Loading...
HomeMy WebLinkAboutWTR2703185.1STTLWAUSG 17 GENERAL NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - SPECIFIED CONTRACTOR PER SCOPE OF WORK SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) OWNER - AT&T WIRELESS SERVICES. 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND PROJECT SPECIFICATIONS. 3. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT. APPURTENANCES. AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. B. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. 9. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 10. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION_ 11. ALL. EXISTING ACTIVE SEWER. WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFELY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING do EXCAVATION. 12. ALL FASTING INACTIVE SEWER, WATER. GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED. PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK. AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 13. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION, 14. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION. SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL 15. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS. SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 16. THE SUB GRADE SHALL. BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. 18. IF NECESSARY. RUBBISH, STUMPS. DEBRIS. STICKS. STONES AND OTHER REFUSE SHALL. BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 19. THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE. 20. SUBCONTRACTOR SHALL. LEAVE PREMISES IN CLEAN CONDITION, DETAIL_ 300 BECHTEL TELECOMMUNICATIONS 12131 113TH AVENUE NE iv KIRKLAND. WASHINGTON 98034 wpP - 2 7 - A/SS 2ooy v� ( rct �Z ecd rA �r�w; PROJECT INFORMATION SCOPE OF WORK: UNMANNED TELECOMMUNICATIONS FACILITY MODIFICATIONS SITE ADDRESS: 12603 82ND AVE SOUTH A - RENTON. WA 98055 • - LATITUDE 47. 29' 24" 9rmZj }A*01(irts LONGITUDE: JURISDICTION: -122' 13' 49- KING COUNTY GL�YtYS �i>1 CURRENT USE: PROPOSED USE: TELECOMMUNICATIONS FACILITY TELECOMMUNICATIONS FACILITY Jf/ /' i AT&T UMTS SEATTLE MARKET AT&T WIRELESS SITE NUMBER: STTLWASG17 SITE NAME: RENTON HILLS I DRAWING INDEX I REVI APPLICABLE BUILDING CODES AND STANDARDS STTLWASGI7-T01 TITLE SHEET - NORTEL UMTS IBTS 0 STTLWASGI7-AO1 POWER, GROUNDING & TELCO PLAN UMTS 18TS (INDOOR) 0 STTLWASGI7-AO2 CONSTRUCTION DETAILS UMTS iBTS (INDOOR) 0 STTLWAS13I7-A03 ANTENNA CONFIGURATION 0 STTLWASGI7-A04 RF NOTES & BILL OF MATERIALS 0 STTLWASGI7-AO5 ANTENNA ELEVATION 0 STTLWASGI7-E01 +24VDC POWER INDOOR SINGLE LINE DIAGRAM 0 STTLWASGI7-EO2 ELECTRICAL DETAILS 0 VICINITY MAP DIRECTIONS: TAKE THE INTERSTATE 405 SOU."d TOWARDS RENTON TO EXIT #4. SUNSET BLVD. NORTH. CONTINUE SOUTH ON SUNSET TO BRONSON NA.`:' NORTH. CONTINUE SOUTH ON BRONSON TO SOUTH 2NO ST. CONTINUING WEST ON S.2ND ST. TURN RIGHT ONTO RAINIER AVE. SOUTH AND LEFT ONTO RENTON AVE. SOUTH. TAKE RENTON TO 128TH ST AND TURN RIGHT ONTO 128TH BACK TO 82ND AVE. SO. TURN LEFT ONTO 82ND TO WATER TOWER SITE. PROJECT ( cLj SITE * S. 126TH PL RENTON MUNICIPAL N AIRPORT S. 128TH ST. S. 132ND ST. AIRPORT WAY S. RENTON AVE. S- S, 2ND ST. SITE NAME: RENTON HILLS AT&T SITE #: STTLWAS0I7 JA 12603 82ND AVE. SOUTH RENTON, WA 98055 a AT&T WIRELESS SERVICES, INC. As sraMne 5 3 SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. BUILDING CODE: [INTERNATIONAL BUILDING CODE (IBC), 2000] ELECTRICAL CODE. [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 - 1999, NATIONAL ELECTRICAL CODE. AS ADOPTED BY AW] b LIGHTNING PROTECTION CODE: (NFPA 780 - 1995, LIGHTNING PROTECTION CODE) w SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING 0 AMERICAN CONCRETE INSTITUTE (ACI) 318. BUILDING CODE REQUIREMENTS FOR STRUCTURAL AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). MANUAL OF STEEL CONSTRUCTION, ASD. 0 TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-F. STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES INSTITUTE FOR ELECTRICAL. AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING FAI RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3" AND "HIGH SYSTEM EXPOSURE) TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 NETWORK EQUIPMENT -BUILDING SYSTEM (NEBS): PHYSICAL PROTECTION TELCORDIA GR-347 CENTRAL OFFICE POWER WIRING TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS TELCORDIA CR-1503 COAXIAL CABLE CONNECTIONS FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS. THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL. GOVERN. DETAIL 303 AT&T WIRELESS TITLE SHEET NORTEL UMTS 187S SITE DRAWING RVASlas I BY Icw doe MAW or sow4m 9Y: 7DDt Dave BY. IYFd 24897-512-H 2 GAWM WAIM R[v STTLWASGI7-TOf 0 22 x 34 T S9 A ' SCANNED OCT 0 8 .tea,