HomeMy WebLinkAboutSWP2702959.160) LO 0) N r�- c\j CL REPAIR EXIST. GROUND IN -KIND AS SHOWN ON PLANS (TYP.) REPLACE EXIST. CONC. CURB, AND GU-17ERR !INI KIND TO LIMITS SHOWN ON PLANS (TYP.) EXIST. 249* CLAY STORM PIPE I I 11 1+10XXXXXXX I - H-mi 26'.-0" (APPROX. 15 0-001 12' TRENCH CL SW 7TH STREET SAW CUT LINE —SAW CUT LINE SEE PAYMENT LIMIT NOTE 9' MAX. NOTE: LIMIT OF TRENCH 1' MIN RESTORATION AT SPECIAL PRECAUTIONS GROUND SURFACE TO PROTECT PIPE 2$ 29 SHALL BE NEATLINE TO THIS LEVEL. SAWCUT, TYP. DEPTH TO PIPE CROWN FINISHED VARIES, SEE PLANS GRADE 7 onoaoaoaoI? oa 1 /2" ASPHALT CONC. CLASS 'B' 609 9 6" ASPHALT CONC. CLASS 'B MIN. S 6" CRUSHED SURFACING TOP COURSE CPEP OR 3'-0" PIPE BEDDING DUCTILE IRON SEE SPECIFICATIONS STORM PIPE SEE PAYMENT LIMIT NOTE TYPICAL 12" LATERAL TRENCH SECTION NOT TO SCALE V TA 4 21088 4 'ISTSS AL F-EXPIRM 7-12-2004 CONSULTING ENGINEERS 701 DEXTER AVENUE NORTH SUITE 200 SEATTLE, WASHINGTON 98109 (206) 284-0860 34'-0" (APPROX. 21 -0 00 - TRENCH NOTES 1 36" DIAMETER CPEP STORM PIPE AND TRENCH SECTION. INVERT DEPTH SHOWN AT 8 2. SEE "TYPICAL TRENCH SECTION, 36" STORM PIPE BELOW FOR FURTHER INFORMATION ON TRENCH AND RESTORATION REQUIREMENTS AND PAYMENT LIMITS. 3. SEE "CATCH BASIN OFFSET" DETAIL ON SHEET 26 FOR LOCATION OF FRAME ASSEMBLY. SPECIAL PRECAUTIONS -A TO PROTECT PIPE TO THIS LEVEL. DEPTH TO PIPE CROWN VARIES, SEE PLANS 12 MIN 99 18 - 10' MAX. 2 to 4 - 11' MAX. 36" 6 - 13' MAX. 1' MIN 1' MIN SEE TRENCH NOTE FINISHED GRADE ;A, U CPEP, CONCRETE > OR DUCTILE IRON STORM PIPE SEE PAYMENT LIMIT NOTE 1800 - 4$-0$$ 24" - 51-0 36$0 - 70-0 TYPICAL TRENCH SECTION 18 24", & 36" STORM PIPE NOT TO SCALE NO. REVISION ----2" ASPHALT CONC. CLASS 'B' 6" ASPHALT CONC. CLASS 'B' 6" CRUSHED SURFACING TOP COURSE PIPE BEDDING SEE SPECIFICATIONS jw IZ Iw STATION 30+00 TYPICAL STREET CROSS-SECTION FOR 36" DIAMETER STORM PIPE SCALE: APPROX. 1"=3' SEE PAYMENT LIMIT NOTE 18' MAX. SEE TRENCH NOTE 1w; TI, �11 IIIIIIII 10 SEE PAYMENT LIMIT NOTE TYPICAL 60" TRENCH SECTION NOT TO SCALE "NTIA001 0 APP 8 lb ROCV, T] 33 ONE INCH AT FULL IF NOT ONE INCH SCALE ACCORDINGLY VERMAU NAVD IM NAD im/1"i DATUM 1' MIN 2" ASPHALT CONC. CLASS 'B' 6 ASP HALT CONC. CLASS 'B' 6" CRUSHED SURFACING TOP COURSE PIPE BEDDING SEE SPECIFICATIONS -XA c c T `�a &iT -Tol -j (Iji-T pe RECOMMENDED FOR APPROVAL By Datel,3/A/t:�- BY0 --- Datel- By, ---------------- Datei -------- Byi---------------- Datet -------- 1 mmannamm 2/20/04_ CITY OF S.W. 7TH STREET DRAINAGE IMPROVEMENT PROJECT FIELDSOM ML RENTON PHASE 2 - LIND AVE. SW. TO MORRIS AVE. S. PAGE: MWING W. Planning/Building/Public Works Dept. TYPICAL STREET CROSS SECTION - STATION 30+00 STORM DRAINAGE TRENCH SECTIONS SHW- 24 OF. 27 SCA, fiNED MAY 0 12006