Loading...
HomeMy WebLinkAboutWTR2702953.134J m 0 w C w N I O O N CN Q w 0 0 w Q ry ry / 0 0 Y cn 0 0 0 O w Cn 0 I 0 Q I O r7 Ln n O r- N O w L� 0 w z w J co N N I 0 8 E3 C J 231 15 3/4"C-1 # 18 TSP (TYP) .n Lr-) Ln �n n Cl- ANALOG WIRING DIAGRAM 18TSP (TYP) LOCAL AFD CONTROLLER 17 E TO (E) CP-1 01 FS -;zt- rr) cN Ln LO Ln DISCRETE WIRING DIAGRAM F SCALE: NONE E19 E 99 SCALE: NONE NOTES: 7 O RETAIN (E) DOOR SWITCHES (2). REPLACE (E) SMOKE SENSORS (2) AND THEIR (E) WIRING TO (E) CP-1 WITH NEW SENSORS TO MATCH EXISTING. OREMOVE (E) WIRING TO (E) CHLORINATORS. ABANDON (E) CONDUIT. (E) PANEL A CIRCUITS A-30 AND A-32 TO BE DISCONNECTED AND LABELED AS SPARES.. OREMOVE (E) WIRING TO (E) INJECTION SOLENOIDS. O REMOVE (E) WIRING TO (E) CHLORINE RINSING SPRINKLER SYSTEM. ABANDON (E) CONDUIT. (E) PANEL A 6 CIRCUIT A-26 IS TO REMAIN AS SPARE. 50 REMOVE TWO (E) CHLORINE RINSING SPRINKLER DISABLE PANELS AND TWO (E) CHLORINE DETECTORS AND ONE (E) INDICATOR. REMOVE (E) SPRINKLER VALVE CONTROL CABINET, (E) WIRING TO CP-2 & ABANDON (E) CONDUITS AT FLOOR. SEAL ALL HOLES IN WALL. G) RETAIN (E) CIRCUITS A-8 & A-10 FOR BOTH (E) HEATERS 07 REMOVE (F) WIRING TO (E) LOUVER DAMPER. ABANDON (E) CONDUIT. (E) CB A-28 TO BE REMOVED. 5 REMOVE THREE (E) CHLORINATOR FEED WIRING AND FOUR (E) LOW CHLORINE LEVEL ALARM WIRING TO (E) CP-1. REUSE (E) CONDUITS AND ROUTE (N) SIGNAL WIRING AS SHOWN. OREUSE (E) CONDUIT FOR CKT A-30 FOR (N) SUB —PANEL "Al ". PROVIDE (N) WIRE FILL. INSTALL 3OA/3P BREAKER A-28,30,32 FOR SUB —PANEL "Al". 10 REPLACE EXISTING SPARE-80A/31P BREAKER IN MCC-1, SECTION E-6 WITH A 30A/3P BREAKER. ROUTE CONDUIT #236 TO MOTOR STARTER. 4 11 SET STARTER ABOVE (E) J—BOX 12 REMOVE ACID SYSTEM CONTROL PANEL AND INSTALL STARTER FOR P-702. REMOVE CIRCUIT B-6. FILL ALL HOLES WITH NON —SHRINK GROUT. 13 REMOVE BASE SYSTEM CONTROL PANEL AND INSTALL STARTER FOR P-701. REMOVE CIRCUIT B-2. FILL ALL HOLES WITH NON —SHRINK GROUT. 14 MOUNT AT 44" ABOVE FLOOR AT TOP OF STAIRS. 3 15 O LOCATE (E) CONDUIT TO (E) TELEMETRY PANEL AND ROUTE NEW SIGNAL WIRE AND RECONNECT. 16 PLACE PB SWITCH 'E' WITH ESCUTCHEON SHOWN ON SHEET 1-14 IN A NEMA 4 BOX AND CONNECT TO (E) CP-1 RTU AS SHOWN. 17 PACKAGE AFD IN A NEMA 4X ENCLOSURE AS SHOWN ON DIAGRAM 15, SHEET E-15. 18 REUSE (E) STILLING WELL. REPLACE TRANSMITTER AND RECONNECT. 2 19 LOCATE UPS (APPROX 65#) ON A SHELF ABOVE BATTERY PACK (FLOOR MTD). HARDWIRE (3/4"C-2#12, 1 #12 GND) UPS TO (E) PANEL A CIRCUIT A-39 AND UPS TRANSFER SWITCH. HARDWIRE TWO UPS CIRCUITS (2, 3/4"C-2# 12, 1 # 12 GND) TO (E) CP-1 TO REPLACE PANEL A CIRCUITS A-39. DISCONNECT WIRES AND REMOVE TO CIRCUITS 40 AND 42 LABEL AS SPARE. 