HomeMy WebLinkAboutWTR2702953.115c CS N C\1 ►i i I 8 J m s w ¢ 5 J E 0 co 0 A B I C D I E F UNION FOR LINES LARGER THAN 4" USE 1 " NI PT WELDOL�_T FACTORY FILLED CAPILLARY TUBE W/SS JACKET (NOTE 1) OR NIPPLE TO INSTRUMENT. DIAPHRAGM SEAL (NOTE 1) 1 BALL VALVE (NOTES 2, 4) 1 " NPT CLOSE NIPPLE 1 4 CINii innrn `) VALVE ANIFOLD SURFACE MOUNT GAGE OR INSTRUMENT (NOTES 2, 3 L (NOTE 2) v vu vv 2—VALVE MANIFOLD NOTE 3 (BLOCK & BLEED) NOTE 4 1 /2" LINE CLASS VALVE 0 (SECTION 15050) NOTE 1 NOTES: 1. KEEP CAPILLARY TUBES AS SHORT AS POSSIBLE. CLOSE COUPLE NOTES: INSTRUMENT OR GAGE TO DIAPHRAGM SEAL WHERE SHOWN ON DRAWING. 1. A ROOT VALVE IS REQUIRED IF THE 2—VALVE MANIFOLD IS NOT CLOSE 2. USE 1/2" NIPPLE AND VALVE FOR CONNECTION TO SYSTEM -COUPLED TO THE LINE. PIPING 4 INCHES AND LESS. USE 1" ELSEWHERE. 2. SNUBBER IS REQUIRED FOR VIBRATION SERVICE. 3. USE A LINE —SIZE TEE FOR 2" AND SMALLER. 3. USE STAINLESSSTEEL TUBING & FITTINGS IN CORROSIVE AREA. 4. TYPICAL PRESSURE TAP 4. FOR LOCATION OF TAP SEE DETAIL 1. DIAPHRAGM SEAL PROTECTOR DETAIL TYPICAL PRESSURE INSTRUMENT r2_"� LIQUID STEAM, VAPOR OR SLURRY AIR OR GAS cn w PREFERRED o 0 oCA PREFERRED ALTERNATE PREFERRED ALTERNATE LTERNATE ALTERNATE LIQUID OR SLURRY STEAM, VAPOR, AIR OR GAS cn PREFERRED J ALTERNATE ALTERNATE Q PREFERRED ALTERNATE ALL FLUIDS NOTE: PREFERRED THIS ORIENTATION FOR TEMPERATURE ALTERNATE w INSTRUMENTS WILL NOT APPLY IF THE ALTERNATE °- PIPE DIAMETER IS SMALL AND REQUIRES Lij A TEE OR ELBOW TO BE USED. CONNECTIONS IN HORIZONTAL MAIN LINE ORIENTATION OF INSTRUMENT CAPPED INDICATING TYPE WALL TRANSMITTER 2,, GRS PIPE 0 3—VALVE MANIFOLD I - �c� cV 6" o PRESSURE LINE PORT HIGH AND LOW 0 O CC 0 1/47EEL O 0 0 1 /4" GALVANIZED STEEL 0 0 MOUNTING PLAT MOUNTING BRACKET LEVELING GROUT AS REQUIRED STAINLESS STEEL U-BOLT FLOOR STAND WALL MOUNT NOTES: 2" GRS PIPE 1 HOT DIP GALVANIZE AFTER FABRICATION. 2. TYP. MOUNTING PLATE: 6" x 6" x 3/16" WITH FOUR 5/8" HOLES. 3. PROVIDE FOUR 2" x 9/16" CAPSULE ANCHOR BOLTS. INSTRUMENT MOUNTING 4 TRANSMITTER MOUNTING 5 I SCALE: NONE 117 SCALE: NONE 117 117 SCALE: NONE SCALE: NONE 117 SCALE: NONE 117 3/4" LIQUID TIGHT CONDUIT TRANSMITTER NEMA 4X ENCLOSURE 3" FF WELD NECK FLANAlELEVEL SWITCHES STAINLESS STEEL 3/4" CONDUIT — / CONDUIT ANCHOR BOLT DRILL 1" DIA. VENTS TO PLC (TYP 2) ON 1 FT CENTERS�z S CABLE TYPE X2 PIPE PENETRAT LMFR MATING 4" FF STAINLESS STEEL SEE M30 FLANGE (TYP) 4 FLAT FACED ANGLE BRACKET - a <-� (NOTE 1) NOZZLE (PART OF Ll 3" SCH. 80 TANK) (NOTE 3) STAINLESS STEEL ROD PVC PIPE. CONC. DECK N 3/4" NIPPLE (NOTE 3) 4" DIA 316 SS, SCH _40 PIPE DISPLACER FLOAT (TYP.) CLOSED o 3/4" COUPLING (NOTE 3) - ° N RETAINER. SHIM PVC PIPE PVC COUPLING TO CENTER WELL IN (AS REQ'D) TANK o RETAINER TEFLON FLOAT a � 2 SHIM - --- 2_ 1 "W x 41 SLOTS SONIC PROBE 17 a 1-3 NOTE 2 NOTES 12" Ox 1 /4" THICK 316 SS 1. PROVIDE W/ INSTRUMENT. a PLATE W/ TWO 3/8"0 ° �► 2. LOCATE PER PROBE MFR'S INSTRUCTIONS TO PREVENT INTERFERENCE. a ° EXPANSION ANCHORS < 3. USE CPVC SCH. 80 NIPPLES, COUPLING AND FLANGE IN CORROSIVE ATMOSPHERE. NOTE: 4. LEVEL SENSOR (LSH) IS SIMILAR. POSITION SENSOR AS REQUIRED BY ENGINEER. PROVIDE SIMILAR STILLING WELL FOR LEVEL TRANSDUCERS IN BELOW GRADE BASINS. ULTRASONIC PROBE & SENSOR INSTALLATION SUMP LEVEL FLOAT LEVEL SENSOR STILLING WELL WITH LEVEL SWITCH 6 7 8 SCALE: NONE ! 17 SCALE: NONE 117 SCALE: NONE 117 N cr N 01 4 0 F.— a w J Q1... 3 En 3 3 O U a) Y (1) C� O w Un 3 0 0 O O rri v7 0 N 1 / CD L.� Y — RECORD DRAWING 12/05 w Z NO. REVISION BY DATE APPR J 10 a 7 0 W 4 3 W=2953124 2 RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these _Record Drawings assume all risk of loss resulting from their use. SURVEYED: SCALE: NONE CITY OF RENTON DATE: 1 DESIGNED: MDL VERTICAL: NAVD 1988 � ECONOMIC AND ENGINEERING — Planning/Building/Public Works Dept. DEC 2005 DRAWN: LMM ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks PROJECT No. CHECKED: MDL Consultants SERVICES, INC. MAPLEWOOD 3-01-358 AT FULL SCALE 10900 NE 4th STREET, SUITE 1110 REVISION No. APPROVED: WATER TREATMENT AND GOLF COURSE IMPROVEMENTS - 32001 32nd Avenue South, Suite 100 BELLEVUE, WASHINGTON _ 98005 IF .NOT ONE INCH DATUM Federal Way, ,Washington 98001 sHT No. SCALE ACCORDINGLY PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / DLYMPIA, WA INSTRUMENTATION DETAILS DWG No. i17R ° E F G " ' J K L M A3 N WI-12.9 5 31A Al 0 L� W- J VI W