HomeMy WebLinkAboutWTR2703142.10O 2 0 3 15 0 Ln C13 RIM 95.26 IF R Q d ( 1 ? "(- Ni) CB RIM 106.87 IE 99.7(12"C N) it n rN -7 / i n I I /- i A iN C13 RIM 105.56 IE 103.0(12"C E) MAINTAIN 4 MIN. SEPARATION C13 RIM 95.90 MAINTAIN EX. DITCH 6, PER DE IF 94.4(12"C N) TAIL (TYPICAL' WET TAP CUT IN: IF: 94.4(6"C S) 63 76 STA. 44+13 RT 76 IE 94.3(12 C S) REMOVE & REPLACE EX. SERVICE STA. 42+83, RT. 34 W/ NEW 3/4 PER SERVICE P) WITH NEW SETTER & METER 8 x6" TEE (MJxFL) BOX & CONNECT TO EX. PRIVATE 6" GV (FLxMJ) PIPING (TYPICAL) CONCRETE BLOCK STA. 42+83, RT. 73' # 1519 FIRE HYDRANT ASSEMBLY SSMH RIM 104 Q. CUT & CAP .08T a EX. 6 WATER IE 95.2 (8 " C N, S E) O �, AFTER TIE—IN WET 16 1p$ x8" WET TAPPING TEE (MJxFL) 8 GV (FLxMJ) 8 SPOOL PIECE CONCRETE BLOCK SEE CONNECTION DETAIL 11 12 TALBOT Nu. -ONC STA. 43+79, RT. 70' UTILIT-Y Rk- WALL. 8 x8" TEE (MJxFL) (3) 8" GV (FLxMJ) #1525 _j CB 110.17 CONCRETE BLOCK TALBOT RD. S RIM C13 ssm RIM 112.60 NOTE: DEFLECT NEW 8" MAIN IE 108.4(12"C N) RIM 11 1.19 IE 110.6(12"C N) UNDER EX. 6 11 WTR. IE 108.4(12"C S) IE 102.3 IE 110.5(12"C W) CUT & CAP EX. 6" WTR (8 C N & S) AFTER TIE—IN CONNECTION ........... ........... ............... ........ ........ ......... ...... ........... ............ ...... ........ ............................................ ............................... .................................................... StA :HORIZ. 1:20' STA. 43+45, RT. 34' -EX. 16" WATER: PRV VAULT Iwo. DEFLECTION 110 llo� -VERT. 1:5 BEGIN VERT... PI.P.E.... � .......... I ....... ...... ........ ................... .............. ... ................. ......... ...... .. .... .... . .............. ........ STA. 42+83. RT. '34' Wp,�ER 8 F.H^ TEE 105* ...... ...... ......... .. .......... ... ....... ..... ....................... ........ 3 FT. BURY (TYPICAL) 100' 6 ........ ... .... ..... ... ........... 1.0.5.. ........ .......... ....... . ..... ------ ....................... ....... AD STA. 44+13, RT-_ 76 . 12SD5 2- 0 95' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 S B3 8 D WET TAP- TIE—IN, CONNECTION .95 .......... ....... ...... .............. ............................. ------- MAINTAIN- MIN. 9. VERT.: n M SEPARATION MAINTAIN MIN.- 9 VERT. 90 - ............ ...... ............ ........ ...... ........... ............... ......... ....... ........ .................. .................. -------- ----------------------------------- ......... ....... SEPARATION, 8"_- SD 0 .85 85.----- - ................................ ...... .................. SUN&= CKLI AS —BUILT INFORMATION PROVIDED Ba" I BY FIELD NOTES MEASUREMENTS O RH 1"=20' CITY OF 1/15/04 RLM WATER MAIN REPLACEMENT ONE sm Feumm. RLM REN TON TALBOT HILL PAM � ft I T_ AG [—is f t"am Planning/Building/Public Works Dept. PHASE 1 (AS -BUILT) W-3142 r wr ow NO. REVISION BY I DATE I APPR w" sm3m. OF. LH 10 14 SCANNED OCT 0 8 .2mft � � ; Vv _ �/�`' of? � W 3 1 �" � O c 17 UQ -0 rl 2! r) m