HomeMy WebLinkAboutTED4003246.6REVISIONS
m
m
0)
Oo
U
o0
z
Y
�
o
Z
ui
m u
Q
W
Q
Q
S
a
0
n
Z
0
W
0
F
Fn
MM
W
Z
Q
Q
=J
VJ
Q
�
�-
W
wZ
o
W
c�
0
Z
V,r-r^
W
L
O
a+,
a) a
W
Z
0"
v,
00
y .c
3a
Z
��
I--
W
w
U
�CL:
a
me
c:
E
CN
C
a�
0
0
r
Ld
=J
JUZ.
Z
aZo
p
W
SOU
Z
O
�rQ
�O
rZJ
aLLa
J
�
U
-5
Q
J
0
p
�W
0
W
O
>
Z
W
W
Cf
V)
a
G_
U
O
U
Q
�
J
�-
w
J
d.
a
N
w
~
I
Q
�
a
U
�
�m
V)
F-
z
w
O
U
z
O
Of o
w V)
O S
Ld
>_ Of
F-
U
ry
w
a
0
w
V)
w
Of
(TYP)
Q-
ALTERNATE 2
SEC. 15, TWP. 23 N., RNG. 5 E., W.M.
CURB AND GUTTER SHOWN
HOWEVER, OTHER CURBS
MAY BE USED,
(SEE STANDARD PLANS)
SIDEWALK NEXT TO CURB 10" COMMERCIAL ZONE
(NO PLANTER STRIP) 6"
RESIDENTIAL ZONE
THICKENED
BASE OF CURB & GUTTER
TO
MATCH APPROACH THICKNESS
NOTES;
ON
COMMERCIAL APPROACHES, (TYP)
1.
DUMMY JOINTS SHALL BE PLACED NOT TO EXCEED 15' C/C NOR LESS THAN
10' C/C. THEY SHALL
NOT BE LESS THAN 3/16" IN THICKNESS AND SHALL BE 2-1/4" DEEP,
2.
1/2" THRU JOINTS SHALL BE PLACED AT BACK, SIDES AND FRONT (BEHIND
CURB) OF APPROACH,
AND IN CURB/GUTTER TO DUMMY JOINTS.
3.
CEMENT CONCRETE SHALL BE CLASS 3000 AIR ENTRAINED.
4.
ALL JOINTS SHALL BE CLEANED AND EDGED.
5.
APPROACH SHALL NOT BE POURED INTEGRAL WITH CURB AND GUTTER, BUT
MAY BE POURED
INTEGRAL WITH STANDARD CURB (SEE DETAIL "A").
6.
SUBGRADE COMPACTION SHALL BE 95% MODIFIED PROCTOR.
7.
APPROACH CENTERLINE TO MATCH THE DRIVEWAY/ALLEY CENTERLINE.
THE APPROACH WIDTH WILL BE 10' WIDER THAN THE DRIVEWAY/
ALLEY WIDTH,
21 MAXIMUM BACKSLOPE,
FOR A FLAT BACKSLOPE,
SURFACE SHOULD BE
IMPERVIOUS AND SLOPED
TO DRAIN.
PRELIMINARY PLAT APPROVAL CONDITIONS MITIGATION MEASURES:
1.
A GEOTECHNICAL ENGINEER SHALL DETERMINE THE SUITABILITY OF THE EXISTING ON -SITE FILL PRIOR TO ITS
USE ON -SITE. THE SATISFACTION OF THIS REQUIREMENT SHALL BE REVIEWED AND APPROVED BY
DEVELOPMENT SERVICES DURING CONSTRUCTION.
2.
AT THE TIME OF BUILDING PERMITS, ADDITIONAL GEOTECHNICAL STUDIES ADDRESSING THE SUITABILITY OF SITE
SOILS FOR USE AS STRUCTURAL FILL SHALL BE PREPARED AND SUBMITTED. THE SATISFACTION OF THIS
REQUIREMENT SHALL BE REVIEWED AND APPROVED BY DEVELOPMENT SERVICES,
6' MIN
3,
THE APPLICANT SHALL COMPLY WITH THE "GEOTECHNICAL ENGINEERING STUDY" PREPARED BY EARTH
2
Oa
O
CONSULTANTS, INC., DATED AUGUST 30, 2004, REGARDING SITE PREPARATION AND GENERAL EARTHWORK
(T�)
va
AND "UTILITY SUPPORT AND BACKFILL," THE SATISFACTION OF THIS REQUIREMENT SHALL BE REVIEWED AND
mQ
APPROVED BY DEVELOPMENT SERVICES DURING CONSTRUCTION, UTILITY WORK AND BUILDING CONSTRUCTION.
