HomeMy WebLinkAboutWTR2703161.30 M J in 0 a w LE X 0 0 Lii M t` z J u_ J = U 2 = -a = W (= z � o ZW O iZ z a = o = N N ElW v�i z v, o o v g 11 Q O O O LLJ r do Q� m 0 > In Ll.I z ry 0 a U Q O tZ m J f- Cn a L (nn f X eee� FLUSH WITH FINISH GRADE (TYPICAL) UNION (TYPICAL) 30' MIN. t 4 TO CITY METER F-1 TAPPING TEE (MJxFL) TAPPING GATE VALVE (FL XMJ) TEMPORARY PLUG (MJ) WITH 2-INCH TAP AND 2-INCH BLOW -OFF ASSEMBLY CONCRETE BLOCKING PORTION OF THE S.W. 1/4, OF SEC. 3, TWN 23 N., RGE 5 :., W.M. CITY OF RENTON, WASHINGTON 12"-16" CLEARANCE FOR 3/4" TO 2" DCVA, USE FOGTITE CONCRETE METER BOX NO. 2T (17"x28") WITH 3/8" STEEL COVER PLATE METER BOX SHALL BE DOUBLE STACKED. FOR 2-1 /2" TO 3" DCVA, USE UTILITY VAULT CO. MODEL 25TA OR EQUAL. 30" MIN. AFTER TESTING & APPROVAL, PLUG ALL TEST COCKS WITH BRASS PLUGS. 0 TO PRIVATE SYSTEM AFTER FIELD INSTALLATION, DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. 7/8" MINUS GRAVEL 12" MINIMUM TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING PRIOR TO ACTIVATION OF NEW LINE. BELOW GROUND INSTALLATION FOR 3/4" TO 3" DOUBLE CHECK VALVE ASSEMBLIES 2" BEEHIVE STRAINER f 2" OPEN PATTERN, RETURN BEND 2" GALVANIZED IRON PIPE FIELD LOCATE CUT OPENING AS REQUIRED, 1" CLOSE NIPPLE 17"x28" CONCRETE METER BOX WITH 3/8" STEEL DIAMOND AFTER INSTALLATION, GROUT 18" 1" UNION 6" MAX. PLATE COVER EQUAL TO FOG-TITE METER SEAL CO. NO.2 AROUND PIPE. 1" NIPPLE METER BOX. FIELD LOCATE. 1" UNION 2"x 2"x 1" TEE, 1" CLOSE NIPPLE BETWEEN TEE & BEND. 1" 90' ELBOW - 1" BRONZE GATE VALVE, SCREW EQUAL TO RED -WHITE VALVE CORP. FIG NO.280 Z" GALVANIZED IRON PIPE ` COUPLING COPPER TO MALE IRON PIPE -FORD C28-44 OR EQUAL. 18" LONG o 6 o ° 0 0°0 0 1" TYPE "K" SOFT COPPER TUBING 12" MIN. o°off°g00� o o 0 0 0 0° 1" IRON PIPE THREAD CORPORATION STOP WITH o 0 8o °o �0 �� 90' BEND FOR COPPER. FORD TYPE F1000 PACK Jo moo do .0 0,.o.oa JOINT CTS. 1" GALVANIZED IRON PIPE TO FIT 2" CAP WITH 1/8" HOLE 1" 90' ELBOW FOR DRAIN. 1" COMBINATION AIR RELEASE & VACUUM VALVE, WASHED GRAVEL, PASSING SCREWED. APCO NO. 143C OR EQUAL. 1-1/2" AND RETAINED ON 1/4" MESH FOR DRAIN NOTE: AIR AND VACUUM RELEASE VALVE ASSEMBLY SHALL BE INSTALLED AT HIGHEST POINT OF LINE. IF HIGH POINT FALLS IN A LOCATION WHERE ASSEMBLY CANNOT BE INSTALLED, PROVIDE ADDITIONAL DEPTH OF LINE TO CREATE A HIGH POINT AT A LOCATION WHERE ASSEMBLY CAN BE INSTALLED. 1" AIR & VACUUM RELEASE VALVE ASSEMBLY TESTING DETAIL J. n cr NEW D.I. WATER LINE VERTICAL CROSS(MJXFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) WITH 2"TAP & 2" BLOW -OFF TEMPORARY BLOCK DOUDLE STRAP SERVICE CLAMP WITH 1" IPS TAP TO FIT, EQUAL TO MEULLER CO. FINAL CONNECTION DETAIL �- - TEMPORARY 2" GALVANIZED PIPE AND 2" FINISHED GRADE ELEVATION GATE VALVE INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) NE7) __ER MAIN POLYPIG • - n s- - -�- • - VERTICAL CROSS FOR POLYPIGGING STATION: SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJxFL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP AND 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2' PLUG AFTER REMOVAL OF CLEANING "POLY -PIG') ONE BLIND FLANGE ON BOTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN WATER MAIN POLYPIGGING STATION VERTICAL CROSS FOR POLYPIGGING NEW D.I. WATER LINE AFTER ALL CLEANING BY POLYPIG, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTION BY CITY FORCES NOTES: 5. CONTRACTOR SHALL