PORTION OF THE S.E. 1147 S.E. 1147 SEOTION 4, TOWNSHIP 23 NORTH, RANGE 5 EAST, -W.M.
SANITARY SEWER NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF thick 2*-4' squov
RENTON UTILITY DEPARTMENT AND TT-IE LATEST EDITION OF THE WSDOT/APWA STANDARDS ANO SPECIFICATIONS. A, rhg cwtd cow.
2. THE HOURS OF WORK 1N THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 A.M. TO 3:30 PM ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT (425) 430-7200. ALL
STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS 1N
ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
m
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS
CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION (APWA),
LATEST EDITION AND CITY OF RENTON STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE.
5. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO
STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.)
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF
BACKFILLING ALL CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE
SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS
PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER
PLANS.
V. A COPY OF THESE APPROVED PLANS MUST BE ON 7NE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS W1TH A LOOSE AVERAGE DEPTH OF 6
INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 959 OF MAXIMUM DENSITY. THESE
COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE
TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH
CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH
SAW IN A CON77N000S LINE. A TEMPORARY COLD MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND
COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF
CURRENT CITY OF RENTON STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, NAVE) 1988 (METERS) AND NAD 198311991 (METERS).
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE
DEPARTMENT FOR THE PREVEN77ON OF ON -SITE EROSION AFTER THE COMPLE77ON OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM
GRADE SO THAT THE EN77RE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE.
PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER "GASKETED ASTM 0 3034, SDR 35, SDR, C900
OR DUCTILE IRON CLASS 50.` SANITARY SEWER FORCE MAIN TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING
TO LATEST REVISIONS OF AWWA C110 & C111, THICKNESS CL.52.
17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN
PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. ALL MANHOLES SHALL HAVE LOCKING
LIDS.
18. ALL SANITARY SEWER IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THESE APPROVED PLANS. ANY
DEWA77ON FROM THESE PLANS WILL REQUIRE APPROVAL FROM THE OWNER, ENGINEER AND APPROPRIATE PUBLIC
AGENCIES.
19. LOCATIONS OF ROADWAYS, BUILDINGS AND PARKING AREAS SHOWN HEREON ARE APPROXIMATE. FOR DIMENSIONED
LOCATIONS OF THESE IMPROVEMENTS, REFER TO THE ARCHITECTURAL SITE PLAN. IMPROVEMENT AND STRUCTURE
LOCATIONS SHALL BE FIELD SET BY THE ENGINEER AS REQUIRED.
20. ALL MANHOLES SHALL BE PER THE CITY OF RENTON STANDARDS AND SPECIFICATIONS. ALL MANHOLES SHALL HAVE A
MINIMUM 0.10-FOOT TO MAXIMUM 1.0-FOOT DROP BETWEEN INVERT IN AND INVERT OUT. ALL MANHOLE COVERS
SHALL BE ADJUSTED TO FINISH GRADE PRIOR TO FINAL PAVING AND LANDSCAPING.
T AT AST 959' OF THE MAXIMUM DRY DENSITY PER
MORTAR FILLET
NOTES
1. A/ dgldrb a1raM to M►taM Foundry Co. hrt Na 247.
a In owhdt roo&a^ 1. !" around d onoot rhq ow oow
nputrd by of *W *-ft SIM
r-o-
coNcnETE ;t ' .��t;
12'4
1� .AOINT
PACIO
15- i� PAC1fMC
SECTION A -A
43• (1/b) we
B B
PIPE MATERIAL AS
SPECRED 9Y THE .`
ENGMER
SECTION 8-8
CAST IRON RUNG ANQ OOVER
. %' PLUG iO 9E SEALED
IN SAME MANNER AS
-MAIN SEM JOINTS
ADOPTED
Standard plena
ISr DAIS: 04/2003
6 INCH OR 8 INCH CLEANO UT
DWG. NAME: 8W188
SP PAGE : 6076 -
MANHOLE FRAME AND COVER SEE
DRAWING BR29 (SP PAGE B074)
ADJUSTMENT (4" MIN.)
