EXIST C.B.
RIM = 279.09
d
F.L. = 275.09
W
z
8
0.4
G-I
EXIST C.B.
RIM = 278.65
F.L. = 274.45
W
W
d
EXIST 8" WAT LINE -�
W
ON E. SIDE OF CL
APROX. LOC.
0
0
Q
N
U
00
N
J
Q
O
N
o
Z
OD
0
Ln
N�
Cr
Uj
mU
__j
O J
N
a�
6' WOOD FENCE
5'f SIDEWALK
3' 1 1 "f GRASS STRII
VERTICAL CURL
31 ' 6"+- STREET
J
xd
O
= 0
=
II
Z
o
Z O
�og�
r Z J
a � q
�X
W
Z
Z
w
a
Z
J
Z
LJ
Q
Q
U
U
N
O
G
U Q
p
p
p Q
O
CD�
O
O L�.I
I
I
I
Q
0
0
o m
Q
�
�
�
Z
Z
L j
LJ
LIJ
Z
2
:2
W
:2
:2
O
O
U
U
~
W
W
0:�
LLJ d
W
i
W
Z
0
U)
O
O
}
1-
5;
N
U
U
w
pZ
U
N
O
N
I1.I
w
W
�
m
m
w
w
w
z
S.E. 1/4, SEC. 5, T. 23N, R. 05E5 W,M.
\ T
m
Z
m
m
D
m
m
z
—I
10' INGRESS EGRESS & UTILITIES
EASEMENT -ACCESS PARCEL #334390-1850-09
0850
MULTI
15' BSBL FOR STORY
UTIL. EASEMENT HOUSE
EDGE DF
0\
n �
S S
tit o
0
4" R&F-TYP — —
R MOVE
►� SD � CO
288 X C\/
1Z
REMOVE
D
P'4VEMENr
w
0
0
SEE SHEET 1 FOR
ESM'T DESCRIPT.S
Z_
o (2 5)
n
zI
�SUI I m
OI
U
REMOVE
REMOVE V
`00
V
/__2 5' 25'
W A1-K
STA 20+53.6 27' LT CONC. v 0O
3/4" DOMESTIC WATER
SERVICE METER (TYP.) EX WAT METER o
OT 1 z STA 21+46 27 LT
-SEE DETAIL SHT 10 (RELOCATE) 3/4" DOMESTIC WATER
GUY WIRE SERVICE METER (TYP.) 25
PP D -SEE DETAIL SHT 10
EX SSS-TYP
TR n 0i PROP SSS-TYP c�
E- A U V V /-1 I I
VERTICAL DATUM _NOTE:
ALL CONTOUR ELEVATIONS IN
THIS DRAWING WERE BASED ON THE RIM OF SANITARY SEWER MANHOLE
NO.
19 PER CITY OF RENTON
AT THE INTERSECTION OF NE
16TH STREET AND MONTEREY COURT NE, ELEVATION = 300.78 PER CITY
OF
RENTON AS-BUILTS,
SHEET 9 OF 12, DATED: 4-1-70.
THE VERTICAL USED BY THE
CITY OF RENTON FOR THE CONSTRUCTION OF THE SANITARY SEWER LINE
TO
THE NORTHERN PORTION OF
THIS SITE IS BASED UPON NAVD 1988 WHICH INDICATES THAT THE ELEVATION FOR THE ABOVE MENTIONED
SANITARY SEWER RIM
IS 304.54. CONTRACTOR IS
TO BE AWARE THAT THE VERTICAL DATUM FOR THIS PLAN SET NEEDS TO
BE
ADJUSTED TO CONFORM
WITH NAVD 1988 WHEN THE
AS-BUILTS ARE PREPARED FOR SUBMITTAL TO THE CITY OF RENTON.
Ga
N
W
O
25
STA 13+41.8 9.5' RT
3/4" DOMESTIC WATER
SERVICE METER (TYP.)
FOR LOT 3
-SEE DETAIL SHT 10
STA 13+41.8 11.5' RT
3/4" DOMESTIC WATER
SERVICE METER (TYP.)
FOR LOT 4
-SEE DETAIL SHT 10
EX 6" WAT LINE
AVOID CUTTING UNDERGROUND
UTILITY LINES. IT'S COSTLY!
Call
before you
Djg.
WATER NOTES:
1. WATER LINE DISTANCES SHOWN ON THESE PLANS ARE FROM
CENTER OF FITTING TO CENTER OF FITTING
2. CONTRACTOR SHALL POTHOLE EXISTING UTILITIES PRIOR TO CONSTRUCTION TO
VERIFY HORIZONTAL AND VERTICAL LOCATIONS. CONTRACTOR TO CONTACT
ENGINEER CONCERNING ANY POTENTIAL CONFLICTS.
3. FOR LOTS 3 & 4, CONTRACTOR TO EXTEND 3/4" WATER SERVICE TO LOCATION
OUTSIDE OF PAVING PRIOR TO PAVING ACCESS EASEMENT.
4. ALL TRENCHING AND STREET OVERLAYS SHALL BE PER THE CURRENT CITY OF
RENTON TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS.
SEE DETAIL ON SHEET 4.
5. LOCATIONS OF EXISTING WATER LINES ALONG
NE 16TH ST, MONTEREY CT. NE, AND MONTEREY
AVE NE ARE TAKEN FROM CITY OF RENTON WATER FACILITIES MAP
#D4 - E 1 /2 OF S5, T23N, R5E.
6. LOCATIONS OF EXISTING WATER VALVES SHOWN ON
PLAN ARE FROM FIELD SURVEY.
7. EXISTING FIRE HYDRANT MUST BE EITHER REBUILT TO THE APPROVAL OF THE CITY
OR REPLACED WITH A NEW HYDRANT. HYDRANT TO BE PROVIDED WITH A
QUICK DISCONNECT "STORTZ" FITTING.
In
GRAPHIC SCALE
20 0 10 20 40
NOTE:
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1-800-424-5555
( IN FEET)
1 inch = 20 ft.
80
RECOMMENDED
FOR APPROVAL
BY K�%I/fib
BY
BY
dam•
�Q�
'
4..
ss�ONA
L
EXPIRES
5-13-07
UNDERGROUND SERVICE (USA)
STAMP NOT VALID UNLESS SIGNED AND DATED
cA=w-211.1.o'L ED