HomeMy WebLinkAboutWTR2702953.52J m 0 w Q .J E 0 N 0 0 0 N CV Q w Q 0 0 w F- V) Q J 3 0 cn i 3 0 0 Cn U 0 a ry 0 U w 3 0 0 I 0 Q U I 0 i Ln 0 r- N 0 i Ile J 0 Q U w z J A In r✓ m E E 6. SEISMIC LOAD: GENERAL STRUCTURAL NOTES OCCUPANCY CATEGORY ESSENTIAL FACILITIES * SEISMIC IMPORTANCE FACTOR, 1 1.25 LID GENERAL * SEISMIC IMPORTANCE FACTOR, Ip 1.50 (3) * SEISMIC ZONE FACTOR, Z 0.40 N 1. DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 1997 UNIFORM BUILDING CODE, * SOIL PROFILE TYPE Sc rl� 1999 WASHINGTON ADMINISTRATIVE CODE, AND THE REFERENCED BUILDING CODE * SEISMIC SOURCE TYPE C N STANDARDS. * SEISMIC COEFFICIENT, Cc 0.40Nc 2. THESE NOTES AS WELL AS THE TYPICAL DETAILS APPLY TO ALL PARTS OF THE PROJECT, * SEISMIC COEFFICIENT, Cv 0.56Nv UNLESS NOTED OTHERWISE. * NEAR SOURCE COEFFICIENT FACTOR, Nc 1.0 3. SHOP DRAWINGS FOR THIS CONTRACT SHALL BE COORDINATED WITH FAVORABLY * NEAR SOURCE FACTOR, Nv 1.0 REVIEWED EQUIPMENT MANUFACTURER'S DRAWINGS. * OVERSTRENGTH AND DUCTILITY COEFFICIENT, R 4.5 (BUILDING) " ", * RESPONSE MODIFICATION FACTOR, Rw 4.0 (BASINS) 4. DIMENSIONS NOTED WITH AN ASTERISK, * ARE TO BE COORDINATED WITH FAVORABLY REVIEWED EQUIPMENT MANUFACTURER. REINFORCING STEEL 1. REINFORCING BARS SHALL BE ASTM A615-GRADE 60. PERMITS AND INSPECTIONS 2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. g 1. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS 3. ARRANGEMENT AND DETAILING OF REINFORCING STEEL, INCLUDING BAR SUPPORTS AND REQUIRED BY THE LOCAL BUILDING INSPECTOR AND AS DESCRIBED IN THE SPECIFICATIONS. SPACERS, SHALL BE IN ACCORDANCE WITH THE LATEST ACI 315 DETAILING MANUAL. THE CITY WILL PAY AND PROVIDE THE PERMITS FOR THE NEW BUILDING, THE HYPOCHLORITE 4. REINFORCING SHALL LAP A MINIMUM OF OF 1.3 Ld AT SPLICES UNLESS OTHERWISE TANK AND THE ELECTRONIC MONITORING OF HAZARDOUS MATERIALS. SHOWN. WHERE Ld IS THE TENSION DEVELOPMENT LENGTH. WHEN BARS OF DIFFERENT 2. THE CONTRACTOR SHALL SELECT, INSTALL AND MAINTAIN SHORING, SHEETING, BRACING SIZE LAP TO EACH OTHER, SLICE LENGTH FOR THE SMALLER BAR CAN BE USED. AND SLOPING AS NECESSARY TO MAINTAIN SAFE EXCAVATIONS. THE CONTRACTOR DOWELS SHALL HAVE THE SAME SIZE AND SPACING AS THAT OF THE REINFORCING STEEL SHALL BE RESPONSIBLE FOR ENSURING FULL COMPLIANCE WITH 29 CFR PART 1926 THEY ARE SPLICED AND SHALL HAVE A MINIMUM LAP AS NOTED ABOVE. BAR SPLICES OSHA SUBPART F EXCAVATIONS AND TRENCHES REQUIREMENTS. ALL EARTHWORK SHALL SHALL BE STAGGERED. BE PERFORMED IN STRICT ACCORDANCE WITH APPLICABLE LAW, INCLUDING LOCAL 5. HOOK BARS AT OPENINGS. ORDINANCES, WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRIES TITLE 296, 6. NO WELDING OF REINFORCING BARS SHALL BE PERMITTED, UNLESS APPROVAL IN WASHINGTON ADMINISTRATIVE CODE REQUIREMENTS, AND APPLICABLE OSHA WRITING IS OBTAINED BY THE ENGINEER PRIOR TO CONSTRUCTION. REQUIREMENTS. 