Loading...
HomeMy WebLinkAboutWWP2703188.1O z U 4 STA. 5+65.78. 18.00' LT. w I 1 — 8" 45® BEND (MJxFL) 10 �' _� i 1 — 8" C.V. fFLxMJ� Co � �tBLOCK SSMH SD -O-R RIM 244.58 EMOVE EX. 8" TO SOUTH = IE = 238.13(E—S—N) FH IE = 238.03(°d) WV A e' 0� a ®E o U Z u! 750- a- r \c Cp v c E -9 g mta \ E CN E I C � v � CD I 0 9P-4 SSMH RIM = 246.20 IE = 238.40(E) IE = 238.30(W) SSMH RIM = 252.60 IE = 247.05(E) IE = 246.95(W) ! 1 \\ 1 " 4 - ND (MJ) ja2REs JANUARY 9, 2 :�ti I STA. 8+81.32, 6.00' LT. " 1 — R" 45• BENn (FL1 I — G.V. (MJ) 1 8 1 — BLOCUNDERGROUND PIPE LOCATION BASEvD ON SURFACE FEATURES. ACTUAL 1 — BLOCK ,-h \ LOCATION MAY VARY. I W \\ REMOVE EX. 8 PIPE SECTION TO NORTH I CONFIRM THAT THE LOCATIONS, ELEVATIONS, DEPTHS, AND AS-BUELT 9 00 n COMMENTS REFLECTING MATERIALS ACTUALLY USED DURING �r P� i s\ii 6 ,� np-;AIL CorISTRUCTIorI,ACCURATELY REFLEt;TSEXIST iGIIELDC()NDTfIONSAS N\ S.h d_ Y i_ S. i_ I I I i , \ �� u DETERMINE R DER MY DIRECT SJi-ERVISIOt4 ON THIS DATE: 'Cr Lu 1 00 PQ Cn D CD W 8" SS n SSMH RIM = 265.33 UP IE = 248.08(E—S ` 0- oTELR IE = 247.98(W) EX. 8" D.I. W. oil 8"x8" VERTICAL CROSS FOR POLYPIGGING (SEE DETAIL) 2" TEMP. BLOWOFF ASSEMBLY -� RECONNECT W. SVC. TO EX. HOUSE EX NEW 8" D.I. GRAPHIC SCAIJE 0 10 ! 40 ( IN FEET ) 1 inch = 20 ft CUT AND CAP OR REMOVE EXIST. 8" W TF-MNG DETAII FINAL C:ONNE `"ION DETAIL FINAL CONNECTION AFTER ALL TESTING, DISINFECTION AND POLYPIGGING, REMOVE TEMP. BLOWOFF AND CONNECT TO EX. 8" WATER MAIN WITH: 45° BEND (MJ) 8" SLEEVE 8" GATE VALVE Di SPOOLS TO FIT WATER MAIN CONNECTION DETAIL oft 3)49 Sol C 0,0 -1owvo;lI TEMPORARY 2' GALVANIZED PIPE AND _ GATE a nce r FINISHED GRADE ELE'VA s FT MIN. COMER (10-INCH DIAMETER AND UNDER) 4 FT MIN, COVER (12-INCH DIAMETER APED OVER) VERTICAL CROSS FOR POLYPIGGING STATION; SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2' TAP & 2' TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2' PLUG AFTER REMOVAL OF CLEANING °POLY -PIG') ONE BLIND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL '-ROSS BEFORE DISINFECTION OF NEW WATER MAIN WATER MAIN POLYPIGGING -(3TATION Is COMMENnF_n E IC SOP CIS PIGGING NTS By V uL � �1 ► 8 t04 �Y Y Y i DALEY-MORROW-POBLETE, INC. 726 AUBURN WAY N. AUBURN, WASHINGTON 98002 rn r1' �"NI 3 =: 253-333-2200; FAX: 253-33-2206 �I c - p it i' Lsrh I A KIM PI A IV IV MC-Z P �� L— � _ir s�e-e: --�: � �r ee ea '��• z� iricorpCDrat�e 9 JHN LVUb - - SCANNED APR 2 2