HomeMy WebLinkAboutWWP2703206.1Y SANITARY SEWER AND EXTENSIONPLAN
0
w
�o
s000ssit
z w
z �z
Z v1 __.........._._ .
I
w0 w
w Z
w ; .+ OSTA.
INSTALL:
w0 4+89.23 O.C.
a n
w. ,. .��z III°
is-1-8 x8 CROSS (FLxMJ) (VERTICAL)
w c w ' ` '' '`'` 1-8" BLIND FLANGE (FL)
O+ (BOTTOM OF CROSS)
Z U 1 2 TEMP. BLOW -OFF ASSEMBLY
Z Q w d 1-8"x6" TEE (FLxMJ)
Q a 1-6" GATE VALVE (FLxMJ)
mco
Q 1-FIRE HYD. PER CITY OF
W Q RENTON STANDARDS
CONC. BLOCKING
Q SEE CONNECTION DTL. 2, SHT. C16
DTL SHT. C9.
F.H. D AN- ---- - _ __N..... _.....
....
Q
O
I I '
I
,I ,
4r V V ' 1' - dam»,...::.. �:�:�.:� r -....
L
® 0.4%
WATER EASEMENT
3 � I
o o O O O O O O O O O O O O O O O O O
0 _Ire
lrT _ SSMH 1 54 FLATTOP »
® "Boo
6 DI
�c .� cn SHALLOW TYPE B PER FIRELINE
Q o E CITY STD. DETAIL No. B072
a_ 03 v TO SPRINKLER
Q RIM=21.01 » BUILDING E1 ROOM W/DDCVA
c _ IE=14.73 (81N)
['� a 15' WIDE °° IE=14.63 (8"OUT) FF=23.0 O5 INSTALL:
H w INSTALL: 4 STA. 64+94.89, O.C.
v SANITARY SEWER m STA. 62+09.45, O.C. O 1-12"x811 TEE (FLxFL)
EASEMENT (TYP.) o » » »
c E c� 1-12 x6 TEE (MJxFL) SSCO PER CITY 1-8 GATE VALVE (FLxMJ)
_ ° 1-6" GATE VALVE (FLxMJ) STD. DETAIL B076 1-12" GATE VALVE (FLxMJ)
aD 45 LF 12" DI W
-/
I.' n p
m E 10 LF 6 DI EXTENSION RIM=23.0 1-12 ADAPTOR (FLxMJ)
�.E _Nil,
°_ 1-FIRE HYD. PER CITY OF IE= CONC. BLOCKING
NRENTON STANDARDS - -
`' •c � :., o. "-� CONC. BLOCKING -
14 I c o, o w z
a OINSTALL:I 3 Wui
TA. 61 +64.45, O.C. (ANGLE PT.)
aw
in 3
1-12" 90' BEND (MJxMJ)
CONC. BLOCKING 15� WIDE
�m o ? WATERMAIN
BACKFLOW PREVENTER EASEMENT (TYP.)
15' WIDE SEE DETAIL SHEET C10
zZ WATER EASEMENT
1 0 6+ 6 L 1 I R 3+00 86 LF 1" DI WTR 4+00
-Z
0 136 LF 12" DI WTR I cr `
>-
16�...............-�................,
»,
I
o
m ao
0 365 LF 8" DI SS ® 0.4%
r a
��
Q z +-
R O II I ?
r 15' WIDE
NEW 1" IRRIGATION I SANITARY SEWER
N METER W/ BACKFLOW + EASEMENT (TYP.)
