Loading...
HomeMy WebLinkAboutWTR2703214.15ELECTRICAL EQUIPMENT LEGEND ITEM DESCRIPTION MANUFACTURER PART NO. BY OTHERS SURGE PROTECTIVE DEVICE - SURGE PROTECTIVE UNIT WITH INNOVATIVE TECHNOLOGIES PTXl60-lS101-SD-D INTEGRAL DISCONNECT SWITCH IN A NEMA 4X ENCLOSURE.. OR EQUAL CONDUIT AND WIRING PER MANUFACTURER'S RECOMMENDATIONS. LIGHTING PANELBOARD - NEMA 1 ENCLOSURE, SERVICE ENTRANCE SIEMENS TYPE Pl O RATED, 200 AMP MAIN CIRCUIT BREAKER, 50 AMP BACK -FED OR EQUAL EMERGENCY GENERATOR CIRCUIT BREAKER, MECHANICAL INTERLOCK BETWEEN MAIN CIRCUIT BREAKER AND EMERGENCY GENERATOR CIRCUIT BREAKER, 240/120 VOLT, 10, 3 W, 30 CIRCUIT. MOUNT TOP OF ENCLOSURE 6'-0" FROM FLOOR. © INTRUSION ALARM SWITCH - HEAVY DUTY INTRUSION ALARM SWITCH. SQUARE D TYPE C, CLASS CONTRACTOR TO SELECT PLUNGER STYLE ACTUATOR. 9007 OR EQUAL PHOTO ELECTRIC SMOKE DETECTOR - 24 VDC, WITH LOCAL AUDIBLE SYSTEMS SENSOR 4WTAR-B OR O ALARM SIGNAL AND CONTACTS FOR REMOTE ANNUNCIATION EQUAL THROUGH FOUR WIRE CONNECTION TO TELEMETRY. INSTALL AT HIGHEST POINT. WIRE PER MANUFACTURER'S INSTRUCTIONS. PROVIDE I ACCESSORIES AS NECESSARY TO COMPLETE A FUNCTIONAL CIRCUIT. WALL MOUNTED COOLING THERMOSTAT - SNAP ACTION, SPDT LINE HONEYWELL T631C1103 OR OE VOLTAGE AIR SWITCH CONTROLLER. RANGE:30' - 100'F, SET AT EQUAL 757. MOUNT 4 FEET ABOVE FINISHED FLOOR. © KEYED -SWITCH BOX. SEE SPECIFICATIONS DWG NO. E02 FOR MORE INFORMATION. H O RESERVOIR LEVEL TRANSMITTER - SEE SPECIFICATIONS AND DWG NO. E04 FOR MORE INFORMATION. I O RESERVOIR OVERFLOW LEVEL SWITCH - SEE SPECIFICATIONS AND DWG NO. E04 FOR MORE INFORMATION. L O LIGHTING LIMIT SWITCH - HEAVY DUTY LIMIT SWITCH. ONTRACTOR SQUARE D TYPE C, CLASS TO SELECT PLUNGER STYLE ACTUATOR. 9007 OR EQUAL O FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 VA. SEE OMEGA MODEL LVN-20 OR EQUAL DWG NO. E04 FOR DETAIL. ON TELEMETRY PANEL, "RTU" REID INSTRUMENTS REID INSTRUMENTS OO GENERATOR CONNECTION RECEPTACLE - 50 AMP, 120/240 VOLT, 1-PHASE, 3-WIRE, TWIST LOCK MALE RECEPTACLE, GENERAL ELECTRIC T050N OR EQUAL MOUNT TOP OF ENCLOSURE 5'-0" FROM FINISHED GRADE. * CONTRACTOR SHALL INSTALL ALL EQUIPMENT PROVIDED BY OTHERS. FACILITY LIGHTING FIXTURE SCHEDULE MANUFACTURER * LAMP TYPE DESCRIPTION NAME CATALOG NO. QTY. CATALOG NO. REMARKS FLUORESCENT LIGHT FIXTURE, 120 VAC, 4' LONG, HIGH -IMPACT Al ACRYLIC