HomeMy WebLinkAboutWTR2702928.7N
1
a
o�
w
m
J
O
Li
V)
r
0
Lv
Q
0
CD
z
0
J
HORIZONTAL BEND
i
Y-
\
TEE
!'
y> -
VERTICAL BEND
VALVE ANCHOR
OFFSET
ALTERNATE
VERTICAL BEND
SHIM PLATE NOTES:
`BLANK PLUG
PLUGGED END FOR
FUTURE EXPANSION
-1 "BARS
PLUGGED TEE
PLUGGED
CROSS
\
\
PLUGGED
CROSS
1. ALL CONCRETE FOR BLOCKING SHALL BE
FIVE (5) SACK MIX.
2. ALL BLOCKING SHALL BE POURED AGAINST
FIRM, UNDISTURBED EARTH.
3. BLOCKING AGAINST FILL MATERIAL, DISTURBED
OR POOR SOILS SHALL BE DESIGNED BY
DISTRICT ENGINEER.
CONCRETE BLOCKING-
N. T. S.
NOTE: COPPER LINE BETWEEN CORP STOP
& ANGLE STOP SHALL BE ONE PIECE (NO
FITTINGS)
w) I lw
z z
z
>_
Li
� w
0 w O
v �
w I a
18"(TYP)� /
I
T13" MIN
36" MIN 10" MAX.
—ANGLE CURB STOP, LOCKWING 3' MIN COVER
FORD KV 43-444W BY CTS GRIP JOINT
MUELLER H14258-1"METER SIZE WATERMAIN SERVICE SADDLE ROMAC 101
& CORPORATION STOP, FORD F1000 BY
1" TYPE K COPPER AS APPROVED BY CTS GRIP JOINT OR MUELLER H-15008
DISTRICT. EXPANSION LOOPS APPROX. 10' ABOVE SPRING
MUST BE HELD FLAT AS POSSIBLE. LINE.
ROADWAY WITH CURB AND GUTTER
w Iw
z) w z
J I Z I J
I w >-
w Z
w
a w a
O 0 O
a a
ELI
I
18"(TYP)� i
� 36" MIN
I r
8" MIN
10" MAX.
3' MIN COVER
— ANGLE CURB STOP, LOCKWING
FORD KV 43-444W BY CTS GRIP JOINT
MUELLER H14258-1"METER SIZE WATERMAIN SERVICE SADDLE ROMAC 101
& CORPORATION STOP, FORD F1000 BY
1" TYPE K COPPER AS APPROVED BY CTS GRIP JOINT OR MUELLER H-15008
DISTRICT. EXPANSION LOOPS APPROX. 10' ABOVE SPRING
MUST BE HELD FLAT AS POSSIBLE. LINE.
ROADWAY WITH DITCHES
TYPICAL ROADWAY SECTION.
N.T.S.
1• TYPE K COPPER
? SERVICE LINES
a
<
Z �
z
w
X �
a
N
PLAN VIEW
rnoonoenrua ctno
WITHOUT SIDEWALK WITH SIDEWALK
IN R/W
RW
LOT
Meter
i�
I
o f
i�
I
a
Meter
LOT
NTAL
ION
zz
Meter
a PROP. LINE
0R m Meter
Y
V Q
o� 5' PERM.
s� ESMT (TYP)
1' MAX.
WITH SIDEWALK
IN ESMT
METER BOX LOCATION
N.T.S.
CONCRETE STRADDLE BLOCK
w/ SHACKLE RODS TO G.V.
BLOCKING SHALL BE POURED
AGAINST UNDISTURBED EARTH
& SIZED BASED ON PRESSURE SHACKLE
OF WATER MAIN &SOIL RODS
CHARACTERISTICS
w
8" (OR LARGER)
WATER MAIN
8" (OR LARGER) PI A AI
GV: MJxMJ
ASPHALT PAVEMENT
(A U
a a_
18"-24" CAST
>z
VALVE BOX
0
STRADDLE BLOCK w/�
z_ ¢
SHACKLE RODS
N
6
F -.
