Loading...
HomeMy WebLinkAboutWTR2703086.12 NOTES CITY OWNED AND MAINTAINED PRIVATELY OWNED AND MAINTAINED 1. MAIN LINE TEE (MJxFL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY SHALL Z MAXIMUM PIPE LENGTH FROM PROPERTY LINE NOT BE MORE THAN 50 FEET TO THE BUILDING). TO DDCVA MUST NOT EXCEED 50 FEET 2. BRANCH VALVE (FLXMJ) WITH VALVE BOX AND COVER. o BUILDING WALL 3 ANDS CONCRETE TITHRUSLE OTN BLOCKPIPE S4PER INCH NFPIAIMUMAND) AWWAALL PSTANDARDS.IPES AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS O a ® 1 p N d�arti 4. POST INDICATOR VALVE (MJ) WITH TAMPER SWITCH. �,,'•t� ® O5 5. (2) 90- BENDS (FLxFL) WITH FLANGED DUCTILE IRON SPOOL. O 0 DCVA MUST BE INSTALLED IMMEDIATELY 6. 18" LONG SPOOL FLxPE . AFTER PIPE PENETRATION THROUGH ( ) O BUILDING FLOOR SLAB A RIGHT -OF -ENTRY LLJ 7. FLANGE COUPLING ADAPTER. Z 5' MAX 4 CONCRETE BOLLARDS 0 MUST BE GRANTED TO THE CITY OF O9 O O < RENTON FOR INSPECTION FOR Y INSPECTION OF THE DDCVA AND METER. 8. APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF W o lab BACKFLOW PREVENTION DEVICES). BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCHES ABOVE FLOOR LEVEL AND O7 W 3 64?3 NOT HIGHER THAN 5 FEET MAXIMUM. INSTALL THREE CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER 0 10 z DDVCA. U O PERIMETERS OF MIN CLEARANCES 3 9. O.S. AND Y VALVES TO BE RESILIENT SEALED WITH TAPER SWITCHES. ADD WIRING IN ACCORDANCE WITH L&I. J ® o Q T PAINTED 0 BE AIN ED ON FLOOR IN 10. METERED 3/4 INCH BYPASS DCVA -BYPASS METER SHALL BE A 3/4 INCH "SENSUS-ECR" SR POSITIVE DISPLACEMENT WHITE ENAMEL PAINT STRIPE RECOMMENDED FOR APPROVAL METER EQUIPPED WITH A REMOTE READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL. z WITH 2 INCH STENCILED BLACK o LETTERS TO SAY : "DO NOT 11. SWING TYPE GRTAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULT. ° O BLOCK ACCESS" 0 000 12. 4"x4"x6" BULL, ELBOW, THREADED. 11 O 13. UL LISTED FIRE DEPARTMENT CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET OF A PUBLIC FIRE HYDRANT. 13 12 7 WASTEWATER UTILITY DATE AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO THE CITY OF RENTON WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO TO ACTIVATION OF NEW WATER LINE. INSTALL BRASS PLUGS AT ALL TEST COCKS. cn SURFACE WATER UTILITY DA TE w 24" Z 48„ w r d N N r _j1 bA' is 4'/ 361 03 WATER UTILITY DA TE orx- J 4_L_ 24 INCH MIN m5 FEET MAXIMUM o STY ER VICES DIRECTOR DA TE FINISH FLOOR LEVEL rl " ELEVATION VIEW OF DDCVA - (� 47 WCV Ass nft and 47 Standpoe W' (2) 2-1/2' Nozzel PUNT ¢NA NC SERVICES DIRECTOR- DATE Y,g C. SURVEYED: SCALE: VECADATE: �F - HORI ONTAL NAD 1983/1991 4-24-03 , DESIGNED: AS SHOWN •, CITY OF RENTON PAVILION C O U G H LI N PO RT E R LU N D E E N €� �I° JAS FIELDBOOK: y° DRAWN: SAS RENTON CITY OF RENTON PAGE. A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWING NO: ONE INCH DATUM 217 PINE STREET - SUITE 300 P: 206'343-0460 l 265 4 CHECKED: NOT ONE INCH DETAILS p �'��� ���' � �As AT FULL SCALE Planning/Building/Public Works Dept. SEATTLE, WA 98 o I F: 206 343-569 I ��SSIpNAL ��'03 NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY rs-EET! 6 OFs 6 EXPIRES 01/23/2004 '2 /-) ', "'V - ?0 SCANNED NOV 7 200