LENS, MOLDED FIBERGLASS REINFORCED POLYESTER HOUSING, LITHONIA VRI 2 32 ARDP 120 CW 2 32WT8 (2)-32W LAMPS, ENERGY SAVING BALLAST, CEILING MOUNTED, U.L. 32 WATT LISTED FOR DAMP LOCATIONS. FLUORESCENT OUTDOOR AREA LIGHT - 42W, 120V BALLAST, A2 DIE-CAST ALUMINUM HOUSING, POLYCARBONATE LENS; U.,L, LISTED LITHONIA TWH 2/42 120 PE LPI 2 42 WATT PHOTO AND MOTION FOR WET LOCATIONS. MOUNT BOTTOM OF FIXTURE 7 -2 FROM FINISHED GRADE. RESERVOIR ROOF METAL HALIDE POLE MOUNT OUTDOOR FLOOD LIGHT: A3 FIXTURE - 120V 20OW PULSE START, METAL HALIDE LAMP, STANDARD LITHONIA KFL3-20OM-HPN-120-TS-SCWA-LPI 1 200 WATT DARK BRONZE FINISH, SUPER CWA PULSE START BALLAST. FURNISH POLE: METAL WITH TENON SLIPFITTER FOR POLE MOUNTING TO SPECIFIED POLE AND RSS-10-4B-T20 HALIDE I ON 10 FOOT TALL 4" ROUND POLE. MARINE QUARTZ FLOODLIGHT - 50OW, 120 VAC, 11 7/16" 500 WATT A4 H, 8 13/16" W, 6 15/16" D, COPPER FREE ALUMINUM, PHOENIX MS 500 QH 1 QUARTZ MARINE RATED, U.L. LISTED FOR WET LOCATIONS. HALOGEN A5 OUTDOOR AREA POLE -MOUNTED FLOODLIGHT- QUARTZ LIGHT HUBBELL LIGHT: QD-150W 150 WATT FIXTURE, 120 VAC, 150 WATT, DIE-CAST ALUMINUM HOUSING, LIGHTING POLE: 1 QUARTZ WITH CAST GUARD, ADJUSTABLE SWIVEL KNUCKLE. FURNISH SSS-16-50-7-TA-B WITH TENON SUPFITTER FOR POLE MOUNTING TO SPECIFIED POLE. OUTDOOR LOW -MOUNT FLOODLIGHT- INCANDESCENT LIGHT FIXTURE, A6 120 VAC, 150 WATT, DIE-CAST ALUMINUM HOUSING, 150 WATT POLYCARBONATE LENS, U.L. LISTED FOR WET LOCATIONS, SURFACE LITHONIA KLI A 120 LPI BBW DBL 1 INCANDESCENT j MOUNT TO STAIRWAY RAILING PER DETAIL ON DWG NO. E06. i * NUMBER OF LAMPS PER FIXTURE HAZEN RESERVOIR PANEL SCHEDULE LOCATION: LIGHTING PANEL SERVING: RESERVOIR 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 AB 11 )�200A 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 120/240 200 AMP VOLTS 3 WIRE MAIN CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION RESERVOIR LIGHTING 1.36 20 50 - EMERGENCY GENERATOR TVSS 4.71 30 2P 2P 20 0.50 TELEMETRY PANEL VENTILATION FAN 0.35 20 20 0.25 ELECTRICAL BUILDING LIGHTING ELECTRICAL BUILDING RECEPTACLES 0.70 20 20 0.70 RESFP'`nlP QFr'FPTACLE SEINER RECEH i Ai,LL OUTDOOR LIGHTING MOTORIZED GATE OPERATOR 1.92 20 20 0.50 OUTDOOR LIGHTING CONTROL PNL 0.10 20 20 0.35 METER VAULT SUMP PUMP 0.70 20 20 1.92 SEISMIC CONTROL VALVE SEISMIC VALVE VAULT SUMP PUMP 0.70 20 20 SPARE - 20 