Loading...
HomeMy WebLinkAboutWWP2703279.2�Lo c 1 N O o o o w E: a N U o cq Z z p 3 o o N w 0 � In O of o n z z N W o I J W Z 0 Ld ry IZ W � � 0 r1r) Q Q � z u) n Q a � m W a a _ W a J O 4- r In x a of � U w r Z3 n w �. 0) U o �E 0 a mE E N Q'N C M U N �0 Tn o� S o s c) �L4 x J J V Z p Za N ? yzo II 8 Z ��< - O Z A o o� a om v' 9 v' 69 a y>om T Z Y O m w Q w Q 0 x x m z O V) w ry W O z NOTE: INSTALL CATCH BASIN INSERTS AT THE FIRST SET OF CB'S TO THE WEST IN THE PAVED TRAVELED WAY. 12" CONC. PIPE \ INVERT-103.36 O SCALE 1 " = 209 20' 0 10' 20' 40' SSMH #2, 48" 0 w/SOLID LOCKING LID , STA: 6169-99, RT 5+Go. 3t, 4,3FT RT RIM t 1.22.1 (MATCH GRADE) 48+.66 STA: 2+09.35, 5.33 LT o IE = i4IQ 80 IN (E)(KNOCKOUT) 4-j¢,i>l TAX LO,T .NO. 142305-9003 N IE= 98.17 (� STUB) - IE _112.99 8" 0 OUT (W) CAP AND ADD 2"x4" (TO IE) TO INDICATE LOCATION OF SERVICES STA: 4+10.05 STA: 4+90.02 14LF2'00oCONC. ��jCy MAIN SIE= 106.21 (® MAIN) IE= 109.29 (@ MAIN) .. FOUND REBAR ITE TBM: DITCH FADES , WOCAP, LS #1766 NAIL IN PP - - - - - _ - S 2.53' N18°03'04"W EL=122.32 1+23.84 368 LF 8" 0 SS @-.r.$6% �+ • • SDR35 ASTM D3034 ON PROP. COR. • � � d .. • • .. .. 00 � 2„ CONC. PIPE RAW 4+00 ESP L - �. ------ ---.----- - _ 5+00 INVERT=120.21 - -- - 6+00 R W ----------.--- -- =-- =- -- - T----" --- ---'--------- - - --.005.25 _,- �- -.-. '" ---------------'- --- --- --'- SE--132N-D STREET M INTX STA 2+00.00, 0.00 RT, SE 32ND ST. - - - - - - - - -'- - - - = STA 10+00.00, 0.00 RT, 152ND AVE. SE -- -- _ _- - -__-- --- �{ w ------------- OVHD--------- - --�-- Cf-1 O -W- --- LLIWCL (�"-j S GAS GA1�S S G AS - - - - --R18�`fi0'�7"W(C� - - - - - 81CD-GWWP-1OVHD- - � f• R/W �GA� -mac CAUTION: PROCEED WITH CAUTION IN THE I �G� / CONC PIPE 10.00'(TYP) 5.00' (TYP) 80.00' 80.00S SE 132.ND STREET - PUBLIC SANITARY SEWER EXTENSION [+Z.�f� 7-o&uT A PORTION OF THE SE 1/4 OF THE NW 1/4 OF SEC. 14, TWP 23N., RGE. 5E., W.M. EX. SSMH #1, 48"0 �• C�1w/SOLID LOCKING LID , ► 47. CITY OF RENTON, KING COUNTY, WASHINGTON STA: �, > LT LF 8"0 SS RIM = -465.98 4-6&-O'l SDR35 ASTM D3034 IE = 9�.58 8"0 IN (SE) 459.4I' STA: �+96SAWCUT EXISTING ASPHALT AND IE = 9 EX. 8"0 OUT (W4-5�/. SSMH 1, .13, 5�§ RT w SOLID LOCKING LID � *,K REMOVE ASPHALT PAVEMENT CORE DRILL EXISTING SSMH 2a-oo.6?., (TYP) AND RECHANNEL SSMH RIM f 166.90 (MATCH GRADE) 469.1'7 IF NECESSARY IE = 98:19 8"0 IN (E,NE) 4,c,.ZI PER KING COUNTY ROAD STANDARDS (KCRS) CONSTRUCTION LIMITS (TYP) IE = 98..06 8"0 OUT (NW) 4,�,0.11 SECTION 8.03(2)c. (TYP) EXISTING ROW LINE 6+78.79 PROXIMITY OF THE EIXTSING WATERMAIN FITTINGS AND POSSIBLE I' 0 INVERT=10725 �j I -4+(2.07 31.51 - - - - Q R/W VERTICAL DATUM TRUST BLOCKS. / STA: -4+19�A9 RT - - - - - - FENCE COR. IS `9 l • •• I O SIDE SEWER STA: A , Elf � .. INAVD-88 f 12" CONC, PIPE 65 �Y 2.6'N & 1.0'E 32 ELF 6 0 I.Sl � I SIDE SEWER (NORTH AMERICAN VERTICAL DATUM OF 1988 IN VER T= 109. 