HomeMy WebLinkAboutWWP2703294.1SW1/4 NE1/4 SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
i
:
855 GRAHAM AVE NE
E r f
IE=470.31 IE=469.95 IE=469.25 IE=469.20 � I
6 SS 6 SS 6 SS 6 SS
S=2.00% S=2.00% S=2.00% % S=2.00%
_ BEGIN PROJECT _ _..o _ _ u.. _ _ ___ �__ _ _ _ -.w
�FE.477-
ac-
6 `1
>..
416 -
CSC HA, T i
MH 2
ao
ao
+
_
+
04
+1
cv
259 LESS 8" PVC S=0.005oSET/Ft
8" PVC
SS
SS SS
__ f
20 0 20 40
1 "= 20 ITS I
Scale Feet
7.9 5?
GRAHAM AVE NE ��� ASS iA i� �- �
r AH 1 EDGE ASP�fALT
ao
-�
•
4,
1Lo
END.. PROJECTucx
_ r�- ."
F o CONNECT TO EX.
N, o SANITARY SEWER
17
Ilk
LOCATIONS SHOWN FOR UTILITIES ARE APPROXIMATE. H
PRIOR TO STARTING CONSTRUCTION `W H A
CONTACT ONE CALL (1- 800-424-5555) FOR UTILITY LOCATIONS i,
BENCHMARK BASIS OF BEARINGS C20 coo $,r.,Q,E o�. _
CITY OF RENTON NO. REN1907 CITY OF RENTON - NAD83 (1991) �Ie-9114 AYE N3
FOUND CHISELED SQUARE IN THE SOUTHEAST jRZryC,)A R G-SToe^"MO� liy,
CORNER OF THE CONCRETE FOOTING FOR
MAILBOXES ON THE WEST SIDE OF HOGUTAM PER 0- 1" or ���^� W o2a.Z.lC
AVENUE N.E. - ADJACENT TO HOUSE NO. 12014 VERTICAL' DATUM Z
ELE. 472.676- U.S. FEET - NAD83(1991) CITY OF RENTON - NAVD (1988) STD DA RDS
470
...---'.......:....................................... ............................ ...
8"-..PVC:....-,.-n.onrn..cT../L-r----- .;....... ......... ..:............... ...;_...:.........._..;------....----..:....................._.._..._..._..;........
...........................................:............ a+oo......---.............................................:.... 1 �flQ..............._....................................................................._... 200................_.......
I No. I Date I By I Ckd.
Revision
:.. . .............3--+00 ...............
VS R. N. PARNELL COMPANY
Drawn pprved- y��.
y CIVIL ENGINIMIldG ENGINEERING MANAGEMENT
Mai
4422187th Place S.E.
Checkedy: Issaquah, WA 98027
RNP Scale: 20� Phone: (425) 643-3560 Fax: (425) 641-5095
EX ...S.M H ...................480...... .
RIM=475.90
IE=467.90
IE=467.80 �NEW):
EX.)
5 0 5 10
1 "= 5'
vertical scale feet
20 0 20 40
1 "=20'
horizontal scale feet
BRETT HOLMES
32104 2ND AVE SW
FEDERAL WAY, WA 98023
(425) 254-0049
(206) 375-1345
SEWER GENERAL NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS
OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 A.M. TO 3:30
P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AT 235-2620. ALL,STREET CLOSURES,
PARTIAL OR FULL, SHALL BE APPROVED BY THE PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK 1N THE RIGHT OF WAY.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL
PUBLIC WORKS CONSTRUCTION" PREPARED Y WASHINGTON STATE CHAPTER AMERICAN PUBLIC
WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS,
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. AND IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID
DAMAGE OR DISTURBANCE.
5. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO
STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR' RESPONSIBILITY TO SECURE
ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. INSPECTION WILL BE
ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE
BACKFILLING ALL CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AN6 OTHERS ON THE CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY
OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED � BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON 'THE JOB SITE WHENEVER CONSTRUCTION IS
IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE
SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED
PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE
AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES THOROUGHLY TAMPING EACH
LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR
ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH
MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED,
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL
BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE
EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY
MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT
HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON
CURRENT STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G.S.
