HomeMy WebLinkAboutSWP2702711.2U)
ABBREVIATIONS
AVE AVENUE
AC ASBESTOS CEMENT PIPE
ADJ ADJUST
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ASPH ASPHALT
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS
ASSY ASSEMBLY
BF BLIND FLANGE
BLDG BUILDING
BLK BLOCK
BO BLOW OFF
CTR CENTER
CAP CORRUGATED ALUMINUM PIPE
CB CATCH BASI N
CI CAST IRON
q_ CENTER LINE
CLR CLEARANCE
CMP CORRUGATED METAL PIPE
CO CLEANOUT
CONC CONCRETE
C CONDUIT
CONN CONNECTION
CONTR CONTRACTOR
CONT CONTINUOUS
CPEP CORRUGATED POLYETHYLENE PIPE
CPLG COUPLING
CY CUBIC YARD
CONT CONTINUED
CL CLASS
CF CUBIC FEET
CFS CUBIC FEET PER SECOND
ABBREVIATIONS
RED
REDUCER
REINF
REINFORCE
READ
REQUIRED
R/W
RIGHT-OF-WAY
SL
SLOPE
S
SOUTH
SCH
SCHEDULE
SF
SQUARE FEET
SFM
FOUND MONUMENT
SHT
SHEET
SPECS
SPECIFICATIONS
SQ
SQUARE
SSCO
SANITARY SEWER CLEANOUT
SSMH
SANITARY SEWER MANHOLE
SSNT
SET NAIL/TAG
SSRC
SET REBAR/CAP
STA
STATI O N
STD
STANDARD
TC
TOP OF CURB
TEL
TELEPHONE
THRD
THREADED
THRU
THROUGH
TYP
TYPICAL
VERT
VERTICAL
W
WEST
W/
WITH
W/O
WITHOUT
WTR
WATER
DC DEGREE OF CURVATURE SYMBOL LEGEND
DI DUCTILE IRON
DIA DIAMETER EXISTING PROPOSED
DOT DEPARTMENT OF TRANSPORTATION
DIM DIMENSION
DWGS DRAWING(S)
D DRAIN
EOA EDGE OF ASPHALT
E EAST
EA EACH ,
EL ELEVATION
EL ELBOW
ELEC ELECTRICAL
EXIST EXISTING o
F FORCE MAIN
FIG FIGURE
FIN FINISHED
FL FLANGE
FT
FEET
FO
FIBER OPTIC —
FOC
FACE OF CURB
GA
GAUGE
GALV
GALVANIZED —
GI
GALVANIZED IRON
GV
GATE VALVE
HDPE
HIGH DENSITY POLYETHYLENE PIPE
ID
INSIDE DIAMETER
IE
INVERT ELEVATION
NV
INVERT
IN
INCH
LB
POUND
POD
10---
LF
LINEAR FEET
TV
MAX
MAXIMUM
MFR
MANUFACTURER
FO
MH
MANHOLE
MIN
MINIMUM
P
MJ
MECHANICAL JOINT
MISC
MISCELLANEOUS
T
N
NORTH
W
NO
NUMBER
NTS
NOT TO SCALE
OC
ON CENTER
OD
OUTSIDE DIAMETER
PI
POINT OF INTERSECTION
—
PP
POWER POLE
S
PVI
POINT OF VERTICAL INTERSECTION
—
PE
PLAIN END
PERF
PERFORATED
SD
PVC
POLYVINYL CHLORIDE
PVMT
PAVEMENT
SD
PVT
POINT OF VERTICAL TANGENT
PC
POINT OF CURVATURE
PT
POINT OF TANGENCY
F
QTY
QUANTITY
R
RADIUS
RET
RETAINING
RR
RAILROAD
D
x x X—
Q� P. B
of WAs� `4�- x X—
� � a
o
YFTI
O 37338 q w�
14 s IST1;�4��15 O
/ yg �cNAL
�O 11 EXPIRES:8/20/200`7
C�.y 8z 08bo�e, I�
C❑NSULTING ENGINEERS
701 DEXTER AVENUE NORTH SUITE 200
SEATTLE, WASHINGTON 98109 (206) 284-0860
W
SD
SD
DESCRIPTION
CURB & GUTTER
ASPHALT PAVEMENT
GRAVEL SURFACING
CONCRETE SURFACING
CONCRETE SIDEWALK
RIGHT-OF-WAY LINE
CENTERLINE OF ROADWAY
PROPERTY LINE
PERMANENT EASEMENT LINE
TEMPORARY EASEMENT LINE
CONTOUR LINE
BURIED CABLE TV
BURIED FIBER OPTIC
BURIED POWER
BURIED TELEPHONE
WATER MAIN (SIZE AS NOTED)
GAS MAI N
IRRIGATION LINE
SANITARY SEWER
STORM DRAIN (DIA. < 10")
STORM DRAIN (DIA. >= 10")
SANITARY SEWER FORCE MAIN
DITCH
CULVERT (SIZE & TYPE AS NOTED)
FENCE (TYPE AS NOTED)
FENCE (WITH GATE)
TELEPHONE VAULT
POWER VAULT
TELEPHONE MANHOLE
NO. I REVISION
SYMBOL LEGEND
EXISTING
O
0
0
NOTED
NOTED
cr
LZ
PROPOSED
N
fi
DESCRIPTION
MANHOLE OR DRYWELL (AS NOTED)
CLEANOUT
TYPE 1 CATCH BASIN OR CURB INLET
TYPE 2 CATCH BASIN
POLE WITH GUY WIRE
POWER / TELEPHONE / GUY POLE
LUMINAIRE
YARD LIGHT
JUNCTION BOX (AS NOTED)
GATE VALVE
BUTTERFLY VALVE
WATER METER
FIRE HYDRANT
REDUCER
THRUST BLOCK
TRANSITION COUPLING OR
FLANGE COUPLING ADAPTER
CAP/PLUG
BLOW -OFF
WELL
MAIL BOX (NOTED)
SIGN
EMBANKMENT
TREE (CONIFER)
TREE (DECIDUOUS)
aq ; �
BUILDINGS
ROCK WALL
ELEVATION POINT
MONUMENT
o ANGLE POINT /CONTROL POINT
BENCH MARK
� DETAIL NUMBER
1
REFERENCE SHEET
BY
SURVEYED:
DESIGNED:
B.B.