CONE
'A'
'B'
.C,
.D.
.E.
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21" I.D.
54" MH
54"
8" MIN.
5.5" MIN.
24" MIN.
24" I.D.
60" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
NOTES:
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443 1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL.
Z STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
STEPS - 3/4" DEFORMED BAR
STEPS SHALL BE INCLUDED 3. CASTING TO BE PER DRAWING BR29.
CONCRETE RISER BY PIPE INC., 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE ,
OR APPROVED EQUAL
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING
CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING;
WASSER MC-CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE
MAX. PIPE SIZE - 'E'
LADDER -STD. ALUMINUM Z RUBBER GASKETED JOINTS SHALL BE 1N CONFORMANCE WITH ASTM C-443.
OR GALVANIZED STEEL 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 314 THE INSIDE DIAMETER OF THE LARGEST PIPE.
CONCRETE SHELF 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL
PRECAST BASE SECTION 10.MANHOLES EQUAL TO AND GREATER THAN 20 FEET DEEP SHALL HAVE A "SURETRACK"
OR CAST IN SHELF. CLIMBING AND FALL PROTECTION SYSTEM INSTALLED.
ADOPTED
CITY OF RENTON
1 Standard plans
SANITARY MANHOLE TYPICAL DETAIL LST DOTE: 04/03
NOT TO SCALE SANI TAR Y MANHOLE TYPICAL DETAIL
60" ALLOWABLE MAX.
2i. ALL TRENCH BACKFILL SHALL BE COMPACTED 0 LE FOR CAST IRON PIPE
/h OR DUCTILE IRON PIPE. / Gv�
ASTM D-1557-70 (MODIFIED PROCTOR), FOR THE FIRST THREE FEET ABOVE THE PIPE. THE REMAINING BACKFILL 1:3:5 W
tk
MAY BE TO 9090 IF NOT IN AN AREA OF FUTURE PAVEMENT OR STRUCTURAL FILL. TRENCH BACKFILL AND CONCRG
COMPACTION SHALL BE COMPLETED PRIOR TO TESTING LINES FOR LEAKAGE.BLOCKIAN�MP GR22. ALL SIDE SEWERS SHALL BE A MINIMUM 6" DIAMETER AND HAVE A MINIMUM SLOPE OF 2.0% PROPERTY / LOT 290 MIN SLOPE
CORNERS AND / OR BUILDING LOCATIONS AND FINISH GRADES SHALL BE ESTABLISHED IN THE FIELD PRIOR TO ANY - ( - - - - - - -SEWER CONSTRUCTION. SIDE SEWER TEE STA77ONS ARE REFERENCED FROM THE NEAREST DOWNSTREAM MANHOLE. THE HORIZONTAL
CONTRACTOR SHALL MAINTAIN ACCURATE AS -BUILT RECORDS OF ALL SIDE SEWER LOCATIONS. ALL SIDE SEWERS SIDE OUTLET TEESHALL BE TESTED AT THE TIME OF MAIN LINE TESTING. PIPE MATERIAL SHALL BE C900 FOR DEPTHS OVER 15'. MAIN SEWER MAIN
6" MIN.
23. WHERE A WATER MAIN CROSSES ABOVE THE SANITARY SEWER, AND LESS THAN 3'0 OF VERTICAL CLEARANCE EXISTS CONCRETE BLOCKING ANQLE
BETWEEN THE TOP OF SEWER AND BOTTOM OF WATER MAIN, THE SEWER SHALL BE CONSTRUCTED OR OF TYPICAL SIDE SEWER ELEVATION
RECONSTRUCTED WITH DUCTILE IRON PIPE (CLASS 50) FOR A MINIMUM HORIZONTAL DISTANCE OF 10' ON EACH SIDE TEE AT MAIN OVER 25
OF THE WATER MAIN CROSSING. ELEVATION
24.