POTHOLE AND VERIFY THE 1. TAPPING TEES SHALL BE MADE OF DUCTILE IRON OR EPDXY- HORIZONTAL AND VERTICAL ALIGNMENT OF EX/STING LINE COATED STEEL. OR STUB AND SHALL START LAYING THE NEW LINE AT 2. NO SIZE ON SIZE TAPS ON CAST-IRON WATER LINES. THE SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EX/STING MAIN. EXISTING STUB. 3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE CITY FORCES WILL PERFORM THE FINAL CONNECTION 4. WET -TAP SHALL BE DONE ONLY BY CITY -APPROVED CONTRACTORS FROM THE WATER LINE TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL WATER CONNECTION DETAIL WET -TAP EXISTING WATER MAIN WATER MAIN 2" CLOSE NIPPLE 2" 90' ELBOW TWO PIECE CAST IRON VALVE BOX EQUAL TO RICH VALVE CO. STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. 2" GALVANIZED IRON PIPE 12" LONG CONCRETE BLOCKING SIZING PROCEDURE A. GENERAL The amount of concrete required to anchor horizontal bends, tees, and dead ends depends on the strength of the soil. The methods of placing concrete to keep the joint accessible is shown in Figure 1. The area in square feet of concrete which must bear against the side of the trench is found by dividing the thrust in pounds shown in Table 1 by the safe bea___ ri�g_lood of the soil as shown in Table 2. B. �BL�6I9 1. The sizing procedure is for horizontal or downward thrust only. 2. Height of the thrust block must be equal to or less than 1/2 the depth from the ground surface to the block base. 3. The thrust block bearing face is approximately rectangular. 4. The concrete blocking shall be as per APWA SYMB6LScification 74-2.N. C. d = Outside Diameter of Pipe in Feet T = Thrust in Pounds at the Fitting (Table 1) SBL = Safe Bearing Load in Pounds/Sq. Ft. (Table 2) h = Depth of Trench in Feet W = Width of Trench in Feet A = Area of Concrete which must bear against the Side of the Trench in Sq. Ft. Hm = Maximum Height of the Thrust Block in feet Dc = Depth of the Concrete Thrust Block to Bearing Surface in Feet Lm = Maximum Length of the Thrust Block in Feet GROUND SUFACE h " d Hm= 2 + BLOCK BASE DC W- D. CALCULATION EQUATIONS 1. Area of Concrete (A) = Thrust (in Pounds _ T Safe Bearing Load (in Pounds/Sq. Ft.) SBL 2. Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet - h 2 - 2 (Width of Trench in Feet) - 3. Depth of Concrete Thrust Block = Outside Diameter of Pipe in Feet) - W-d 2 2 4. Maximum Length of Thrust Block (Lm) = Area of Concrete - A Maximum Height Hm 5. Required Amount of Concrete (Cu. Yd.) = (Height x Depth x Length) x 0.03704 = (Hm x Lm x Dc) x 0.03704 E. EXAMPLE 1. Problem: Calculation of the amount of concrete required to block a 90' bend in an 8" C.I. water main; the normal operating pressure in the pipe will be 65 psi and the soil condition in the area indicates sand and gravel. 2. Solution: - Maximum testing pressure (See Table 1) = 300 psi. = 0.75 ft. - Outside diameter of 8 pipe = 9.05 in. = 9.05/12 - Go to Table 1: The testing pressure of 300 psi, we see that the thrust on a 90' bend is 21,360 pounds. CONCRETE DEAD MAN BLOCKING WITH SHACKLE RODS TO CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED EARTH, SIZE OF BLOCK TO BE DETERMINED BASED ON TEST PRESSURE OF WATER LINE AND SOIL CHARACTERISTICS. CAST IRON CAP OR PLUG WITH 2" IPS TAP SHALL BE A ROCKWELL 482 END CAP COUPLING. 2" GALVANIZED IRON PIPE AS REQUIRED. 