PREVENTOR (DCVA)
INSTALL 1 1 /2" WATER
PER CITY STD. SERVICE AND METER
U)
mio
r-
mm
z No
5- 320�03
0 15 INSTALL:
o .0 STA. 6+89.96, O.C.
m � m 1-8 x8 CROSS (FLxMJ) (VERTICAL)
m � z 1-8" PLUG (MJ)
z CC) 1-8" BLIND FLANGE (FL)
Z 0 1-2" TEMP. BLOW -OFF ASSEMBLY
o = 1-8"x6" TEE (FLxMJ)
1-6" GATE VALVE (FLxMJ)
SPRINGBROOK CREEK AND GREENBELT 14 LF 6" DI EXTENSION
1-FIRE HYD. PER CITY OF
-:I m S01 °47 39 W 916.00' RENTON STANDARDS
0 GONG. 13LOCKING
SEE CONNECTION DTL. 2, SHT. C16
00 AND F.H. DTL. SHT. C9.
mm
5+10g4„m
7 10
a
li
+1€ FI
91x
KA
27 LF 12
SSMH #2 (54" FLATTOP)
�
-�--�--
En
Y
m
o
ADJUST EXIST. HYDRANT DI WTR
TO FINISHED GRADE
- --
SHALLOW TYPE "B" PER
INSTALL:
AND INSTALL 5"
_
_
_
-
CITY STD. DETAIL No. B072
BACKFLOW PREVENTER 16
STA. 4+78.27, 0 C
STORTZ ADAPTOR
_--�
_
RIM=21.44"
IE=15.65(8 IN)
SEE DETAIL SHEET C10
1-8"x6" TEE (FLxMJ)
STA. 16+95.82
_
IE=15.55(8 OUT)
1-6" GATE VALVE(FLxMJ)
r
(SW 34th ST.)=
15 WIDE WATER
SSCO PER CITY
STD. DETAIL B076
26 LF 6" DI EXTENSION
1-FIRE HYD. PER CITY
a
w
STA. 59+65.43
[
+
EASEMENT
RIM=23.00
OF RENTON STANDARDS
•
r
+
o
2
O
IE=20.00
CONC. BLOCKING
o
o
INSTALL:
BUILDING E2
STA. 60+28.59, O.C. ANGLE PT.)
m
0
m
0
m
0
m
0
m
o
Q
EXISTING 10"
1-12" 90' BEND (MJxMJ)
FF=23.0
TO SPRINKLER
•r
r7
DI WATER STUB
101
CONC. BLOCKING
ROOM W/DDCVA
49' 10"E 46.39
41
0
0
0
z
�
Q
Z
o0
w
U
Zz
QO
w
w05�
cW
3::w
w
Q
w
cj)w�OF-
is-
�z
U
a)
QQ
w
W
Q�
Q
Q
�
a
w
O
/ ,,
_.... .... M_� .....:..... _.. .... :..n::...:...
w..
1 i
\
1 15 WIDE \
INSTALL:
STA.4+07.00, O.C. WATER EASEMENT 4' rv�, o
1-8"x6" CROSS (MJxFL) $ INSTALL: _� r•` } O o
2-6" GATE VALVES(FLxMJ) O STA. 67+92.83, O.C.
O
1-12"xB" TEE (FLxMJ)
6"
GATE „__ z
1-8 GATE VALVE (FLxMJ) i , w \.\
VALVE(MJxMJ) BUILDING E3 CONC. BLOCKING 15' WIDE �� A` J o
TO SPRINKLERco
-1 INEFF=23.0 10 LF 12" DI WTR SANITARY SEWE Icc
ROOM W/DDCVA _ EASEMENT -----
INSTALL: _ N
O7 0 0 \ _ _.._.