20 - SPARE SPARE - 20 20 - SPARE SPARE - 20 20 - SPARE SPACE - - - - SPACE SPACE - - - - SPACE SPACE - - - - SPACE CONNECTION LOAD: DEMAND: LIGHTING & MISC. LOAD DEMAND LOAD: KVA AMPS KVA AMPS POWER CONDUIT SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES P1 UTILITY TRANSFORMER UTILITY METER 2 1/2" (2) - #3/0, (1) - #3/0 N P2 UTILITY METER LIGHTING PANELBOARD, "L" 2 1/2" (2) - #3/0, (1) - #3/0 N P3 LIGHTING PANELBOARD, "L" GENERATOR CONNECTION RECEPTACLE 1" (2) - #8, (1) - #8 N, (1) - #10 GRD P4 LIGHTING PANELBOARD, "L" TVSS 3/4" (2) - #10, (1) - #10 N, (1) - #10 GRD P6 LIGHTING PANELBOARD, "L" TELEMETRY PANEL, "RTU" COOLING THERMOSTA EXHAUST FAN, "EF-1" INTAKE LOUVER ACTUATOR, "LA-l" 1/2" (2) - #12, (1) - #12 GRD P7 LIGHTING PANELBOARD, "L" 1/2- (2) - #12, (1) - #12 GRD P8 COOLING THERMOSTAT 1/2" (2) - #12, (1) - #12 GRD i P9 COOLING THERMOSTAT 1/2" 1/2" (2) - #12, (1) - #12 GRD (2) - #12, (1) - #12 GIRD P10 LIGHTING PANELBOARD, "L" ACCES `TF '"nT �''� An�� b r,"� P11 OUTDOOR LIGHTING CONTROL PANEL ACCE - GATE SITE LIGHTING AND MOTION DETECTOR 1" (4) - #12, (1) - #12 GRD P12 OUTDOOR LIGHTING CONTROL PANEL PARKING AREA SITE LIGHTING 3/4" (2) - #12, (1) - #12 GRD 13 LIGHTING PANELBOARD, "L" RESERVOIR LIGHTING 1" (2) - #12, (1) - #12 GRD P13B LIGHTING PANELBOARD, "L" RESERVOIR RECEPTACLE 1" (2) - #12, (1) - #12 GRD P14 LIGHTING PANELBOARD, "L" SEWER TELEMETRY RECEPTACLE 1/2" (2) - #12, (1) - #12 GRD RECEPTACLE LOCATED AT TOP OF RESERVOIR P15 LIGHTING PANELBOARD, "L" SEISMIC CONTROL PANEL 1/2" (2) - #12, (1) - #12 GRD P16 ACCESS GATE MOTORIZED OPERATOR GATE ENTRY KEYPAD 1" (4) - #14, (1) - #14 GRD P17 LIGHTING PANELBOARD, 1" METER VAULT SUMP PUMP 1/2" (2) - #12, (1) - #12 GRD P18 LIGHTING PANELBOARD, "L" SEISMIC VALVE VAULT SUMP PUMP 1/2" (2) - #12, (1) - #12 GRD CONTROL CONDUIT SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES C1 ELECTRICAL BLDG. INTRUSION SWITCH TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD C2 ELECTRICAL BLDG. INTRUSION DISABLE TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD C3 ELECTRICAL BLDG. SMOKE DETECTOR TELEMETRY PANEL, "RTU" 1/2" (4) - #14, (1) - #14 GRD C4A RESERVOIR TELEMETRY JUNC11ON BOX NO. 1 TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD CIRCUITS "C0" AND "C413" SHARE CONDUIT CONDUIT "C4" C4B RESERVOIR TELEMETRY JUNCTION