.,`
4.
THE PROJECT SHALL BE REQUIRED TO BE DESIGNED AND COMPLY WITH THE DEPARTMENT OF ECOLOGY'S
(DOE) EROSION AND SEDIMENT CONTROL REQUIREMENTS, OUTLINED IN VOLUME 11 OF THE 2001
�1 g"
STORMWATER MANAGEMENT MANUAL.
"A"
5,
ALL CONTRACTORS ARE TO BE MADE AWARE OF THE POTENTIAL PRESENCE OF ENVIRONMENTAL CONTAMINANTS
SEE
DETAIL
AND INSTRUCTED TO NOTIFY THE PROPERTY OWNER IMMEDIATELY, IF DISCOLORED, ODIFEROUS, OR OTHERWISE
SUSPECT SOIL IS ENCOUNTERED DURING EXCAVATION ACTIVITIES,
SECTION A -A
10/22/96
Edited graphics, text, Added note 7.
DCV
DRT
DATE
REVISION
BY
APPR
* SEE NOTES 1-3 FOR PERMIT AND
CERTIFICATION REQUIREMENTS.
1.0' DEPTH COVER
MINIMUM OF 16"
COMPACTED FILL SHOULD BE A
T r���A ..�GRANULAR SOIL AND COMPACTED
- - TO 957 MINIMUM, OF MAXIMUM
DRY DENSITY IN ACCORDANCE
® i
WITH ASTM D-1557-00 (MODIFIED
6 PROCTOR)
* HEIGHT
(MAX. 4.0) ®� ®® -TT
`�_
_PROVIDE GEOGRID REINFORCEMENT AS
RECOMMENDED BY THE GEOTECHNICAL
ENGINEER AS NECESSARY IN THE
STRUCTURAL FILL (SEE NOTE 8).
1' MINIMUM WIDTH OF FREE DRAINING
-- = FILTER ROCK. AS APPROVED BY THE
! I SOILS ENGINEER),
MINIMUM 4 DIAMETER PERFORATED
PVC PIPE WITH MIN, 1 % CONTINUOUS
SLOPE TO OUTLET. PIPE TO BE
1,0 MINIMUM WRAPPED WITH FILTER FABRIC,
HEIGHTREINFORCEMENT WIDTH
3
(MIN. - - = HEIGHT. (MIN. 9.0')
ROCKERY (IN FILL)
N. T. S.
-6„ 6. IF SUSPECT SOIL IS ENCOUNTERED DURING EXCAVATION ACTIVITIES, WORK IN THESE AREAS IS TO BE
JOINT 3/16' SCORE LINE STOPPED UNTIL SUCH TIME AS A QUALIFIED ENVIRONMENTAL PROFESSIONAL CAN ASSESS THE OBSERVED
CONDITIONS AND RECOMMEND CORRECTIVE MEASURES,
7, IF THE PRESENCE OF ENVIRONMENTAL CONTAMINANTS IS CONFIRMED WITHIN THE SUSPECT SOILS AT
CONCENTRATIONS EXCEEDING APPLICABLE MTCA CLEANUP LEVELS, THEN (A) THOSE SOILS ARE TO BE
y� HANDLED AND MANAGED IN ACCORDANCE WITH MTCA AND; (B) THE WORK WILL BE MANAGED AND
18" OVERSEEN BY A QUALIFIED ENVIRONMENTAL PROFESSIONAL AND PROPERLY DOCUMENTED AND REPORTED TO THE
DEPARTMENT OF ECOLOGY (DOE) IN ACCORDANCE WITH MTCA.
DETAIL A
APPROACH WITH 8. THE PROJECT SHALL COMPLY WITH THE 1998 KING COUNTY SURFACE WATER DESIGN MANUAL TO MEET
MONOLITHIC CURB BOTH DETENTION (LEVEL 2 FLOW CONTROL) AND WATER QUALITY IMPROVEMENTS,
SEE NOTE 5
9. THE APPLICANT SHALL PAY THE APPROPRIATE FIRE MITIGATION FEE BASED ON A RATE OF $488.00 PER
9 NEW SINGLE-FAMILY LOT. CREDIT TO BE GIVEN FOR THE EXISTING THREE RESIDENCES. THE FEE SHALL BE
PAID PRIOR TO THE RECORDING OF THE FINAL PLAT.