NOTES
4" RED: PExPE
CONCRETE TYPE METER BOX,
FOGTITE NO. J20S TYPE 1 OR
APPROVED EQUAL w/ STEEL
BOLT —DOWN COVER PLATE
4"PVC PLUG
4" THREADED FLG.—\�
r- 4"
4" ADAPT:MJxFL
-4"D.I.P. RISER
4" 90' BEND: MJxMJ
8" (OR LARGER) W
WATER MAIN 8" (OR LARGER)
GV: MJxMJ 81.x 4" RED: PExPE
ELEVATION
1. SHACKLE RODS:2 EA. 3/4" GALV. STEEL TIE RODS w/ ONE HEAVY COAT OF COAL
TAR PRESERVATIVE ON TIE RODS, NUTS & BOLTS AFTER INSTALLATION.
2. MEGA -LUGS REQUIRED ON ALL MJ FITTINGS.
3. NO MARKING POSTS REQUIRED.
4. SIZE & USE ADDITIONAL REDUCERS AS NECESSARY FOR MAINS LARGER THAN 8".
4" BLOWOFF ASSEMBLY FOR 8"
OR LARGER MAINS FOR FUTURE
EXTENSION (IN PAVING)
N.T.S.
1"MIN — 2"MAX. FROM INSIDE
FRONT WALL OF METER BOX
(TYPICAL FOR ALL SERVICES) —
CARSON STANDARD
FIBERGLASS METER
BOX #1324-15L w/
READER LID
ANGLE STOP W/LOCK WING, —
FORD KV43-444W BY CTS
GRIP JOINT MUELLER
H14258-1"METER.
TYPE K COPPER
1" ANGLE CHECK VALVE
FORD HA34-444 OR
LID APPROVED EQUAL
PACK JOINT
11" NIPPLE
V
4'-1" TYPE K COPPER
1" PACK JOINTx FIPT CPLG.
FORD C14-44 OR APPROVED
EQUAL
NOTES:
1. DO NOT BACKFILL UNTIL ALL BRASS
FITTINGS HAVE BEEN INSPECTED BY
THE DISTRICT.
2. SERVICE SIZES ARE 1" UNLESS
OTHERWISE DESCRIBED IN THE
SPECIFICATIONS.
SINGLE SERVICE
TYPICAL SERVICE DETAIL
N.T.S.
FIRE HYDRANT SHALL BE COMPRESSION
TYPE EITHER CLOW MEDALLION; M & H 929
OR MUELLER CENTURION 250 WITH 6" MECHANICAL
JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE
OPENING. TWO 2-1/2" HOSE CONNECTIONS
NATIONAL STANDARD THREADS. 4" PUMPER
CONNECTION CITY OF SEATTLE THREADS WITH
A STORTZ ADAPTOR, 4" SEATTLE THREADS
WITH A STORTZ ADAPTOR, 4" SEATTLE THREAD
X 5" STORTZ, ATTACHED WITH 1 /8" STAINLESS
STEEL CABLE. 1-1/4" PENTAGON OPERATING
NUT. FIRE HYDRANT TO BE PAINTED WITH TWO
COATS OF PAINT. PRESERVATIVE PAINT NO. 43-655
SAFETY YELLOW OR APPROVED EQUAL. PUMPER
CONNECTION TO FACE ROADWAY ASSEMBLY.
CONCRETE STRADDLE BLOCK FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED.
w/ SHACKLE RODS TO G.V.
BLOCKING SHALL BE POURED
AGAINST UNDISTURBED EARTH CONCRETE
& SIZED BASED ON PRESSURE
OF WATER MAIN & SOIL BLOCKING
CHARACTERISTICS
SHACKLE 8"x 4" RED: PExPE
RODS VALVE MARKER POST
(SEE DETAIL)
A
8" (OR LARGER)
WATER MAIN +!> CONCRETE TYPE METER BOX,
FOGTITE NO. J20S TYPE 1 OR
8" (OR LARGER) PLAN APPROVED EQUAL w/ STEEL
GV:MJxMJ BOLT —DOWN COVER PLATE
VALVE MARKER POST
(SEE DETAIL)
2" THICK CONC. OR ASPHALT 4"PVC PLUG
PAD 2' AROUND BOX & VALVE
BOX 4" THREADED FLG-�
r4"
Q w 18"-24" CAST IRON
w VALVE BOX
>z
o0 0 STRADDLE BLOCK w/�_4" ADAPT:MJxFL
SHACKLE RODS
4"D.I.P. RISER
6"
{ 4" 90• BEND: MJxMJ
T8" (OR LARGER) 8"x 4" RED:PExPE
WATER MAIN 8" MJ LARGER)
GV:MJxMJ
ELEVATION
NOTES
1. SHACKLE RODS:2 EA. 3/4" GALV. STEEL TIE RODS w/ ONE HEAVY COAT OF COAL
TAR PRESERVATIVE ON TIE RODS, NUTS & BOLTS AFTER INSTALLATION.