BOX NO. 1 TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD CIRCUITS "C4A" AND "C4B" SHARE CONDUIT CONDUIT "C4" C5 RESERVOIR VANDAL SHIELD INTRUSION SWITCH TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD C6 SEISMIC CONTROL PANEL TELEMETRY PANEL, "RTU" 1" (12) - #14, (1) - #14 GRD C7 RESERVOIR ACCESS HATCH INTRUSION SWITCH RESERVOIR TELEMETRY JUNCTION BOX NO. 2 1/2" (2) - #14, (1) - #14 GRD C8 RESERVOIR OVERFLOW SWITCH RESERVOIR TELEMETRY JUNCTION BOX NO, 2 1" MANUFACTURER FLOAT CABLE C9 SEISMIC CONTROL PANEL SEISMIC VALVE SOLENOID AND LIMIT SWITCH 1 1/4" (3) - #6, (3) - #14, (1) - #6 GRD C10 SEISMIC VALVE VAULT FLOOD SWITCH TELEMETRY PANEL, "RTU" 1/2" (2) - #14, (1) - #14 GRD C11A RESERVOIR TELEMETRY JUNCTION BOX NO, 2 RESERVOIR TELEMETRY JUNCTION BOX NO. 1 1/2" (2) - #14, (1) - #14 GRD CIRCUITS "CllA" AND "CllB" SHARE CONDUIT CONDUIT "Cll" C11B RESERVOIR TELEMETRY JUNCTION BOX NO. 2 RESERVOIR TELEMETRY JUNCTION BOX NO. 1 1/2" (2) - #14, (1) - #14 GRD CIRCUITS "CllA" AND "CllB" SHARE CONDUIT CONDUIT "C1l" INSTRUMENTATION CONDUIT SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE' (QUANTITY) rONDINICTORS NOTES J1 RESERVOIR TELEMETRY JUNCTION BOX N0. 1 TELEMETRY PANEL, "RTU" 3/4" -- - - -'ABLE JUNCTION BOX LOCATED ON RAILING AT TOP OF RESERVOIR. SEE DWG N0. E03. J2A INLET FLOW METER TELEMETRY PANEL, "RTU" 2 1/2" (1)-2-CONDUCTOR SHIELDED CABLE CIRCUITS "J2A", "J2B", "J2C", "J21)", AND "J2E" SHARE CONDUIT CONDUIT "J2" J2B INLET FLOW METER (TOTALIZER AND POWER) TELEMETRY PANEL, "RTU" 2 1/2" (4) - #14, (1) - #14 GRD CIRCUITS "J2A", "J2B", "J2C", "J21)", AND "J2E" SHARE CONDUIT CONDUIT "J2" J2C OUTLET FLOW METER TELEMETRY PANEL, "RTU" 2 1/2" (l)-2-CONDUCTOR SHIELDED CABLE CIRCUITS "J2A", "J2B", "J2C", "J2D", AND "J2E" SHARE CONDUIT CONDUIT "J2" J2D OUTLET FLOW METER (TOTALIZER AND POWER) TELEMETRY PANEL, "RTU" 2 1/2" (4) - #14, (1) - #14 GRID CIRCUITS "J2A", "J2B", "J2C", "J21)", AND "J2E" SHARE CONDUIT CONDUIT "J2" J2E METER VAULT FLOOD SWITCH TELEMETRY PANEL, "RTU" 2 1/2" (2) - #14, (1) - #14 GRD CIRCUITS "J2A", "J2B", "J2C", "J2D", AND "J2E" SHARE CONDUIT CONDUIT "J2" J3 RESERVOIR LEVEL TRANSMITTER RESERVOIR TELEMETRY JUNCTION BOX NO, 2 1" MANUFACTURER LEVEL TRANSDUCER CABLE J4 STUB -UP ALONG INSIDE BUILDING WALL SPARE CONDUIT HANDHOLE (2)-2" PULL CORD (EACH) (2) SPARE