48 LF 12" DI WTR STA. 67+82.91, O.C. __ o
# „ , ( 1H 'SAND AREA Lo
1-8"x6" TEE (FLxMJ) SM ; ,, • N w Qi � N
INSTALL: 6 1-6" GATE VALVE (FLxMJ) HA 0 E B P R € Z
STA. 65+4 .84, O.C. 5 LF 6" DI EXTENSION rn ITY ST ETAIL 07 ;' ��* BUF o w Q
1-`I x8 TEE (FLxMJ) 1-FIRE HYD. PER CITY OF7ESTIMATED
RENTON STANDARDS
1-8 GATE VALVE IE=18.56(6 IN) Q Z00
CONC. BLOCKING IE=18.39(8"OUT)
�- -�-
SSCO° PER CITY > o
56 LF 12" INSTALL 1 1 /2" WATER STD. DETAIL B076 INSTALL 1 1 /2" WATER EXISTING w Q O
SERVICE AND METER". Z
$ FENCE °
DI WTR RIM=23.00 SERVICE AND METER
I E=20.00 I 1 o
BACKFLOW PREVENTER g• BACKFLOW PREVENTER r
SEE DETAIL SHEET C10 SEE DETAIL SHEET C10 f W
6 184 LF 12 DI WTR 67+00 + 0 SSCO PER CITY
STD. DETAIL B076 I O
;
_ RIM=23.00 Q
296 L 8" DI SS ® 00
0.4% - -;;
pd 41 LF 12" DI WTRply
, r
_ Kf ENTER 58 LF 12" 6" DI o
15' WID SSMH 3 SEE DETAIL SHEET C10 DI WTR FIRELINE
2.5'�II WATER EASEMEN SHALLOW TYPE "B" PER I TO SPRINKLER t
DC CITY STD. DETAIL No. B07Z ROOM W/DDCVA
RIM=20.92
IE=17.21(8"IN) jSCO PER CITYDki 6
IE=17.11(8"OUT) STQ. DETAIL 8076 O
RIIE=20.00 BUILDING E5
cn
CD- -- -- a FF 230 r� Z�
N l z0
INSTALL: w o o
LO STA. �68+50.82, O.C. (ANGLE PT.) � w a CD-pl 1-12 90' BEND (MJxMJ) co iv C X p I-
E CONC. BLOCKING �G Q z z
Z u i
� 20� o 15' WIDE GJ Q r� j N N p
F LINE BUILDING E4 WATER EASEMENT O N 00
o TO SPRINKLER 0 ao N r z>
rn(Doo �z
= ROOM W/DDCVA FF=23.0 wl N I l w w
w UTILITY °D
o w 10 INSTALL
cv N o a .- Q SEMENI` ° J STA. 68+82.61 O.C. ` N N z Z w
In c�
-ILL
°`' INSTALL: 15� WIDE 1-12"x6" TEE (MJxFL) N Z N N J
STA. 5+32.77, O.C. 1-6" GATE VALVE MJxFL „w
�- 2.5 WATER EASEMENT ( ) Y
$ m W 1 -8Mx6" CROSS (MJxFL) CONC. BLOCKING ^ v N
m 0 39 LF 12 DI WTR u u Irnl"I
a Y m �0 2-6 GATE VALVES(FLxMJ) w N v
n O
f
nc .... . .. - .. .......... .__ .. .. _.,.�_._ .......... _................_. �w
_ S _01°35.18.., :W _._..._..._ ............... 937.16 _ab�
o: oo ,----EX. FHcn
J �n
o to Z o3 :._ ._ ._ .... .. EX. 10" WATER EX. 10" WATER . - Z o
o
_ _...___
z
Q
F- _._._..... p - 1$ _ ._ _.INSTALL -._._ _ ._ ._ ._ ._ INSTALL.--
EX: F"PSI� .... , o0
NOTE: + INSTALL: 01-12mx6m
STA. 70+60.11, O.C. 1-12"x12" CROSS (FLxW(J) (VEF $ft L) cn 00w w FIELD LOCATE, REMOVEEX. FH Rm STA. 6+49.17 O.C. CUT IN:^EACH SIDE SEWER SHALL BE PROVIDED WITH c� EX. FH TEE MJxFL 1-12 PLUG MJ -' c�PLUG AND BLOCKING m -I ^ ^TEE(MJxFL) 1 ( ) l`�
