GENERAL NO TES
1. BEFORE ANY CONS7RUC7701V OR DEVELOPMENT AC77V1TY OCCURS, A
PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF
RENTON PUBLIC WORKS, DESIGN ENGINEER.
2 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LA TEST EDI77ON
OF STANDARD SPECIF7CA 77ONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY W.S.D.O. T., AND THE AMERICAN
PUBLIC WORKS ASSOCIA7701V (APWA), AS AMENDED BY 774E 0TY OF
RENTON DEPAR7MENT OF PUBLIC WORKS
J THE STORM DRAIN SYSTEM SHALL BE CONS7RUCTSD ACCORDING TO 774E
APPROVED PLANS WHICH ARE ON FILE IN 774E DEPARTMENT OF PUBLIC
WORKS ANY DEVIA77ON FROM THE APPROVED PLANS WILL REQUIRE
WRiTTFN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF
PUBLIC WORKS, DESIGN ENGINEER OR STORM WA TER U77LI TY.
4. A COPY OF THESE APPROVED PLANS MUST BE ON 774E JOB S17F
WHENEVER CONS7RUC7701V IS IN PROGRESS.
5. DATUM SHALL BE U.S.G.S UNLESS 07HERWISE APPROVED BY 174E
CITY OF RENTON DEPARTMENT OF PUBLIC WORKS REFERENCE BENCHMARK
AND ELEVA77ONS ARE N07ED ON THE PLANS
6. ALL SEDIMENTA 770N/EROSION FACIU77ES MUST BE 1N OPERA 77ON
PRIOR TO CLEARING AND BUILDING CONSTRUC770N, AND 774EY MUST
BE SA 77SFACTORIL Y MAINTAINED UN77L CONS7RUC7ON IS COMPLETED
AND 174E P07EN77AL FOR OIVS17E EROSION HAS PASSED.
7 ALL RE7EN770N1DE7ENl7ON FACiLIRES MUST BE INSTAL ED AND IN
OPERA77ON PRIOR TO OR IN CONJUNC77ON WI774 ALL CONSTRUCTION
AC77WTY UNLESS OTHERWISE APPROVED BY 774E DEPARTMENT OF
PUBLIC WORKS, STORM WATER U77LITY
8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. 774E GRASS SEED
MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES,
SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY
THE DEPARTMENT OF PUBLIC WORKS, STORM WATER U77LITY.
9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY
PREPARED FOUNDA RON IN ACCORDANCE W1774 SEC77ON 7-02. 3(1) OF
774E CURRENT STATE OF WASHINGTON STANDARD SPECIFICA77ON FOR
ROAD AND BRIDGE CONSTRUC770N. 7141S SHALL INCLUDE NECESSARY
LEVELING OF 174E TRENCH BOTTOM OR THE TOP OF THE FOUNDA RON
MATERIAL AS WELL AS 774E PLACEMENT AND COMPAC7ION OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE EN77RE LENGTH
OF 774E PIPE WILL BE SUPPOR7ED ON A UNIFORMLY DENSE UNYIELDING
BASE ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE
EXCEP7701V OF PVC PIPE. ALL 7RENCH BACKFILL SHALL BE
COMPACTED TO MIN. 959 FOR PA VEMENT AND S7RUC7URAL FILL AND
9OX OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL
BE 6" UNDER AND OVER P. V.C. PIPE.
m: 4z!
h;hmim mc,
1 - #3 BAR
5'
2 - #3 BAR HOOP
#3 BAR EACH CORNS
#3 BAR EACH Sh
#3 BAR EACH WA
CA T cH BA SIN
m
10. GALVANIZED STEEL AND ALUMINIUMIZED STEEL PIPE FOR ALL
DRAINAGE FACILITIES SHALL HA VE ASPHAL T 7REA 1MENT 11 OR BETTER
INSIDE AND OUTSIDE.
11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10' FEET OF THE
SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15' FEET FROM THE
TOP OF ANY CHANNEL BANK.
12. ALL CA TCH BASIN GRA TES SHALL BE DEPRESSED 0.10' FEET BELOW
PAVEMENT LEVEL.
13. OPEN CUT ROAD CROSSINGS THROUGH EXIS77NG PUBLIC RIGHT-OF-WAY
WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY
OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
14. ROCK FOR EROSION PR07EC77ON OF ROADSIDE DITCHES, WHERE
REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF
1' FOOT AND MUST MEET THE FOLLOWNG SPEORCA770NS.°
4"-8"/40X-70X PASSING; 2'"-4" ROCK/309'-40Z PASSING; AND -2"
ROCK/10%20X PASSING.
