAL PHASING DIAGRAM
CONSTRUCTION NOTES
- 21+a4 0 2+ 5 t 4+7
REMOVE THREE EXISTING VEHICLE SIGNAL HEADS AND ONE
EXISTING PEDESTRIAN SIGNAL HEAD FROM EXISTING SIG-
:�'hi_ INSTALL THREE VEHICLE SIGNAL HEADS;
ONE PEDESTRIAN SIGNAL HEAD; D3-3 "WEST VALLEY HWY."
SIGN, RECONNECT EXISTING SIGNAL WIRING,#
�2 INSTH'-L SIGNAL POLE AT APPROX. STA, 100 + 55, 40'
RT.; THREE VEHICLE SIGNAL HEADS; 400 W U.S. LUMI-
NAIRE; ONE PEDESTRIAN SIGNAL HEAD; ONE PEDESTRIAN
PUSHBUTTON; TWO ONE -DIRECTION PREEMPTION DETECTORS;
D3-3 "WEST VALLEY HWY." SIGN.*
O3 REMOVE THREE EXISTING VEHICLE SIGNAL HEADS FROM
EXISTING SIGNAL POLE, INSTALL THREE VEHICLE SIGNAL
HEADS; D3-3 "S.W. 43RD ST. (S, 180TH ST,)" SIGN,
RECONNECT EXISTING SIGNAL WIRING,*
4o REMOVE THREE EXISTING VEHICLE SIGNAL HEADS FROM
EXISTING SIGNAL POLE, INSTALL THREE VEHICLE SIGNAL
HEADS; TWO ONE -DIRECTION PREEMPTION DETECTORS; D3-3
"S, 180TH ST, (S.W. 43RD ST,)" SIGN.# RECONNECT
EXISTING SIGNAL WIRING.
OREMOVE EXISTING TRAFFIC SIGNAL POLE, CEMENT CONCRETE
FOUNDATION, CONDUIT AND WIRING,
INSTALL PEDESTRIAN SIGNAL POLE AT APPROX. STA. 100 +
46, 44' LT,; TWO PEDESTRIAN SIGNAL HEADS; TWO PEDEST-
RIAN PUSHBUTTONS,*
OREMOVE EXISTING PEDESTRIAN SIGNAL POLE,
CEMENT CONCRETE FOUNDATION, CONDUIT AND WIRING,
OINSTALL TYPE M FOUNDATION AND TRAFFIC SIGNAL
CONTROLLER CABINET AT APPROX. STA, 100 + 36,
60' LT, USE WSDOT STANDARD PLAN J-6c.
OREMOVE EXISTING TRAFFIC SIGNAL CONTROLLER
CABINET, CEMENT CONCRETE FOUNDATION, CONDUIT
AND WIRING,
10 INSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET
AT APPROX. STA, 100 + 41, 54' LT. USE DETAIL H.
II INSTALL INTERMEDIATE DESIGN JUNCTION BOXES AT
APPROX. LOCATIONS SHOWN. USE DETAIL A.
12 INSTALL DESIGN "B" JUNCTION BOXES AT APPROX.
LOCATIONS SHOWN, USE WSDOT STANDARD PLAN J-11,
13 REMOVE EXISTING JUNCTION BOX, INSTALL DESIGN 'T
JUNCTION BOX AT SAME LOCATION,
14 REMOVE EXISTING JUNCTION BOXES, CONDUIT AND WIRING,
15 INSTALL 6' X 6' (3 TURN) INDUCTION LOOP VEHICLE
DETECTORS AT THE LOCATIONS SHOWN, USE DETAILS E & F.
*FOR SIGNAL POLES, USE DETAILS B, C AND D
AND THE FOLLOWING WSDOT STANDARD PLANS:
J-6 (TYPE B & C MOUNTINGS, PEDESTRIAN
SIGNAL POLE,)
J-6A (BACKPLATE AND TUNNEL VISOR)
J-6B (TYPE L & M MOUNTINGS)
J-S (SIGNAL POLE FOUNDATION)
GREEN RIVER
R/W
01+5
2 S.W. 43RD ST.
rI
0 2+6 03+7
SIGNAL FACE SCHEDULE
HEAD MOUNTING TYPES AS SHOWN
DONT
WALK
HEADS 21,28 (TYPE B)
HEADS 22,27 (TYPE C)
12
R 12li R 12
Y 12 If 612
G 1211 G 12 11
HEADS 1,2,5,6,7,8
( T'(PE M)
HEADS 3,4
TYPE L) ONLY
HEADS 9,1 I, 12
(TYPE M)
HEAD 10
( TYPE L )
(S. 180TH ST.)
ri
0 4+88
r
,7
WIRING SCHEDULE --- J a
� PAAT�H �
" 224-1"65 2► 22 2 5 12 i (n
i 4 (TWISTED PAIRS) SAWCUT, ICONDUIT II 6C SHIELDED 4 SCH. 40 PVC CONDUIT 37
4-IC # " 1-
1 6 _ " ti
2C 414 SHIELDED 2 SCH, 40 PVC CONDUIT (SPARE) E / \ LEGEND
D
A
P ) S 13K" CONDUIT 3-5C 2-3C (PREEMPTION) �" / \ RAW
12
2
16-IC
#14
(TWISTED AIRS
AWCUT,
,
/ \ EXISTING
PROPOSED
3
1--2C
#14
SHIELDED
CH
1" S.
