Loading...
HomeMy WebLinkAboutWWP2703279.4V I O N \ O x V I N z U-)U z C) o � o �U K 0 N 0 n z Z N Uj W I— o �X W W Cf) — Z Ld Q 0 W �w 0 oU) o CV ry Q Q C� W Z Ln Cn< O i z U_ a a m N W a a � n I Z HZZ O z V)io Cn Eau a O E~O zU Q N m m o� om om z U, 2 Y w 8 Vi a Ct Q LU Q 0 z 0 U) w Iv M Z U_ 1 —1, 3/4" SQUARES SPACED — 3/4" AS INDICATED — HT. 1 /8" RAISE-1/2" WIDE BORDER /8" 2-7 8„ SE 132ND STREET PUBLIC SANITARY SEWER EXTENSION A PORTION OF THE SE 1/4 OF THE NW 1/4 OF SEC. 14, TWP 23N., RGE, 5E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON 12"Q FIBER PACKI I 45` (1 /8) PIPE MATERIAL AS SPECIFIED BY THE ENGINEER CONCRETE CLASS 3000 3/4„ 15„ II I PLUG TO BE SEALED CAST IRON RING AND COVER • IN SAME MANNER AS II I MAIN SEWER JOINTS. NOTE: IN UNIMPROVED AREAS POUR 1'-0" THICK 6 INCH OR 8 INCH CLEAN —OUT 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND Y RING AND COVER. o ADOPTED IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING ��� CITY OF RENTON AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. p=` STANDARD PLANS LST DATE: 12/96 10/17/961 Added notes.I DCV AG DATE REVISION BY APPR'D DWG. NAME: BW18B SP PAGE: B076 4" CLEANOUT WYE WITH 45' BEND AND PLUG. W W z I zl J J w w w � �I a HOUSE HOUSE 31-0" MIN. ALL 90' TURNS SHALL BE ACCOMPLISHED BY MEANS OF A WYE AND 45' BEND. 1 TWO 45' BENDS SHALL NOT BE ACCEPTABLE. w O BEND AS REQUIRIED 4" SEWER PIPE LNO MORE THAN 45' BEND). 4" SURFACE I (TYPICAL)ERY 2ND CHANGE IN DIRECTION OR GRADE WILLtK EE4NOUT 4" SEWER PIPE, SEE NOTES 2 AND 3. REQUIRE A SURFACE 4" TEST TEE WITH MINIMUM LINE SIZE FOR OTHER THAN 1 CLEANOUT WYE. --�� 4" CLEANOUT PLUG FACE UP (TYPICAL) SINGLE FAMILY 1 S 6" 1 PROPERTY LINE — WYE WITH PLUG PROPERTY LINE - to �L 6' MIN. 6"x 4" REDUCER Z z z ~ (TYPICAL) Z MAIN SEWER LINE TYPICAL BUILDING SEWER INSTALLATION PLAN z - 4" SOIL PIPE Q o 4" CALDER COUPLING z IF THE BUILDING SEWER SERVES ANY FIXTURE o ih nl x OR EQUAL TO FIT Q m HAVING FLOOD LEVEL RIMS LOCATED BELOW THE I o ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER in o ~ SURFACE CLEANOUT - OF THE PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION j 4"x 4"x4" WYE of o DEVICE SHALL BE INSTALLED EQUAL TO TYPER 2-84. m iO � 4" PIPING b 4"x 4"x 4" TEST TEE 0 4" CALDER COUPLING I w FACE UP AND PLUGGED z OR EQUAL TO FIT w W 4" NIPPLE D (n SURFACE CLEANOUT zX I'I 6"x 4" REDUCER m 4"x 4"x4" WYE J = V 6" COUPLING TO FIT ~ z END 6" PIPE a o 0 I I z REMOVE 2"x4" STUD AND CAP OR PLUG o � m ON END OR EXISTING 6" SEWER PIPE. 0j AND INSTALL BUILDING SEWER COUPLINGS, I I co REDUCER, TEES, AND BENDS AS REQUIRED. PROPERTY-7 LINE} z I 1--- SEE SIDE SEWER DETAIL o 6" PIPING TO 6'-0" w N BEYOND PROPERTY LINE z I I 6" SIDE OUTLET TEE M 0- SEE NOTE 6 SEWER MAIN I ( of PLAN BUILDING SEWER INSTALLATION 4" PIPING PLAN BUILDING DRAIN FOR LOW HOUSE CALL FOR LOCATIONS BEFORE YOU DIG 48HR LOCATORS 1-800-424-5555 NOTES: 1. Prior to installation of a sanitary sewer connection, a side —sewer permit must be purchased from the City of Renton Public Works Department. 2. Types of pipe and fittings that can be used for sanitary sewers shall be approved by the Department of Public Works. Rubber or neoprene gaskets as specified by the manufacturer, shall be used on joints. 3. A minimum grade of 2% (1/4" per foot) must be maintained with 4" pipe. In the event a 2% grade cannot be maintained. The owner must grant a rde release to the City and then can install pipe at a grade of 1 %. 