DRAWN:
P.M.
CHECKED:
S.C.
DATE APPR APPR:
B.B.
GEOTECHNICAL BOREHOLE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTKAL. NAVD 19M
HORIZONTAL: NAD 19f0/1991
DATU M
GENERAL CONSTRUCTION NOTES
1. ALL TYPE 2 CATCH BASINS AND ACCESS RISERS SHALL HAVE FLAT TOPS
2. LENGTHS OF PIPE AND INVERT ELEVATIONS ARE SHOWN AT CENTERLINE OF
STRUCTURE. PAYMENT FOR THE BOX CULVERT WILL BE BASED ON ACTUAL
CULVERT INSTALLED FROM FACE OF INSIDE WALL TO FACE OF INSIDE WALL OF
EACH STRUCTURE.
3. CONSTRUCTION WORK HOURS SHALL BE FROM 7:00 AM TO 5:00 PM, MONDAY
THROUGH FRIDAY UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS.
4. THE CONTRACTOR SHALL IDENTIFY IN ADVANCE, WATER SERVICE LINES THAT MAY
BE DAMAGED DURING INSTALLATION OF STORM PIPE. IF WATER SERVICE LINES
REQUIRE REMOVAL TO FACILITATE STORM PIPE INSTALLATION, THE CONTRACTOR
SHALL COORDINATE WITH CITY MAINTENANCE CREW. THE FOLLOWING PROCEDURES
SHALL BE FOLLOWED:
1) CONTRACTOR SHALL EXPOSE WATER SERVICE LINE.
2) CITY MAINTENANCE CREW WILL SHUT OFF WATER AND TEMPORARILY
CUT AND CAP SERVICE LINE.
3) CONTRACTOR SHALL INSTALL STORM PIPE AT WATER SERVICE CROSSINGS.
4) WHEN CONTRACTOR IS A SUFFICIENT DISTANCE BEYOND WATER SERVICE
LINE, THE CITY MAINTENANCE CREW WILL INSTALL A TEMPORARY
SPLICE.
5) CITY MAINTENANCE CREW WILL REPLACE WATER SERVICE WITH A COPPER
LINE AT A LATER DATE.
D-271102
UTILITY NOTE:
THE CONTRACTOR SHALL CALL THE UTILITY LOCATION REQUEST CENTER
(ONE CALL CENTER; 1-800-424-5555) FOR FIELD LOCATION OF UTILITIES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION,
DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WITHIN THE PROJECT,
WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES
AND SURVEYING THE VERTICAL AND HORIZONTAL LOCATION PRIOR TO
CONSTRUCTION. ALL POTENTIAL UTILITY CONFLICTS SHALL BE POTHOLED A
MINIMUM OF FIVE WORKING DAYS IN ADVANCE OF ANY PIPELINE TRENCH
EXCAVATION. THE UTILITIES SHOWN ON THE PLANS ARE BASED UPON
AVAILABLE INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS
OCCUR THE CONTRACTOR SHALL CONSULT THE PROJECT ENGINEER TO
RESOLVE THE PROBLEM PRIOR TO PROCEEDING WITH CONSTRUCTION.
CI TY OF
RENTON
Planning/Building/Public Works Dept.
RECOMMENDED FOR APPROVAL
By: �D o1_. ^-� --- Date;
By'----------- - Date: --------
By°---------------- Date: --------
By: Dater -------
D�-�2�7� 1 102
DATE:
RENTON VILLAGE STORM SYSTEM PROJECT FIE
4/LDBOOK: K:
PAGE:
DRAWING NO:
VICINITY & LOCATION MAPS, SYMBOL LEGEND,
AND INDEX
SHEET, 2 OF: 12