7. DIMENSIONS TO REINFORCING ARE TO BAR CENTERLINES, UNLESS NOTED OTHERWISE 8 SPECIAL INSPECTIONS AND STRUCTURAL OBSERVATIONS BAR COVER IS CLEAR DISTANCE BETWEEN THE BAR AND THE CONCRETE SURFACE. 1. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 48-HOURS BEFORE PLACEMENT OF UNLESS NOTED OR SHOWN OTHERWISE BAR COVER FOR REINFORCING STEEL SHALL BE AS REINFORCING STEEL AND CONCRETE SO THAT THE SUBGRADE OF EXCAVATIONS MAY BE FOLLOWS: INSPECTED BY THE GEOTECHNICAL ENGINEER. 2. THE GEOTECHNICAL ENGINEER SHALL VERIFY BACKFILL MATERIAL AND BACKFILLING FOOTINGS AND BASE SLABS PROCEDURES AND PROVIDE SOIL COMPACTION TESTS. FORMED SURFACES AND BOTTOMS ON CONCRETE WORK MAT 2-INCH 3. STRUCTURAL OBSERVATION SHALL BE PROVIDED BY THE DESIGN ENGINEER(S) OF BOTTOMS AND SIDES IN CONTACT WITH EARTH 3-INCH RECORD OR THEIR AUTHORIZED REPRESENTATIVES IN ACCORDANCE WITH UBC 97, SECTION SUSPENDED SLABS: 1702. STRUCTURAL OBSERVATION SHALL CONSIST OF SITE VISITS AT INTERVALS FORMED SURFACES EXPOSED TO EARTH, WATER OR WEATHER 2-INCH APPROPRIATE TO THE STAGE OF CONSTRUCTION TO OBSERVE CONSTRUCTION IN PROGRESS TOP AND BOTTOM BARS DRY CONDITIONS 1-INCH AND REVIEW OF TESTING AND INSPECTION REPORTS FOR GENERAL COMPLIANCE WITH THE BEAMS AND COLUMNS: CONSTRUCTION DOCUMENTS RELATING TO THE STRUCTURAL WORK AND THE DRY CONDITIONS: 7 NONSTRUCTURAL COMPONENTS AND EQUIPMENT ANCHORAGE. STIRRUPS, SPIRALS AND TIES 1 1/2-INCH 4. SPECIAL INSPECTION IN ACCORDANCE WITH UBC 97, SECTION 1701, SHALL BE REQUIRED PRINCIPAL REINFORCEMENT 2-INCH FOR THE FOLLOWING TYPES OF WORK. EXPOSED TO EARTH, WATER OR WEATHER: STIRRUPS, SPIRALS AND TIES 2-INCH CONCRETE (f'c EQUAL TO 2,500 PSI OR GREATER, EXCEPT SITE WORK CONCRETE) PRINCIPAL REINFORCEMENT 2 1/2-INCH * PLACING OF REINFORCING STEEL WALLS * TAKING OF TEST SPECIMENS LESS THAN 12-INCHES THICK 1 1/2-INCH * PLACING OF CONCRETE 12 INCHES OR OVER IN THICKNESS 2 1/2-INCH BOLTS INSTALLED IN CONCRETE * PRIOR TO AND DURING THE PLACEMENT OF CONCRETE AROUND BOLTS * INSTALLATION OF EXPANSION ANCHORS OR ADHESIVE ANCHORS CONCRETE STRUCTURAL WELDING 1. CONCRETE FOR ALL WORK SHOWN ON STRUCTURAL DRAWINGS SHALL BE TYPE "B" OR "D" 6 DURING THE WELDING OF ANY MEMBER OR CONNECTION EXCEPT THOSE ITEMS AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,500 PSI UNLESS OTHERWISE