Loading...
HomeMy WebLinkAboutWWP1202168.1PORTION OF THE NE 114 OF SECTION 5, TO WV SHI P 23 N. , SA NI TAR Y SEWER NO TES & SPECIRCA TIONS 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFI CA 77ONS OF THE CITY OF RENTON U 77LI TY DEPARTMENT AND THE LATEST EDI77ON OF THE WSD T/AP WA STANDARDS AND SPECIFI CA T10NS. 2. THE HOURS OF WORK IN THE STREET RIGHT—OF—WAY SHALL BE LIMITED TO 8: 30 A.M. TO 3: 30 P.M. ON WEEKDAYS UNLESS OTHER WISE APPROVED IN WRI77NG BY THE DEPARTMENT OF PUBLIC WORKS AT 235-2620. ALL STREET CLOSURES, PARTIAL, OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. J. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDI T70N (AP WA) AND CITY OF RENTON STANDARD SPECIFICATIONS 4. ALL LOCA 77ONS OF EXIS77NG U 71LI TIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCA T70N SO AS TO AVOID DAMAGE OR DISTURBANCE. 5. A PRE —CONSTRUCTION CONFERENCE AND A 24 HOURS N077CE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCT70N. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE U77LITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILL ALL CONSTRUCTION. 6. CONTRACTOR /S SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTI0N SITE. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER HER PLANS. 9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS —BUILT DRAWING OF THE SANI TAR Y SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OF LICENSED PROFESSIONAL SURVEYOR. 11. BACKF7LL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 18 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS. HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G. S. 14. ALL DISTURBED AREAS SHALL BE SEEDED MULCHED OR OTHERWISE STABILIZED TO THE SA TISFAC77ON OF THE DEPARTMENT FOR THE PREVENTION OF ON —SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 5. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UN YIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE. 16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 17. IN UN —IMPROVED AREA c MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH FA WNG. WWP-/2-216$ RAISE-1/2" WIDE BORDER 1-1/4" SIDE SEWER MAIN TO RANGE 5 E., PROPER TY LINE BUILDING SEWER c ? ' FUTURE 6" SEWER PIPE �' 6 °' BLDG SEWER �6" SIDE OUTLET TEE ?, 2"X4" STUD SERVICE ARKER PAINT UPPE`ON WHITE l W AND STENCIL ONRSIDE WORD Q. 'SEWER- Wl TH 3" HIGH BLACK LETTERS. S" SIDE SEWER & BUILDING SEWER PLAN 6" SIDE SEWER 1: J. 5 MIX NO TE:• CONCRETE 60' ALLOWABLE MAX SIDE SEWER SHALL HAVE A BLOCKING FOR CASTOR MINIMUM 5' COVER AT PROPERTY X DUC77LE IRON PIPE- LINE OR 3-5' LOWER THAN THE 67MIN- LOWEST HOUSE ELEVATION, WHICH - a 25MIN EVER /S LO WER. _t 6"MIN HORIZONTAL 6" SIDE OUTLET TEE SEWER MAIN CONC. BLOCKING ANGLE OF 7FE A T MAIN OVER 25' ELEVA 77ON 2X MIN SLOPE TYPICAL SIDE SEWER ELEVA 77ON 1" EXISTING SEWER MAIN 6" SIDE SEWER f 6 "TEST TEE TO BE INSTALLED A T CONNEC 77ON NOTE': MAKE TAP 7HROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VI TRIFIED CLAY, PLAIN & REINFORCED CONCRETE, DI & Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED. SIDE SEWER SERVICE DETAIL 3/4" SQUARES SPACED — 3/4" r AS INDICATED — HT. 1 /8" 1" 12"0 CL5. FIBER PACKIr —51 " -- " 450(1 /8) 7/8 4 7— 3/4 " 8" 15 CAST IRON RING AND COVER A� 10"-® 9" IF­8-3/4". 1/2"-1 r 2„ PIPE MATERIAL AS SPECIFIED BY THE ENGINEER ' II 1 PLUG TO BE SEALED ""-T -- IN SAME MANNER AS MAIN SEWER JOINTS. 6 11 0 OR 8 11 0 CLEAN— OU TN. T.S W. M. NE. 20TH STREET VICINITY MAP -Q� BENCHMARK CITY OF RENTON NO. 1088 RAILROAD SPIKE I' UP NORTH FACE POWER POLE S. W. COR. INT. N.E. 20th & BLAINE A VE. N. E. ELEVA PON = 307 93 CONCRETE CLASS 3000 ASPHALT CONCRETE (3" MIN) REPLACEMENT PATCH TO BE - I" 7HI CKER THAN PREVIOUSLY EXISTED. EXISTING ASPHALT CONCRETE div FINAL JOINT MUST BE SA W- CU T 6" MIN CRUSHED SURFACING TOP COURSE Cc,[,lFACTED CLASS "B" F IT RUN (-R, VE/ OR APPROVED EQUAL. TYPICAL S THE T PA TCHI N G DETAIL N. T. c ON TOUMA ENGINEERS 15"a Woo t14mw ran► . a -164 wt MOO (am) 2ff5-4100 F"SION BY I APPR. I DATE s d&2168 CITY OF RENTON DEPARTMENT OF PUBLIC WORKS SANITARY SEWER EXTENSION 2005 ABERDEEN AVE. NE. JOB NO. GJS DATE: SEPT. 1994 525-124-941 DRAWN: GCS SCALE DWG -NO CHECKED: M.T. NIA 525124D T APPROVED: SHEEP: 1 OF: 2