CEMENT CONCETE APPROACH 10. THE APPLICANT SHALL PAY THE APPROPRIATE TRAFFIC MITIGATION FEE BASED ON $75.00 PER EACH NEW
U
i ItAVERAGE DAILY TRIP ASSOCIATED WITH THE PROJECT. CREDIT TO BE GIVEN FOR THE EXISTING THREE
FOR DRIVEWAYS AND ALLEYS Ii.,z RESIDENCES. THE FEE SHALL BE PAID PRIOR TO THE RECORDING OF THE FINAL PLAT
ADOPTED �'`rtONpLQ 11. THE APPLICANT SHALL PAY THE APPROPRIATE PARKS MITIGATION FEE BASED ON $530.76 PER NEW
CITY OF RENTONSINGLE-FAMILY LOT. CREDIT TO BE GIVEN FOR THE EXISTING THREE RESIDENCES, THE FEE SHALL BE PAID
U
w PRIOR TO THE RECORDING OF THE FINAL PLAT.
STANDARD PLANS
LST DATE: 12/96 12, EVERGREEN AND DECIDUOUS TREES (I.E. DOUGLAS FIR, WESTERN HEMLOCK, AND BIG LEAF MAPLE) SHALL BE
PLANTED ON 15-FOOT CENTERS WITHIN THE 25-FOOT WIDE BUFFER ALONG THE EAST SIDE OF THE STREAM.
TWO -GALLON SIZE TREE STOCK SHALL BE USED, PLANTING SHOULD OCCUR IN THE FALL TO ALLOW PLANTS TO
DWC. NAME: FRO1 N SP PAGE: F006 DEVELOP ROOTS OVER THE WINTER THE SATISFACTION OF THIS REQUIREMENT SHALL BE SUBJECT TO THE
GENERAL NOTES
REVIEW AND APPROVAL OF THE DEVELOPMENT SERVICES DIVISION.
13. DURING SITE PREPARATION AND CONSTRUCTION OF IMPROVEMENTS AND RESIDENCES, THE APPLICANT SHALL
INSTALL SILT FENCING WITH BRIGHTLY COLORED CONSTRUCTION FLAGS TO INDICATE THE BOUNDARIES OF THE
STREAM/CREEK BUFFER. THE SATISFACTION OF THIS REQUIREMENT SHALL BE SUBJECT TO THE REVIEW AND
APPROVAL OF THE DEVELOPMENT SERVICES DIVISION AND BE COMPLETED PRIOR TO THE ISSUANCE OF
CONS TRUCTION/UTILI TY PERMITS,
14, AFTER THE DEVELOPMENT OF ROADWAY AND UTILITY IMPROVEMENTS, THE APPLICANT SHALL INSTALL
PERMANENT FENCING (I.E. SPLIT -RAIL FENCE OR OTHER APPROVED BARRIER) AND SIGNAGE ALONG THE ENTIRE
• EDGE OF THE STEAM/CREEK BUFFER. THE SATISFACTION OF THIS REQUIREMENT SHALL BE SUBJECT TO THE
REVIEW AND APPROVAL OF THE DEVELOPMENT SERVICES DIVISION PRIOR TO RECORDING OF THE FINAL PLAT,
1. ROCKERIES 4' AND OVER IN HEIGHT REQUIRE
A BUILDING PERMIT.
2. ROCKERIES 4' AND OVER IN HEIGHT REQUIRE
ENGINEERING SUPERVISION BY SPECIAL
INSPECTOR (UBC 3068), WHICH AT MINIMUM
SHALL CONSIST OF INSPECTION AND WRITTEN
CERTIFICATION OF SUBGRADE, PLACEMENT OF
BASE COURSE AND DRAINAGE, AND FINISHED
ROCKERY.
3, ROCK SHALL BE SOUND AND HAVE MINIMUM
DENSITY OF 160 POUNDS PER CUBIC FOOT.
4. THE LONG DIMENSION OF ALL ROCKS SHALL
BE PLACED PERPENDICULAR TO THE WALL.
EACH ROCK SHOULD BEAR ON TWO ROCKS
IN THE TIER BELOW.
