HomeMy WebLinkAboutSWP2702306.15w a z U Ld 0 EXISTING TEE SEE NOTE 1 0.05 FT/FT MINIMUM SLOPE -------------- CONFLICTING SIDE SEWER STORMWATER PIPE POSSIBLE CLEANOUT SEE NOTE 5 45° MAXIMUM SIDE SEWER RELOCATION ABOVE OR BELOW NEW STORM PIPE (TYP) POSSIBLE CLEANOUT SEE NOTE 5 REMOVE CONFLICTING EXISTING SIDE SEWER-,,," SIDE SEWER MAXIMUM LLINU IN NEW STORMWATER PIPE OF FIRST PIECE OF STRAIGHT PIPE CONNECT SIDE SEWER WITH ELASTOMERIC BEND IF NEEDED FLEXIBLE COUPLING INSTALL EXISTING TEE 6"x 4" REDUCER, SEE NOTE 1 IF NEEDED 3" MIN. EXISTING -- - -- - SEWER MAIN �-- - 1 /8, 1 /16, OR 1 /32 0.02 FT/FT BENDS AS NEEDED MINIMUM SLOPE NEW 6" SIDE SEWER (90' NOT ALLOWED) FOAM BLOCK, SEE NOTE 4 NOTES: 1. IF EXISTING TEE IS NOT USEABLE FOR RECONNECTION CONTRACTOR SHALL CUT IN A NEW TEE REPLACEMENT. 2. CONCRETE BLOCK REQUIRED AT NEW SADDLE WHEN ANGLE AT MAIN EXCEEDS 25% SEE CITY DETAIL DWG 406.1. 3. ALLOWABLE SIDE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35, OR OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 4. FOR 3" SEPARATION INSTALL VX 2' X 2" THICK STYRENE FOAM BLOCK BETWEEN NEW PIPE AND 6" SIDE SEWER RELOCATION. 5. IF SIDE SEWER RELOCATION REACHES CURB EXTEND NEW 6" SS TO BEHIND SIDEWALK AND INSTALL CLEANOUT PER CITY DETAIL DWG 406.1 , 407. 6. BEDDING SHALL BE WSDOT 9-03.12(4) GRAVEL BACKFILL FOR DRAINS. 7. ALL SIDE SEWER RECONSTRUCTIONS SHALL BE APPROVED BY CITY INSPECTOR SIDE SEWER RELOCATION (TYP) _ (NTS) _..----EX. 6" OR 4" SIDE SEWER (TYP) PVC SPOOL (LENGTH AS NEEDED DIAMETER TO MATCH EXISTING) FERNCO "STRONG -BACK" COUPLING (TYPE AS NEEDED) EX. SEWER MAIN J EX. MAIN SIZE X 6" 1. BEDDING SHALL BE PER WSDOT SPECIFICATION 9-03.12(4) GRAVEL BACKFILL FOR DRAINS. SEWER TEE REPLACEMENT DETAIL (TYP CIVIL ENGINEERS & LAND SURVEYORS 2009 MINOR AVE. EAST (206) 323-4144 SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 E-MAIL: info@brhinc.com (NTS) ................... Rol ra ; SEE NOTE 4 1: FRAME AND VANED GRATE Z__j CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM ADJUSTMENT SECTION CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. For TYPE 1 and TYPE 2 Catch Basins BASE SECTION NOTES 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRATE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT THE COVER OR GRATING IN PLACE PER WSDOT STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND. ticY o STD. PLAN - 202.00 o�� PUBLIC WORKS CATCH BASIN INSTALLATION F�,.to DEPARTMENT MARCH 2O08 CATCH BASIN INSTALLATION (TYP) STD PLAN 202.00 (NTS) NEW STORMWATER PIPE NEW 8"PVC FOAM BLOCK SEWER MAIN Q CDF FILL FLEXIBLE COUPLING EX 8" SEWER CONIC I--- 5' - 5' -1 NOTES: 1. ALLOWABLE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35 OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 2. INSTALL Vx 2'x 2" THICK STYRENE FOAM BLOCK BETWEEN NEW SD PIPE AND NEW SEWER MAIN. 3. FLEXIBLE COUPLING SHALL BE FERNCO "STRONG -BACK" COUPLING, TYPE AS NEEDED. 