SPECIFIED. CEMENT SHALL BE ASTM C150, TYPE 11 FOR ALL STRUCTURES. SPECIFICALLY NOTED IN THE CODE. * DURING THE WELDING OF REINFORCING STEEL 2. CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318 (LATEST EDITION) INCLUDING BAR BENDS AND HOOKS, UNLESS DETAILED OTHERWISE. HIGH STRENGTH BOLTING 3. SUBMIT CONCRETE AND MASONRY LIFT DRAWINGS SHOWING 1HE LOCATION OF * THE INSPECTION OF HIGH -STRENGTH A325 AND A490 BOLTS SHALL BE IN CONSTRUCTION JOINTS, WATERSTOPS AND OTHER TYPES OF JOINTS OTHER THAN SPECIFIED ACCORDANCE WITH THE STANDARDS ADOPTED AS PART OF THE UBC, OR SHOWN ON THE DRAWINGS FOR FAVORABLE REVIEW BY THE ENGINEER BEFORE START APPROVED NATIONALLY RECOGNIZED STANDARDS. OF WORK ON FORMS, REINFORCING STEEL OR PLACING CONCRETE. ANY ADDITIONAL STRUCTURAL MASONRY VERTICAL OR HORIZONTAL CONSTRUCTION JOINTS SHALL HAVE A STANDARD KEYWAY AND * PREPARATION AND TAKING OF PRISMS OR TEST SPECIMENS SHALL BE FAVORABLY REVIEWED BY THE ENGINEER. REFER TO SPECIFICATIONS AND * PLACING OF CLOSED -END MASONRY OR THE START OF PLACING OPEN-END MASONRY. TYPICAL DETAILS FOR ADDITIONAL INFORMATION. CONSTRUCTION JOINTS SHALL BE * PLACEMENT OF REINFORCING STEEL ROUGHENED TO 1/4-INCH AMPLITUDE. 5 * INSPECTION OF GROUT SPACE 4. OPENINGS, PIPE SLEEVES, CONDUITS, INSERTS AND OTHER EMBEDDED ITEMS SHALL BE * IMMEDIATELY PRIOR TO CLOSING OF CLEANOUTS IN PLACE BEFORE CONCRETE IS PLACED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO * DURING ALL GROUTING OPERATIONS COORDINATE ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, LANDSCAPING, HVAC, PLUMBING, INSTRUMENTATION AND OTHER PLANS FOR ITEMS REQUIRING SLEEVES AND EMBEDMENTS IN CONCRETE WHICH ARE NOT INDICATED OR SHOWN ON STRUCTURAL SOIL AND FOUNDATIONS DRAWINGS. NO PIPES OR SLEEVES SHALL PASS THROUGH STRUCTURAL MEMBERS 1. GEOTECHNICAL INVESTIGATIONS FOR DESIGN PURPOSES FOR THIS PROJECT WERE MADE (UNLESS SHOWN ON STRUCTURAL DRAWINGS). COORDINATE WITH EQUIPMENT FOR THE CITY OF RENTON BY ECONOMIC AND ENGINEERING SERVICES, INC. AND MANUFACTURERS DRAWINGS FOR ANCHORING DEVICES. ZIPPER ZEMAN ASSOCIATES IN REPORTS DATED DECEMBER 21, 2001 AND APRIL 23, 5. UNLESS OTHERWISE NOTED, ALL EXPOSED EDGES AND CORNERS SHALL BE CHAMFERED 2002, RESPECTIVELY. 3/4-INCH. INTERIOR FLOOR SLABS AND EXTERIOR SIDEWALKS SHALL HAVE TOOLED 2. IN ACCORDANCE WITH THE UBC CHAPTER 18 THE SOILS IN THE PROJECT AREA ARE 3/8-INCH RADIUS CONSTRUCTION JOINT. GENERALLY CLASSIFIED AS MEDIUM DENSE, SILTY SAND UNDERLAIN BY MEDIUM STIFF, 6. EACH FACE CONCRETE SHALL BE REINFORCED A MINIMUM OF NO. 5 BARS AT 4 SLIGHTLY SANDY, SILTY CLAY. 12-INCHES EACH WAY. 3. THE DESIGN BEARING CAPACITY OF THE SOILS IS 3,000 PSF FOR FOOTINGS. 