2" GALVANIZED IRON PIPE, 12" LONG. PLAN VALVE NUT EXTENSION IF REQUIRED (SEE DWG BR46 / PAGE B090) INSTALL 2" 90' ELBOW, SCREWED 2" PLUG, SCREWED - 18' 2" GALVANIZED IRON PIPE AS REQUIRED. 2" GATE VALVE, SCREWED i- INSTALL 2" 90' ELBOW, SCREWED 2" GALVANIZED IRON PIPE AS REQUIRED. ELEVATION TEMPORARY 2" BLOWOFF ASSEMBLY - Go to Table 2: Table 2 gives the safe bearing load for sand and gravel: 3,000 lbs./sq. ft. - Go to Figure 1: figure 1 indicates the position of the concrete for blocking the 90' bend. - Go to the specifications of the project and find depth of trench (h) = 4 feet - Width of trench 3 feet With the above assembled information, we proceed to the final calculations: - Area of Concrete (A) = Thrust = 21.3fi0 = 7.12 sq ft. Safe Bearing Load 3,000 - Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet 2 = h _ 4 = 2.0 ft. 2 2 - Depth of Concrete Thrust Block (Dc) Width of Trench in Feet (W) - Outside Diameter of Pipe (d) 2 = 3- 0.75 = 1.13ft. 2 - Maximum Length of Thrust Block (Lm) = Area of Concrete Height of Concrete = A __ 7.12 = 3.56 ft. Hm 2.0 - Required Amount of Concrete = (Height x Depth x Length) x 0.03704 = (Hm x Lm x Dc) x 0.03704 = (2.0 x 3.56 x 1.13) x 0.03704 = 0.30 cu. yd. TABLE 1 Size Pressure PSI Thrust at Fittings in Pounds Tees 90' 45' 22-1/2 11-1/4 Dead Ends Bend Bend Bend Bend 3" 300 2,120 3,000 1.630 830 430 4" 300 3,780 5,370 2,910 1,470 750 6" 300 8,500 12,000 6,510 3,320 1,700 8" 300 15,100 21,360 11,550 5,880 3,020 10: 275 21,620 30.570 16,540 8,430 4,330 12" 250 33,930 48,000 25.950 13,260 6,780 14" 250 46,200 65,370 35,340 18,030 9,240 16 225 45,250 64,000 34,620 17,650 9,050 18" 200 50,900 72,000 38,940 19.860 10,180 20 200 62,840 88,900 48,080 24.520 12.560 24" 200 90,480 127,980 69,200 35,320 18,100 30" 200 141.370 199,960 108,150 55,140 28,280 36' 200 203.580 287,950 155.740 79,400 40,720 TABLE 2 Safe Bearing Loads in Lb./Sa. Ft. The safe bearing loods given in the following table are for horizontal thrusts when the depth of cover over the pipe exceeds 2 feet. Safe Bearing Load SQL Lb. per Sq. Ft. *Muck, peat, etc. 0 Soft Clay 1,000 Sand 2,000 Sand and Gravel 3,000 Sand and Gravel Cemented with Clay 4,000 Hord Shale 10,000 *In muck or peat, all thrusts shall be restrained by piles or tie rods to solid foundations or by removal of muck or eat and replacement with ballast of sufficient stability to resist thrusts. Call07NOTE: Or 0 before you EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. t133 Digs IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE STF EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- SSIONAL� 1_800_424-5555 GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN EXPIRES 11/30/04 UNDERGROUND SERVICE (USA) HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES AVOID CUTTING UNDERGROUND NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. UTILITY LINES. IT'S COSTLY CALL BEFORE YOU DIG: 1-800-424-5555. SCANNED MAY 0 12006 14P e`��^'�' o ._Ed& =r CAP 22-1/2- TE E 45°BEND FIGURE 1 90 BEND NOTE: FOR CONVEX VERTICAL BENDS BLOCKING SEE APWA STANDARD PLAN NO. 73. CONCRETE BLOCKING SIZING PROCEDURE Y p ADOPTED CITY OF RENTON ♦ I♦ STANDARD PLANS LST DATE: 12/96 DWG. NAME: BR26 SP PAGE: B085 CHECKED FOR COMPLIANCE RECOMMENDED TO CITY STANDARDS FOR APPROVAL DATE BY DATE BY DATE BY BAXTER M EADOWS DETAILS & NOTES SCANNED 0 0T OR DATE: 3/11/03 FIELDSOOK: PAGE: DRAWING NO- 75-141-WA SHEET: OF: 8 9