4. BACKFILL CROSSING WITH CDF, DO NOT COVER COUPLINGS. RECOMMENDED FOR APPROVAL BY DANIEL CAREY 9/4/13 BY NoWN60yeril SEWER MAIN CROSSING (TYP SURVEYED: BRH DESIGNED: DWC DRAWN: DWC CHECKED: DWC, RJS BY DATE APPR APPROVED: RJS (NTS) 2" HMA OR ACP CLASS B' HMA OR ACP CLASS "B" SEE NO TE 2 PAVEMENT PATCH PAY LIMIT 6.5' MIN. 1' 12.5' 1' 1' MIN MIN MIN MIN MIN 2" SAWCUT AND REMOVE OR GRIND. �SEAL WITH AR- 4000W �6" CRUSHED SURFACING TOP COURSE COMPACT TO 957 MODIFIED PROCTOR i TRENCH BEDDING AND BACKFILL, i SEE DETAIL TRENCH WIDTH AS REQUIRED BY PIPE SIZE (SEE WSDOT STD SPEC 2-09.4) PLUS ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED, SHALL MEET WSDOT STD SPEC 7- 08.3(1)8. NO TES: 2. MINIMUM THICKNESS AND MATERIAL SHALL BE.• PRINCIPAL/MINOR/COLLECTOR, ARTERIAL & INDUSTRIAL ACCESS STREETS - 6"HMA OR ACP CLASS "B'; RESIDENTIAL ACCESS STREETS - 2" HMA OR ACP CLASS "B'; IN NO CASE SHALL THE THICKNESS BE LESS THAN THE EXISTING PAVEMENT SECTION. TYPICAL PATCH FOR FLEXIBLE PAVEMENT 1 PER STD PLAN - 110 (NTS) TRENCH EXCAVATION PAY LIMIT 30" ID - 5 1 /2' 24" ID - 5' 12" ID - 3 1 /2' SEE DETAIL FOR PA VEMEN T PA TCH BACKFILL MA TERIAL WSD 0 T SECTION 9 - 03.19 BANK RUN GRAVEL, OR NA TI VE MA TERIAL IF I T MEETS SPECS. PIPE ZONE MA TERIAL WSDOT 2006 SECTION 9-03.12(3) GRA VEL BACKFILL FOR PIPE ZONE BEDDING NEW UTILITY PIPE EXCA VA TION OF UNSUITABLE SOIL (IF NEEDED) DEPTH AS APPROVED BY ENGINEER BACKFILL WITH FOUNDATION MATERIAL MEETING WSDOT SECTION 9-13.6 QUARRY SPALLS NO TES 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. J. COMPACT PIPE ZONE MATERIAL TO 95% MAXIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY 4. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE THAT THE FLOW LINE IS MAINTAINED. TYPICAL TRENCH BEDDING AND BACKFILL SCALE: VERTICAL: NAVD 1988 As Noted HORIZONTAL: NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE ��---------- Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY (NTS) D=2306 NE 5TH PL / EDMONDS AVE NE STORM SYSTEM REPLACEMENT PROJECT STORM DETAILS 15 DATE: 9-4-13 FIELDBOOK: PAGE: DRAWING NO: 2013009.00 SHEET: OF: 15 x Z}� D qz I-) Z 1�0 C iDm 3 ru z m z m m O D D 0 0 o0 c Cf) �W RD �z mo mm 0K fU z z m 0 D Y, C m m 0 O tt y areaP'' 'b l �I `J' a C a� `° z zy to O r� C� y I m �T] o�� D H O C - 3 / G\ DI-1213ID16