4. For inspection of side sewer, call 24 hours in advance, 277-5570. Site must be ready for inspection and representative on site when inspector arrives at appointed time. Side sewer and stub shall be tested per City specifications. Make the connection at the house. Do not backfill the ditch until approval is given by the inspector. Final approval will be granted after the existing septic tank has been pumped out and filled with sand. 5. Install side sewer with 2' minimum cover. 18" cover is allowed at the house if outlet is shallow. 6. If side sewer stub is not available. The owner shall be responsible for its installation. The side sewer shall be a minimum of 6" in size. If tee is not available, the main sewer line must be tapped thru a cast iron saddle. All work within street right—of—way shall be done by a licensed and bonded contractor. 7. All work shall be accomplished in accordance with the Washington Industrial Safety and Health Act. (WISHA) 8. All trench restoration for side sewers in the public right—of—way shall conform to the most current trench restoration requirements as shown on dwg. #HR-23. 9. All building sewer and side sewers shall have bedding in accordance with drawing BW18C or BR09 as applicable. 10. There shall be a minimum 10 foot horizontal seperation between sanitary side sewers and water services and a minimum 5 foot horizontal seperation between sanitary side sewers and all other utilities. — TYPICAL BUILDING SEWER — SIDE SEWER (PROPERTY LINE) TO BUILDING CONNECTION INSTALLATION PLAN Y p ADOPTED CITY OF RENTON p STANDARD PLANS F NA LST DATE: 12/96 DWG. NAME: BR35 SP PAGE: B082 --1 /2'' WEB 8 PL. FRAME (NON —LOCKING A TYP. /2" x 3" x 3/8" NON—SKID PATTERN ST INTEGRAL ON TOP COVER (NON —LOCKING FOR 5/8"-1 1 N.C. x 1-1/4" S.S. SOC. HD. CAP SCREW (3 REQ'D.) E / -,--TYP. NON—SKID PATTERN 1 " SEAT 2" RAISED LETTERS AS REQ'D. SEE NOTE No.3 BELOW UNDERSIDE SHOWN FOR CLARITY 3/4" CORE (TYP.) ON 23" B.C. VI\ILL rivv I -AP 5/8"-11 N.C. 1-1/2" CORE (TYP.) (LOCKING) ON 23" B.C.(TYP. 3 PL.) FRAME (LOCKING) COVER (LOCKING) NOTES: 1. FOR NON —LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. 2. FOR LOCKING LID USE OLYMPIC FOUNDRY No. MH 30 D/T OR EQUAL. 3. USE FRAME AND COVER FOR STORM (SPECIFY ''DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). 10/17/9 Edited notes. DATE REVISION 33-1/4" SECTION A —A 5/8" 3/8" 1_3/8„ 2" TI I i—i- —I �_2-1 /2„ 25' SECTION B—B MANHOLE FRAME AND COVER Y ADOPTED CITY OF RENTON STANDARD PLANS �F NA LST DATE: 12/96 DCV AG BY APPR'D DWG. NAME: BR29 SP PAGE: B074 5-32T9og A S BUILTS CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 SCANNED CHECKED FOR COMPLIANCE TO CITY STANDARDS D a to 10 26-C Date Date 2 7 2006 VERTICAL DATUM NAVD-88 NORTH AMERICAN VERTICAL DATUM OF 1988 PER KING COUNTY DEPARTMENT OF PUBLIC WORKS BENCHMARK THE ELEVATIONS AND CONTOURS SHOWN HEREON ARE BASED UPON A PROJECT SPECIFIC ASSUMED DATUM, AND ARE NOT RELATED TO ANY PUBLISHED VERTICAL CONTROL NETWORK. SET AN ONSITE TEMPORARY BENCHMARK: NAIL IN W. SIDE OF PP NEAR NE PROP. CORNER. ELEVATION = 122.32 FEET. EQUATION FOR THE CITY OF RENTON DATUM IS THE RIM OF THE EXISTING SSMH AT 152ND AVENUE SE & SE 132ND STREET ELEV=458.72 EQUALS 105.98 (CRONES RELATIVE DATUM) CONTOUR INTERVAL: 2 FEET. �F wASA.� N&,� ��1 j 22�IONAL !�P- o� 0' EXPIRES 09/20/06 •� SCHWEHCL & Assomns, PLrc CIVIL ENGINEERING & PROJECT MANAGEMENT 1945 SOUTH 375TH STREET Bus: (253) 815-1700 FEDERAL WAY, WA 98003 Fax: (253) 815-1701 bschweikl@comcGst.net EMEMEMEN cCANNFD DCT 2 8 2005