Loading...
HomeMy WebLinkAboutTRO4101438.2-14 SIGNAL PHASING DIAGRAM CONSTRUCTION NOTES - 21+a4 0 2+ 5 t 4+7 REMOVE THREE EXISTING VEHICLE SIGNAL HEADS AND ONE EXISTING PEDESTRIAN SIGNAL HEAD FROM EXISTING SIG- :�'hi_ INSTALL THREE VEHICLE SIGNAL HEADS; ONE PEDESTRIAN SIGNAL HEAD; D3-3 "WEST VALLEY HWY." SIGN, RECONNECT EXISTING SIGNAL WIRING,# �2 INSTH'-L SIGNAL POLE AT APPROX. STA, 100 + 55, 40' RT.; THREE VEHICLE SIGNAL HEADS; 400 W U.S. LUMI- NAIRE; ONE PEDESTRIAN SIGNAL HEAD; ONE PEDESTRIAN PUSHBUTTON; TWO ONE -DIRECTION PREEMPTION DETECTORS; D3-3 "WEST VALLEY HWY." SIGN.* O3 REMOVE THREE EXISTING VEHICLE SIGNAL HEADS FROM EXISTING SIGNAL POLE, INSTALL THREE VEHICLE SIGNAL HEADS; D3-3 "S.W. 43RD ST. (S, 180TH ST,)" SIGN, RECONNECT EXISTING SIGNAL WIRING,* 4o REMOVE THREE EXISTING VEHICLE SIGNAL HEADS FROM EXISTING SIGNAL POLE, INSTALL THREE VEHICLE SIGNAL HEADS; TWO ONE -DIRECTION PREEMPTION DETECTORS; D3-3 "S, 180TH ST, (S.W. 43RD ST,)" SIGN.# RECONNECT EXISTING SIGNAL WIRING. OREMOVE EXISTING TRAFFIC SIGNAL POLE, CEMENT CONCRETE FOUNDATION, CONDUIT AND WIRING, INSTALL PEDESTRIAN SIGNAL POLE AT APPROX. STA. 100 + 46, 44' LT,; TWO PEDESTRIAN SIGNAL HEADS; TWO PEDEST- RIAN PUSHBUTTONS,* OREMOVE EXISTING PEDESTRIAN SIGNAL POLE, CEMENT CONCRETE FOUNDATION, CONDUIT AND WIRING, OINSTALL TYPE M FOUNDATION AND TRAFFIC SIGNAL CONTROLLER CABINET AT APPROX. STA, 100 + 36, 60' LT, USE WSDOT STANDARD PLAN J-6c. OREMOVE EXISTING TRAFFIC SIGNAL CONTROLLER CABINET, CEMENT CONCRETE FOUNDATION, CONDUIT AND WIRING, 10 INSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET AT APPROX. STA, 100 + 41, 54' LT. USE DETAIL H. II INSTALL INTERMEDIATE DESIGN JUNCTION BOXES AT APPROX. LOCATIONS SHOWN. USE DETAIL A. 12 INSTALL DESIGN "B" JUNCTION BOXES AT APPROX. LOCATIONS SHOWN, USE WSDOT STANDARD PLAN J-11, 13 REMOVE EXISTING JUNCTION BOX, INSTALL DESIGN 'T JUNCTION BOX AT SAME LOCATION, 14 REMOVE EXISTING JUNCTION BOXES, CONDUIT AND WIRING, 15 INSTALL 6' X 6' (3 TURN) INDUCTION LOOP VEHICLE DETECTORS AT THE LOCATIONS SHOWN, USE DETAILS E & F. *FOR SIGNAL POLES, USE DETAILS B, C AND D AND THE FOLLOWING WSDOT STANDARD PLANS: J-6 (TYPE B & C MOUNTINGS, PEDESTRIAN SIGNAL POLE,) J-6A (BACKPLATE AND TUNNEL VISOR) J-6B (TYPE L & M MOUNTINGS) J-S (SIGNAL POLE FOUNDATION) GREEN RIVER R/W 01+5 2 S.W. 43RD ST. rI 0 2+6 03+7 SIGNAL FACE SCHEDULE HEAD MOUNTING TYPES AS SHOWN DONT WALK HEADS 21,28 (TYPE B) HEADS 22,27 (TYPE C) 12 R 12li R 12 Y 12 If 612 G 1211 G 12 11 HEADS 1,2,5,6,7,8 ( T'(PE M) HEADS 3,4 TYPE L) ONLY HEADS 9,1 I, 12 (TYPE M) HEAD 10 ( TYPE L ) (S. 180TH ST.) ri 0 4+88 r ,7 WIRING SCHEDULE --- J a � PAAT�H � " 224-1"65 2► 22 2 5 12 i (n i 4 (TWISTED PAIRS) SAWCUT, ICONDUIT II 6C SHIELDED 4 SCH. 40 PVC CONDUIT 37 4-IC # " 1- 1 6 _ " ti 2C 414 SHIELDED 2 SCH, 40 PVC CONDUIT (SPARE) E / \ LEGEND D A P ) S 13K" CONDUIT 3-5C 2-3C (PREEMPTION) �" / \ RAW 12 2 16-IC #14 (TWISTED AIRS AWCUT, , / \ EXISTING PROPOSED 3 1--2C #14 SHIELDED CH 1" S. 4Q ONDU PVC CONDUIT L12 � 6-1c #8, 1-1c #10 BARE 2 " SCH, 40 PVC CONDUIT \� 12 VEHICLE SIGNAL HEAD �► o_ A1-2c #14 SHIELDED EXISTING 1" CONDUIT 13 CONDUCTORS PER PUGET SOUND 1" SCH, 40 PVC CONDUIT PEDESTRIAN SIGNAL HEAD-� 39 225 (EXTEND TO JUNCTION BOX) POWER & LIGHT CO, REQUIRE- PREEMPTION DETECTOR MENTS o_ TRAFFIC SIGNAL CONTROLLER CABINET A 1-2C #14 SHIELDED 2" SCH. 80 PVC CONDUIT DESIGN 'B' CONCRETE JUNCTION BOX A640PVC 1-2C #14 SHIELDED 1 "SCH, CONDUIT Q2-1C 14 #6 (SERVICE) #10 BARE h" SCH, 40 PVC CONDUIT 40 1 INTERMEDIATE DESIGN CONCRETE JJNCTION BOX -1C 'C' 1-6c SHIELDED h" SCH, 40 PVC CONDUIT 222 DESIGN CONCRETE JUNCTON BOX 23 �� UNDERGROUND CONDUIT --- 4-1C #E, 1-1c #1J BARE Z6EXISTING CABLES: EXISTING 2-� CONDUIT 5-5c, 1-8c t 22� PAVEMENT ARROW 0 1 -6c SHIELDED 1'" SCH , 40 PVC CONDUIT _ I INDUCTION LOOP VEHICLE DETECTOR 4-1C #8, 1-iC #10 BARE 1'2" SCH , 4O PVC CONDUIT 1-6C SHIELDED 2-4" SCH, 40 PVC CONDUIT I 16 9-2C #14 SHIELDED 2 'r SCH. 40 PVC CONDUIT (SPARE) � I MAGNETOMETER VEHICLE DETECTOR 8 2-1C #S, 1-1C 910 BARE 2�" SCH, 40 PVC CONDUIT -5C, 4-3C (PREEMPTION) I UNDERGROUND ELECTRICAL VAULT 3-5c 2-3c (PREEMPTION) 2 SCH, 40 PVC CONDUIT (SPARE) 2-iC #6 (SERVICE) ELECTRICAL SERVICE CABINET Aq 2-lc #�, 1-lc #10 BARE 3 " SCH, 80 PVC CONDUIT 1-lc #10 BARE 4CC W H.PS. LUMINAIRE -` 3 �'C #14 SHIELDED 2 " SCH, 80 PVC CONDUIT (SPARE) EXISTING CABLES: •3 a � TI-;AFF� IC MOVEMENT IDENTIFICATION 3-5C, 2-3C (PREEMPTION) 7-5c, 1-8C � 3 _ " PVC CONDUIT A 2-3C (PREEMPTION) EXISTING lk" CONDUIT A �-5C, 1 1C #10 BARE 2 SCH, 40 , EXISTING CABLES- 2-5C (EXTEND TO JUNCTION BOX) •�i;a' /S'yp11t .'Of yam. A ��. STA. ON C�ST 'Li'. BATCH �� ���� �,��^ 2 7 ��pc TRANSPORTATION PLANNING & ENGINEERING, INC. �%%\�/ONAI E`' 1126 - 108TH AVE. N.E. BELLE VUE, WASHINGTON 98004 Ph4206) 455-5320 O N a M -- u f N 1 C WT. Q �j s 00 wa, ono L c 0 .. v Q b n' N b j -- > o u 00 7. J— C_- z 0 Cz z x a 3 y Z � W W W J Wx and O o a Z Uj Q �t ...1 W CL co W o~ co W ~ O looCO3 _ Co C2 v � M W Emma � Q y W oal� c 0 v Date 2 /10/81 Scale I' = 20 Designed DH E Drawn R FM Checked DHE Approved VHB Dwg. Number SHEET of r