7. ENCASE IN CONCRETE ALL PIPES AND CONDUITS UNDER CONCRETE SLABS AND BEARING CAPACITY OF SOILS ARE FOR DEAD AND LIVE LOADS FOR FOUNDATIONS AND FOOTINGS. MAY BE INCREASED BY ONE-THIRD FOR SEISMIC AND WIND LOADS. 4. SOIL SHALL BE EXCAVATED TO THE ELEVATIONS INDICATED ON THE DRAWINGS FOR MASONRY FOUNDATIONS. THE SUBGRADE SHALL BE PREPARED AS INDICATED ON THE DRAWINGS 1. CONCRETE MASONRY UNITS SHALL BE OF THE LIGHT WEIGHT CLASSIFICATION AND AND SPECIFICATIONS AND APPROVED BY THE GEOTECHNICAL ENGINEER. EXCAVATED SHALL CONFORM TO ASTM C90, GRADE N, TYPE 1. MINIMUM COMPRESSIVE STRENGTH OF MATERIAL SHALL BE REPLACED WITH STRUCTURAL FILL AS SHOWN ON THE DRAWINGS. UNITS OF 1,900 PSI WHEN AIR CURED FOR 28-DAYS. THE TOTAL MASONRY ASSEMBLAGE FOUNDATIONS SHALL BE CONSTRUCTED AGAINST UNDISTURBED NATIVE COMPETENT SHALL HAVE A COMPRESSIVE STRENGTH EQUAL TO 1,500 PSI AT 28-DAYS. MATERIAL OR COMPACTED STRUCTURAL FILL. 2. MORTAR AND GROUT SHALL COMPLY WITH THE PROVISIONS OF THE 1997 UNIFORM BUILDING CODE, SECTION 2103. 3 LOADING CRITERIA 3. MASONRY MORTAR SHALL CONFORM TO ASTM C270, TYPE S. MORTAR SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS. 1. MINIMUM LOADING REQUIREMENTS PER CHAPTER 16 OF THE 1997 UNIFORM BUILDING 4. ALL CELLS IN MASONRY WALLS SHALL BE FILLED WITH GROUT. GROUT SHALL HAVE A CODE INCLUDING LATEST REVISION. 28-DAY MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI. 2. DEAD LOAD: AS CALCULATED 3. LIVE LOADS: STRUCTURAL STEEL * CONCRETE VAULTS AND COVERS AASHTO HS20-44 1. UNLESS NOTED OTHERWISE, STRUCTURAL STEEL SHALL CONFORM TO ASTM A36. * FIXED STAIRWAYS 100 PSF UNIFORM, 1,000 LBS POINT STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B. * GRATING AND CHECKERED PLATE 150 PSF UNIFORM, 1,000 LBS POINT * ACCESS HATCHES AS NOTED 2. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED BY AN AISC CERTIFIED * SIDEWALKS AND DRIVEWAYS 300 PSF UNIFORM FABRICATOR IN CONFORMANCE WITH THE LATEST AISC SPECIFICATION PARTS 1 THRU 4 * UNRESTRICTED VEHICULAR ACCESS AASHTO HS20-44 AND THE "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS". 2 * ELEVATED SLABS AND WALKWAYS 100 PSF UNIFORM 3. CONNECTIONS AND BOLTS SHALL CONFORM TO THE AISC ALLOWABLE STRESS * HANDRAILS, GUARDRAILS AND STAIRRAILS 20 PLF AT TOP RAIL DESIGN SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. * LATERAL EARTH PRESSURE (AT -REST) 90 PCF (UNDRAINED) CONNECTIONS SHALL USE ASTM A325N BOLTS UNLESS NOTED OTHERWISE. 