Loading...
HomeMy WebLinkAboutSWP2702266.11cn 45' MAXIMUM EXISTING TEE SEE NOTE 1 3' MAXIMUM LENGTH OF FIRST PIECE OF STRAIGHT PIPE BEND IF NEEDED —\ EXISTING TEE SEE NOTE 1 12" CPEP TO DOWNSTRI z 0.05 FT/FT MINIMUM SLOPE CD REMOVE CONFLICTING SIDE SEWER NEW STORMWATER PIPE RELOCATION ABOVE NEW STORM PIPE (TYP) SEE DRAWING BELOW FOR DETAILS AND NOTES NEW STORMWATER PIPE 0.0 2 FT/ FT MINIMUM SLOPE EXISTING SEWER MAIN EXISTING SIDE SEWER REMOVE CONFLICTING SIDE SEWER POSSIBLE CLEANOUT SEE NOTE 5 POSSIBLE CLEANOUT SEE NOTE 5 CONNECT SIDE SEWER WITH ELASTOMERIC �z FLEXIBLE COUPLING INSTALL 6"x 4" REDUCER, IF NEEDED 1/ 8, 1 /1 6, OR 1 /32 NEW 6" SIDE SEWER BENDS AS NEEDED FOAM BLOCK, SEE NOTE 4 SIDE SEWER RELOCATION (TYP SCALE: NTS 12" CPEP DND 12" FROM UPSTREAM FROM CB 17 OVABLE G, SEE E 3. L r Kelm CB 1 6A 12" EXISTING PLAN VIEW - CBI N 12" CPEP 1 TO POND 4 12" CPEP TO DOWNSTREAM 4„ CB 16 REMOVABLE PLUG, SEE NOTE 3. XX � 2" FROM CB 17B BEVELLED END ASPHALT CONCRETE PAVEMENT CL B, 0.3' COMPACTION DEPTH CSBC, 0.5' MIN COMPACTED DEPTH ASPHALT ACCESS ROAD SCALE: NTS XX NOTES: 1. INSTALL SADDLE IF EXISTING TEE IS NOT USEABLE FOR RECONNECTION. SADDLE W/6" TEE (ROMAC OR APPROVED EQUAL). SECURE TO MAIN WITH STAINLESS STEEL BANDS. TAP THRU SADDLE. 2. CONCRETE BLOCK REQUIRED AT NEW SADDLE WHEN ANGLE AT MAIN EXCEEDS 25°. SEE CITY DETAIL DWG BR39. 3. ALLOWABLE SIDE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35 OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 4. FOR 3" SEPARATION INSTALL 1 'X 2' X 2" THICK STYRENE FOAM BLOCK BETWEEN NEW PIPE AND 6" SIDE SEWER RELOCATION. 5. IF SIDE SEWER RELOCATION REACHES CURB EXTEND NEW 6" SS TO BEHIND SIDEWALK AND INSTALL CLEANOUT PER CITY DETAIL DWG BR33. 6. ALL SIDE SEWER RECONSTRUCTIONS SHALL BE APPROVED BY CITY INSPECTOR. + SECTION 14 / _ �► 12 EXISTING FROM UPSTREAM 3 ±, SEE NOTE 2. 12" FROM�'i CB 17A PLAN VIEW - CB1 7 NOTES: 1. PIPE LOCATIONS AND DIMENSIONS ARE NOT TO SCALE AND ARE SHOWN FOR SCHEMATIC PURPOSES ONLY. THEY MAY VARY FOR EACH CB. 2. THE CENTERLINE OF CB 17 SHALL BE OFFSET FROM THE EXISTING 12" STORM PIPE TO THE EAST TO THE DIMENSIONS SHOWN. 3. REMOVABLE PLUG SHALL BE FOR 12" CPEP ADS #1233AA OR APPROVED EQUAL. DETAIL - CATCH BASINS 16 AND 17 SCALE: NTS REMOVABLE PLUGS INSTALLED IN CB-16, 17 TO DIRECT FLOW INTO DETENTION POND. FOR MAINTENANCE, CHANGE PLUG BLOCK OFF POND AND DIVERT FLOW TO DOWNSTREAM SYSTEM o, Reid S1 N -o o��ss/ONAI XX TRENCH EXCAVATION SEE DETAIL FOR PAVEMENT PATCH BACKFILL MATERIAL NATIVE IF IT MEETS SPECS, OR IMPORT PER SECTION 9-03.19 (BANK RUN GRAVEL). NEW STORMWATER PIPE PIPE ZONE MATERIAL PER SECTION 9-03.16 BEDDING MATERIAL FOR THERMOPLASTIC PIPE -EXCAVATION OF UNSUITABLE SOIL (IF NEEDED) DEPTH AS APPROVED BY ENGINEER BACKFILL WITH FOUNDATION MATERIAL MEETING SECTION 9-13.6 QUARRY SPALLS NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT PIPE ZONE MATERIAL TO 90% MINIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY. 4. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. CPEP STORM PIPE TYPICAL TRENCH BEDDING AND BACKFILL SCALE: NTS Ej F.. LL MANHOLE AND CATCH BASIN PENETRATION AND ORIGINAL PLANS STAM EFLEXIBLE JOINT DETAIL WYMAN REIDADAMS ON5/27/03 SCALE: NTS XX PE #39578 EXPIRES: 4/25/04 H MHIL AS —BUILT INFO AND NOTED ADDED BY CITY OF RENTON .i wp j7•��as NO. REVISION SURVEYM. SCALE CH2M HILL WNMWAWAL W t� W/lWl ono, AS SHOWN R. CHUNG J. PRETS ONE INCH DATUM DWC 7/20/04 cxEa®: AT FULL SCALE R. ADAMS F WT ONE INCH BY DATE I APPR AF o: SCALE ACCOM U T. PLATIN xx Dow226614D AT MANHOLE OR CATCH BASIN CUT PIPE END AS-UIL NOTE: IF THERE IS NO CHANNELING FOR THE PIPE BEING PLUGGED, STEEL TROWEL THE PLUG TO A SMOOTH SURFACE CONFORMING TO THE INSIDE SURFACE OF THE MANHOLE OR CATCH BASIN. IF THERE IS CHANNELING, FILL THE CHANNEL FOR THE PIPE BEING PLUGGED WITH CONCRETE. STEEL TROWEL ALL EXPOSED NEW CONCRETE SURFACES SMOOTH. PIPE PLUGGING DETAILS SCALE: NTS CITY OF RENTON Planning/Building/Public Works Dept. EvZI RECOMMENDED FOR APPROVAL BY DANIEL CAREY 5/28/03 RONALD STRAKA 6728/03 BY N.E. 10th STREET/ANACORTES AVE. N.E. DETENTION POND AND STORM SYSTEM IMPROVEMENT PROJECT DRAINAGE DETAILS MAY 2003 rCAI x s a z N o' c� �y s s N N SCANNED OCT 0 8 2ftP