Loading...
HomeMy WebLinkAboutWWP2703392.4LO �6" MIN. o Y + 6" MIN. TYPICAL --2" MIN. o MANHOLE ` F 6" MIN. ONE LENGTH OF DUC77LE IRON L) n I `` PIPE CLASS 50) TO SOLID 1/2 PLUG AS DAM BEARING WHEN SPAN IS MORE THAN 4'. FLEX/BLE JOINT BACKFILL WITH ' COMPACTED MATERIAL o I ` AS DIRECTED BY m 6" MIN. ENGINEER. o LLJ N O I CEMENT CONCRETE CLASS C POURED /N PLACE 90' BEND TYTON U-651 z TYP/CAL MANHOLE �- FOUNDAT70N En CONS EnS CONCRETE ENCA ED DROP CONNEC TI N 61 NOT TO SCALE �i a Cn cr 3 4" SQ1, CED - 3/4" a AS INDICATED _ HT. 1/8" a - E-E c4I-w _1n 7 A E� F-I a p' z w z a 0 a � r z ♦ G� 0 w x x w J L- C � U a w Q r M ❑ o 11/2" ❑000 I� ❑�❑ 1' SSE -1 2" 1 •• ' )E BORDER f 1„ 12"01� 10" FIBER JOINT 9 PACKING 8-3 4" 5/8" 1-1/r1111„ •, 45- (1/8) BEND �4„ 2' 2-7/8 ell 15" CAST IRON RING AND COVER T CLASS e 4-3/4" „ PLUG TO BE SEALED IN SAME MANNER AS MAIN SEWER JOINTS. SANITARY SEWER CLEANOUT DETAIL NOT TO SCALE CONCRETE CLASS C (SEE NOTE 8) FOUNDA T70N LEVEL- BACKFILL FOR RIGID PIPE (SEE NOTE 6) FOUNDA77ON LEVEL CITY OF RENTON DWG. NAME: BW78B SP PAGE. • B076 W (SEE NOTE 4) •.-a..ov-.. avo.-o•-avv.-.-.-.-.-.-. ......................... ......................... ......................... ......................... ......................... .❖.•o.❖.•.00.❖.❖.❖.❖.❖.❖..❖ ❖..❖.•..❖.•.o•..s;.❖O. .❖.❖oa ....... ........ •o..❖.❖.• ..❖..•..•. ........ ....... • r ......................... ......................... ......................... ........................ ...................... .............. .. .............. .. .......... .. ......... .. ......... .. 6" 12" MAX. 4" MIN. 7' MIN. SE 1/4, SE 1/4, SECTION 10, TOWNSHIP 23N., RANGE 5E., W.M. OR EQUAL. PT.#714 SEE DETAIL 5.1.4. 25" ,__,1_ADJUS7MENT (4" MIN.) =[tCONE 21" MORTAR JOINTS /a" 6-1/2L--1 48" CONCRETE RISER BY PIPE INC. OR APPROVED EQUAL. 12" (TYP) ° MAX. PIPE SIZE - 21 " I.D. ° LADDER -STD. ALUMINUM OR GALVANIZED STEEL MORTAR a FILLET Da CONCRETE SHELF PRECAST BASE SECT70N OR CAST IN SHELF. v ,,, 6" MIN. 6" MIN. NOTE.• SANI TAR Y SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WI77-1 A HIGH SOLIDS URE774ANE COA77NG; WASSER MC-CONSEAL OR APPROVED EQUAL; COLOR OF COA77NG SHALL BE WHITE. SA CIA TA R Y MANHOLE TYPICAL DETAIL N07 CITY OF RENTON DWG. NAME. BR28 SP PAGE. • B071 W SEA VOTE 4 LIMITS OF PIPE ZONE 1' 8 91 , (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE 1. PROVDE UNIFORM SUPPORT UNDER BARREL. TA 2. HAND TAMP UNDER HAUNCHES. B 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONL Y. (CLASS B, C. D. DES/GNJ 4. SEE 'EXCAVATION AND PREPARAT70N OF 7RENCH" IN THE SANITARY SEWERS SECTION BEDDING FOR RIGID PIPE OF THE STANDARD SPECIFICTAT70NS FOR TRENCH WID77-1 "W" AND TRENCHING OPTIONS. BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1/4 I.D. 12" MAX. • • ZERO • B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. i/2 O.D. 1/8 O.D. O.D. - Z I * A = 4" MIN. 27" I.D. AND UNDER O 6" MIN. OVER 27" I.D. THE PIPE ZONE WMLL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1-1/2 I.D. + 18". 5. 7RENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER TRENCHES" IN THE SANITARY SEWERS SECT70N OF 77-IE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED /N 774E BACKFILL MA TER/AL. 6. SEE `BEDDING MATERIAL FOR RIGID PIPE" 1N THE AGGREGATES SECT70N OF THE STANDARD SPECIFICAT70NS FOR THE MATERIAL SPECIFICATIONS 7. SEE 'BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECT70N OF STANDARD SPECIFICA77ON FOR THE MATERIAL SPECIFICATIONS. 8. PIPE MUST BE ANCHORED /N SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. V w PIPE BEDDING FOR SANITARY SEWERS ry O Z NOT TO SCALE CITY OF RENTON DWG. NAME: 6W18C SP PA GE. 8077 3' MIN. FUTURE 6" BUILDING SEWER PIPE - I _ BUILDING SEWER Z TEE WITH 6" SIDE OUTLET ,, 2"x 4" STUD SERVICE MARKER PAINT UPPER PORTION WH17E W ANS STENCIL ON SIDE WORDING o SEWER" Wl7H 3" HIGH BLACK LETTERS AND #6 WIRE WRAPPED 6" S/DE SEWER AND BUILDING SEWER AROUND THE S7i AND EXTENDED TO 774TE TOP OF HE STUD. PROPERTY LINE 6' UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WTH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXIS77NG MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1 PIPE SEWER MAINS ARE TO BE CORE DRILLED 60" ALLOWABLE MAX. vT UNLESS OTHERWISE SHOWN ON PLAN, SIDE k� FOR CAST IRON PIPE THE G SEWER SHALL HAVE A MINIMUM 2.5' COVER 1:3:5 MIX V� �N _ CONCRETE �,P� 25 OR DUCTILE IRON PIPE. G� ��OGK THE PROPER OWEST HOUSE ELEVATIrON, WHICHEVER /M'N MGa GR2% MIN SLOPE IS LOWER. 6" SIDE OUTLET TEE s HORIZONTAL , + _ + 6" MIN. SEWER MAIN SEWER MAIN CONCRETE BLOCKING ANGLE TYPICAL SIDE SEWER ELEVATION OF TEE AT MAIN OVER 25 ELEVATION STANDARD SIDE SEWER INSTALLATION DETAIL NOT TO SCALE CITY OF RENTON DWG. NAME. • BR39 SP PAGE. • B078 ---I I- 1/2" WEB 8 PL. 1 2" x 3" x 3 8" NON-SKID PATTERN CAST INTEGRAL ON TOP o 26-3 8" 25-1/4" 24" F1" �6'• _V/4" �1-1/4" Tj 23-1 4" 33-1 4" 1 " SEAT SECT/ON A -A FRAME (NON-LOCK/NG1 COVER (NON -LOCKING) FOR 5/8"-11 N.C. x 1-1/4" �5/8" 3/8•• r 1,-3/8" S S A SOC. HD. CAP SCREW (3 REQ D.) 1/2„ (TYP) B TYPICAL NON-SKID PATTERN 11-718 2' o (TYP) o A o B 25" FRAME (LOCKING) SECT/ON B-B 2" RAISED LETTERS AS REQ D. SEE N07E No.3 BELOW UNDERSIDE SHOWN FOR CLARITY 3/4" CORE (TYP.) ON 23" B.C. N.C. 1-1/2" CORE(TYP.) (LOCKING) NOTES• COVER 1. FOR NON -LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. 2. FOR LOCKING LID USE OLYMPIC FOUNDRY No. MH 30 D/T OR EQUAL. J. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SA NI TARY (SPECIFY "SE WER"), OR WA TER (SPECIFY "WA TER'). MANHOLE FRAME AND COVER DETAIL NOT TO SCALE CITY OF RENTON DWG. NAME. • BR29 SP PAGE: B074 SANITARY SEND? NOTES AND SPECIRCAT7ONS- ALL WORK MATERIALS SHALL BE /N CONFORMANCE NTH THE STANDARDS AND 1. SPEC/FICA 77ONS OF THE Cl TY OF RENTON AND THE LA TEST EDI77ON OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. 2. THE HOURS OF WORK /N THE STREET RIGHT -OF- WAY SHALL BE LIM17ED TO 8.30 AM TO 3.•30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED /N WRITING BY THE TRANSPORTA77ON DIVISION AT 277-6222. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE TRANSPOR TA 77ON DIVISION 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE N077FIED 24 HOURS IN ADVANCE. J. ALL CONS7RUCTION SHALL BE /N ACCORDANCE WITH THE STANDARD SPECIFICA7ONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST ED1170N (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. 