4. WELD ELECTRODES SHALL CONFORM TO AWS A5.1 OR A5.5 E70XX ELECTRODES. 4. WIND LOAD: WELDING SHALL BE DONE BY CERTIFIED WELDERS. WELDING SHALL USE ONLY * IMPORTANCE FACTOR, Iw 1.15 APPROVED ELECTRODES. WELDING SHALL CONFORM TO THE PROVISIONS OF THE * BASIC WIND SPEED 80 MPH LATEST STRUCTURAL WELDING CODE (AWS D1.1). * EXPOSURE C 5. UNLESS NOTED OTHERWISE, STRUCTURAL STEEL COMPONENTS AND CONNECTIONS 5. ROOF SNOW LOAD: 26 PSF SHALL BE PAINTED OR PROTECTIVE COATED IN ACCORDANCE WITH THE SPECIFICATIONS. SURVEYED: SCALE: AS SHOWN DESIGNED: SJ VERTICAL: NAVD 1988 G I H I I I J I K L M I N 1 0 1 P STRUCTURAL ABBREVIATIONS J T JOINT MFR MANUFACTURER PT PRESSURE TREATED SYM SYMMETRICAL & AND APA AMERICAN PLYWOOD COL COLUMN EXT EXTERIOR MIN MINIMUM @ AT ASSOCIATION CONC CONCRETE KIP 1,000 POUNDS MISC MISCELLANEOUS R, RAID RADIUS T/ TOP OF # NUMBER APROX APPROXIMATE CONST CONSTRUCTION (F) FUTURE KSI KIPS PER SQUARE INCH MTL METAL REINF REINFORCING, -MENT T&B TOP AND BOTTOM 0 DIAMETER ARCH ARCHITECTURAL CONT CONTINUOUS FD FLOOR DRAIN REQ'D REQUIRED TS STRUCTURAL TUBING ASTM AMERICAN SOCIETY OF FF FINISH FLOOR L, L ANGLE (N) NEW TYP TYPICAL 10 AASHTO AMERICAN ASSOCIATION TESTING MATERIALS DBL DOUBLE FIN FINISH LB(S) POUND(S) NIC NOT IN CONTRACT SCH SCHEDULE OF STATE HIGHWAY AWS AMERICAN WELDING SOCIETY DIA DIAMETER FLR FLOOR LB/SF POUND(S) PER SQUARE FOOT NO NUMBER SF SQUARE FOOT UBC UNIFORM BUILDING CODE TRANSPORTATION OFFICIALS DIM DIMENSION FRP FIBERGLASS LL LIVE LOAD NOM NOMINAL SHT SHEET UON UNLESS OTHERWISE NOTED AB ANCHOR BOLT B/ BOTTOM OF DL DEAD LOAD REINFORCED PLASTIC LLH LONG LEG HORIZONTAL NS NEAR SIDE SIM SIMILAR AGGREGATE BASE BLDG BUILDING DN DOWN FT FOOT, FEET LLV LONG LEG VERTICAL NSG NON -SHRINK GROUT SLBB SHORT LEGS BACK-TO-BACK VER T VERTICAL ACI AMERICAN CONCRETE INSTITUTE BM BEAM DWG(S) DRAWING(S) FTG FOOTING LLBB LONG LEG BACK-TO-BACK NTS NOT TO SCALE SLH SHORT LEG HORIZONTAL VIF VERIFY IN FIELD ADDIT ADDITIONAL BM-1 BEAM MEMBER 1 LONGIT LONGITUDINAL SLV SHORT LEG VERTICAL ADJ ADJACENT, ADJUSTABLE BOT BOTTOM (E) EXISTING GA GAGE, GAUGE LT LIGHT OC ON CENTERS SPEC(S) SPECIFICATION(S) W/ WITH AISC AMERICAN INSTITUTE OF BTWN BETWEEN EA EACH GALV GALVANIZED LW LIGHT WEIGHT OD OUTSIDE DIAMTER SQ SQUARE W/O WITHOUT STEEL CONSTRUCTION EF EACH FACE GLB GLULAM BEAM OH OPPOSITE HAND, OVERHEAD SS STAINLESS STEEL W WIDE FLANGE AISI AMERICAN IRON AND C CHANNEL EL ELEVATION MATL MATERIAL OPNG(S) OPENING(S) SSD SATURATED SURFACE DRY WP WORK POINT STEEL INSTITUTE CC,C/C CENTER -TO -CENTER EQ EQUAL HORIZ HORIZONTAL MAX MAXIMUM OPP OPPOSITE STAG STAGGER WT