Loading...
HomeMy WebLinkAboutWTR2703242.1 (2)0 o ga of =w Yn 3 C� z ot� CL TO z a: O V Lu Lu z w Lu Q z z z w of � M N (i�AJ � co .at cr � o 81 W 0 3 h o Q W w 2 U Q �J 4 0 i N a �o ~Z� 0UT U) e � �-J,wj,F-j W !loin iMills llll� z 0 Y) W o' z .0 CITY OF RENTON MON #1891 FOUND bnQ lIA/ C' AI A/A BRA SS DISK IN colvc IN CA SE Wirth x TION 0 Tl L_ I V v v 1 4', E 0 �3, T INIV ,�,� I v RGE 5 L � V,� INTER NE 22nd PL & UNION A VE NE (1/05 N= 189,5J8.161 ' --E=1,J4, 42J. 4JQ: I EL= 454.087` I NR7e17'dQ'"IA/ 1117 ate' -7 z , Ld Q ; z Oy z �o L0 w� Z 00 Of O N `... CJ 2+96-5'LT 1-45' BEND MJ EX WATER METER TO TO CUT _ CONC BLOC AND CAPPED BY CITY FORCES 2+90-51 T it NEW 6' A CCESS PRI VA TE 1- 45' BEND(MJ)- C_ i I FASEMENT TO BE SECURED CONC BLOCKING 18' N i F_� 5, ROM TAX LOT 196 6LF 8" DI CL52 29+46.22-18 RT UNION 1+18-51T CUT -IN BY CITY 1-12"X8" CUT -IN TEE(MJXFL) 1 0 I 1-8" GV (FLXMJ) u-)4 1-12" SLEEVE (MJ) in , 1-12"OX18" DI NIPPLE ' 1-8'„ VERT CROSS(MJXFL) �o o 2-8 BLIND FLANGE, ONE NE 22ND t _ - - - -` 0. TAPPED 2 W/2 PLUG 00 CONC BLOCKING, SEE STREET CONNECTION DETAIL SHT 50 MON /N CAE 29+24.98 UNION A VE NE I N i i O EX FH EX r P �J 77 z .6 -iLO ® O _ � z EX MON IN CASE W 114 CORNER SEC 3— 2J— 5 NE 19 TH STREET S87°44'14 "E (PLAT) UPDATE EX. FH AS REQUIRED EXIST FIRE HYDRANT TO BE RETROFITTED WITH STORTZ FITTING. "AS —BUILT NOTE: 4 ,a "AS -BUILT" IS BASED ON A ACTUAL FIELD SURVEY `� 9470 w� BY TOLIMA ENGINEERS AND INFORMATION SUPPLIED BY CONTRACTOR. S10NAL EXPIRES 6/22/07 20' PRIVATE INGRESS & EGRESS OVER LOT 1 26' PRI VA TE STREET WI TH 20' PAVED SECTION, DETAIL SHEET 6. 26' CITY OF RENTON & SA N. SEWER EAS'T. J+92-f4'L-P 59' L T 1-8" VERT CROSS(MJXFL) 2-BLIND FLANGES W/2"TAP & 2" PLUG 1-8" PLUG(MJ) 1-2" PERM BLOW OFF ASSEMBL Y ttv'. ' L t ` `'' CONC BLOCKING FRU`V T A P , _T A r L(_7KLJJ L qI )LMLN I UVLK 1-8" PLUG(M✓) LOT 1 1-8" GV(FLXMJ) CONC BLOCKING ..SEE PROFILE NEXT SHEET NOTE FILL AND COMPACT THE ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCA VA TION FOR WA TERMAIN AND FIRE HYDRANT INS TALLA TION. NO TE.' ALL TRENCH RESTORATION SHALL BE PER CURRENT CITY OF RENTON STREET 0VERLA Y AND TRENCH RESTORA TION DETAILS 1 - 8" PLUG (MJ) W774 2" TAP & 2" TEMP. BLOW -OFF ASSEMBL Y 1+18-5'LT CUT -IN BY CITY 1-12"X8" CUT -IN TEE(MJXFi 1-8" GV (FLXMJ) 1-12" SLEEVE (MJ) 1-12"OX18" DI NIPPLE 1-8" VERT CROSS(MJXFL) 2-8" BLIND FLANGE, ONE TAPPED 2" W/2" PLUG CONC BLOCKING, SEE COivivECiiOI`v DETAIL REMOVE EXIST. 6" GV INSTALL 6" BLIND FLANGE . EXISTING TEE 8" VERTICAL CROSS (MJxFL) 1 - 8" PLUG (MJ) WITH 2" TAP & 2" TEMP. BLOW -OFF ASSEMBLY 1 - 8" BLIND FLANGE(B01" 1 - 8" BLIND FLANGE(TOP) WITH 2" TAP & 2" PLUG TEMPORARY BLOCKING Z Z I � NEW 8" DIP �? PRI VA TE ROAD NEW 8" DIP PRI VA TE ROAD AFTER POL YPIGGING, PRESSURE & PURITY TEST, REMOVE TEMP. PLUGS, BLOCKING, AND CONNECT W/8" SOLID SLEEVE (MJ) TEST CONNECTION FINAL CONNECTION CONNEC 77ON DETAIL N. T. S NOTES 1. CONTRACTOR TO POTHOLE EXISTING WATERMAIN AT CONNECTION LOCH TIONS 2. CITY STAFF WILL MAKE ALL FINAL CONNECTIONS 15' CI TY OF REN TON SANNRY SEWER EASEMENT 20' PRI VA TE -STORY EASEMENT \ NO TE. \ MAXIMUM AVAILABLE FLOW RATE IS LIMITED TO 1250 GPM. GROSS BUILDING SQUARE FOOTAGE INCLUDING GARAGE MUST NOT EXCEED A TOTAL OF J, 600 SQ. FT. STATIC WATER PRESSURE f 48 PSI @ FF ELEV. = 448'. A/F 2n ry STREET S8TJ5'1 I �E J8J.10' RErOMMFNDFD,` FOR APPROVAL BY DATE BY DATE BY DATE BY DATE BY DATE I A y 15' PVT UTILITY EASEMENT 798004SITE. DWG SHED, 10 OF 12 IWIAITIL SCANNED OCT 2 7 200E A3 - w _ 2-4