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE
SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE
COMPLETION OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHA BE LAID ON A PROPERLY PREPARED FOUNDATION IN
ACCORDANCE WITH SECTION 7-02.3 1�j OF THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATIONS FOR ROAD AND BRI I E CONSTRUCTION. THIS SHALL INCLUDE NECESSARY
LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS
PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT
THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING
BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034,
SDR 35, OR DUCTILE IRON CLASS 50.
17. IN UNIMPROVED AREAS MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18 INCH ABOVE
FINISHED GRADE. IN kVE-D_ AREA COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
6" MANHOLE FRAME AND COVER
SEE DRAWING BR29
NOTES:
12" MrX24"
ADJUSTMENT (4- MIN.)
1, STEPS TO BE 3/4' 0 DEFORMED BAP GALVANIZED SAFETY
STEPS OR EQUAL
ONE
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
LIBBER GASKETED JOINTS
3. CASTING TO BE PER DRAWING BR29IN
ACCORDANCE WTH ASTM C-443
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
_CONCRETE.
5. ALL JOINTS SHALL BE GROUTED.
STEPS - 3/4' DEFORMED BAR
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
STEPS SHALL BE INCLUDED
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
"
WITH A HIGH SOLIDS URETHANE COATING;
ONCRETE RISER BY PIPE INC.,
WASSER MC-CONSEAL OR APPROVED EQUAL;
7' MIN•
OR APPROVED EQUAL
Cacti OF COATING SHALL BE WHITE.
7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C-443.
8, CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
AX. PIPE SIZE - 'E'
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
72. (tm)
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL
R-STD. ALUMINUM
�/�RLVANIZED
STEEL
MORTARETE
FILLET
SHELF
'A'
'B'
'C'
'D'
'E'
48' MH
48
6' MIN.
5'MIN
24" MIN.
21" I.O.
1�
BASE SECTION
54' MH
54"
8" MIN.
5.5 MIN.
24 MIN.
24" I.D.
�.rRECAST
R CAST IN SHELF.
60' MH
60-
8' MIN.
6- MIN.
42 MIN._1
30' I.D. i
r
SANITARY MANHOLE: TYPICAL DETAIL
6- MIN. (TYP)
ADOPTED
CrT OF BEHIM
SANITARY MANHOLE TYPICAL DETAIL
S*•NDAM a1.1e
s ac.am m 07" 48. W . ear WARM ES I f..s I- ia' DAM +z/96
NOT TO SCALE
+9
m,en ,W
6cv
rc
s
. + L. WT M f
SLY
A9
DATE
I REVISION
113Y
DWG. NAME: BR28 SP PAGE: 8071
o� SANITARY
MANHOLE
TYPICAL DETAIL
24'
24'x 6" FRAME AND UP
PER DRAWING BR29.
4' MIN. TO
12" MAX.
m
in
0
12"
iv
-
w
m
a
a
4"
Ix' S4"
a
`' -
`.
*':
a
r.
`v
m
0
3
a
NOTES:
1. STEPS TO BE 3/4. 0 DEFORMED BAR GALVANIZED SAFETY
STEPS OR EQUAL
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. OPENING SHOULD BE ON DOWNSTREAM SIDE.
6. ALL JOINTS SHALL BE GROUTED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING:
WASSER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL
S- SANITARY SAAUDW MANHOLE TYPE B
ADOPTED
aTr a earou
.�+
arum.® awe
1ST UM 12/96
10 7 as" NOTES WV.9
s r�+,m fiolcs Ery DWG. NAME: BR37 SP PAGE: 8072
OA
SANITARY SEWER MANHOLE
TYPE B SHALLOW
HOLMES SANITARY SEWER EXTENSION
SEWER PLAN & PROFILE
855 GRAHAM AVE NE
RENTON, WA 98059
TAX LOT NUMBER: 4279200130 Sheet 1 Of 1
SCANNED MAY 112006