WEIGHT, STRUCTURAL TEE 9 AITC AMERICAN INSTITUTE OF CJ CONSTRUCTION JOINT EQUIP EQUIPMENT HT HEIGHT MB MACHINE BOLT PL PLATE STD STANDARD WALL THICKNESS TIMBER CONSTRUCTION L CENTERLINE ES EACH SIDE MC MOISTURE CONTENT PSF POUND PER SQUARE FOOT STIFF STIFFENER WWF WELDED WIRE FABRIC ALUM ALUMINUM CLR CLEAR EW EACH WAY IN INCH MC MISCELLANEOUS CHANNEL PSI POUND PER SQUARE INCH STL STEEL ALT ALTERNATE CNJ CONTROL JOINT EXP EXPANSION INT INTERIOR MECH MECHANICAL PT(S) POINT(S) STRUC STRUCTURE, -AL YD YARD BAR 1 /4" CONT SPLICE LENGTH FOR REINFORCING BARS IN WALLS & SLABS (INCHES)'... (HEIGHT SAME AS I/4" PROVIDE 3/8"0 COUNTERSUNK n BAR SIZE 1 CONC COVER=1.00 IN. CONC COVER=1.50 IN. CONC COVER=2.00 IN. SOFT INCH I TOP' OTHER TOP' OTHER TOP' OTHER METRIC POUND i #10 #3 17 16 17 16 17 16 #13 #4 23 17 23 1 17 23 17 #16 #5 33 26 28 22 28 22 #19 #6 46 35 34 26 1 34 26 #22 #7 74 57 55 43 49 38 #25 j #8 93 72 70 54 56 i 43 #29 #9 113 87 j 86 66 69 53 #32 #10 137 106 105 81 85 66 #36 #11 162 125 125 97 102 79 CHECKERED PLATE) BOLTS AT 12" O.C. 4 MAX lb CHECKERED PLATE (SEE DWGS 7 CN FOR SIZE &TYPE) soo 1/4" NEOPRENE GASKET CONT ALL 3/16 AROUND IF REQUIRED ON DWG FRAME ANGLE L2 1 /2x2xl /4 CONT ALL AROUND OPENING L3 1 /2x2 1 /2xl /4 CONT AROUND OPENING <:►;0 3/40 CAPSULE ANCHOR @ 2'-0" C.C. STRAP ANCHOR 1/4"x1 1/2" (6" EMBEDMENT) @24"CCMAX NOTES: 1. LAP SPLICE LENGTHS ARE DEPENDENT ON THE FOLLOWING CRITERIA AND ARE IN CONFORMANCE WITH ACI 318-02. NOTIFY THE DESIGN ENGINEER IF THERE ARE ANY DIFFERENCES THAN THE FOLLOWING CRITERIA FOR APPLICABLE CHANGES IN LAP SPLICE LENGTH. 2. LAP SPLICE LENGTHS ARE IN INCHES FOR GRADE 60 REINFORCING IN NORMAL -WEIGHT CONCRETE WITH f'c GREATER THAN OR EQUAL TO 3,000 PSI. 3. CENTER -TO -CENTER SPACING OF REINFORCING SHALL BE GREATER THAN TWICE THE CONCRETE COVER PLUS ONE BAR DIAMETER. MATERIAL SCHEDULE CHECKERED PL. FRAME ANGLE ANCHOR STRAPS BAR ALUMINUM S S S S S S GALV STEEL GALV STEEL STEEL GALV STEEL S S S S S S S S TYPICAL CHECKERED PLATE SUPPORT 4. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 IN. OF CONCRETE CAST BELOW BARS. N.T.S. 5. FOR EPDXY -COATED REINFORCING OR LIGHTWEIGHT AGGREGATE CONCRETE CONSULT THE DESIGN ENGINEER FOR LAP SPLICE LENGTHS. CONCRETE REINFORCEMENT SPLICE TABLE W=2953 5 #3@12" EW, H LESS THAN 8" #4@12" EW, H BETWEEN 8" & 16" #5@12" EW, H MORE THAN 16"- ROUGH CJ I (E) CONC. SLAB #5 DOWEL IN ADHESIVE CAPSULE @ 12" CC - 3/4" CHAMFER 1� VERTICAL EDGES p A D d' . d a 00 a a a � 6" MIN #4 CONT L- SLAB ROUGH CJ } / #3@12" a e dG. #3@12" EW, H LESS THAN 8" #4@12" EW, H BETWEEN 8" & 