5, IMPROVED WALKING SURFACES ABOVE AND
ADJACENT TO ROCKERIES OVER 30" IN HEIGHT
SHALL BE PROTECTED BY A GUARDRAIL
CONFORMING TO UBC 1711.
6. ROCKERIES ARE EROSION -CONTROL STRUCTURES,
NOT RETAINING WALLS. NATIVE MATERIAL
MUST BE STABLE AND FREE-STANDING IN
CUT FACE.
7, ANY DEVIATION IN DESIGN OR IN PLACEMENT
OF ADJACENT STRUCTURES MUST BE SUBMITTED
WITH THE SEAL OF A CIVIL ENGINEER
CURRENTLY LICENSED IN THE STATE OF
WASHINGTON.
8, WALLS LESS THAN 4' IN HEIGHT MAY BE
CONSTRUCTED WITHOUT REINFRORCEMENT
GRID OR JUST ONE LAYER IN THE MIDDLE
AS APPROVED BY THE GEOTHECTIONICAL
ENGINEER,
NATIVE GROWTH
PROTECTION AREA
THIS UPLAND BUFFER
AND CRITICAL AREA IS
PROTECTED TO PROVIDE
WILDLIFE 11ABITAT AND
MAINTAIN WATER QUALITY
PLEASE DO NOT DISTURB
THIS VALUABLE RESOURCE
CONTACT CITY OF uiNTON
AT (425) 430.7200 WIT3i
QUESTIONS OR CONCHRNS
NOTES
1. NGPA SIGNS SHALL BE PLACE NO GREATER THAN 100 FEET
APART AROUND THE PERIMETER OF THE NATIVE GROWTH
PROTECTION AREA. MINIMUM PLACEMENT SHALL INCLUDE
ONE TYPE 1 SIGN PER WETLAND, AND AT LEAST ONE TYPE
1 SIGN SHALL BE PLACED IN ANY LOT THAT BORDERS THE
NATIVE GROWTH PROTECTION AREA, UNLESS OTHERWISE
APPROVED.
2. SIGN PLACEMENT SHALL BE SUBJECT TO THE APPROVAL OF
CITY OF REN TON. ALTERNATIVE SIGN DESIGNS MAY BE
SUBMITTED TO CITY OF RENTON FOR APPROVAL,
3. ALL SIGNS MUST BE SECURE AND PERMANENT.
NATIVE GROWTH - 12" x 18" ALUMINUM SIGN WITH
PROTECTION AREA WHITE REFLECTIVE BACKGROUND,
INSTALL ONE PER PROTECTED
FEATURE IN A CONSPICUOUS
PLACE
MINIMUM OF TWO GALVANIZED OR
5)5 STAINLESS STEEL WOOD LAG
BOLTS TO FIRMLY SECURE SIGN
4" x 4" PRESSURE TREATED
WOODEN POST WITH 112"
CHAMFER A T TOP
---*-MAGNETIC LOCATOR PIN (E.G.,
of
PIPE, REBAR, 20 PENNEY NAIL,
ETC.) PLACED 8-12" FROM POST
ALONG NGPA LINE
2'
fr ,
MIN.
QUICK-SET CONCRETE
COMPACTED NATIVE MATERIAL
6
TYPE 1 SIGN
pt')
AL it,,)
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date _
-Date-
Date - _
RECOMMENDED
FOR APPROVAL
tZ NA 1310�
EXPIRES: MAY 6, 2007
�Lo
CO 00
W0)
0
00
Q 0000
0000
C] r
zZN
r-WO
N�
J �W
Z ,, -, ,
0W0NNWQ
I. -NZ
W
u
WJ
V •�
�•�••� 1V
U
• r--I • �-rl
s.-�
vl
�
W
bA
•�
Z
0
Z
0
W
�
rn�
VJ
®
14
N
m
W010
11
DN
N
rn
V♦
L0
� �
X
Q
LL
O
Z
0
_j O1
D W
J a0 N
W �N
0
Q
a
ocn3N
�=LLJ,
J
WIr
CE J z
for:>F
mNQQ
_NWT
IL J0(n(L
PROJECT NO.: 02054
DRAWN BY: AA/JGC
ISSUE DATE: 03-07-05
SHEET REV.: 06-13-05
GRADING
DETAILS
AND NOTES
02054DT02-009B
ld
o �1
b
N C"
W
N
i l 22 SCANNED OCT 2 8 Z005 L`r�,. /I? -J'_2 (1_66d