HomeMy WebLinkAboutWTR2703214.13PROPOSED NEMA 4X, 12" SECURE 3/8" THICK SS PLATE RESERVOIR INTERIOR RESERVOIR ROOF ACCESS - -- - -- - ----- -- --- - — ------ ---- TO RAILING IN 2 LOCATIONS ACCESS HATCH. PLATFORM LB CONDUIT BODY WITH ANTENNA I H. X 12" JUNCTION BOX USING () /. / CORD GRIP BUSHING ELECTRICAL MOTES of WA& � SECURED TO SS PLATE 312" SS BOLTS:es [ % FEED LINE WITH 1 4" STAINLESS t X� 1. SEE DWG NO. E05 FOR ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE. �` [ STEEL HARDWARE FOR 9 ' SPLICING FLOAT CABLE XXX 2. SEE DWG NO. E05 FOR CONDUIT AND CONDUCTOR SCHEDULES. AND TRANSDUCER CABLE '6727 I TO FIELD WIRE. TELEMETRY Al 3. SEE LIGHTING FIXTURE SCHEDULE ON DWG NO. E05. ° S0IsT8g69�? CONTRACTOR SHALL ANTENNA � joNaL � 1Y4" GALVANIZED RIGID 4 4. CONDUIT AND CONDUCTORS TO THE TELEMETRY PANEL, "RTU", LOCATED IN THE PROPOSED ELECTRICAL BUILDING. SEE PROPOSED ENSURE JUNCTION BOX IS g STEEL x 12" LONG f POSITIONED 20 ✓ ELECTRICAL SITE v CONTINUATION. SEE DWG NO. E02 FOR DETAILS. i ACCESSIBLE FOR MAINTENANCE PURPOSES. ABOVE GRADE. - RESERVOIR INL� 'LOW (4-20mA) SIGNED: 06129107 1 � CONTRACTOR SHALL ` NSTALL PROPOSED LEVEL MALLEABLE IRON OR - R RVOIR INLET FLOW (TOTALIZER) TRANSDUCER BREATHER © STEEL REDUCER COORDINATE WITH _ R PVOIR INLET FLOW METER POWER (24 VDC) MIL BAG AND DESICCANT OWNER ON ( ) FILTER IN PROPOSED ! DIRECTION TO POINT - I' OIR OUTLET FLOW (TOTALIZER) ) l WAsAl� - R -RVOIR OUTLET FLOW TOTALIZER ' JUNCTION BOX. ANTENNA. - R ERVOIR OUTLET FLOW METER POWER (24 VDC) PROPOSED RESERVOIR C7 - VAULT FLOOD ALARM ! ' TELEMETRY JUNCTION 5 5. CONDUIT AND CONDUCTORS TO THE SEISMIC CONTROL PANEL. LOCATED IN THE PROPOSED ELECTRICAL BUILDING. SEE PROPOSED 38613 BOX N0. 2 ELECTRICAL SITE PLAN FOR CONTINUATION. SEE DWG NO. E02 FOR DETAILS. $e�,HT8�6� RESERVOIR ROOF ACCESS Sr01JAL PLATFORM RAILING -VALVE OPEN CALL - VALti ;LOSE CALL 18"W X 18°L X 3 8" 2' RIGID ,, { THICK SS PLATE. GALVANIZED STEEL - VALv =JLL CLOSED STATUS SIGNED: 06129107 1 PROPOSED ACCESS HATCH INTRUSION - VALb ULL OPEN STATUS RESERVOIR INTERIOR CH INSTALLED IN ACCESS HATCH CONTRACTOR SHALL PROVIDE 6 6. CONDUIT AND CONDUCTORS TO THE TELEMETRY PANEL, "RTU", LOCATED IN THE PROPOSED ELECTRICAL BUILDING. >EE PROPOSED Y I ARM BEST SUITED FOR THIS ELECTRICAL SITE PLAN FOR CONTINUATION. SEE DWG N0. E02 FOR DETAILS. C8 C7 RESERVOIR INTERIOR