HomeMy WebLinkAboutWWP2703206.1Y SANITARY SEWER AND EXTENSIONPLAN 0 w �o s000ssit z w z �z Z v1 __.........._._ . I w0 w w Z w ; .+ OSTA. INSTALL: w0 4+89.23 O.C. a n w. ,. .��z III° is-1-8 x8 CROSS (FLxMJ) (VERTICAL) w c w ' ` '' '`'` 1-8" BLIND FLANGE (FL) O+ (BOTTOM OF CROSS) Z U 1 2 TEMP. BLOW -OFF ASSEMBLY Z Q w d 1-8"x6" TEE (FLxMJ) Q a 1-6" GATE VALVE (FLxMJ) mco Q 1-FIRE HYD. PER CITY OF W Q RENTON STANDARDS CONC. BLOCKING Q SEE CONNECTION DTL. 2, SHT. C16 DTL SHT. C9. F.H. D AN- ---- - _ __N..... _..... .... Q O I I ' I ,I , 4r V V ' 1' - dam»,...::.. �:�:�.:� r -.... L ® 0.4% WATER EASEMENT 3 � I o o O O O O O O O O O O O O O O O O O 0 _Ire lrT _ SSMH 1 54 FLATTOP » ® "Boo 6 DI �c .� cn SHALLOW TYPE B PER FIRELINE Q o E CITY STD. DETAIL No. B072 a_ 03 v TO SPRINKLER Q RIM=21.01 » BUILDING E1 ROOM W/DDCVA c _ IE=14.73 (81N) ['� a 15' WIDE °° IE=14.63 (8"OUT) FF=23.0 O5 INSTALL: H w INSTALL: 4 STA. 64+94.89, O.C. v SANITARY SEWER m STA. 62+09.45, O.C. O 1-12"x811 TEE (FLxFL) EASEMENT (TYP.) o » » » c E c� 1-12 x6 TEE (MJxFL) SSCO PER CITY 1-8 GATE VALVE (FLxMJ) _ ° 1-6" GATE VALVE (FLxMJ) STD. DETAIL B076 1-12" GATE VALVE (FLxMJ) aD 45 LF 12" DI W -/ I.' n p m E 10 LF 6 DI EXTENSION RIM=23.0 1-12 ADAPTOR (FLxMJ) �.E _Nil, °_ 1-FIRE HYD. PER CITY OF IE= CONC. BLOCKING NRENTON STANDARDS - - `' •c � :., o. "-� CONC. BLOCKING - 14 I c o, o w z a OINSTALL:I 3 Wui TA. 61 +64.45, O.C. (ANGLE PT.) aw in 3 1-12" 90' BEND (MJxMJ) CONC. BLOCKING 15� WIDE �m o ? WATERMAIN BACKFLOW PREVENTER EASEMENT (TYP.) 15' WIDE SEE DETAIL SHEET C10 zZ WATER EASEMENT 1 0 6+ 6 L 1 I R 3+00 86 LF 1" DI WTR 4+00 -Z 0 136 LF 12" DI WTR I cr ` >- 16�...............-�................, », I o m ao 0 365 LF 8" DI SS ® 0.4% r a �� Q z +- R O II I ? r 15' WIDE NEW 1" IRRIGATION I SANITARY SEWER N METER W/ BACKFLOW + EASEMENT (TYP.) PREVENTOR (DCVA) INSTALL 1 1 /2" WATER PER CITY STD. SERVICE AND METER U) mio r- mm z No 5- 320�03 0 15 INSTALL: o .0 STA. 6+89.96, O.C. m � m 1-8 x8 CROSS (FLxMJ) (VERTICAL) m � z 1-8" PLUG (MJ) z CC) 1-8" BLIND FLANGE (FL) Z 0 1-2" TEMP. BLOW -OFF ASSEMBLY o = 1-8"x6" TEE (FLxMJ) 1-6" GATE VALVE (FLxMJ) SPRINGBROOK CREEK AND GREENBELT 14 LF 6" DI EXTENSION 1-FIRE HYD. PER CITY OF -:I m S01 °47 39 W 916.00' RENTON STANDARDS 0 GONG. 13LOCKING SEE CONNECTION DTL. 2, SHT. C16 00 AND F.H. DTL. SHT. C9. mm 5+10g4„m 7 10 a li +1€ FI 91x KA 27 LF 12 SSMH #2 (54" FLATTOP) � -�--�-- En Y m o ADJUST EXIST. HYDRANT DI WTR TO FINISHED GRADE - -- SHALLOW TYPE "B" PER INSTALL: AND INSTALL 5" _ _ _ - CITY STD. DETAIL No. B072 BACKFLOW PREVENTER 16 STA. 4+78.27, 0 C STORTZ ADAPTOR _--� _ RIM=21.44" IE=15.65(8 IN) SEE DETAIL SHEET C10 1-8"x6" TEE (FLxMJ) STA. 16+95.82 _ IE=15.55(8 OUT) 1-6" GATE VALVE(FLxMJ) r (SW 34th ST.)