Loading...
HomeMy WebLinkAboutWTR2703226.90 I 0 c:)z o 6 z FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929 AND MUELLER SUPER CENTURION 200 WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORTZ ADAPTOR, 4" SEATTLE THREAD X 5" STORTZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT No. 43-655 SAFETY YELLOW OR APPROVED EQUAL. MIN MAX 4" PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. �r CONCRETE BLOCKING —18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. 57 EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH 0 REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED (SEE DWG BR46 / PAGE B090). RAISED PAVEMENT MARKER TYPE 88 A8 STIMSONITE TWO-WAY BLUE. 42" MIN CONCRETE BLOCKING BURY CAST IRON TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT TWO 3/4" / STEEL TIE RODS. SEE STD DETAIL FOR TIE RODS. 16" x 8" x 4" MININUM J CONCRETE BLOCK 1 3 CU. YD. WASHED DRAIN ROCK 3 TO 3/8") UNDER HYDRANT / ( DNE MAN ROCK- 6 CUT HYDRANT LOCATION IN CUT OR FILL MARKER 1-4 TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) MARKER FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) MARKER HYDRANT MARKERS FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND MIN 3' RADIUS qIL FILL MARKER I • F_ ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET uEC._" FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) FIRE HYDRANT ASSEMBLY DETAIL ADOPTED 01�~ C1TY OF RENTON �cp 91'ANDARD FIANS LST DATE: 12/96 DWG. NAME: BR24 SP PAGE: B 102 >tiX' 7" _ 4" RAISED PAVMENT MARKER TYPE 88 AB STIMSONITE TWO—WAY (BLUE) HYDRANT MARKERS ADOPTED C1TY OF RZNTON STANDARD PLANS Urr DATE: 12/96 DWG. NAME: BR24A SP PAGE: B103 CONCRETF DEAD MAN BLOCKING WITH SHACKLE RODS TO CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED EARTH, SIZE OF HLOCK TO BE DETERMINED BASED ON TEST PRESSURE OF WATER LINE AND SOIL CHARACTERISTICS. CAST IRON CAP OR PLUG WITH 2" �IPS TAP SHALL BE A ROCKWELL 482 END CAP COUPLING. WATER MAIN I 2" GALVANIZED IRON PIPE AS REQUIRED. 2" CLOSE NIPPLE =2" 2" 90' ELBOWGALVANIZED IRON PIPE, 12" LONG. PLAN TWO PIECE CAST IRON VALVE BOX EQUAL TO RICH VALVE CO. STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. 2" GALVANIZED IRON PIPE 12" LONG VALVE NUT EXTENSION IF REQUIRED (SEE DWG BR46 / PAGE B090) INSTALL 2" 90' ELBOW, SCREWED 2" PLUG, SCREWED 18" 2" GALVANIZED IRON PIPE A� REQUIRED. 2" GATE VALVE, SCREWED INSTALL 2" 90• ELBOW, SCREWED ELEVATION 2" GALVANIZED IRON PIPE AS REQUIRED, 12"x 22" CONCRETE METER BOX WITH 3/16" STEEL DIAMOND PLATE COVER EQUAL TO FOG TITE METER SEAL CO. B-10 METER 6" BOX.-:�, MIN FINISH GRADE 9" MAX 1 9" 3- d.Ja21 " M I N COVER 36" MIN COVER �22-1 /2• NEW DUCTILE IRON L LOOP DOWN TO CENTERLINE WATERMAIN OF WATER MAIN TO PROVIDE SLACK IN COPPER SERVICE LINE TO METER. CORPORATION STOP. FORD TAPERED THREAD (CC). PACK JOINT (3/4" F1000) (1" F1000) 22-1 /2' TEMPORARY 2" BLOW —OFF ASSEMBLY ADOPTED � ri� C1TY OF RENTON �ciW STANDARD PIANS I.4T DATZ: 12/96 DWG. NAME: BR25 SP PAGE: B l 04 I I w . IN UNIMPROVED RIGHT OF WAY u . Z INSTALL METER BOX AT z PROPERTY LINE. of j a o a SIDEWALK a WATER METER TO BE —i 12" MIN -- SUPPLIED BY THE CITY _ 36" MIN COVER TYPE "K" SOFT COPPER TUBING FORD COPPERSETTER VH 72-15W-44-33G (FOR 5/8" x 3/4" METER) VH 72-15W-44-44G (FOR 1" METER) BOTH INLET AND OUTLET WITH PACK JOINT WITH GRIT PADLOCK WINGS ON KEY VALVE SINGLE CHECK VALV' ON OUTLET. ALL PACK —JOINT FITTINGS SHALL BE WITH GRIPPER. FOR SERVICE FROM EXISTING STEEL EXISTING CAST IRON ASBESTOS CEMENT OR PVC WATER MAINS OR DUCTILE IRON INSTALL DOUBLE STRAP SERVICE CLAMP WATERMAIN EQUAL TO MUELLER CO. IF SERVICE LINE TO HOUSE IS TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR 44 FIDT x COMPRESSION COUPLING 3/4" OR 1" GALVANIZED PLUG lw,w -1w, *4 4?264000 3/4" do i" WATER SERVICE ADOPTED / C1TY OF RENTON ♦I STANDARD PLANS LST DATE: 12/96 DWG. NAME: BR41 SP PAGE: Bl06 PE r O WAs� 8�0 �� F WASIrI 7 1 � 1 SSIONAL� 1+° SSIONAL EXPIRES 3/19/07 EXPIRES 07/20/06 SURVEYED: SCALE: DATE: • 1 "— r " HORIZONTAL: NAD 1983/1991 111001 ► DESIGNED: —20 —O '% - CITY OF WATER MAIN REPLACEMENT RELDBOOK: Engineering Planning Surveying RENTON WILLIAMS AVENUE S. PAGE: -� Penhallegon Associates Consulting Eengineers, Inc. 2 PERMIT RESUBMITTAL JS 2/14/05 DBH DRAWN:. ONE INCH DATUM S. 2ND STREET TO S. RIVERSIDE DRIVE DRAINING 1NO: 750 Sixth Street Scuts Kirkland, WA 98033 www.pcceengrs.com 1 PERMIT RESUBMITTAL JS 1/10/05 DBH CHECKED: AT 1 3.3 PH: 425) 827-2014 1-800-945-8408 FAX: (425) 827-5043 IF NOTAppROypp; LONE�INr, SCALE ACCORDINGLY 7y GrePlanning/Building/Public Works Dept. STANDARD DETAILS SHEET: V OF: NO. REVISION BY DATE APPR ��ryryryry Zimmerman P.E., Administrator 4 4 Kirkland a Seattle l W �J 2•uS�yT��.1 ��'' *-ANNE0 A P k '' 2