Loading...
HomeMy WebLinkAboutSWP2702711.6I 0-1 BANK RUN GRAVEL EX. 144" 0 - CATCH BASIN 10'-0" MIN. CARRIER PIPE (C900) STEEL CASING PLACE END SPACER MAX. OF ONE (1) FOOT FROM END OF CASING (TYP.) SEAL END OF CASING WITH NEOPRENE CASING END SEALS (CALPICO END SEALS OR APPROVED EQUAL) 4' X 6' PRECAST CONC. BOX CULVERT 10'-0" MIN. IF A BELL ENDS UP INSIDE CASING THEN ONE SPACER SHALL BE PLACED ON THE SPIGOT END AND BE IN CONTACT WITH THE BELL OF THE JOINT. I -------------------- MAX. DISTANCE BETWEEN SPACERS SHALL BE SIX (6) FEET 0. C. ROMAC NG7 OR EQUAL. (TYP. EACH END) 24" SEWER ENCASEMENT PROFILE j MINIMUM ENCASEMENT INSIDE DIAMETER (I.D.) CARRIER DIA. IN. ENCASEMENT I.D. IN. 8 18 10 21.5 12 23 18 36 ANTICORROSIVE COATING THICKNESS: CASING - 8 MILLS DFT EXISTING 12" CONC. NOTES: SEWER PIPE 1. CASING SPACERS (CALIPCO OR EQUAL) SHALL BE "CENTER POSITIONING" TYPE. MINIMUM RUNNER WIDTH SHALL BE 2" 2. RUNNER HEIGHT SHALL BE SIZED TO PROVIDE: A. MIN. 0.75" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES B. MIN. 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING DURING INSTALLATION. 36" FRAME AND GRATE OR RING AND COVER ASPHALT PAVEMENT AS NOTED PER PLANS 16" MAX. 4" MIN. 36" DIA. RISER AND 8 ADJUSTMENT SECTION 48" DIA. MANHOLE M FLAT SLAB COVER PER RENTON STANDARD DETAIL B027. EPDXY AREA EPDXY AREA & GROUT & GROUT WITH WITH GUNITE MIX RIM EL. 29.48 GUNITE MIX ••- - 4' X 6' PRECAST CONC. BOX CULVERT NOT TO SCALE 4' X 6' PRECAST CONC. BOX CULVERT I 1 , � I I I 1 � 1 G I.E. 20.73 I.E. 2 0.9 2 72" DIA. CC °L ---- - SD PIPE EXISTING KNOCKOUT b PROVIDED. GROUT BOX CULVERT TO I.E. 20.73 EXISTING STRUCTURE. 48 DIA. CC SD PIPE NOTE: CONTRACTOR SHALL DRILL 1" HOLES AT 2" SPACING TO PROVIDE KNOCKOUT SUITABLE FOR PIPE CONNECTION TO EXISTING 144" CATCH BASIN. CONNECTION TO EXISTING STORM DRAINAGE r3 SCALE: 1 /4"=1 '-O" 5 I 148" MIN. 72" MIN. a 0 x--ry 0mrN 3-#6 ® SPRINGLINE FULL LENGTH BOTH SIDES 4' X 6' PRECAST CONC. BOX CULVERT NOTES r- 11-rAi m 1. CLASS 5000 CONCRETE GROUT INTERFACE AREA TO BE CLEANED AND TREATED WITH BONDING AGENT. 2. SEE RENTON STANDARD DETAIL B019 FOR FRAME AND GRATE OR B074 FOR RING AND COVER ASSEMBLIES. 