01 IE- (� STUB) ' 0E PROP. COR. I I �,'15i39-LF 6„� C88 2.83% PER KING COUNTY DEPARTMENT OF PUBLIC • . _ I WORKS IE- 4-199.89 (@ STUB) FENCE lS 0.6'W I OF PROP. LINE I I (BENCHMARK o Q I y I THE ELEVATIONS AND CONTOURS SHOWN HEREON ARE BASED UPON A PROJECT SPECIFIC ASSUMED DATUM, AND ARE NOT RELATED TO ANY �J I w I I O yp PUBLISHED VERTICAL CONTROL NETWORK. o ! MIN. FF N MIN. FF NAIL SET AN ONSITE TEMPORARY BENCHMARK: ELEV=112.0 - ELEV=115.0 Li w T N \ IN W. SIDE OF PP NEAR NE PROP. CORNER. N ;n I I o I ; Lo ` ELEVATION = 122.32 z d FEET. 4- Ln� EQUATION FOR THE CITY OF RENTON DATUM IS 130 120 w F-:cn co o W 5- 32790�0 PLAN VIEW SCALE: 1' = 20' . j44wi- f 01 N - O g 130 cwn ,I � ft� F--7 O 0 O oo� 0 �o J o acn F- 00 d ------ o O EXISTING PROFILE OF THE NORTHERN ROW LINE J O Q J -- ¢ -- - 0 0 -- ._ __._ -- 120 00 - -- + O - F-�-- - -- - - -- - EXISTING WATER 360 LF 8"o SS @ 3.86% _ - - - - -- - - - - PVC SDR35 ASTM D3034 I� II 37LF8"0SS@1.14% 100 I I n - rrnnzr- ACTAA n-m-d 90 I SSMH #1, 48" 0 w/SOLID LOCKING LID STA: 2+00.13, 5.25 RT RIM f 106.90 (MATCH GRADE) IE = 98.10 8" 0 IN (E, NE) EX. SSMH 1, 48" 4 w SOLID LOCKING LID IE = 98.00 8" 0 OUT (NW) STA: 1 +62.71, 8.49 LT 80 RIM = 105.98 IE = 97.58 8"0 IN (SE) IE = 97.48 EX. 8" 0 OUT (W) O O 00 D �� O O cc 1+80 2+00 2+40 STA: 4+10.05, 35.00 RT SIDE SEWER 35 LF 6"0 2.00% EXISTING ELEVATION AT CL ^7 O C-` L CD I- 2+80 3+20 3+60 4+00 4+40 PROFILE VIEW SCALE: HORZ.: 1' = 20' VERT.: 1' = 10' I STA: 4+90.02, 35, SIDE SEWER 30 LF 6" 0 ®2.00% O 00 4+80 SSMH #2. 48" 0 w/SOLID LOCKING LID I STA: 5+60.09, 5.25 RT RIM t 122.17, MATCH GRADE IE = 112.10 8" 0 IN (E)(KNOCKOUT) IE = 112.00 8" 0 OUT (W) O O N 5+20 CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 O CV N N N N 5+60 100 90 :i CHECKED FOR COMPLIANCE TO CIT STANDARDS Date 10 z6 � t-2,246CA�U� Date Zp Date SCANNED OCT 2 7 2006 -ya s 3279o,a, �CANNFD OCT 2 8 2005 THE RIM OF THE EXISTING SSMH AT 152ND AVENUE SE & SE 132ND STREET ELEV=458.72 EQUALS 105.98 (CRONES RELATIVE DATUM) CONTOUR INTERVAL: 2 FEET. LEGEND FOUND MONUMENT, AS SHOWN FOUND REBAR/PIPE, AS SHOWN SET 518 " REBAR & CAP, LS 1129537 (P1) INDICATES CEDARECREST ESTA VALUE PLAT OF j (P2) INDICATES WILLOWBROOKORD OF VALUE LANE (17011-)R PLAT OF (C) INDICATES CALCULATED VALUE PER FIELD MEAS. AND ROTATION (M) INDICATES MEASURED VALUE R/W RIGHT OF WAY E/P EDGE OF PAVEMENT FENCEL INE �D FIRE HYDRANT �-� POWER LIGHT POLE -0 POWER POLE m POWER JUNCTION BOX SO EX. SANITARY SEWER MANHOLE o TELEPHONE RISER wm ❑ WATER METER wv N WATER VALVE fkA!j SCHWEHM & AssocrAmPric CIVIL ENGINEERING & PROJECT MANAGEMENT 1945 SOUTH 375TH STREET Bus: (253) 815-1700 FEDERAL WAY, WA 98003 For (253) 815-1701 bschweikl@comccst.net