CONDUITS. J5 STUB -UP ALONG INSIDE BUILDING WALL SPARE CONDUIT HANDHOLE (3)-3" PULL CORD (EACH) (3) SPARE CONDUITS. J6 STUB -UP ALONG INSIDE BUILDING WALL STUB -UP ALONG UTILITY POLE 4" PULL CORD RESERVE FOR RENTON INFORMATION SERVICE DEPARTMENT J7 SPARE CONDUIT HANDHOLE STUB -UP BELOW GATE ENTRY KEYPAD AND CAP 2" PULL CORD RESERVE FOR FUTURE WATER DEPARTMENT SURVEILLANCE. J8 STUB -UP ALONG INSIDE BUILDING WALL TOP OF RESERVOIR (2)-2" PULL CORD (EACH) RESERVE FOR FUTURE WATER DEPARTMENT SURVEILLANCE J9 STUB -UP ALONG INSIDE BUILDING WALL TOP OF RESERVOIR (2)-2" PULL CORD (EACH) RESERVE FOR RENTON INFORMATION SERVICE DEPARTMENT. IS DEPARTMENT CONDUIT SYSTEM (2)-3" ALL CONDUIT ROUTES MUST CONTAIN A MINIMUM OF 24" DIAMETER SWEEPS. J10 RESERVOIR TELEMETRY JUNCTION BOX NO. 2 RESERVOIR TELEMETRY JUNCTION BOX NO. 1 3/4" (1)-2-CONDUCTOR SHIELDED CABLE JUNCTION BOX LOCATED ON RAILING AT TOP OF RESERVOIR. SEE DWG NO. E04. VENTILATOR SCHEDULE NO. FLOW FLOWRATE BACKDRAFT DAMPER MANUFACTURER MODEL ACCESSORIES EF-1 EXHAUST 410 SCFM YES ACME ENGINEERING F0098 BACK GUARD LOUVER AND DAMPER SCHEDULE NO. FLOW FLOW RATE (SCFM) MANUFACTURER DAMPER, LOUVER DIMENSIONS ACCESSORIES* NOTES LA-1 INTAKE 410 POTTORFF CD42, EFD-445 12" X 12" MOUNTING SLEEVE, MOTORIZED ACTUATOR DAMPER TO OPEN ON EF-1 STARTUP LA-2 EXHAUST 410 POTTORFF CD42, EFD-445 12" X 12" MOUNTING SLEEVE, MOTORIZED ACTUATOR DAMPER TO OPEN ON EF-1 STARTUP * MOUNTING SLEEVES DEPTH SHOULD BE 18" MAX. Wm321438 REVISED TO CONFORM 7 rTR CORDS 06/08/09 RH ENGINEERING INC. DATE REVISED TO CONFORM TO CONSTRUCTION RECORDS ADDENDUM / ISSUED FOR CONSTRUCTION NO. REVISION H. WA 6727 6727_. 1 WAT. 'p- SIGNED: 06129107 SIGNED: 06129107 z 0 FNI Z04 W Oz �z V 0 cf) W J D 0 W U cn J Q V w J W 1 ENGINEERS 1 RH2 ENGINEERING. INC. http: /J/www.rh2 com mailbox@rh2.com 1.800.720.8052 BELL.INGHAM OFFICE 360.E 76.0836 454 West Horton Road BOTHELI. OFFICE 425, 951.5400 12100 NE 195th Street, Suite 100 EAST WENATCHEE OFFICE 509,886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsop Street, Suite 101 SHOWN ;446N44;�;1_ 1 DRAWING IS NOT1 SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG N0, ENGINEER: GMR E05 REVIEWED: MLM DATE: SEP 14, 2009 SHEET NO. DY KJS 06/08/09 CLIENT: REN BTE MM 10/09/07 JOB No.: 105-049 734 BY REVIEW DATE FILENAME: HAZEN-D-ELEC04 a8: 0- :3 14 3T