Loading...
HomeMy WebLinkAboutSWP2702240.363 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 0 11 v 10 cn v w w 9 (nrn ZQ 8 0 7 U U Iq\ 6 a, r- z cn w r 0 w 05 J H Z z a o=>� v r— • w3 0 w =0.= cn Ln = N2 1 To 23N o 9 Ro 5E o 9 Wo Mo LEGEND EXISTING STORM SEWER - D EXISTING SANITARY SEWER - S \ STORM SEWER NN CATCH BASIN ❑ F i MANHOLE \ N . ,. Q A \ N . CJ ` o \ N , i1 — N \ o 0 x— x— J-- ----- -- - - - - -- \ , co + .I 4. , \ \ \� cn I - IN .>> \ NN IN. \} ° \ IN 00 __ --------- ----------i-#-------------------------------y---- - - - --- ------ 4 �,' \� J ------ _ - -- -- -- -- —_ _ N-- ------- - - - ---------------------- - - - ----------------__� ''-----____- - ----- - ------ ----- TN — —_ _.a.c _SR 51-5 -- —--- - - - - -----------_________-__ 2-------3---------� --- -I N ==4=_______ g-____-__-____-______________--__�____=- ---- --- _ (MAIN AVE. S.)--------- \\ ---_ ---_ �z____=__-- =-------------------------------- r j �o- � lJ \ ` GENERAL NOTES: 1. ACCEPTABLE ALTERNATIVES: A) TR, 5 GALV. STEEL STORM SEWER PIPE, 0.064 IN. THICK, DIAM. AS SHOWN. B) TR. 2 GALV, STEEL STORM SEWER PIPE, 0.064 IN, THICK, GASKETED OR WELDED LONGITUDINAL SEAM, 3 INCHES LARGER THAN DIAM. SHOWN. C) TR. 5 ALUMINUM ALLOY STORM SEWER PIPE 0,060 IN. THICK, DIAM. AS SHOWN. D) PLAIN ALUMINUM ALLOY STORM SEWER PIPE, 0.060 IN. THICK, GASKETED LONGITUDINAL SEAM, 3 INCHES LARGER THAN DIAM. SHOWN. E) TR. 5 ALUMINIZED STEEL STORM SEWER PIPE, 0.064 IN, THICK, DIAM. AS SHOWN. F) PLAIN ALUMINIZED STEEL STORM SEWER PIPE, 0.064 IN. THICK, GASKETED OR WELDED RE-METALIZED LONGITUDINAL SEAM, 3 IN. OR LARGER THAN DIAM. SHOWN, G) PLAIN ALUMINUM ALLOY SPIRAL RIB STORM SEWER PIPE, -0.060 IN. THICK, DIAM. AS SHOWN. H) TR, 2 GALV. STEEL SPIRAL RIB STORM SEWER PIPE, 0,064 IN. THICK, DIAM. AS SHOWN, I) PLAIN ALUMINIZED STEEL SPIRAL RIB STORM SEWER PIPE, 0,064 IN. THICK, DIAM. AS SHOWN. Sw)D-s7-2s4f0 i 'Q 9 N� 5A Q 2. 3. 4. ----- I� N • r I� X I� . a. I ,Q. ACCEPTABLE ALTERNATIVES: I^ bit UD �—------------ _ _ - _ ---------------~ -------- - - - - -- A) PLAIN ALUMINUM ALLOY STORM SEWER PIPE, 0.079 IN. THICK,--- ------_________ TY— -Q- - _ LONGITUDINAL SEAM, 3 IN. LARGER THAN DIAM. SHOWN. x------------ GASKETED -_,--_`---__-_-- — B) PLAIN ALUMINIZED STEEL STORM SEWER P I PE , 0.079 IN. THICK? --r ---, GASKETED LONGITUDINAL SEAMS 3 IN. LARGER THAN DIAM. SHOWN. - C) PLAIN ALUMINIZED STEEL STORM SEWER PIPE 09079 IN. THICK, WELDED RE-METALIZED LONGITUDINAL SEAM, IN. LARGER THAN DIAM. SHOWN. ACCEPTABLE ALTERNATIVES ARE: A) TR, 2 GALV, STEEL STORM SEWER PIPE, 0.109 IN. THICK, GASKETED LONGITUDINAL SEAM, 3 IN. LARGER THAN DIAM. SHOWN, r g) TR. 2 GALV. STEEL STORM SEWER PIPE, 0.109 IN. THICK,--`r---------- ------ WELDED LONGITUDINAL SEAM 9 3 I N . LARGER THAN DIAM. SHOWN, -�---------------- NO PIPE ALTERNATIVES ARE ACCEPTABLE. REGION ISTATEI FED. AI D PROJ . N0. DESIGNED BY W. SENSOR 1 10 IWASH ENTERED BY S. STRASSMAN CHECKED BY G. WEBBER / W. SENSOR JOB NUMBER PROD. I=NGR. J. JOHNSON 91WO97 DIST. ADM. R. 0. ANDERSON 10-21-91 ADDED DRAINAGE CODES RL CONTRACT NO. `f0 a DATE DATE REVISION BYJ I-IR-405-3(783) 0 50 100 SCALE IN FEET HIGHWAY DIVISION 4 Washington State Deportment of Transportation ZGA2:1110004191W097F.DGN;1 Dak,224003 FOR "AS CONSTRUCTED PLANS" ONLY SR 405 SOUTH RENTON TO SUNSET BLVD.-HOV DRAINAGE PLAN D-1 SHEET 104 OF (o'54 SHEETS