20 STRAP STILL WELL TO WALL INSIDE STAIRWELL ABOVE HWL. C! I` co 00 I I 7 �"C-6#14 (TYP) 3/4"C-2# 14 (TYP) E191 E19 (E) EHH-4 O (N) 5 SPRINKLER F®—S FLOW K A I IN 17 17 10 15 O OIT-7 0 O O O T —751 T ° 7�1) 226 DS O 0 0 O LSH-755 NEW CHLORINE FEED & PUMP ROOM . SEE 1 2 �® O (N) SUB —PANEL "Al" E19 E19E19 E19 0 � 227 9 D O D O 5 20 MP-754 MP-753 MP-752 MP-751 5 6 DS 1 1 3/4"C-2#12, 1#12 GND_00 00N O N N � I I NEW CHLORINE FEED AND PUMP> ROOM 05 BATTERY PACK (N) UPS/BATTERY PACK BELOW 1 1 /n"n nr� //% n I IUI SEE T91 16 OIT— (TYP 5) 227 23 SCALE: 1/2" = 1'-0" — (M) PANEL 'A' 020 227 — (E) MCC-1 J E-6 10 LSH/LSL-218 SEE 8 E19 117 P-702 STARTER 11 12 ROUTE ABOVE DOOR J OO @(N) LE/LIT-217 ® , P-701 STARTER 11 13 218 TO SHH-2 Oi-------------------------- N N N I TO (E) EHH-4AO+-----------------------------� � CON'T ON E-3 J � 14 240 219 (M) PANEL "B" — _ J � I 15 J J J OIT-3 — NOTE 18 1#18 TSP OIT-2 01 01 231 OIT-4 OIT-5 1 @ 6 239 - LE-701 — 02 227 E19 117 234 �— 235 238 230 NaOCL J J I NaOCL STORAGE T 3/4 C-2#14 AGE TANK TK-701 (TYP) o TK-702 I LSH-701 J LSH-702 J J I (IN SUMP) (IN SUMP) J R CORROSIVE AREA M M 1 CORROSIVE AREA o ® J O O OIT-7 0 O ) (O o NaOCL 240 (N) SUB —PANEL "Al"— TRANSFER PUMPS SEE 7 CORROSIVE AREA � P-701 & P-702 E19 i17 sE_ 6 E19 117 0 I 7 I 5 4 3 0 2 4 8 12 ®OIT-6 L�2 a 1 2 3 4 6 W 29531 3 1 /2"=1 '—a., RECORD DRAWING These Record Drawings have been prepared based on information provided TANK K AREA by the contractor and others. Kennedy/Jenks Consultants has not verified the HYP 0 C H LO R ITE STORAGE I accuracy or completeness of information provided to them and does not SCALE: 1 /4 = 1 rr�11 warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. SURVEYED: SCALE: AS NOTED DESIGNED: TEK VERTICAL: NAVD 1988 DRAWN: WL ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks CHECKED: TIW Consultants APPROVED: AT FULL SCALE 32001 32nd Avenue South, Suite 100 IF NOT ONE INCH DATUM Federal Way, Washington 98001 A RECORD DRAWING WL 12/05 SCALE ACCORDINGLY NO. REVISION BY DATE APPR A IB C ID E f G H Al CITY OF RENTON DATE: DEC 2005 ECONOMIC AND ENGINEERING Planning/Building/Public Works Dept. SERVICES, INC. MAPLEWOOD PROJECT NO. 3-01-358 10900 NE 4th STREET, SUITE 11 10 WATER TREATMENT AND GOLF COURSE IMPROVEMENTS REVISION NO. — BELLEVUE, WASHINGTON 98005 PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA BOOSTER PUMP STATION —PARTIAL PLANS SHT NO. POWER AND SIGNAL DWG NO. E19R J K L M N W 2953AA