= 15 WIDE WATER SSCO PER CITY STD. DETAIL B076 26 LF 6" DI EXTENSION 1-FIRE HYD. PER CITY a w STA. 59+65.43 [ + EASEMENT RIM=23.00 OF RENTON STANDARDS • r + o 2 O IE=20.00 CONC. BLOCKING o o INSTALL: BUILDING E2 STA. 60+28.59, O.C. ANGLE PT.) m 0 m 0 m 0 m 0 m o Q EXISTING 10" 1-12" 90' BEND (MJxMJ) FF=23.0 TO SPRINKLER •r r7 DI WATER STUB 101 CONC. BLOCKING ROOM W/DDCVA 49' 10"E 46.39 41 0 0 0 z � Q Z o0 w U Zz QO w w05� cW 3::w w Q w cj)w�OF- is- �z U a) QQ w W Q� Q Q � a w O / ,, _.... .... M_� .....:..... _.. .... :..n::...:... w.. 1 i \ 1 15 WIDE \ INSTALL: STA.4+07.00, O.C. WATER EASEMENT 4' rv�, o 1-8"x6" CROSS (MJxFL) $ INSTALL: _� r•` } O o 2-6" GATE VALVES(FLxMJ) O STA. 67+92.83, O.C. O 1-12"xB" TEE (FLxMJ) 6" GATE „__ z 1-8 GATE VALVE (FLxMJ) i , w \.\ VALVE(MJxMJ) BUILDING E3 CONC. BLOCKING 15' WIDE �� A` J o TO SPRINKLERco -1 INEFF=23.0 10 LF 12" DI WTR SANITARY SEWE Icc ROOM W/DDCVA _ EASEMENT ----- INSTALL: _ N O7 0 0 \ _ _.._. 48 LF 12" DI WTR STA. 67+82.91, O.C. __ o # „ , ( 1H 'SAND AREA Lo 1-8"x6" TEE (FLxMJ) SM ; ,, • N w Qi � N INSTALL: 6 1-6" GATE VALVE (FLxMJ) HA 0 E B P R € Z STA. 65+4 .84, O.C. 5 LF 6" DI EXTENSION rn ITY ST ETAIL 07 ;' ��* BUF o w Q 1-`I x8 TEE (FLxMJ) 1-FIRE HYD. PER CITY OF7ESTIMATED RENTON STANDARDS 1-8 GATE VALVE IE=18.56(6 IN) Q Z00 CONC. BLOCKING IE=18.39(8"OUT) �- -�- SSCO° PER CITY > o 56 LF 12" INSTALL 1 1 /2" WATER STD. DETAIL B076 INSTALL 1 1 /2" WATER EXISTING w Q O SERVICE AND METER". Z $ FENCE ° DI WTR RIM=23.00 SERVICE AND METER I E=20.00 I 1 o BACKFLOW PREVENTER g• BACKFLOW PREVENTER r SEE DETAIL SHEET C10 SEE DETAIL SHEET C10 f W 6 184 LF 12 DI WTR 67+00 + 0 SSCO PER CITY STD. DETAIL B076 I O ; _ RIM=23.00 Q 296 L 8" DI SS ® 00 0.4% - -;; pd 41 LF 12" DI WTRply , r _ Kf ENTER 58 LF 12" 6" DI o 15' WID SSMH 3 SEE DETAIL SHEET C10 DI WTR FIRELINE 2.5'�II WATER EASEMEN SHALLOW TYPE "B" PER I TO SPRINKLER t DC CITY STD. DETAIL No. B07Z ROOM W/DDCVA RIM=20.92 IE=17.21(8"IN) jSCO PER CITYDki 6 IE=17.11(8"OUT) STQ. DETAIL 8076 O RIIE=20.00 BUILDING E5 cn CD- -- -- a FF 230 r� Z� N l z0 INSTALL: w o o LO STA. �68+50.82, O.C. (ANGLE PT.) � w a CD-pl 1-12 90' BEND (MJxMJ) co iv C X p I- E CONC. BLOCKING �G Q z z Z u i � 20� o 15' WIDE GJ Q r� j N N p F LINE BUILDING E4 WATER EASEMENT O N 00 o TO SPRINKLER 0 ao N r z> rn(Doo �z = ROOM W/DDCVA FF=23.0 wl N I l w w w UTILITY °D o w 10 INSTALL cv N o a .- Q SEMENI` ° J STA. 68+82.61 O.C. ` N N z Z w In c� -ILL °`' INSTALL: 15� WIDE 1-12"x6" TEE (MJxFL) N Z N N J STA. 5+32.77, O.C. 1-6" GATE VALVE MJxFL „w �- 2.5 WATER EASEMENT ( ) Y $ m W 1 -8Mx6" CROSS (MJxFL) CONC. BLOCKING ^ v N m 0 39 LF 12 DI WTR u u Irnl"I a Y m �0 2-6 GATE VALVES(FLxMJ) w N v n O f nc .... . .. - .. .......... .__ .. .. _.,.�_._ .......... _................_. �w _ S _01°35.18.., :W _._..._..._ ............... 