15. ALL BUILDING DOWNSPOUTS AND F0077NG DRAINS SHALL BE
CONNEC7ED TO 774E STORM DRAINAGE SYS7EM, UNLESS APPROVED BY
THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM
WATER U77LITY. AN ACCURATELY DIMENSIONED CERTIFIED
"AS -BUILT" DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED
TO THE CITY OF RENTON UPON COMPLETION.
16. ISSUANCE OF THE BUILDING OR C01VS7RUC7701V PERMIT BY THE CITY
OF RENTON DOES NOT RELIEVE THE OWNER OF 174E CON77NUING LEGAL
OBLIGA 77ON AND/OR LIABILITY CONNECTED Wf TH STORM SURFACE
WATER DISPOSI77ON. FUR7HER, THE CITY OF RENTON DOES NOT
ACCEPT ANY C19LIGA77ON FOR 7HE PROPER FUNC770NING AND
MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE
SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS,
AND ANY OTHER NEEDED AC77ONS TO PROTECT 774E LIFE HEAL 7H, AND
SAFETY OF 774E PUBLIC, AND TO PR07ECT PROPERTY IN CONNEC770AI
WITH 774E PERFORMANCE OF WORK COVERED BY 7HE CONTRACT ANY
WORK WI774IN THE TRAVELED RIGHT-OF-WAY 774AT MAY IN7FRRUPT
NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC
CONTROL PLAN BY THE TRAFFIC ENGINEERING DIV OF 174E
DEPARTMENT OF PUBLIC WOKS ALL SEC7701VS OF THE If S.D.O. T
-07-23, 7RAFf7C CONTROL, SHALL STANDARD SPECIRCA77ONS 1
APPL Y.
18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF 7HE PROL-CT
LOCA770N IS W774IN THE AQUIFER PR07EC77ON AREA.
FRAME AND GRATE
S.. 6" RISER SECTION
6"
s�-
12" RISER SECTION
12'
4" MIN
PRECAST BASE SECTION
d (MEASUREMENT A T THE TOP
d OF 774E BASE)
TYPE 1
ALTERNATE 2
WHEN THERE IS NO PLANTING STRIP
EXPANSION JOINTS
SEE NOTE 2
6'
MIN o
Y O
U
a
1 1 a
'- p °a
6" RESIDENTIAL
10" COMMERCIAL OR
INDUSTRIAL
CURB AND GUTTERill SEE DETAIL "A"
SHOWN HOWEVER,
OTHER CURBS MAY
BE USED (SEE SECTI❑N A -A
STANDARD PLANS)
DRIVEWAY OR ALLEY
RESIDENTIAL: 10' MIN, TO 20' MAX.
COMMERCIAL: 15' MIN, TO 30' MAX.
INDUSTRIAL 15' MIN. TO 50' MAX,
A�
��SIDEWALK
4"
-EXPANSI❑N J❑INT
SCORE LINE
_t
DETAIL A
APPROACH WITH
MONOLITHIC CURB
SEE NOTE 5
NOTE:
1. DUMMY J❑INTS SHALL BE PLACED NOT TO EXCEED 15' C/C NOR LESS THAN 10' C/C. THEY SHALL
NOT BE LESS THAN 3/16" IN THICKNESS AND SHALL EXTEND 2-1/4" DEEP,
2. 1/2" THRU JOINTS SHALL BE PLACED AT BACK, SIDES AND FRONT (BEHIND CURB) OF APPROACH.
3. CEMENT CONCRETE SHALL BE CLASS 3000 AIR ENTRAINED
4. ALL JOINTS SHALL BE CLEANED AND EDGED,
5, APPROACH SHALL NOT BE POURED INTEGRAL WITH CURB AND GUTTER, BUT MAY BE POURED
INTEGRAL WITH STANDARD CURB (SEE DETAIL "A").
6. SUBGRADE COMPACTION SHALL BE 95% MODIFIED PROCTOR.
CEMEN T C01VCRE TE DRI VE WA Y
OR ALLEY APPROACH
42" MAX
24" MIN
5" {
2-1/2M L
1-1
STD 90` BRACKET OR 360°
ADJUSTABLE BRACKET IF
REQUIRED.
1. CATCH BASIN TO BE CONSTRUCTED IN ACCORDANCE WITH ASTM C 478
(AASHTO M 199) & ASTM C 890 UNLESS OTHERWISE SHOWN ON PLANS
OR NOTED IN THE STANDARD SPECIFICATIONS.
