Loading...
HomeMy WebLinkAboutTED4001825.20Z 0 Q Iu- ,Z w 0 Y Q 0'� J Z ; cr Lu > �!C 10 a v EX" (13 IN BO PR FERGUSON A. SONS ANC + 'Oc Azz 13 !3 - .......... I ........... ..'W U 2 Iq EN CONDUIT & WIRING SCHEDULE RUN PVC CONDUIT NO. DIAMETER SCHEDULE CONDUCTORS 1 EXISTING 40 (8-5/C), (3-5/C, 4-3/C SHLD., 3-6 PR, 3", 3", 2" NEW 1-6 PR), (8-2/C SHLD., 248) A EXISTING .80 (2-5/C, 1-3/C SHLD., 2-2/C SHLD.), 3", 3", 2" (248), (New 1-6 PR) A3 2", 2" 40 (1-2/C SHLD., 1-6 PR), (248) A4 2" 2" 80 (1 - 6 PR), (2-#8) 0 11/2" 80 (248, 148G) © 11/2" 80 (248) A7 2" 80 (4412) ® 2" 80 (1-6 PR) Ag 1 3", 3", 2" 80 (PULL WIRE) PULL WIRE), (1-2/C SHLD.) �0\ 2" 40 (1-2/C SHLD.) 0 3", 3" 80 (PULL WIRE) FOR TELEMETRY, (PULL WIRE) FOR COMMUNICATION 0 11/2 40 (248) 3/4„ _ (2412, 1412G) LIQUIDTIGHT FLEXIBLE CONDUIT E 2" 40 (PULL WIRE) FOR TELEMETRY 2%2" 80 (1-6PR),(2-#811-#8G) 16\ ill 40 (2412, 1412G) N07ES 1, ALL LIGHT STANDAgDS WITH JUNCTION BOXES, AND STAND ALONE JUNCTION BOXES EXCEPT THOSE WITHIN THE STREET PAVEMENT SHALL HAVE CONCRETE DADS PEK T�ENTON STANDARD CAE?AIL 4 -S. 2. 714E LOCATION OF CONDUIT IN THE CONDUIT TRENCH IS SCHEMATIC. SEE 714E UNDERORA/N SYSTEM SHEETS F01z CONDUIT POSITIONS IN 714E Tl2 ENCH . 3. SEE CITY OF RENTON STANDARD DRAWINGS FOP, ADDITIONAL CHANNELIZAT/ON A/VO SIGNAL DETAILS. 4. CONDUIT WITHIN LIMITS OF UNDERO/ FAIN SYSTEM SHALL BE PLACED A500/ THE 6EOTEXTILE FAERIC AND COVERED WITH GKAVEL 8ACKFILL FOR DRAIN. S. CONDUIT OUTSIDE THE UNDERORAI&I SYSTEM SHALL 8E LAID TO A MINIMUM DEPTH OF 18 INCHES 5ELOW THE F/NISH GRADE . TO MATCH-( AT CL1/w,5 �— GL)T TER FLOW LINE-, O 20 40 Coo F (= ET Q n /2o' EXISTING STIQII�::'ING TO /eE"AIN 5Top �5A/� 0 /-AINTEO 5' wlC)E SOLID STIeIPE, 1NHITE 2-4 " LANE LINE MAIeKEreS, TYRE 1, WHITE C3'0. C FT TURN APPROACH LINE TAIL rf Ls ATTACHMENT O CHANGE ORDER NO. 6 v ; AS BUILT PROJECT NO. SEA21810.K2 4,r&y� FCtSjEQ .¢4 RECORD DRAWINGS DECEMBER 23, 1988 Revisions Drawn by M G PARc �AIQ Data 6 x THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON] THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION, X-1 TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE r RECORD DRAWINGS. ®!S><` RECORD DRA WINO, MCrS CHANCED 57R/P/NG WIDTH GOG ', K5N' 12-21-88 CWUHI LL SCHEDULE A CITY OF RENTON D E P A R T M E N T O F P U B L. k W 0 R K S A LILIM 17A'rl^Ll 1 1/%IJT1L1^ A !' I^Ll A l A SCANNED MAR 18 2003 - - Z-