3. PREFABRICATED LADDER PER CITY STD. DETAIL. DRILL AND EPDXY ALL STEPS AND HANDHOLDS, 12" MAX SPACING. TYPICAL ACCESS RISER 4 SCALE: 3/8" = 1'-O" - SEE SHEET 8 FOR - ASPHALT PAVEMENT REPAIR NATIVE BACKFILL --` OR BANK RUN GRAVEL PIPE BEDDING SEE SPECIFICATIONS NATIVE BACKFILL OR BANK RUN GRAVEL 1 10'-0" MIN. CARRIER PIPE (C900) 36" STEEL ENCASEMENT PIPE 4' X 6' CONC. BOX CULVERT (CAST IN PLACE SECTION) 10'-0" MIN. IF A BELL ENDS UP INSIDE CASING THEN ONE SPACER SHALL BE PLACED ON THE SPIGOT END AND BE IN CONTACT WITH THE BELL OF THE JOINT. I ------- -------- J------------------- --- ---- --- PLACE END SPACER MAX. OF ONE (1) FOOT FROM END OF CASING (TYP.) SEAL END OF CASING WITH NEOPRENE CASING END SEALS (CALPICO END SEALS OR APPROVED EQUAL) ------------------- --- - MAX. DISTANCE BETWEEN SPACERS SHALL BE SIX (6) FEET O.C. UNKNOWN PIPE DEPTH, SEE SHEET 11, DETAIL 4 70r1 011771AI= CAI/ AC%rRACAIT nnrlrll r N T TO SCALE SEE PAYMENT LIMIT NOTE 18 MAX. SEE TRENCH NOTE FINISHED] GRADE EXISTING 18" CONC. SEWER PIPE ROMAC COUPLING OR EQUAL. (TYP. EACH END) SEE PAYMENT LIMIT NOTE 20 MAX. SEE TRENCH NOTE FINISHED GRADE ,�� SEE SHEET 8 FOR ASPHALT PAVEMENT REPAIR ^% SPECIAL PRECAUTIONS ,y w, TO PROTECT CULVERT \, ; -Ti 2" TO THIS LEVEL. DEPTH 12" ' MIN. TO CULVERT CROWN MIN. ``' X 6 , VARIES, SEE PLANS 4 ''� 4' X 6' NATIVE BACKFILL BOX CULVERT BOX CULVERT OR BANK RUN GRAVEL. SEE SPECIFICATIONS. L 12" � o hoc— . g 24" LIGHTWEIGHT CDF (SEE SPEC.) 12'-0" I SEE PAYMENT LIMIT NOTE '1 L 12'-0" SEE PAYMENT LIMIT NOTE GOOD SOILS POOR SOILS PAYMENT LIMIT NOTE THE TRENCH SECTIONS SHOWN ON THE PLANS ARE FOR THE PAYMENT LIMITS FOR PIPE BEDDING AND SURFACE RESTORATION. PAYMENT FOR ALL PIPE BEDDING AND SURFACE RESTORATION SHALL BE FROM THE MEASUREMENT OF THE CONSTRUCTED TRENCH SECTION TO THE MAXIMUM LIMITS AS INDICATED ON THE TRENCH DETAILS OR THE EXTENT OF PAVEMENT RESTORATION SHOWN ON THE SHEET RESTORATION PLAN, SHEET 8. TRENCH NOTE: CONTRACTOR SHALL MINIMIZE TRENCH SLOUGHING USING APPROVED TRENCH SHORING EQUIPMENT. SEE SPECIFICATIONS. NOTE: ACTUAL EXTENT OF LIGHTWEIGHT CDF IN POOR SOILS TO BE DETERMINED BY A GEOTECHNICAL ENGINEER IN THE FIELD. D-271106 TYPICAL BOX CULVERT TRENCH SECTION SCALE: 1/4" = 1'-O" RECOMMENDED FOR APPROVAL By;- D,*-�- G� __ Date: -�/- I - a By`---------------- Datel-------- By`---------------- Date: -------- Byl---------------- Dater ------- SURVEYED: SCALE DACE, 4R�ro NAD 1983/1991 CITY OF L: q DESIGNED: AS SHOWN HORIZONTAL 4/6/07 B.B. RENTON VILLAGE STORM SYSTEM PROJECT FIELDBOOK: C.y Osborne, DRAWN: P.M. RENTON PAGE: CHECKED: AT �E111NCH lF DATU M DRAWING No: CONSULTING ENGINEERS Planning/Building/Public Works Dept. 701 DEXTER AVENUE NORTH SUITE 200 S.C. IF NOT ONE INCH SEATTLE, WASHINGTON 98109 (206) 284-0860 NO. REVISION BY DATE APPR 'APR°` g B. SCALE ACCORDINGLY DETAILS SHEET: 6 OF: 12