2. MEGA —LUGS REQUIRED ON ALL MJ FITTINGS.
3. SIZE & USE ADDITIONAL REDUCERS AS NECESSARY FOR MAINS LARGER THAN 8",
4. THE GROUND WITHIN 3' RADIUS OF BLOWOFF SHALL BE GRADED UNIFORMLY.
4" BLOWOFF ASSEMBLY FOR 8"
OR LARGER MAINS FOR FUTURE
EXTENSION (OFF PAVING)
N.T.S.
BLOW -OFF MARKER POST WILL
BE REQUIRED UNLESS BLOW -OFF
IS IN PAVEMENT.
BLOW —OFF ASSEMBLY
MARKER POST
VALVE MARKER POST WILL BE
REQUIRED UNLESS VALVE IS IN
PAVEMENT AND TOP OF VALVE
BOX IS AT FINISHED GRADE.
VALVE MARKER POST
NOTE: MARKER POST PAINTED WITH 2 COATS OF FARWEST PAINT CASE YELLOW PN# X3472.
LETTERS SHALL BE 2" HIGH AND STENCILED IN BLACK PAINT.
V
.9
W
Q
0
N
w
0
CQ
H
CQ
co
co c0p
L
w
MARKER POST 00
N.T.S.
CL N
t�
0 0
18" TO 20" BEHIND BACK OF CURB o z z Y
OR 12" BEHIND BACK OF SIDEWALK TWO—PIECE CAST IRON VALVE BOX
w � � c�
WITH LUG TYPE COVER. EQUAL TOCL co
THAT IS ADJACENT TO CURB `lc Q � o � o
OLYMPIC FOUNDRY CO. STANDARD
8" TOP SECTION WITH REGULAR BASE
SECTION LENGTH TO FIT. VALVE NUT v a c
EXTENSION AS REQUIRED (SEE DWG BR46a co
/PAGE B090).
MAX „ t0 00 p 01
MIN 2' RAISED PAVEMENT MARKER TYPE 88 A8 L °" N � , o
STIMSONITE TWO-WAY BLUE. N a,
uj CR
z ui u
L m v 04
U° a
��1� 42" MIN CONCRETE BLOCKING m tm- u_
BURY
Wgm292808
CAST IRON TEE. WITH 6" FLANGE SIDE OUTLET. —
c\l
- C
� =;�:.� .: °':-.; ='. RESILIENT N T SEAT
A 09 RES L E
� .... X MJ AWW C 5
" AT VALVE FL
.. 6 GATE ,
( W
6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT
TWO 3/4 STEEL TIE RODS. SEE STD DETAIL FOR TIE RODS.
F-
16" x 8" x 4" MININUM = ® z
CONCRETE BLOCK
UNDER HYDRANT 1 /3 CU. YD. WASHED DRAIN ROCK (3" TO 3/8")
W -
f U O W
FIRE HYDRANT ASSEMBLY
(MODIFIED FROM CITY OF RENTON STANDARD DETAIL) O
WATER DISTRICT NO. 90 b z
Z 0 qO
APPROVED z 0
CONSTRUCTION DATE:r
DRAWINGS: LLI
- W
LEVEL ALL GROUND W m
MIN 3' RADIUS z Q
Q L-
ONE MAN ROCK ® 0
6 Q CL
W
CUT FILL
HYDRANT LOCATION IN CUT OR FILL
(CITY OF RENTON)
N.T.S. BASE MAP
SHEET OF
DRAWING C6.32
SCANNED MAR 2 8 ZUUJ