Loading...
HomeMy WebLinkAboutSWP2702240.2En w O Z J Q ff W Z W Z �I 0 0 U Z C7 (.Do Z W IY O — F- 't J W — w J (n U :3 to aA 4#6 FILENAME: MILL1 PLOT DATE: 8/9 /91 DRAWN E.M.L. CHECKED DNP PROJ. ENGR. J.E. JOHNSON DIST. ADM. R.Q. ANDERSON LEGEND EXISTING NEW ..._.._----....... ---- --.......— __ 12 " .................. --------- - 1 2" S " �' 4' G -r B T -rj OP ',.3T....._.__ .... �y l a'16.91 REVISED SHEET #'S PER WSDOT DATE REVISION REcioN STATE FED. AID PROD. NO NO. 10 WASH JOB NUMBER I-IR-405-3(783). 91WO97 CONTRACT NUMBER BY PP'D OS� 0 D O UD TOT4L SHEETS WATER LINE SAN SEWER LINE GAS LINE BURIED TELEPHONE OVERHEAD POWER STORM SEWER MANHOLE CATCH BASIN SANITARY CLEANOUT FIRE HYDRANT WATER METER GATE VALVE UNDER 12" GATE VALVE IN CHAMBER 12" TELEVISION J BOX TELEPHONE VAULT ELECTRICAL J BOX DITCH ASPHALT CONCRETE GUTTER UNDER DRAIN HMF WAY DMSION APPROVED GENERAL UTILITY NOTES: I. ALL PIPE AND FITTINGS FOR WATERLINES SHALL BE CEMENT MORTAR —LINED DUCTILE IRON. ALL PIPE SHALL BE THICKNESS CLASS 52, UNLESS OTHERWISE SHOWN. PIPE JOINTS MAY BE PUSH —ON OR MECHANICAL JOINT, UNLESS OTHERWISE SHOWN. ALL FITTING JOINTS SHALL BE MECHANICAL JOINTS, UNLESS OTHERWISE SHOWN. PE SLEEVES SHALL BE INSTALLED BETWEEN MECHANICAL JOINT FITTINGS WHERE REQUIRED. 2. ALL VALVES 12 INCHES IN DIAMETER OR LARGER SHALL BE INSTALLED IN A VAULT. GATE VALVES SHALL BE SUITABLE FOR 250 PSI OPERATING PRESSURE AND SHALL BE METROSEAL 250, AS MANUFACTURED BY U.S. PIPE, OR APPROVED EQUAL, 3. FIRE HYDRANTS SHALL BE IN ACCORDANCE WITH DETAIL WD-7 4. ALL WATER MAINS SIX INCHES IN DIAMETER AND LARGER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE 2 LB/CU FT DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. 5. UNLESS OTHERWISE SHOWN, MANHOLES SHALL BE AS FOLLOWS: MANHOLES OVER 7'-0" DEEP — DETAIL WD-8 MANHOLES 4'-0" TO 7'-0" DEEP — DETAIL Q WD-8 6. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS, OHIO OR EQUAL APPROVED IN WRITING. SHACKLE ALL WATERLINE BENDS. FOR RUNS OF JOINT RESTRAINTS IN EXCESS OF 20' WITHOUT FITTINGS, RESTRAINED JOINT PIPE MAY BE USED. JOINTS MUST BE CAPABLE OF BEING DEFLECTED AFTER ASSEMBLY. 7. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 8. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, WITHIN TEN DAYS, WEATHER PERMITTING. 9. BLOCKING FOR CONVEX VERTICAL BENDS IN WATERLINES SHALL BE IN ACCORDANCE WITH WSDOT STD. PLAN B-22. TURNBUCKLES SHALL BE USED. 10. CAUTION — EXTREME HAZARD — OVERHEAD ELECTRICAL SERVICE LINES ARE GENERALLY NOT SHOWN ON THE DRAWINGS. ELECTRICAL LINES SHOWN ON THE DRAWINGS ARE LOCATED BY POINT—TO—POINT, POWER POLE —TO —POWER POLE CONNECTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL FOLLOW PROCEDURES DURING CONSTRUCTION AS REQUIRED BY LAW AND REGULATION. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH UTILITY OWNERS AND DETERMINE THE EXTENT OF HAZARD AND REMEDIAL MEASURES AND SHALL TAKE WHATEVER PRECAUTIONS MAY BE REQUIRED. - II. IDENTIFICATION, LOCATION, MARKING AND RESPONSIBILITY FOR UNDERGROUND FACILITIES OR UTILITIES IS GOVERNED BY THE PROVISIONS OF CHAPTER 19.122, REVISED CODE OF WASHINGTON, 12. SIDEWALK PATCHING SHALL MATCH EXISTING THICKNESS AND FINISH. D 221#002 FOR "AS CONSTRUCTED PANS" ONLY CHECK FOR COMPLIANCE T `-:-,;'D, RDS to 8 42 -9 v le Date � Washington States Vi Department of Transportation VAS RoseWater Engineering, Inc. SR 405 SOUTH RENTON TO SUNSET BLVD. HOV MILL AVENUE UTILITY LEGEND AND GENERAL NOTES SN-171 SHEET 100 Of 10?4 SHEETS A9 �'• /� -.2 afG ec, 2