Loading...
HomeMy WebLinkAboutSWP3002042.9NOTE: EXTREME CARE SHALL, BE USED WHEN WORKING IN THE VICINITY OF OR CROSSING THE EXISTING WATER MAINS TO MAINTAIN FIRE PROTECTION AND DOMESTIC WATER SERVICE UNTIL THE. NEW SYSTEMS ARE OPERABLE. REMOVE HYDRANT H8, REMOVE HYDRANT H10, REMOVE HYDRANT Hill VALVES & POSTS VALVES & POSTS VALVES & POSTS PER SHEET C20___...._., PER SHEET C20 PER SHEET C20 .......... . ........ . ........ ...... . . . ...... . ... . .. . . . .. ... L4 4 I L R" TST S STS®s. L L-1 a_ ABANDONED REMOVE EXISTING PIV LL' ABANDONED' ABANDONED PER S H IEET C_20 ABANDONED PER ABANDONED PER SHEET C20 FVALVES (T-YP OF 15) PER SHEET C20 PER S H T C20 SHEET C20 & CONC GUARD WALL r (OR POSTS), NOTE 3 REMOVE HYDRANT H9, AND SHEET C20 svi _SV 17 SEC7A VALVES & POSTS 120'ST( ---P ER S HE ET G-2&- BEND TS 2" S T S p 1 SV19 10K u9 � TEE: W/ PLUG-, r!5 _ f D 07 m.nd - - - - - - - - -- E p 90" YEN f : f - - - - - - - - - - - _1:tHPW- -1 t HPW- UP HPW -- - - - - - - - - _ercw - - - - - - - - - - - - - - - - - - -- - -- - - - -4 77- - - - - - - - fr CW,-r C1 -frcw- -Ircwl- BEND go'A ell- 90" YEN 6"GM BEND REMOVE EXISTING HPW,-,&--D,OMEST'IC HYD ASSEMBLY PER REMOVE EXISTING CONCRETE GRADE REMOVE EXISTING WATERLINE BETWEEN RENTON STD DETAIL BEAMS, WALLS AND PILE CAPS PER REMOVE EXISTING HPW & DOMESTIC P' NEW MAIN CONNECTIONS 6.7 (TYP OF 2). SEE SHEET C20 AS NECESSARY FOR MANHOLE & VALVE WATERLINE BETWEEN PER SHEET C20 SPEC SECTION 02665 PIPE INSTALLATION TYP PER SHEET C20--/ NEW MAIN CONNECTIONS 725' FOR APPROVED MANUFACTURER .' - PER SHEET 20 .4) 61' 58' 5 3.9' 46 62' 52.5' - 7.31 8.2' 57.75' 56.5' 5' 5' 60.7' 61' 31 FOR CONNECTION SEE RENTON ST D NOTES LGATE VALVE DETAIL 6.29 (i�P OF 4) PLAN INSTALLED IN VAULT 1 20' 1. MAINTAIN EXISTING CW AND HPW MAINS IN 6, ALL WORK AND MATERIALS SHALL MEET OR SIMILAR TO RENTON EDGE OF SERVICE UNTIL NEW MAINS HAVE BEEN INSTALL- EXCEED CITY OF RENTON STANDARD DETAILS OR STD DETAIL 6.18 /----CONCRETE 3' CLEAR ED, DISINFECTED FLUSHED AND TESTED. AS MODIFIED BY BOEINkj STANDARD SPECIFICA- PIPE TEES & 90' SIZE ENDS BEND 4 4 4 6 8 10 8 1" 12 10 18 26 12 28 36 NOTE: UNITS IN SQUARE FEET. 45* 22.5* 11.5! BEND BEND BEND VALVES 4 2 4 6 4 2 0 1 1 6 4 6 14 8 4 8 20 12 6 10 THRUST BLOCK BEARING AREA NO SCALE 18 l) S (i R FAC E T 00 C-5 C, TRENCH BACKFILL Cb CLASS 11, 95%MAX 0 DRY DENSITY COMPACTION ;z �iz 8" D 1 rBEDDING TYPE X, 1417 8" LIFTS, 95% COMPACTION 6" MAX OD+ 1.0'MAX FOR SINGLE PIPE TYPICAL PIPE TRENCH SECTION NO SCALE SUBGRADE ,VERTICAL TRENCH SUPPORT SYSTEM BY CONTRACTOR AS REQUIRED 6" MAX I 12" DI UNDISTURBED NATIVE MATERIAL OR FOUNDATION GRAVEL AS NECESSARY ---- # 5 x L O..,--GUARD POST # 5 x 2'- 6" I T r l' u rC 114 r_ m REINFORCEMENT PLAN 12" H P W 8" CW OK TO ENCASE CW, SEE/�-�_ 4 GUARD POSTS EA PIV AND HYDRANT SIMILAR TO TYPICAL HPW CONNECTION NO SCALE EXISTING PIV TO BE REMOVED TYPICAL HPW SECTION NO SCALE ,,,-CONCRETE PAD AT PIV AND HYDRANT LOCATIONS IN AREAS OF ASPHALT PAVING PIV JOINT MATERIAL EXIST PIV NOT SHOWN 7-77— ;J77 --- SEE RENTON STD DET 6_4 CONNECT TO EXIST 6" OR 8" PIPE _J" 127Sys S ROTATE BENDS AS NECESSARY TO MAKE OFFSET CONNECTION TION 02665. THE INSTALLATION SHALL MEET THE 2. SUBMIT PHASED CONNECTION PLAN WHICH WILL REQUIREMENTS OF THE NATIONAL FIRE PROTECT - MINIMIZE HPW DOWN TIME. ION ASSOCIATION'S NFPA 24. 3. SALVAGE ALL POST INDICATOR VALVES AND 7. ALL PIPE SHALL BE DUCTILE IRON PIPE CLASS HYDRANTS AND TURN OVER TO OWNER. 53 CEMENT LINED WITH JOINTS RESTRAINED WITH SHACKLE RODS AND TIE BOLTS PER 4. ALL FIRE PROTECTION MATERIALS SHALL BE RENTON STANDARD DETAIL 6.5. APPROVED BY FACTORY MUTUAL AND ALL HPW VALVES SHALL BE GATE VALVES WITH POST 8. ALL PIPE SHALL BE WRAPPED WITH 8n,,'! INDICATORS. POLYETHYLENE PER APWA C-105, 5, PROVIDE POST PROTECTION SIMILAR TO HYDRANT 9. THE WATER MAINS SHALL BE BURIED WITH 4.5 PER 4/C101 FOR ALL POST INDICATOR VALVES. FEET OF COVER MINIMUM. PLACE POSTS AS DIRECTED FOR MULTIPLE VALVES, 10. EXTREME CARE SHALL BE USED WHEN WORKING IN THE VICINITY OF OR CROSSING THE EXISTING WATER MAINS TO MAINTAIN FIRE PROTECTION AND DOMESTIC WATER SERVICE UNTIL NEW SYSTEMS ARE OPERABLE. PROPOSED EXISTING m G % 7 IF4 /Aim A LEGEND PROPOSED EXISTING MANHOLE -A- - COMPRESSED AIR SECTION VALVE -W- - WASTE TYPE I CATCH BASIN -CW- - - < COLD WATER POST INDICATOR VALVE -FM- - FORCEMAIN (PIV) __ss__ SANITARY SEWER - -HPW- HIGH PRESSURE WATER TYPE 11 CATCH BASIN -STS- -STS- STORM DRAIN BURIED UTILITY jj1PIfj4S.ojjjj,TED -GM- - GRAVITY MAIN "I"O[ID DRAWING," KRA1\,.-"L..R, CHIN MAYO (;ON, JJIIT!��Cj E,.k PY THE CONTRA( LL I 0,' _U311 �, i z :1 0 0 co, > m M 0-0 M z o z z 31 z 0 y. jg :0 Z m I I (3 rrjw sm.7 Lo --A%04V ic T 0 r- 0 0 o m m a) 0 < z 0 z co 0 z G3 z