4Q
ONDU
PVC CONDUIT
L12 �
6-1c
#8, 1-1c #10 BARE 2 " SCH, 40 PVC CONDUIT
\� 12 VEHICLE SIGNAL HEAD
�►
o_
A1-2c
#14
SHIELDED
EXISTING
1"
CONDUIT
13
CONDUCTORS
PER PUGET SOUND 1" SCH, 40 PVC CONDUIT
PEDESTRIAN SIGNAL HEAD-�
39 225
(EXTEND
TO
JUNCTION BOX)
POWER
& LIGHT CO, REQUIRE-
PREEMPTION DETECTOR
MENTS
o_ TRAFFIC SIGNAL CONTROLLER CABINET
A
1-2C
#14
SHIELDED
2" SCH.
80
PVC CONDUIT
DESIGN 'B' CONCRETE JUNCTION BOX
A640PVC
1-2C
#14
SHIELDED
1 "SCH,
CONDUIT
Q2-1C
14
#6 (SERVICE)
#10 BARE h" SCH, 40 PVC CONDUIT
40
1 INTERMEDIATE DESIGN CONCRETE JJNCTION
BOX
-1C
'C'
1-6c
SHIELDED
h" SCH,
40
PVC CONDUIT
222 DESIGN CONCRETE JUNCTON BOX
23
��
UNDERGROUND CONDUIT
---
4-1C
#E, 1-1c #1J BARE
Z6EXISTING CABLES: EXISTING 2-� CONDUIT
5-5c, 1-8c t 22�
PAVEMENT ARROW
0
1 -6c
SHIELDED
1'"
SCH ,
40
PVC
CONDUIT
_
I
INDUCTION LOOP VEHICLE DETECTOR
4-1C
#8, 1-iC #10 BARE
1'2"
SCH ,
4O
PVC
CONDUIT
1-6C SHIELDED 2-4" SCH, 40 PVC CONDUIT I
16
9-2C #14 SHIELDED 2 'r SCH. 40 PVC CONDUIT (SPARE) �
I
MAGNETOMETER VEHICLE DETECTOR
8
2-1C
#S, 1-1C 910 BARE
2�"
SCH,
40
PVC
CONDUIT
-5C, 4-3C (PREEMPTION) I
UNDERGROUND ELECTRICAL VAULT
3-5c
2-3c (PREEMPTION)
2
SCH,
40
PVC
CONDUIT (SPARE)
2-iC #6 (SERVICE)
ELECTRICAL SERVICE CABINET
Aq
2-lc
#�, 1-lc #10 BARE
3 "
SCH,
80
PVC
CONDUIT
1-lc #10 BARE
4CC W H.PS. LUMINAIRE
-`
3 �'C
#14 SHIELDED
2 "
SCH,
80
PVC
CONDUIT (SPARE)
EXISTING CABLES: •3 a �
TI-;AFF� IC MOVEMENT IDENTIFICATION
3-5C,
2-3C (PREEMPTION)
7-5c, 1-8C � 3
_ " PVC CONDUIT A 2-3C (PREEMPTION) EXISTING lk" CONDUIT
A �-5C, 1 1C #10 BARE 2 SCH, 40 ,
EXISTING CABLES- 2-5C (EXTEND TO JUNCTION BOX)
•�i;a' /S'yp11t
.'Of yam. A
��.
STA. ON C�ST 'Li'.
BATCH �� ���� �,��^ 2 7 ��pc TRANSPORTATION PLANNING & ENGINEERING, INC. �%%\�/ONAI E`'
1126 - 108TH AVE. N.E. BELLE VUE, WASHINGTON 98004 Ph4206) 455-5320
O N
a M
--
u
f
N
1
C
WT.
Q
�j
s
00
wa,
ono L c
0
..
v
Q b
n' N
b
j
-- >
o u
00
7.
J— C_-
z
0
Cz
z
x
a
3
y
Z
�
W
W
W
J
Wx
and
O
o
a
Z
Uj
Q
�t
...1
W
CL
co
W
o~
co W
~
O
looCO3
_
Co
C2
v
�
M
W
Emma
�
Q
y
W
oal�
c
0
v
Date 2 /10/81
Scale I'
= 20
Designed
DH E
Drawn
R FM
Checked
DHE
Approved
VHB
Dwg. Number
SHEET
of
r