2. AS AN ACCEPTED ALTERNATE TO REBAR, WELDED WIRE FABRIC HA WNG
A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED.
WELDED WIRE FABRIC SHALL COMPLY TO ASTM A 497 (AASHTO M
221), WIRE FABRIC SHALL NOT BE PLACE IN THE KNOCKOUTS
J. THE BOTTOM OF THE PRECAST BASE SECT70N MA Y BE ROUNDED.
4. PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS
KNOCKOUTS SHALL HA VE A WALL THICKNESS OF 2" MINIMUM.
5. KNOCKOUTS MAY BE ON ALL 4 SIDES WITH MAXIMUM DIAMETER OF
20' KNOCKOU IS MA Y BE El THER ROUND OR "D " SHAPE. PIPE TO BE
INSTALLED IN FACTORY SUPPLIED KNOCKOUTS.
6. KNOCKOUTS OR CUTOUT HOLE SIZE IS EQUAL TO PIPE OUTER
DIAMETER PLUS CATCH BASIN WALL THICKNESS.
7. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO T74E PIPE INVERT
IS 5'_ 0"
8. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER
SEC T70N SHALL NOT EXCEED 112 "/FT
9. CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE WITH
STANDARD SPECIFICATIONS AND MEET 774E STRENGTH REQUIREMENTS
OF FEDERAL SPECIFICA77ON RR-F-621D. MATING SURFACES SHALL BE
FINISHED TO ASSURE NON -ROCKING FIT.
10. FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST
INTO RISER.
PIPE CAP
2" GALVANIZED
STEEL PIPE -
1 o'
CEMENT
1-1/2' CONCRETE
CLASS 'B'
3'
5/8th
MINUS '
1-1/2' CRUSHED
ROCK
e)C° l/ni ITV 0., ACAC`CA/CA/T
20' PA t
SEC TION
2. 0%
4 " COMPA C TED DEP TH CLASS "B" A SPHAL T
IN 2 - 2" LIFTS
6" COMPA C TED DEPTH - CRUSHED
SURFACING TOP COURSE
12" GRAVEL BASE AS NEEDED
8 FOR ALL ARTERIALS
2' MIN
LEARANCE FROI
FACE OF CURB.
10' MIN
CLEARANCE IF
NO CURB
GROUND MOUNTED S TREE T NAME SIGNS
DWG. GR03
2'0
�vw of WA q�
d
"AS -BUILT" NOTE:
"AS -BUILT" IS BASED ON A ACTUAL FIELD SURVEY ��o 9470 �w
BY TOUMA ENGINEERS AND INFORMATION SUPPLIED ISrER�
BY CONTRACTOR. �`��OKAL �
EXPIRES 6/22/07
R 3242�0
ROAD SECTION PRl VA TE DRl 1/EWA Y
N TS
2" CLASS
6.5' MIN.
1' 1' 2.5' 1' 1'
MIN MIN MIN MIN MIN
*
- At P ri ASS 'E' OR 'B'
6" CRUSHED
SURFACING TOP COURSE
CRUSHED ROCK,
FLOWABLE FILL
OR
AS REQUIRED BY ENGINEER
* SEE DWG# HR-05 FOR MINIMUM STANDARDS
TYPICAL PATCH FOR FLEXIBLE PA VEMENT
WHEN PERPENDICULAR TO
ROAD WA Y CEN TERLINE
TRENCHES FOR ROAD CROSSINGS
1. ANY AFFECTED LANE WILL BE GROUND DOWN 2 INCHES AND PAVED
FOR THE EN TIRE WID TH OF THE LANE.
2. IF THE OUTSIDE OF THE TRENCHING IS WITHIN THREE FEET OF ANY
ADJACENT LANE LINE, THE ENTIRE ADJACENT TRA VELED LANE AFFECTS
WILL BE PAVED. 1
NO SCALE
2"x4" POST MARKED
"DRAIN"
FINISHED GRADE 5
6" CAP W/THREADED
PLUG
6" PVC LENGTH
REQUIRED
1/8" BEND (6')
6" PVC EXTENSION
OF 6" PVC
OR CAP END
6"X6"WYE
FOR LOT DRAINAGE TO BE TIED TO
STORM DRAIN SYSTEM. PLACE
CLEANOUTS BY LOT CORNERS
AND "Y'S" IN THE PIPES.
TYPICAL CCEANOUT DETAIL
N. T.S.
RECOMMENDED
FOR APPROVAL
BY DATE
BY DATE
BY DATE
BY DATE
BY DATE
7 W.
9804SITE.DWG
SHEEN: 5 0` 12