937.16 _ab� o: oo ,----EX. FHcn J �n o to Z o3 :._ ._ ._ .... .. EX. 10" WATER EX. 10" WATER . - Z o o _ _...___ z Q F- _._._..... p - 1$ _ ._ _.INSTALL -._._ _ ._ ._ ._ ._ INSTALL.-- EX: F"PSI� .... , o0 NOTE: + INSTALL: 01-12mx6m STA. 70+60.11, O.C. 1-12"x12" CROSS (FLxW(J) (VEF $ft L) cn 00w w FIELD LOCATE, REMOVEEX. FH Rm STA. 6+49.17 O.C. CUT IN:^EACH SIDE SEWER SHALL BE PROVIDED WITH c� EX. FH TEE MJxFL 1-12 PLUG MJ -' c�PLUG AND BLOCKING m -I ^ ^TEE(MJxFL) 1 ( ) l`� mo BACKWATER VALVE BY MANHOLE PER DETAIL SHEET. m w 0 1-10 x8 WET TAPPING TEE n STA. 70+99.36, O.C. » m INSTALL: m n n 1-6 GATE VALVE(MJxFL) n 1-12 BLIND FLANGE (FL) (BOTTOM OF CROSS) o �► r Jv cn 3 O oomoa m z of i Ljj U U ce U CL w IY cr ir w w w w w w a a a_ a_ C 00 0 0 011 w w w w wl V) V) (n cn U) 201 2*j 2*jajoaI z In M N r- Z STA. 60+03.57f, O.C. VALVE SHALL BE MODEL 675 P BY NDS. D 1-8 GATE VALVE(FLxMJ) 25 LF 6" DI EXTENSION 1-10 TEE (FL) 1-2" TEMP. BLOW -OFF ASSEMBLY (FLxMJ) ( ) SEE SHEET C14 FOR '- CONC. BLOCKING 2-10" GATE VALVES (FLxMJ) G� 1-10"x10" CROSS FLxMJ VERTICAL 1-FIRE HYD PER CITY OF 1-12" GATE VALVE N o°O° c� 1-10" PLUG (MJ) ®FITTING LOCATION IN SEE CONNECTION DTL. 3, SHT. C16 RENTON STAN ARDS o CD w o 1-10" BLIND FLANGE (FL) PROFILE VIEW. CONC. BLOC G 2-2 LF 10" DI SPOOLS 0 o w (BOTTOM OF CROSS) 1-10"x12" INCREASER CITY OF RENTON E5 1-2" TEMP. BLOW -OFF ASSEMBLY CONC. BLOCKING I= 1-12"00" REDUCER(FLxMJ) RECOMMENDED FOR APPROVAL UTILITY NOTES 6 ADDED HANDRAIL AND LANDSCAPE SEE CONNECTION DTL. 1, SHT. C16 �EPAFRTMEN-F OF PUBLIC WORKS 1-10" GATE VALVE(MJxFL) NOTE PER CITY BW DKB 11 /09/04 CONC. BLOCKING ALL SANITARY SEWER SERVICES SHALL BE PROVIDED Q� C SEE CONNECTION DTL. 4, SHT. C16 By: Date: 2' WITH BACK WATER VALVE PER CITY STD. �� 5 REVISED PER CITY REVIEW COMMENTS PRA DKB 10/27/04 z AS N r 4 REVISED PER CITY REVIEW COMMENTS KIB DKB 9/22/04 8/1/04 N HORIZONTAL DATUM - BASS OF BEARINGS (NAD 83/9U By: Date: THE MAXIMUM AVAILABLE FIRE FLOW FROM THE EXISTING - O + 12" WATERMAINS IN SOUTHWEST 34th STREET, IN OAKESDALE 3 REVISED PER REVIEW COMMENTS LK AS 8/01/04 VERTICAL DATUM - BASIS OF ELEVATIONS AVENUE SOUTH WEST, AND FROM THE 12" LOOPED WATERMAINS 5672 �p �- ` ` _ DATE 1 "_�/ FILE NO. �� CITY OF RENTON BM 2108 (NAVD 1988) By: Date AROUND THE SITE IS LIMITED TO 5,000 gpm AT 20 PSI S 01STER ���` 2 REVISED PER CITY REVIEW COMMENTS BSW AS 2/12/04 DRAWN - LIND AVE. S.W. % �G -- _ w RESIDUAL PRESSURE. THE STATIC PRESSURE IS APPROXIMATELY NA L E 1 ADDED r WINE TO BUILDING BW AS 1/19/04 cH-�;�=-. scALE __ -_ FIELD BOOK PAGE_ , ELEV. ■ 10.55 FEET 70 PS1 AT FINISHED FLOOR ELEVATION = 24.01 U By: Date EXPIRES 9 23 05 NO. REVISION BY APPR. DATE APPRO`-r C -- - SHEET OF 16 B� Aa s- 320�03; � 32o�oy fn c�-.414INFD OCT 2 8 Z005