LADDER ! ATION. CONTACT SHALL BREAK - VAULT FLOOD ALARM 1 -ATCH IS OPENED. RESERVOIR EXTERIOR 1" GRS TO ��� "U" CLAMP 7. PROPOSED SUMP PUMP WITH PIGGY BACK FLOAT SWITCH, 120 VAC, 10. PROPOSED PROPOSED JUNCTION BOX. 0 J3 SECURE CONDUIT TO LADDER IN TO "RTU" CONDUIT "T" FITTING 8 8• PROPOSED WEATHERPROOF DEDICATED RECEPTACLE FOR POWERING PROPOSED SUMP PUMP. rIL COIL 5 FEET OF EXTRA CABLE 4 LOCATIONS WITH STAINLESS 9. PROPOSED CONDUIT AND CONDUCTORS TO LIGHTING PANELBOARD, "L", LOCATED IN THE PROPOSED ELECTRICAL BUILDING, SEE PROPOSED ' IN JUNCTION BOX. STEEL HARDWARE EXTERIOR CMU WALL ELECTRICAL SITE PLAN FOR CONTINUATION. SET FLOAT TO ACTUATE 3" RESERVOIR INTERIOR 1 V C8 LANDING RAILING "U" CLAMP; FASTEN TO jh 569.30' BELOW OVERFLOW ELEVATION. D G UNISTRUT, TYPICAL OVERFLOW ELEVATION PROPOSED COPPER GROUND PLATE. CONTRACTOR SHALL INSTALL #6 BARE COPPER ELECTRICALLY GROUND THE PROPOSED EXTERIOR RESERVOIR (4) GROUND PLATES ON THE RESERVOIR EXTERIOR HANDRAIL. I O GROUND TO PROPOSED COPPER GROUND PLATE TO THE TANK RAILING BY BOLTING RAILING. INSTALL PRE -DRILLED GROUND PLATES SHALL BE SPACED EQUALLY APART AROUND THE GROUNDING SYSTEM. GROUNDING PLATES ON THE CIRCUMFERENCE OF THE RESERVOIR EXTERIOR RAILING. STAINLESS STEEL UNISTRUT THE RESERVOIR RAILING, TYPICAALL THE COPPER GROUND PLATE INSIDE OF THE LOWEST CONTRACTOR SHALL INSTALL A #6 COPPER GROUND CONDUCTOR Q OF 2 LOCATIONS. GROUNDING �. EXTERIOR RESERVOIR RAILING. BETWEEN EACH GROUND PLATE AROUND THE RESERVOIR EXTERIOR AND UNISTRUT BRACKET. RAILING. �n RESERVOIR FASTEN TO CONCRETE WALL i PLATE HOLES SHALL BE v� AND PROVIDE UNISTRUT AS PRE -DRILLED. RESERVOIR WALL INTERIOR LANDING � Z ,� REQUIRED, TYPICAL OF 2 LOCATIONS. Q ' ..a J TRANSDUCER CABLE. PROVIDE ENOUGH CABLE FOR RESERVOIR J TRANSDUCER TO REACH - - [ ELECTRICAL BUILDING BOTTOM OF RESERVOIR. ! J ANTENNA INSTALLATION DETAIL TJ /PROPOSED COPPER GROUND PROPOSED MECHANICAL GROUND PROPOSED #6 COPPER V/ PLATE, 6 H X 18 L. GROUND CONDUCTOR TO " BONDING CONNECTORS GROUNDING PLATE NO. PROPOSED #6 COPPER CONNECTED TO GROUND PLATE, 2 OF 4 }� Q SO CORD CONNECTOR (TYPICAL). SURF- MOUNTED J-BOX. GROUND CONDUCTOR TO (TYP. OF 2). t GROUNDING PLATE NO. 4 OF 4 "' w I 2" DIA. SCH 40 PVC PIPE. LOCATE PIPE' W ADJACENT TO RESERVOIR INTERIOR LANDING L p RESERVOIR GROUND 'LATE CONNECTION DETAIL SO THAT LEVEL TRANSDUCER IS SO TYPE CORD. -�� ___ ---- _- _ __._.. _ _ ___.