mo BACKWATER VALVE BY MANHOLE PER DETAIL SHEET. m w 0 1-10 x8 WET TAPPING TEE n STA. 70+99.36, O.C. »
m INSTALL: m n n 1-6 GATE VALVE(MJxFL) n 1-12 BLIND FLANGE (FL) (BOTTOM OF CROSS) o �► r Jv
cn
3
O
oomoa
m
z
of
i
Ljj
U
U ce
U
CL
w
IY cr
ir
w
w
w w
w
w
a
a a_
a_
C
00
0
0
011
w
w w
w
wl
V)
V) (n
cn
U)
201
2*j 2*jajoaI
z
In
M
N
r- Z
STA. 60+03.57f, O.C. VALVE SHALL BE MODEL 675 P BY NDS. D 1-8 GATE VALVE(FLxMJ) 25 LF 6" DI EXTENSION 1-10 TEE (FL) 1-2" TEMP. BLOW -OFF ASSEMBLY
(FLxMJ) ( ) SEE SHEET C14 FOR '- CONC. BLOCKING 2-10" GATE VALVES (FLxMJ) G�
1-10"x10" CROSS FLxMJ VERTICAL 1-FIRE HYD PER CITY OF 1-12" GATE VALVE
N o°O° c� 1-10" PLUG (MJ) ®FITTING LOCATION IN SEE CONNECTION DTL. 3, SHT. C16 RENTON STAN ARDS
o CD w o 1-10" BLIND FLANGE (FL) PROFILE VIEW. CONC. BLOC G 2-2 LF 10" DI SPOOLS 0
o w (BOTTOM OF CROSS) 1-10"x12" INCREASER CITY OF RENTON E5
1-2" TEMP. BLOW -OFF ASSEMBLY CONC. BLOCKING I=
1-12"00" REDUCER(FLxMJ) RECOMMENDED FOR APPROVAL UTILITY NOTES 6 ADDED HANDRAIL AND LANDSCAPE SEE CONNECTION DTL. 1, SHT. C16 �EPAFRTMEN-F OF PUBLIC WORKS
1-10" GATE VALVE(MJxFL) NOTE PER CITY BW DKB 11 /09/04
CONC. BLOCKING ALL SANITARY SEWER SERVICES SHALL BE PROVIDED Q� C
SEE CONNECTION DTL. 4, SHT. C16 By: Date: 2' WITH BACK WATER VALVE PER CITY STD. �� 5 REVISED PER CITY REVIEW COMMENTS PRA DKB 10/27/04 z
AS
N r 4 REVISED PER CITY REVIEW COMMENTS KIB DKB 9/22/04 8/1/04
N HORIZONTAL DATUM - BASS OF BEARINGS (NAD 83/9U By: Date: THE MAXIMUM AVAILABLE FIRE FLOW FROM THE EXISTING - O
+ 12" WATERMAINS IN SOUTHWEST 34th STREET, IN OAKESDALE 3 REVISED PER REVIEW COMMENTS LK AS 8/01/04
VERTICAL DATUM - BASIS OF ELEVATIONS AVENUE SOUTH WEST, AND FROM THE 12" LOOPED WATERMAINS 5672 �p �- ` ` _ DATE 1 "_�/ FILE NO.
�� CITY OF RENTON BM 2108 (NAVD 1988) By: Date AROUND THE SITE IS LIMITED TO 5,000 gpm AT 20 PSI S 01STER ���` 2 REVISED PER CITY REVIEW COMMENTS BSW AS 2/12/04 DRAWN -
LIND AVE. S.W. % �G -- _ w
RESIDUAL PRESSURE. THE STATIC PRESSURE IS APPROXIMATELY NA L E 1 ADDED r WINE TO BUILDING BW AS 1/19/04 cH-�;�=-. scALE __ -_ FIELD BOOK PAGE_ ,
ELEV. ■ 10.55 FEET 70 PS1 AT FINISHED FLOOR ELEVATION = 24.01 U
By: Date EXPIRES 9 23 05 NO. REVISION BY APPR. DATE APPRO`-r C
-- - SHEET OF 16
B�
Aa s- 320�03; � 32o�oy
fn
c�-.414INFD OCT 2 8 Z005