SANITARY SEWER MAIN LINES (8" DIAMETER AND LARGER) SHALL NOT BE CONSTRUCTED ANY CLOSER THAN 10 FEET
NOTE. -
TO ANY BUILDING OR 5 FEET TO ANY CARPORT.
UNLESS OTHERWISE SHOWN ON PLAN,
SIDE SEWER SHALL HAVE A MINIMUM
25.
NEW CONNECTIONS TO EXISTING FACILITIES SHALL BE SEALED OFF UN77L UPSTREAM CONSTRUCTION IS FINISHED,
2.5' COVER AT PROPERTY LINE OR
3-5' LOWER THAN THE LOWEST HOUSE
TESTED, CLEANED AND ACCEPTED. ALL CONSTRUCTION DEBRIS AND WATER SHALL BE REMOVED PRIOR TO OPENING
ELEVATION, WHICHEVER IS LOWER.
THE SEAL. ALL TESTING SHALL BE IN THE PRESENCE OF A CITY OF RENTON INSPECTOR.
26.
PRIOR TO ACCEPTANCE OF CONSTRUCTION AND / OR ISSUANCE OF OCCUPANCY PERMITS, ENGINEER / SURVEYOR -
CERTIFIED AS -BUILT DRAWINGS MUST BE PREPARED OF ALL SANITARY SEWER FACILITIES.
ADOPTED
CITY OF RENTON
27.
INSTALL FALL RESTRAINT SYSTEM IN ALL SANITARY SEWER MANHOLES OVER 20-FEET DEEP. FALL RESTRAINT
SYSTEM SHALL BE "SURETRACT CLIMBING AND FALL PROTECTION SYSTEM", AS MANUFACTURED BY "MILLER FALL
standard plans
LST DATE: 12/96
PROTECTION".
STANDARD SIDE SEWER INSTALLATION
SEWER MAIN TO
PROPERTY LINE)
DWG. NAME : BR39 SP PAGE : 8078
111111mi-E
DWG. NAME : BR28
IPROPERTY LINE
r--- --
.. I 6'-O"
b FUTURE
6 BUILDING SEWER PIPE ;� BUILDING SEWER
zl
TEE WITH 6" SIDE OUTLET
W
0
0:
a.
UNLESS OTHERWISE APPROVED BY THE CITY, 2"x 4" STUD SERVICE MARKER PA\1100C.0
MAKE TAP THROUGH CAST IRON SADDLE SECURED PORTION WHITE' ANS STENCIL ON SIDE
TO SEWER MAIN WITH STAINLESS STEEL BANDS WORDING "SEWER" WITH 3" HIGH BLACK LETTERS.
WHEN CONNECTING NEW SIDE SEWERS TO EXISTING AND #6 WIRE WRAPPED AROUND THE STUD AND
MAIN. EXTENDED TO THE TOP OF THE STUD.
VITRIFIED CLAY, PLAIN AND REINFORCED SIDE SEINER DETAIL
CONCRETE, 01 PIPE AND Cl PIPE .SEWER MAINS S'3372050
ARE TO BE CORE DRILLED
CHECKED FOR COMPLIANCE RECOMMENDED
TO CITY STANDARDS FOR APPROVAL
0 S 33721 Date BY:
Date BY:
r 00
VJ 00
uj OD
> 0 00
coo 0
a:W 00WU
to-W co�z
rZ,--, '-s W
�tWoo<ow.<
�cn�NILN10-
bJJ
u
• PON(
C)
• u
WQbb
W •�
U a,
Z
0
00
�
I_
i
00
00
IL
z Q
Z
0)(WNCND
co
�0>�
W0
IQ<OD
0
cq
5 w
W
Wr_jFo<0
LL U(O0)a.
PROJECT NO.: 12007
DRAWN BY: VK
ISSUE DATE: 12/05/06
SHEET REV.: 07/19/2012
SANITARY
SEWER DETAILS
AND NOTES
06085DT04-C20.DWG
C20
SHEET 21 OF 29