-------------_--- W ACCESSIBLE FOR MAINTENANCE PURPOSES. NOT TO SCALE CADWELD TYPE TA. SECURE TO RESERVOIR WALL GRC CONDUIT STRAPPED TO CADWELD TYPE RR. CADWELD CADWELD CABLE TO WITH STAINLESS STEEL CLAMPS WALL WITH MINIMUM OF (2) I END CABLE TO UPPER REBAR #6 COPPER CABLE TEE . AND UNISTRUT AT 36" OC. STAINLESS STEEL PIPE CLAMPS CONNECTION. ;T CONDUCTOR CONNECTION.(n i SPACED EQUALLY APART. U I RESERVOIR EXTERIOR RESERVOIR INTERIOR REBAR cc 4 LIQUID LEVEL SWITCH. SET TO I #6 COPPER LEVEL TRANSDUCER SWITCH WITH 1 2" OF WATER D CONDUCTOR END CONDUIT 1 ABOVE / M ON FLOOR. RESERVOIR FLOOR. RESERVOIR FLOOR` H r: � .00' t FLOOR ELEVATION GROUND REBAR DETAIL GROUND TEE DETAIL I RESERVOIR INTERIOR ELECTRICAL DETAILS - - -- _ - � '' [' NOT TO SCALE NOT TO SGH. low FLOOD W"v ITCH DETAIL CADWELD TYPE XA. CADWELD CABLE TO CABLE CROSS CADWELD TYPE GR h� , c� PR�� ° OSED CONCRETE COVER. CONNECTION. #6 COPPER CADWELD CABLE TO j P17 P18 5 GRADE CONDUCTOR GROUND ROD CONNECTION. 8 8 _ METER VAULT ° 7 7 C9 / PROPOSED CONCRETE GROUND BOTHELL M ACCESS OPENING ° I 425.951.5400 ? RESERVOIR ' ROD PROTECTOR 13' DEPTH X " , y Y 2100 NE 195th Street, �u;te ,vu _ _ _ _ _ OUTLET PIPE 6 ° 3 4 X 8 COPPER ° 12 HEIGHT WITH COVER. PIPE #6 COPPER i CONDUCTOR GROUND ROD INC. #12R-12A & 12R-12T, OR . EAST WENATCHEE OFFICE [ EQUAL. (TYPICAL) -909.886.2900 300 Simon Street, Suite 5 t FORT ORCHARD OFFICE I � 360.876.7960 PROPOSED OUTLET FLOW METER I I I - PROPOSED 3/4 x8 LONG /� �00 Kitsap c+-ep+. c„i4p 101 I I J2C J2D I I C10 COPPER GROUND ROD. GROUND CROSS DETAIL GROUND TEE DETAIL AIL ACCESS I _ � OPENING I SC �� i — — — 8'-0„ MOO 0 1„ 2„ DRAWING IS NOT TO SCALE I j ci RESERVOIR INLET PIPE SEISMIC VALVE VAULT � REVISED �? CO�IIF(�RM IF BAR IS NOT 2" LONG PLOT: 96 DWG NO. PROPOSED INLET J28 J2A J2 PROPOSED SEISMIC SOLENOID VALVE AND -Q:O/TRC ICE CORD FLOW METER LIMIT SWITCH. SEE SPECIFICATIONS FOR �,,�'� - CMR E04 J2E MORE INFORMATION. W 321436 _ ! ,`";r 06/08/09J L M { ' �'H '3INEERING INC. DATE _ - -- FP 14. 2009e. SEISMIC VALVE AND METER VAULT ELECTRICAL PLANS - - i t�r�.- kii-T -. �uEN is :. I vNr vKh1 N: ' RUCTION RECORi .. DY KJS 06/08/09 REN —, GROUND ROD DETAIL - - LNDUM /ISSUED' CONSTRUCTION BTE MM 10/09/07 JOB NO.: 105-049 NO SCALE I - -y REVISION BY REVIEW DATE FILENAME: HAZEN-D-ELEC03 i i� m tt n