9+54.80 /
STA 6+87
i i+oo S. 4th. ST.
SERVICE POINT #1 - 120/240 VOLT SERVICE FOR ILLUMINATION CIRCUITS.
TOTAL APPROXIMATE RATED LOAD.
ILLUMINATION = 90 AMPS
SCALE IN FEET
CONSTRUCTION NOTES
12+00
INSTALL 400 WATT SODIUM VAPOR LUMINAIRE WITH PHOTOELECTRIC
CELL. SEE SPECIAL PROVISIONS.
CONSTRUCT FOUNDATION AND PROVIDE AND INSTALL MASTER CONTACTOR
WITH MODIFIED TYPE D SERVICE IN TYPE A CABINET 3' FROM THE FACE
OF CURB. SEE SPECIAL PROVISIONS, DETAIL SHEET, AND STANDARD
PLANS J-18c, J-18d AND J-18e.
3 WIRE AND CONDUIT FROM PUGET POWER VAULT TO MASTER CONTACTOR
TO BE FURNISHED AND INSTALLED BY PUGET POWER.