16" #5@12" EW, H MORE THAN 16" NOTE: ROUGH CONST. JOINT FOR LOCATION AND SIZE, SEE ARCHITECTURAL, MECHANICAL, AND SITE CIVIL DRAWINGS. (N) CONC SLAB TYPICAL CONCRETE CURB (TYP.) N.T.S. #4 (_� AT 12", H MORE THAN 1'-0" 1/4" BAND EDGES (TYP) #4@12" H LESS THAN 16" 1 4" #5@12" H 16" OR MORE ICUT FG TORSHIT PERTINENT PGRATING-FOR VISE SEE FMAX ON EXISTING CONCRETE SLAB ON NEW CONCRETE SLAB NOTES: . s i 1. PLACE ALL EQUIPMENT ON CONCRETE BASES. STRAP ANCHOR FRAME ANGLE L3x2 1 2x1 4 / / (3" BEARING LEG) 2. SEPARATE ALL STEEL SURFACES BEARING ON CONC BY A GROUT LAYER. 1 /4"x1 1 /2 @ 18" CC AND 12" MAX TYPICAL EQUIPMENT PAD FROM CORNER °od. (MIN 2 PER s i • mod•• 1 /4 i N. T.S. MEMBER) :' ,d DIMENSION SHOWN ON PLANS 12 ROUGH j-iI CONSTRUCTION EMBEDDED ANGLE SUPPORT SECTION SECTION A DESIGNATION. 3 6 SHEET SECTION CUT ON SHEET SECTION DRAWN ON DETAIL DESIGNATION DETAIL 3 6 SHEET DETAIL REFERENCED SHEET DETAIL DRAWN ON NOTE: IF THE SHEET DESIGNATIONS DO NOT INCLUDE A LETTER THEY APPEAR ON THE STRUCTURAL DRAWINGS. DRAWN: Si ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy/Jenks CHECKED: DLB Consultants APPROVED: SEM AT FULL SCALE 32001 32nd Avenue South, Suite 100 IF NOT ONE INCH DATUM Federal Way, Washington 98001 RECORD DRAWING 12/05 IF ACCORDINGLY NO. REVISION BY DATE APPR A B C ID E G H b a d d • d d . a JOINT a a. e c a ' a CRUSHED ROCK `D (OPTIONAL) 000a000aoo ,a aaoo�oa�o �oo 6" NOTE: ALL REINF SHOWN SHALL BE #4 @ 12 TYPICAL PIPE AND CONDUIT ENCASEMENT N.T.S. ECONOMIC AND ENGINEERING SERVICES, INC. tt 10900 NE 4th STREET, SUITE 1110 BELLEVUE, WASHINGTON 98005 PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA J K 5/8"0 ADHESIVE ANCHOR b ` AT 18" CC THRUOUT (6" MAX AT ENDS) ii c 4„ FRAME ANGLE L3 1 /2X2 1 /2X1 /4 BOLTED ANGLE SUPPORT MATERIAL SCHEDULE GRATING FRAME ANGLE ANCHOR STRAPS I ADHESIVE ANCHOR GALV STEEL GALV STEEL STEEL GALV STEEL S S S S STEEL S S FIBERGLASS S S STEEL S S TYPICAL GRATING SUPPORT N.T.S. RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND OTHERS. KENNEDY/JENKS CONSULTANTS HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF INFORMATION PROVIDED TO THEM AND DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THESE RECORD DRAWINGS. USERS OF THESE RECORD DRAWINGS ASSUME ALL RISK OF LOSS RESULTING FROM THEIR USE. �- CITY OF RENTON "u Planning/Building/Public Works Dept. MAPLEWOOD WATER TREATMENT AND GOLF COURSE IMPROVEMENTS STRUCTURAL GENERAL NOTES, ABBREVIATIONS AND STANDARD DETAILS L M I N DATE: DEC 2005 PROJECT NO. 3-01-358 REVISION NO. SHT NO. DWG NO. S 1 Wj- 21131513 A A 16 5 4 3 2