4. ALL LOCATIONS OF EXIS77NG UTILITIES SHOwv ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR D/S77JRBANCE. 5. A PRECONSTRUC77ON CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STAR77NG NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTA T VE OF THE CITY OF RENTON.) I T SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE CITY INSPECTOR 24 HOURS t , , IN ADVANCE OF BACKFILLWG ALL CONSTRUCTION. uj 6. CONTRACTOR /S SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND O SEQUENCES OF CONSTRUC77ON AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUC7ION SITE. Z IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONS7RUC77ON. Q 8. PLANS APPROVED BY THE CITY OF RENTON, DEVELOPMENT SERVICES �• Q DIVISION, SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS 9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB S17E WHENEVER (� CONSTRUCTION IS /N PROGRESS. J 10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON KITH AN AS -BUILT Q DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED �. PROFESSIONAL SURVEYOR.uj 11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE /N Q LAYERS WITH A LOOSE AVERAGE DEP7H OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE 7HE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 1, , 12. OPEN CUT ROAD CROSSINGS FOR U77LITY TRENCHES ON EXIS77NG TRAVELED ''W^ ROADWAY SHALL BE BACKF/LLED WITH CRUSHED ROCK AND MECHANICALLY v, COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENTcc HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. Q 13. DATUM SHALL BE CITY OF RENTON, NAD 198311991 & NAVO 1988. 14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWSE STABILIZED TO 7HE SAT75FACT70N OF 77-IE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF rA CONSTRUCTION. v, 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERTY PREPARED FOUNDA77ON /N ACCORDANCE WITH SECT70N 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATI0NS FOR ROAD AND BRIDGE CONSTRUC770N. 7H/S SHALL INCLUDE NECESSARY LEVELING OF THE /\ TRIAD ASSOCIATES 77?ENCH BOTTOM OR THE TOP OF THE OF 7HE FOUNDA77ON MATERIAL AS ^ p4 WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO o UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE N w SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER A GASKETED ASTY D 3034, SDR 35, OR DUC77LE IRON CLASS 50. 1 Z IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 18 INCHES ABOVE FINISHED GRADE. IN PAVED AREAS COVER Q MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. M s•339204 Checked for Compliance to City Standards (C1 2007 TRIAD ASSOCIATES 12112 115th Ave. NE Kirkland, WA 98034-6929 425.821.8448 425.821.3481 fax 800.488.0756 toll free www.triadassoc.com Z n N h 0 W U U y 2 y o Q a � n 0 0 a A �o z ALD F. BUCK, AICP IJECT MANAGER C A. WNGER, PLS IJECT SURVEYOR ECCA S. CUSHMAN, PE IJECT ENGINEER -SHIOU UN, ASLA IJECT LANDSCAPE ARCHITECT ST SUBMITTAL DATE: 311107 LE: HORIZ.: NT 5 VERT.: N TS EXPIRES: 11/15/0 STAMP NOT VALID - - UNLESS SIGNED AND DATED JOB N0. 04-257 SHEET NO. 4 of 5 Cp 5-3517-04